963 resultados para S. Warwick
Resumo:
Multipulse irradiation with 100 ps pulses of stripe Germanium targets is shown to enhance by up to several orders-of-magnitude the output of Ne-like Ge lasing on the J = 0-1 line at 196 Angstrom compared to single pulse pumping. Various pre-pulse and multipulse configurations have been experimentally investigated for irradiances of approximate to 4 x 10(13) W/cm(2) with a 1.06 mu m wavelength pumping laser. The ionisation balance measured by a KeV crystal spectrometer (KAP crystal) has been found to not affect the X-ray laser output. Good agreement between the experimental results and a fluid code incorporating atomic physics, gain and X-ray beam ray tracing is obtained. The code results show that the enhanced X-ray laser output is produced by multipulse irradiation reducing the electron density gradients in the gain region and simultaneously increasing the gain region spatial size. These changes reduce the effect of refraction on the X-ray laser beam propagation.
Resumo:
We have studied the effect of prepulses in enhancing the efficiency of generating ASE beams in soft X-ray laser plasma amplifiers based on pumping Ne-like ions, Slab targets were irradiated with a weak prepulse followed by a main plasma heating pulse of nanosecond duration, Time-integrated; time and spectrally resolved and time and angularly resolved lasing emissions on the 3p-3s (J=0-1) XUV lasing lines of Ne-like Ni, Cu and Zn at wavelengths 232 Angstrom 221 Angstrom and 212 Angstrom respectively have been monitored. Measurements were made for pre-pulse/main-pulse intensity ratios from 10(-5)-10(-1) and for pump delay times of 2 ns and 4.5 ns. Zinc is shown to exhibit a peak in output intensity at similar to 2x10(-3) pre-pulse fraction for a 4.5 ns pump delay, with a main pulse pump intensity of similar to 1.3x10(13) W cm(-2) on a 20 mm target. The Zn lasing emission had a duration of similar to 240 ps and this was insensitive to prepulse fraction. The J=0-1 XUV laser output for nickel and copper increased monotonically with prepulse fraction, with copper targets showing least sensitivity to either prepulse level or prepulse to main pulse delay. Under the conditions of the study, the pre-pulse level was observed to haveno significant influence on the output intensity of the 3p-3s (J=2-1) lines of any of the elements investigated.
Resumo:
We report on measurements of the saturated single frequency output of a Ge XXIII x-ray laser on the J=0-->1 transition at 19.6 nm from a refraction compensating double target driven by 150 J of energy from 75-ps Nd-glass laser pulses. The 19.6-nm line completely dominated the laser output. The output energy was measured to be 0.9 mJ in a beam of 6.6x30 mrad(2) divergence, corresponding to a conversion efficiency of 6 x 10(-6).
Resumo:
Purpose – Informed by the work of Laughlin and Booth, the paper analyses the role of accounting and accountability practices within the 15th century Roman Catholic Church, more specifically within the Diocese of Ferrara (northern Italy), in order to determine the presence of a sacred-secular dichotomy. Pope Eugenius IV had embarked upon a comprehensive reform of the Church to counter the spreading moral corruption within the clergy and the subsequent disaffection with the Church by many believers. The reforms were notable not only for the Pope’s determination to restore the moral authority and power of the Church but for the essential contributions of ‘profane’ financial and accounting practices to the success of the reforms.
Design/methodology/approach – Original 15th century Latin documents and account books of the Diocese of Ferrara are used to highlight the link between the new sacred values imposed by Pope Eugenius IV’s reforms and accounting and accountability practices.
Findings – The documents reveal that secular accounting and accountability practices were not regarded as necessarily antithetical to religious values, as would be expected by Laughlin and Booth. Instead, they were seen to assume a role which was complementary to the Church’s religious mission. Indeed, they were essential to its sacred mission during a period in which the Pope sought to arrest the moral decay of the clergy and reinstate the Church’s authority. Research implications/limitations – The paper shows that the sacred-secular dichotomy cannot be considered as a priori valid in space and time. There is also scope for examining other Italian dioceses where there was little evidence of Pope Eugenius’ reforms.
Originality/value – The paper presents a critique of the sacred-secular divide paradigm by considering an under-researched period and a non Anglo-Saxon context.
Resumo:
Foucault identified the roots of governmentality in religious beliefs and religious history with its genealogical core the equivalent of pastoral power, the art of governing people by relying on a dualistic logic; individualization and totalization. This technology of power arose and matured within the Roman Catholic Church and provided a model for many states in the achievement and exercise of power. Informed by the work of Foucault on pastoral power the present work examines the genealogical core of governmentality in the context of the Roman Catholic Church at a time of great crisis in the 15th century when the Roman Catholic Church was undergoing reform instituted by Pope Eugenius IV (1431-1447). The contributions of accounting to pastoral power are shown in this study to have been pivotal in restoring the Church’s standing and influence. Accounting was one of the technologies that allowed the bishops to control both the diocese as a whole and each priest, to subjugate the priests to the bishops’ authority and, thereby, to govern the diocese through a never-ending extraction of truth.