949 resultados para Resin-modified glass ionomer cement
Resumo:
In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).
Resumo:
Desde su aparición en el año 1972, los cementos de ionómero vítreo han tenido una gran aplicación en varias disciplinas odontológicas tales como, operatoria dental, endodoncia, prótesis, etcétera. (10) La técnica desarrollada por los investigadores preconiza el pretratamiento dentinario con el fin de exponer los grupos calcio de la hidroxiapatita de la dentina para lograr una buena adhesión química de este cemento al elemento dentario. (10) El desarrollo de los ionómeros de alta densidad constituye el comienzo de una nueva manera de encarar el ejercicio profesional con un criterio más biológico, más preventivo y menos invasivo. (5) Dado que este tipo de cemento es muy utilizado en las técnicas de restauración atraumática que se implementan a nivel comunitario y que son realizadas en lugares físicos que no poseen todos los requisitos tecnológicos de un consultorio odontológico, se propuso como objetivo de este estudio medir la eficacia del pretratamiento con ácido poliacrílico al 10% en distintos sustratos dentinarios (normal, cariado y esclerótico) (13) evaluando los resultados mediante la determinación de la resistencia adhesiva del cemento a dichos sustratos.
Resumo:
En el presente trabajo se evaluaron 4 casos clínicos de pacientes con riesgo de caries pero que poseían molares sin lesiones, a los cuales se les colocó selladores de fosas y fisuras: en dos pacientes con resina y en dos pacientes con ionómero de vidrio. Los mismos fueron controlados en su permanencia en boca, los de resina en 6 meses y los de ionómero en 2 años, no encontrándose diferencias clínicas entre los materiales utilizados, debido a la diferencia en el tiempo de control de los mismos. Paralelamente, se realizó un trabajo in vitro con dos grupos de 10 molares cada uno, tratados el grupo 1 con sellador a base de resina y el grupo 2 con sellador de ionómero de vidrio. Luego de someter las muestras a la acción de un colorante (azul de metileno) se seccionaron longitudinalmente y se observaron en una lupa estereoscópica para ver si el colorante había penetrado o no por la interfase sellador/esmalte. No se encontraron diferencias estadísticamente significativas (a>0.05) entre los grupos analizados.
Resumo:
Background: This study aimed to determine the reasons for dentists' choice of materials, in particular amalgam and resin composite, in Australia. Method: A questionnaire was developed to elicit this information. The names and addresses of 1000 dentists in Australia were selected at random. The questionnaire was mailed to these dentists with an explanatory letter and reply-paid envelope. Results: A total of 560 replies were received. Regarding choice of material, 99 per cent of respondents cited clinical indication as an influencing factor, although patients' aesthetic demands (99 per cent), patients' financial situation (82 per cent), and lecturers' suggestions (72 per cent) were also reported to influence respondents' choice of materials. Twelve per cent of respondents used composite 'always', 29 per cent 'often', 32 per cent 'sometimes', 23 per cent 'seldom' and 4 per cent 'never' in extensive load-bearing cavities in molar teeth. For composite restorations in posterior teeth, 84 per cent 'always', 'often' or 'sometimes' used the total etch technique, 84 per cent used a thick glass-ionomer layer and 36 per cent never used rubber dam. Fifty-nine per cent of respondents reported a decreased use of amalgam over the previous five years. Sixty-eight per cent of respondents agreed with the statement 'discontinuation of amalgam restricts a dentist's ability to adequately treat patients'. Seventy-five per cent considered that the growth in the use of composites increased the total cost of oral health care. Conclusions: Of the respondents from Australia 73 per cent place large composite restorations in molar teeth and their choice of material is influenced greatly by clinical indications, and patients' aesthetic demands.
Resumo:
The aim of this in vitro study was to evaluate the fracture load and marginal accuracy of crowns made from a shrinkage-free ZrSiO4 ceramic cemented with glass-ionomer or composite cement after chewing simulation. Thirty-two human mandibular molars were randomly divided into two groups. All teeth were prepared for and restored with shrinkage-free ZrSiO4 ceramic crowns (Everest HPC (R), KaVo). The crowns of group A (N = 16) were luted to the teeth using KetacCem (R) and group B (N = 16) were adhesively cemented using Panavia (R) 21EX. Measurements of the marginal accuracy before and after cementation were made using replicas and an image analysis system. All specimens were exposed to 1.2 million cycles of thermo-mechanical fatigue in a chewing simulator. Surviving specimens were subsequently loaded until fracture in a static testing device. Fracture loads (N) were recorded. All specimens survived chewing simulation. The mean fracture loads (+/- s.d.) were Group A, 1622 N (+/- 433); group B, 1957 N (+/- 806). There was no significant difference between the two groups (P > 0.05). The marginal gap values before cementation were (mean +/- s.d.): Group A, 32.7 mu m (+/- 6.8); group B, 33.0 mu m (+/- 6.7).The mean marginal gap values after cementation were (+/- s.d.): Group A, 44.6 mu m (+/- 6.7); group B, 46.6 mu m (+/- 7.7). The marginal openings were significantly higher after cementation for both groups (P < 0.05). All test groups demonstrated fracture load and marginal accuracy values within the range of clinical acceptability.
Resumo:
Las resinas compuestas y adhesivos dentales se utilizan ampliamente para la restauración de dientes con pulpas vitales. La preferencia en el uso de estas resinas compuestas podría estar atribuida a que son materiales con buenos resultados estéticos y se consideran materiales de restauración estables. Sin embargo se ha demostrado que son susceptibles a la degradación y liberación de la fracción de sus componentes y que cierta cantidad de los monómeros de su composición permanecen sin polimerizar por un largo periodo de tiempo, pudiendo estos filtrarse hacia el tejido pulpar y causar alteraciones de la actividad fisiológica de las células de la pulpa (DPCs) (1). Además, estudios in vitro han demostrado que los componentes de las resinas compuestas tienen potenciales tóxicos, generando respuestas inmediatas y a largo plazo luego de su aplicación. Identificar el potencial tóxico y deletéreo de los materiales de restauración sobre el tejido pulpar es de gran interés y relevancia clínica, por ello este estudio comprende en una revisión de la literatura acerca de la respuesta pulpar a los materiales de restauración tipo resina.
Resumo:
The radial distribution functions (RDFs) of five xLi2S.(1 - x)B2S3 glasses (x = 0.55, 0.60, 0.67, 0.71 and 0.75) have been determined from neutron diffraction experiments performed at the Institut Laue-Langevin, Grenoble. These glasses are prepared by casting a molten mixture of boron, sulphur and Li2S inside a controlled atmosphere glovebox. Addition of the Li2S Modifier is found gradually to suppress all peaks corresponding to interatomic distances > 3.5 angstrom, which implies that the structural entities present in these glasses become segmented, and therefore more ionic, as x increases. The assumption of the existence of four main structural entities based on four- and three-coordinated borons (the latter carrying bridging and/or non-bridging sulphurs) accounts for all the peaks present in the RDFs as a function of composition. Furthermore, in the most modified glass (x = 0.75), that which contains only 'isolated' BS33- triangles, there seems to be evidence for either octahedral or tetrahedral coordination of Li+ by S- ions
Resumo:
O objetivo deste trabalho foi o de avaliar in vitro o efeito da ação antibacteriana de cimentos de ionômero de vidro (CIVs) convencionais incorporados com diacetato de clorexidina (DCHX) sobre o Streptococcus mutans. Foram testados os CIVs Maxxion R e Vitro Fil R com a incorporação dos percentuais de 0,5%, 1% e 2% de DCHX através de difusão em ágar e pela exaustão do DCHX por até 40 dias, a fim de observar a longevidade de sua ação inibitória. Foi também avaliado o efeito do fluoreto de sódio na ação antibacteriana do DCHX. Para determinar a diferença entre a média dos halos de inibição Os resultados foram analisados por análise de variância e pelo teste Student-Newman-Keuls (SNK). Todos os corpos de prova com DCHX apresentaram halo para os CIVs variando de 2,29mm a 6,82mm para o Maxxion R e de 1,73mm a 8,97mm para o Vitro Fil R. A capacidade de inibição foi proporcional à concentração de DCHX. Através do teste SNK apenas os grupos Vitro Fil R 0,5% e1% não variaram significativamente entre si. O 15o dia foi o de maior atividade antibacteriana para ambos os CIVs. Os grupos Maxxion R 1% e 2% foram os que menos apresentaram diferenças ao longo do tempo. Não houve crescimento de S mutans para os períodos de 7 e 15 dias de exaustão, sendo verificado o crescimento de colônias apenas na superfície do meio após o período de 96hs de incubação. Não foi observado efeito antagônico na capacidade antibacteriana do DCHX na presença de fluoreto de sódio. A incorporação de DCHX aos CIVs Maxxion R e Vitro Fil R, nas concentrações testadas e por um período de até 40 dias, apresentam resultados positivos no controle bacteriano de S mutans. Dentro das limitações deste estudo é lícito concluir que: efeito da inibição ao S mutans é dependente da concentração do DCHX; o fluoreto por si só não é capaz de inibir o crescimento de S mutans; a associação do DCHX com os CIVs não alterou a capacidade da ação antibacteriana da CHX; a ação antibacteriana da CHX incorporada aos CIVs se mantém eficaz por 15 dias, independente do CIV testado.
Resumo:
The shape-con trolled synthesis of micrometer- sized gold nanocoralline was simply realized via a wet-chemical approach. The as-prepared hierarchical gold nanocorallines (HGNs) on the solid substrate were initially applied in SERS analysis with 4-aminothiophenol (4-ATP) as the probe molecule. The HGN-modified glass substrate exhibits a higher SERS effect (one order of magnitude higher) than the aggregated gold nanoparticle (similar to 25 nm)-modified glass substrate.
pH-dependent conformational changes of ferricytochrome c induced by electrode surface microstructure
Resumo:
pH-dependent processes of bovine heart ferricytochrome c have been investigated by electronic absorption and circular dichroism (CD) spectra at functionalized single-wall carbon 'nanotubes (SWNTs) modified glass carbon electrode (SWNTs/ GCE) using a long optical path thin layer cell. These methods enabled the pH-dependent conformational changes arising from the heme structure change to be monitored. The spectra obtained at functionalized SWNTs/GCE reflect electrode surface microstructure-dependent changes for pH-induced protein conformation, pK(a) of alkaline transition and structural microenvironment of the ferricytochrome c heme. pH-dependent conformational distribution curves of ferricytochrome c obtained by analysis of in situ CD spectra using singular value decomposition least square (SVDLS) method show that the functionalized SWNTs can retain native conformational stability of ferricytochrome c during alkaline transition.
Resumo:
Electrocatalytic mechanism for the electrochemical oxidation of formaldehyde (HCHO) on the highly dispersed Au microparticles electrodeposited on the surface of the glass carbon (GC) electrode in the alkaline Na2CO3/NaHCO3 solution and the surface characteristics of the Au microparticle-modified glass carbon (Au/GC) electrode were studied with in situ FTIR spectroscopy, scanning electron microscopy (SEM) and X-ray diffraction (XRD). It was found that the final products of HCHO oxidation is HCOO- at the Au/GC electrode and CO2 at the bulk Au electrode. The difference may be ascribed to the different surface characteristics between the Au/GC electrode and the bulk Au electrode. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
We used microarray technology to study differentially expressed genes in white spot syndrome virus (WSSV)-infected shrimp. A total of 3136 cDNA targets, including 1578 unique genes from a cephalothorax cDNA library and 1536 cDNA clones from reverse and forward suppression subtractive hybridization (SSH) libraries of Fenneropenaeus chinensis, plus 14 negative and 8 blank control clones, were spotted onto a 18 x 18 mm area of NH2-modified glass slides. Gene expression patterns in the cephalothorax of shrimp at 6 h after WSSV injection and moribund shrimp naturally infected by WSSV were analyzed. A total of 105 elements on the arrays showed a similar regulation pattern in artificially infected shrimp and naturally infected moribund shrimp; parts of the results were confirmed by semiquantitative reverse transcriptase-polymerase chain reaction (RT-PCR). The up-regulated expression of immune-related genes, including heat shock proteins (HSP70 and HSP90), trehalose-phosphate synthase (TPS), ubiquitin C, and so forth, were observed when shrimp were challenged with WSSV. Genes including myosin LC2, ATP synthase A chain, and arginine kinase were found to be down-regulated after WSSV infection. The expression of housekeeping genes such as actin, elongation factor, and tubulin is not stable, and so these genes are not suitable as internal standards for semiquantitative RT-PCR when shrimp are challenged by WSSV. As a substitute, we found that triosephosphate isomerase (TPI) was an ideal candidate of interstandards in this situation.
Resumo:
Os objectivos do presente trabalho foram a investigação dos principais defeitos que ocorrem nos produtos de vidro de mesa produzidos por processos automáticos e o desenvolvimento de novos vidros e tecnologias que permitam aumentar os rendimentos de produção, ou a flexibilidade da operação de conformação. A viscosidade influencia a facilidade de conformação dos produtos. Temperaturas de gota mais baixas, espessuras de parede de produtos mais elevadas e baixas áreas de transferência térmica facilitam a ocorrência de defeitos, sobretudo mecânicos e de superfície. Foram identificados os produtos de vidro de mesa que apresentam maiores dificuldades na conformação, designados por produtos de forma complexa. Por ser um factor relevante na prática, discutiu-se o efeito da quantidade de casco usado na elaboração dos vidros sobre a conformação de produtos de forma complexa. A quantidade de casco influencia a volatilização de fundentes que por sua vez tem efeito sobre as propriedades de trabalhabilidade do vidro. Desenvolveram-se novos vidros compatíveis com a utilização de queimos enriquecidos em oxigénio que são utilizados para reduzirem os defeitos mecânicos e de superfície nos produtos de vidros de mesa prensados. A compatibilidade vidro/tecnologia fez-se com uma modificação do sistema de afinação do vidro. Os vidros modificados apresentam propriedades físicoquímicas semelhantes à do vidro inicial e por isso indicam viabilidade comercial. A tecnologia dos canais corantes foi utilizada para modificar a trabalhabilidade de um vidro base a partir da introdução até 5 % de fritas incolores ricas em Li2O. Os valores de RMS (velocidade relativa de máquina) desceram de 106,8 % para 95,7 % enquanto os valores de Pt (patamar de trabalho) subiram de 100,6 s para 111,3 s com o aumento de frita. As propriedades físico-químicas dos vidros aditivados com frita indicam viabilidade comercial. Esta inovação tecnológica introduz flexibilidade nos processos industriais vidreiros. A composição química do vidro e por isso as propriedades relacionadas com a trabalhabilidade podem ser entendidas como mais uma variável dos processos de conformação e usadas em função das técnicas de conformação disponíveis, da forma dos objectos a conformar e da engenharia da ferramenta moldante utilizada. Foi observada convergência entre os resultados experimentais e os valores calculados a partir dos modelos de Huff e Fluegel nos principais parâmetros da tecnologia vidreira (RMS e Pt) e nas propriedades dos vidros nomeadamente densidade e coeficiente de dilatação térmico. Uma parte importante deste trabalho decorreu em ambiente industrial. Em temas relacionados com a investigação do processamento vidreiro industrial, a prática de desenvolver trabalho experimental integrado no próprio ambiente industrial está claramente documentada na bibliografia publicada em revistas e jornais de referência internacional. ABSTRACT: The research on the causes of major defects that occur in glass tableware products produced by automatic processes and the development of new glasses and technologies for increasing the production efficiency, or the flexibility of operation were the objectives of the Thesis project. Viscosity influences the flexibility of glass forming. Lower drop temperatures, high product wall thicknesses, or low areas of heat transfer facilitate the occurrence of defects, mainly mechanical and surface born. We identified the products of glass tableware showing the greatest difficulties in forming, designated as complex shape products. The effect of the amount of recycled glass used in the preparation of glass batches on the conformation of products of complex shapes and on glass workability is discussed. The amount of recycled glass affects the volatilization of glass modifiers which in turn have an effect on the glass properties and workability. New glasses which become compatible with the use of oxygen burners were formulated, tested and developed to the industrial use, oxygen enrichment being used to reduce the mechanical and surface defects in pressed glass tableware. Compatibility glass / technology was achieved with a modified system of tuning of the glass. The modified glasses have physical and chemical properties similar to the original glass and therefore are commercially viable. The technology of the colouring channels was used to change glass workability of a glass base by the introduction of up to 5 % Li2O rich in colourless frit. The values of RMS (relative machine speed) fell from 106.8 % to 95.7 % while the values of Pt (cooling time) increased from 100.6 s to 111.3 s by the introduction of glass frits. The physico-chemical properties of the modified glass show commercial viability. This technology introduces flexibility in industrial processes of glass. The chemical composition of glass and therefore the properties related to workability can be understood as another variable of the glass forming processes and used according to the available forming techniques, the shape of objects and the engineering tools used for the moulds. Convergence was observed between experimental and predicted from Huff and Fluegel models in studying the properties of glasses. An important part of this work was done inside the industrial environment. On issues related to the investigation of the glass processing inside the industry, the practice of developing experimental work integrated in the industrial environment is clearly documented and referenced in the published literature in international journals and periodicals.
Resumo:
L’objectif de cette étude était d’évaluer et de comparer la force d’adhésion de deux résines de collage: le ClearfilTM Esthetic Cement & DC Bond Kit (C) et le RelyXTM Unicem (R), sur trois adhérents différents : une surface d’émail, un alliage de métaux non précieux (Np) et un alliage de métaux semi-précieux (Sp). La surface des échantillons des alliages métalliques a subi différents traitements de surface. Sur l’émail (n=15) ainsi que sur les plaquettes d’alliages Np et Sp (n=15), des cylindres de résine étaient appliqués et polymérisés. Suite au processus de collage, les échantillons ont été incubés à 37°C pendant 24 heures, puis ont subi 500 cycles de thermocyclage. Des tests de cisaillement ont été effectués, suivi par l’analyse de la surface des échantillons au microscope à balayage électronique. Une comparaison de type T-test et des comparaisons multiples post hoc, ont été effectuées pour l’analyse statistique (p 0,05). Sur l’émail, les résultats ont démontré que la résine C présentait une force d'adhésion moyenne statistiquement supérieure (33,97±17,18 MPa) à la résine R (10,48±11,23 MPa) (p 0,05). Le type d’alliage utilisé n’influençait pas la force d’adhésion, et ce, peu importe le type de résine de collage (p>0,05). Pour le groupe Sp, la résine C a démontré une adhésion statistiquement supérieure à la résine R, et ce, pour tous les traitements de surface (p 0,05). En conclusion, la résine C a démontré des résultats d’adhésion significativement supérieurs à la résine R sur l’émail ainsi que sur presque toutes les surfaces traitées des alliages de métaux.