993 resultados para Rudy, Gerard


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a new approach for state estimation of angles and frequencies of equivalent areas in large power systems with synchronized phasor measurement units. Defining coherent generators and their correspondent areas, generators are aggregated and system reduction is performed in each area of inter-connected power systems. The structure of the reduced system is obtained based on the characteristics of the reduced linear model and measurement data to form the non-linear model of the reduced system. Then a Kalman estimator is designed for the reduced system to provide an equivalent dynamic system state estimation using the synchronized phasor measurement data. The method is simulated on two test systems to evaluate the feasibility of the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Emergency health is a critical component of Australia’s health system and one which is increasingly congested from growing demand and blocked access to inpatient beds. The Emergency Health Services Queensland (EHSQ) study aims to identify the factors driving increased demand for emergency health and to evaluate strategies which may safely reduce the future demand growth. This monograph addresses the characteristics of users of emergency health services with an aim to identify those that appear to contribute to demand growth. This study utilises data on patients treated by Emergency Departments (ED) and Queensland Ambulance Service (QAS) across Queensland. ED data was derived from the Emergency Department Information System (EDIS) for the period 2001-02 through to 2010-11. Ambulance data was extracted from the QAS’ Ambulance Information Management System (AIMS) and electronic Ambulance Report Form (eARF) for the period 2001-02 through to 2009-10. Due to discrepancies and comparability issues for ED data, this monograph compares data from the 2003-04 time period with 2010-11 data for 21 of the reporting EDs. Also a snapshot of users for the 2010-11 financial year for 31 reporting EDs is used to describe the characteristics of users and to compare those characteristics with population demographics. For QAS data, the 2002-03 and 2009-10 time periods were selected for detailed analyses to identify trends. • Demand for emergency health care services is increasing, representing both increased population and increased relative utilisation. Per capita demand for ED attention has increased by 2% per annum over the last decade and for ambulance attention by 3.7% per annum. • The growth in ED demand is prominent in more urgent triage categories with actual decline in less urgent patients. An estimated 55% of patients attend hospital EDs outside of normal working hours. There is no evidence that patients presenting out of hours are significantly different to those presenting within working hours; they have similar triage assessments and outcomes. • Patients suffering from injuries and poisoning comprise 28% of the ED workload (an increase of 65% in the study period), whilst declines of 32% in cardiovascular and circulatory conditions, and musculoskeletal problems have been observed. • 25.6% of patients attending EDs are admitted to hospital. 19% of admitted patients and 7% of patients who die in the ED are triage category 4 or 5 on arrival. • The average age of ED patients is 35.6 years. Demand has grown in all age groups and amongst both men and women. Men have higher utilisation rates for ED in all age groups. The only group where the growth rate in women has exceeded men is in the 20-29 age group; this growth is particularly in the injury and poisoning categories. • Considerable attention has been paid publicly to ED performance criteria. It is worth noting that 50% of all patients were treated within 33 minutes of arrival. • Patients from lower socioeconomic areas appear to have higher utilisation rates and the utilisation rate for indigenous people appears to exceed those of European and other backgrounds. The utilisation rates for immigrant people is generally less than that of Australian born however it has not been possible to eliminate the confounding impact of different age and socioeconomic profiles. • Demand for ambulance service is also increasing at a rate that exceeds population growth. Utilisation rates have increased by an average of 5% per annum in Queensland compared to 3.6% nationally, and the utilisation rate in Queensland is 27% higher than the national average. • The growth in ambulance utilisation has also been amongst the more urgent categories of dispatch and utilisation rates are higher in rural and regional areas than in the metropolitan area. The demand for ambulance increases with age but the growth in demand for ambulance service has been more prominent in younger age groups. These findings contribute significantly to an understanding of the growth in demand for emergency health. It shows that the growth is amongst patients in genuine need of emergency healthcare and public rhetoric that the congestion of emergency health services is due to inappropriate attendees is unable to be substantiated. The consistency of the growth in demand over the last decade reflects not only the changing demographics of the Australian population but also the changes in health status, standards of acute health care and other social factors. The growth is also amongst patients with acute injury and poisoning which is inconsistent with rates of chronic disease as a fundamental driver. We have also interviewed patients in regard to their decision making choices for acute health care and the factors that influence these decisions and this will be the subject of a third Monograph and publications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With an increasing number of small-scale renewable generator installations, distribution network planners are faced with new technical challenges (intermittent load flows, network imbalances…). Then again, these decentralized generators (DGs) present opportunities regarding savings on network infrastructure if installed at strategic locations. How can we consider both of these aspects when building decision tools for planning future distribution networks? This paper presents a simulation framework which combines two modeling techniques: agent-based modeling (ABM) and particle swarm optimization (PSO). ABM is used to represent the different system units of the network accurately and dynamically, simulating over short time-periods. PSO is then used to find the most economical configuration of DGs over longer periods of time. The infrastructure of the framework is introduced, presenting the two modeling techniques and their integration. A case study of Townsville, Australia, is then used to illustrate the platform implementation and the outputs of a simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The behaviour of single installations of solar energy systems is well understood; however, what happens at an aggregated location, such as a distribution substation, when output of groups of installations cumulate is not so well understood. This paper considers groups of installations attached to distributions substations on which the load is primarily commercial and industrial. Agent-based modelling has been used to model the physical electrical distribution system and the behaviour of equipment outputs towards the consumer end of the network. The paper reports the approach used to simulate both the electricity consumption of groups of consumers and the output of solar systems subject to weather variability with the inclusion of cloud data from the Bureau of Meteorology (BOM). The data sets currently used are for Townsville, North Queensland. The initial characteristics that indicate whether solar installations are cost effective from an electricity distribution perspective are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resistance to chemotherapy and metastases are the major causes of breast cancer-related mortality. Moreover, cancer stem cells (CSC) play critical roles in cancer progression and treatment resistance. Previously, it was found that CSC-like cells can be generated by aberrant activation of epithelial–mesenchymal transition (EMT), thereby making anti-EMT strategies a novel therapeutic option for treatment of aggressive breast cancers. Here, we report that the transcription factor FOXC2 induced in response to multiple EMT signaling pathways as well as elevated in stem cell-enriched factions is a critical determinant of mesenchymal and stem cell properties, in cells induced to undergo EMT- and CSC-enriched breast cancer cell lines. More specifically, attenuation of FOXC2 expression using lentiviral short hairpin RNA led to inhibition of the mesenchymal phenotype and associated invasive and stem cell properties, which included reduced mammosphere-forming ability and tumor initiation. Whereas, overexpression of FOXC2 was sufficient to induce CSC properties and spontaneous metastasis in transformed human mammary epithelial cells. Furthermore, a FOXC2-induced gene expression signature was enriched in the claudin-low/basal B breast tumor subtype that contains EMT and CSC features. Having identified PDGFR-β to be regulated by FOXC2, we show that the U.S. Food and Drug Administration-approved PDGFR inhibitor, sunitinib, targets FOXC2-expressing tumor cells leading to reduced CSC and metastatic properties. Thus, FOXC2 or its associated gene expression program may provide an effective target for anti-EMT-based therapies for the treatment of claudin-low/basal B breast tumors or other EMT-/CSC-enriched tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Power system restoration after a large area outage involves many factors, and the procedure is usually very complicated. A decision-making support system could then be developed so as to find the optimal black-start strategy. In order to evaluate candidate black-start strategies, some indices, usually both qualitative and quantitative, are employed. However, it may not be possible to directly synthesize these indices, and different extents of interactions may exist among these indices. In the existing black-start decision-making methods, qualitative and quantitative indices cannot be well synthesized, and the interactions among different indices are not taken into account. The vague set, an extended version of the well-developed fuzzy set, could be employed to deal with decision-making problems with interacting attributes. Given this background, the vague set is first employed in this work to represent the indices for facilitating the comparisons among them. Then, a concept of the vague-valued fuzzy measure is presented, and on that basis a mathematical model for black-start decision-making developed. Compared with the existing methods, the proposed method could deal with the interactions among indices and more reasonably represent the fuzzy information. Finally, an actual power system is served for demonstrating the basic features of the developed model and method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, a new comprehensive planning methodology is proposed for implementing distribution network reinforcement. The load growth, voltage profile, distribution line loss, and reliability are considered in this procedure. A time-segmentation technique is employed to reduce the computational load. Options considered range from supporting the load growth using the traditional approach of upgrading the conventional equipment in the distribution network, through to the use of dispatchable distributed generators (DDG). The objective function is composed of the construction cost, loss cost and reliability cost. As constraints, the bus voltages and the feeder currents should be maintained within the standard level. The DDG output power should not be less than a ratio of its rated power because of efficiency. A hybrid optimization method, called modified discrete particle swarm optimization, is employed to solve this nonlinear and discrete optimization problem. A comparison is performed between the optimized solution based on planning of capacitors along with tap-changing transformer and line upgrading and when DDGs are included in the optimization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new control method for battery storage to maintain acceptable voltage profile in autonomous microgrids is proposed in this article. The proposed battery control ensures that the bus voltages in the microgrid are maintained during disturbances such as load change, loss of micro-sources, or distributed generations hitting power limit. Unlike the conventional storage control based on local measurements, the proposed method is based on an advanced control technique, where the reference power is determined based on the voltage drop profile at the battery bus. An artificial neural network based controller is used to determine the reference power needed for the battery to hold the microgrid voltage within regulation limits. The pattern of drop in the local bus voltage during power imbalance is used to train the controller off-line. During normal operation, the battery floats with the local bus voltage without any power injection. The battery is charged or discharged during the transients with a high gain feedback loop. Depending on the rate of voltage fall, it is switched to power control mode to inject the reference power determined by the proposed controller. After a defined time period, the battery power injection is reduced to zero using slow reverse-droop characteristics, ensuring a slow rate of increase in power demand from the other distributed generations. The proposed control method is simulated for various operating conditions in a microgrid with both inertial and converter interfaced sources. The proposed battery control provides a quick load pick up and smooth load sharing with the other micro-sources in a disturbance. With various disturbances, maximum voltage drop over 8% with conventional energy storage is reduced within 2.5% with the proposed control method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The well-established under-frequency load shedding (UFLS) is deemed to be the last of effective remedial measures against a severe frequency decline of a power system. With the ever-increasing size of power systems and the extensive penetration of distributed generators (DGs) in power systems, the problem of developing an optimal UFLS strategy is facing some new challenges. Given this background, an optimal UFLS strategy for a distribution system with DGs and load static characteristics taken into consideration is developed. Based on the frequency and the rate of change of frequency, the presented strategy consists of several basic rounds and a special round. In the basic round, the frequency emergency can be alleviated by quickly shedding some loads. In the special round, the frequency security can be maintained, and the operating parameters of the distribution system can be optimized by adjusting the output powers of DGs and some loads. The modified IEEE 37-node test feeder is employed to demonstrate the essential features of the developed optimal UFLS strategy in the MATLAB/SIMULINK environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel intelligent online demand side management system is proposed for peak load management in low-voltage distribution networks. This method uses low-cost controllers with low-bandwidth two-way communication installed in custumers’ premises and at distribution transformers to manage the peak load while maximising customer satisfaction. A multi-objective decision making process is proposed to select the load(s) to be delayed or controlled. The efficacy of the proposed control system is verified by simulation of three different feeder types.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives To review the existing research on the effectiveness of heat warning systems (HWSs) in saving lives and reducing harm. Methods A systematic search of major databases was conducted, using “heat, heatwave, high temperature, hot temperature, OR hot climate” AND “warning system”. Results Fifteen articles were retrieved. Six studies asserted that fewer people died of excessive heat after HWS implementation. HWS was associated with reduction in ambulance use. One study estimated the benefits of HWS to be 468millionforsaving117livescomparedto210,000 costs of running the system. Eight studies showed that mere availability of HWS did not lead to behavioral changes. Perceived threat of heat dangers to self/others was the main factor related to heeding warnings and taking proper actions. However, costs and barriers associated with taking protective actions, such as costs of running air conditioners, were of significant concern particularly to the poor. Conclusions Research in this area is limited. Prospective designs applying health behavior theories should establish whether HWS can produce the health benefits they are purported to achieve by identifying the target vulnerable groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heatwaves are associated with significant health risks particularly among vulnerable groups. To minimize these risks, heat warning systems have been implemented. The question therefore is how effective these systems are in saving lives and reducing heat-related harm. We systematically searched and reviewed 15 studies which examined this. Six studies asserted that fewer people died of excessive heat after the implementation of heat warning systems. Demand for ambulance decreased following the implementation of these systems. One study also estimated the costs of running heat warning systems at US$210,000 compared to the US$468 million benefits of saving 117 lives. The remaining eight studies investigated people?s response to heat warning systems and taking appropriate actions against heat harms. Perceived threat of heat dangers emerged as the main factor related to heeding the warnings and taking proper actions. However, barriers, such as costs of running air-conditioners, were of significant concern, particularly to the poor. The weight of the evidence suggests that heat warning systems are effective in reducing mortality and, potentially, morbidity. However, their effectiveness may be mediated by cognitive, emotive and socio-demographic characteristics. More research is urgently required into the cost-effectiveness of heat warning systems? measures and improving the utilization of the services.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Restoring a large-scale power system has always been a complicated and important issue. A lot of research work has been done on different aspects of the whole power system restoration procedure. However, more time will be required to complete the power system restoration process in an actual situation if accurate and real-time system data cannot be obtained. With the development of the wide area monitoring system (WAMS), power system operators are capable of accessing to more accurate data in the restoration stage after a major outage. The ultimate goal of the system restoration is to restore as much load as possible while in the shortest period of time after a blackout, and the restorable load can be estimated by employing WAMS. Moreover, discrete restorable loads are employed considering the limited number of circuit-breaker operations and the practical topology of distribution systems. In this work, a restorable load estimation method is proposed employing WAMS data after the network frame has been reenergized, and WAMS is also employed to monitor the system parameters in case the newly recovered system becomes unstable again. The proposed method has been validated with the New England 39-Bus system and an actual power system in Guangzhou, China.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The well-known power system stabilizer (PSS) is used to generate supplementary control signals for the excitation system of a generator so as to damp low frequency oscillations in the power system concerned. Up to now, various kinds of PSS design methods have been proposed and some of them applied in actual power systems with different degrees. Given this background, the small-disturbance eigenvalue analysis and large-disturbance dynamic simulations in the time domain are carried out to evaluate the performances of four different PSS design methods, including the Conventional PSS (CPSS), Single-Neuron PSS (SNPSS), Adaptive PSS (APSS) and Multi-band PSS (MBPSS). To make the comparisons equitable, the parameters of the four kinds of PSSs are all determined by the steepest descent method. Finally, an 8-unit 24-bus power system is employed to demonstrate the performances of the four kinds of PSSs by the well-established eigenvalue analysis as well as numerous digital simulations, and some useful conclusions obtained.