950 resultados para Stent-graft
Resumo:
Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial.
Resumo:
Objectives We compared the angiographic and long-term clinical outcomes of patients with and without overlap of drug-eluting stents (DES). Background DES overlap has been associated with delayed healing and increased inflammation in experimental studies, but its impact on clinical outcome is not well established. Methods We analyzed the angiographic and clinical outcomes of 1,012 patients treated with DES in the SIRTAX (Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization) trial according to the presence or absence of stent overlap and the number of stents per vessel: 134 (13.2%) patients with multiple DES in a vessel with overlap, 199 (19.7%) patients with multiple DES in a vessel without overlap, and 679 (67.1%) patients with 1 DES per vessel. Results Angiographic follow-up at 8 months showed an increased late loss in DES overlap patients (0.33 ± 0.61 mm) compared with the other groups (0.18 ± 0.43 mm and 0.15 ± 0.38 mm, p < 0.01). The smallest minimal lumen diameter was located at the zone of stent overlap in 17 (68%) of 25 patients with stent overlap who underwent target lesion revascularization. Major adverse cardiac events were more common in patients with DES overlap (34 events, 25.4%) than in the other groups (42 events, 21.1% and 95 events, 14.0%) at 3 years (p < 0.01). Both the risk of target lesion revascularization (20.2% vs. 16.1% vs. 9.7%, p < 0.01) and the composite of death or myocardial infarction (17.2% vs. 14.1% vs. 9.1%, p = 0.01) were increased in patients with DES overlap compared with the other groups. Conclusions DES overlap occurs in >10% of patients undergoing percutaneous coronary intervention in routine clinical practice and is associated with impaired angiographic and long-term clinical outcome, including death or myocardial infarction. (Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization; NCT00297661).
Resumo:
This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES).
Resumo:
Impaired response to antiplatelet therapy with acetylsalicylic acid (ASA) and clopidogrel (CLO) has been associated with an increased risk of stent thrombosis and ischemic events after coronary stent implantation. We sought to investigate whether patients with a low response (LR) to ASA or CLO are at increased risk for periprocedural and short-term ischemic events after coronary stent implantation.
Resumo:
OBJECTIVES: We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. BACKGROUND: The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. METHODS: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. RESULTS: The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore
Resumo:
Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial approximately 10-20 microm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model.
Resumo:
This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer.
Resumo:
The use of radial artery conduits in coronary artery bypass grafting (CABG) surgery is associated with improved long-term patency and patient survival rates as compared with saphenous vein conduits. Despite increasing popularity, relative incidence of local harvest-site complications and subjective perception of adverse long-term sequelae remain poorly described.
Resumo:
Endovascular stent grafting represents a novel concept for type B aortic dissection both in the acute and subacute/chronic setting, with an unknown effect on outcomes.
Resumo:
The objective of the study was to determine the feasibility of generating a biodegradable, stem cell-loaded osteogenic composite graft from human placenta. Initially, a scaffold from human chorion membrane was produced. Human placenta mesenchymal stem cells (MSCs) derived from either first-trimester chorionic villi or term chorion membrane were differentiated osteogenically on this scaffold. Outgrowth, adherence, and osteogenic differentiation of cells were assessed by immunohistochemistry (IHC), scanning electron microscopy, protein expression, and real-time polymerase chain reaction (RT-PCR). Our results showed that a cell-free extracellular matrix scaffold can be generated from human chorion. Seeded MSCs densely adhered to that scaffold and were osteogenically differentiated. Calcium and alkaline phosphatase were detected in the cell-scaffold constructs as a proof of mineralization and findings were confirmed by IHC and RT-PCR results. This study shows for the first time that generation of an osteogenic composite graft using placental tissue is feasible. It might allow therapeutic application of autologous or allogeneic grafts in congenital skeletal defects by means of a composite graft.