882 resultados para Reflection principle
Resumo:
The X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method. © 2013 AIP Publishing LLC.
Resumo:
A novel method of preparation of the Si nanoparticles (NPs) incorporated in tellurite TeO2-WO3-Bi2O3 (TWB) thin films is proposed. This mew method applies RF magnetron sputtering technique at room temperature. The incorporation of Si NP was confirmed by transmission electron microscopy (TEM); isolated Si NPs with diameters of around 6 nm are observed. Energy dispersive X-ray spectroscopy (EDS) was performed during TEM analysis in order to confirm the presence of Si NP and also the other elements of the thin film. The thin films are explored with respect to the photoinduced changes of the reflectivity within the 400-65 nm spectra range using a 10 ns pulsed Nd:YAG with power densities varying up to 400 MW/cm2 and beam diameter within the 3-5 mm range. The observed processes are analyzed within a framework of trapping level conceptions for the Si NP. The possible application of the discovered materials as optical sensitive sensors is proposed. © 2013 Elsevier B.V.
Resumo:
Ticks are hematophagous ectoparasites which can transmit several diseases to the host during their feeding process. When ticks mechanically damage the tissue, they eventually induce inflammatory responses on the skin spot where they are fixed. One of the alternatives to control these ectoparasites is the use of chemical substances like selamectin - the active principle of Pfizer's antiparasitic Revolution® - a macrocyclic lactone capable of doing neurotoxic damage to the tick and eventually eliminating infestation in dogs and cats. The purpose of this study was to analyze, using histological and histochemical techniques, the occurrence of morphophysiological alterations in the skin of the host rabbits exposed to selamectin and infested with Rhipicephalus sanguineus (Acari: Ixodidae). Histologically, the exposed and infested rabbits showed a partial and/or total decrease in the stratum corneum and the epithelium decreased in the number of cell layers, consequently reducing the stratification (thinning) and quite pronounced formations of sub-epidermal edemas with consequent disorganization of collagen fibers in the dermal layer's connective tissue. Histochemical tests showed strong periodic acid-Schiff-positive reaction in the hair follicle and some regions of the dermis, besides resynthesis of collagen fibers detected by Mallory's trichrome technique. The obtained results showed that selamectin acts like a toxicant agent when in contact with the skin of the rabbit infested with ticks, inducing morphophysiological alterations in the acute inflammatory process in the animal's tegument. Selamectin is a chemical substance which has a dose-dependent action since higher concentrations cause greater morphophysiological damage in the skin of rabbits. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
This paper presents a novel time domain approach for Structural Health Monitoring (SHM) systems based on Electromechanical Impedance (EMI) principle and Principal Component Coefficients (PCC), also known as loadings. Differently of typical applications of EMI applied to SHM, which are based on computing the Frequency Response Function (FRF), in this work the procedure is based on the EMI principle but all analysis is conducted directly in time-domain. For this, the PCC are computed from the time response of PZT (Lead Zirconate Titanate) transducers bonded to the monitored structure, which act as actuator and sensor at the same time. The procedure is carried out exciting the PZT transducers using a wide band chirp signal and getting their time responses. The PCC are obtained in both healthy and damaged conditions and used to compute statistics indexes. Tests were carried out on an aircraft aluminum plate and the results have demonstrated the effectiveness of the proposed method making it an excellent approach for SHM applications. Finally, the results using EMI signals in both frequency and time responses are obtained and compared. © The Society for Experimental Mechanics 2014.
Resumo:
Revisa brevemente la teoría que hay detrás de las dos interpretaciones del principio contaminador-pagador, para comentar las implicaciones de éstas en la política ambiental, y considerar en qué medida este principio es aplicado en la práctica.
Resumo:
Pós-graduação em Educação - IBRC
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Principle 10 of the Rio Declaration on Environment and Development, 1992
Resumo:
Pós-graduação em Enfermagem (mestrado profissional) - FMB