932 resultados para Read Out Driver, Data Acquisition, Electronics, FPGA, ATLAS, IBL, Pixel Detector, LHC, VME


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A search for evidence of invisible-particle decay modes of a Higgs boson produced in association with a Z boson at the Large Hadron Collider is presented. No deviation from the standard model expectation is observed in 4.5 fb−1 (20.3 fb−1) of 7 (8) TeV pp collision data collected by the ATLAS experiment. Assuming the standard model rate for ZH production, an upper limit of 75%, at the 95% confidence level is set on the branching ratio to invisible-particle decay modes of the Higgs boson at a mass of 125.5 GeV. The limit on the branching ratio is also interpreted in terms of an upper limit on the allowed dark matter-nucleon scattering cross section within a Higgs-portal dark matter scenario. Within the constraints of such a scenario, the results presented in this Letter provide the strongest available limits for low-mass dark matter candidates. Limits are also set on an additional neutral Higgs boson, in the mass range 110 < mH < 400 GeV, produced in association with a Z boson and decaying to invisible particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in which dosimeter response is not inhibited by oxygen, was found to make up roughly one fourth of the total dosimeter volume. Delivering a dose across multiple fractions was found to yield a greater response than delivering the same dose in a single irradiation. The dosimeter was found to accurately measure a dose distribution produced by overlapping photon fields, yielding gamma pass rates of 95.4% and 93.1% from two planar gamma analyses. Proton irradiations were performed for measurements of proton dose and LET. Initial irradiations performed through the side of a dosimeter led to OCT artifacts. Gamma pass rates of 85.7% and 89.9% were observed in two planar gamma analyses. In irradiations performed through the base of a dosimeter, gel response was found to increase with height in the dosimeter, even in areas of constant dose. After a correction was applied, gamma pass rates of 94.6% and 99.3% were observed in two planar gamma analyses. Absolute dose measurements were substantially higher (33%-100%) than the delivered doses for proton irradiations. Issues encountered while calibrating the LET-Meter gel restricted analysis of the LET measurement data to the SOBP of a proton beam. LET-Meter overresponse was found to increase linearly with track-average LET across the LET range that could be investigated (1.5 keV/micron – 3.5 keV/micron).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IBAMar (http://www.ba.ieo.es/ibamar) is a regional database that puts together all physical and biochemical data obtained by multiparametric probes (CTDs equipped with different sensors), during the cruises managed by the Balearic Center of the Spanish Institute of Oceanography (COB-IEO). It has been recently extended to include data obtained with classical hydro casts using oceanographic Niskin or Nansen bottles. The result is a database that includes a main core of hydrographic data: temperature (T), salinity (S), dissolved oxygen (DO), fluorescence and turbidity; complemented by bio-chemical data: dissolved inorganic nutrients (phosphate, nitrate, nitrite and silicate) and chlorophyll-a. In IBAMar Database, different technologies and methodologies were used by different teams along the four decades of data sampling in the COB-IEO. Despite of this fact, data have been reprocessed using the same protocols, and a standard QC has been applied to each variable. Therefore it provides a regional database of homogeneous, good quality data. Data acquisition and quality control (QC): 94% of the data are CTDs Sbe911 and Sbe25. S and DO were calibrated on board using water samples, whenever a Rossetta was available (70% of the cases). All CTD data from Seabird CTDs were reviewed and post processed with the software provided by Sea-Bird Electronics. Data were averaged to get 1 dbar vertical resolution. General sampling methodology and pre processing are described in https://ibamardatabase.wordpress.com/home/). Manual QC include visual checks of metadata, duplicate data and outliers. Automatic QC include range check of variables by area (north of Balearic Islands, south of BI and Alboran Sea) and depth (27 standard levels), check for spikes and check for density inversions. Nutrients QC includes a preliminary control and a range check on the observed level of the data to detect outliers around objectively analyzed data fields. A quality flag is assigned as an integer number, depending on the result of the QC check.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the production of the orthophoto map Vernagtferner 1979, scale I: 10000, photographs of the flight "Hintereisferner 1979" were used, which have been found to be very suitable for differential rectification. Control points were determined before the flight took place. The processing of nine stereopairs was carried out on an analytical plotter. Simultaneously with the on-line plotting of the contour lines the reference data for the computation of the profiles for the differential rectification were recorded. The orthophoto map was covered by four aerial photographs. A smooth data transfer was ensured because the same computer was used for the data acquisition and the differential rectification. Two printing originals were prepared, one for the outline drawings with contour lines and another for the orthophoto. The print was done in black for the two copies. The data acquisition, the computation of the scanning profiles for the othoprojector and the procedure of the differential rectification are described. The reason for the use of on-line drawn contour lines is explained. Further applications, also for digital contour lines, are introduced. Possibilities for the achievement of high photo quality during the reproduction are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The report presents the results of the CTD measurements carried out in the Bellingshausen Sea - an area rare of CTD measurements. The main part of the report consists of the brief description of the CTD data acquisition and processing routines, the vertical profiles of temperature, salinity and density, and of the plots of the distribution of these properties along the hydrographic sections. The final part of the report deals with the notably similar structure of the vertical density distribution at different locations if presented as a function of a non dimensional vertical co-ordinate. It is pointed out that such a distribution could be an asymptotic limit of stationary mixing along neutral surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a series of attempts to research and document relevant sloshing type phenomena, a series of experiments have been conducted. The aim of this paper is to describe the setup and data processing of such experiments. A sloshing tank is subjected to angular motion. As a result pressure registers are obtained at several locations, together with the motion data, torque and a collection of image and video information. The experimental rig and the data acquisition systems are described. Useful information for experimental sloshing research practitioners is provided. This information is related to the liquids used in the experiments, the dying techniques, tank building processes, synchronization of acquisition systems, etc. A new procedure for reconstructing experimental data, that takes into account experimental uncertainties, is presented. This procedure is based on a least squares spline approximation of the data. Based on a deterministic approach to the first sloshing wave impact event in a sloshing experiment, an uncertainty analysis procedure of the associated first pressure peak value is described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultipliers (SiPMs) is proposed for the construction of a 4D-PET module of 4.8×4.8 cm2 aimed to replace the standard PMT based PET block detector. The module will be based on a LYSO continuous crystal read on two faces by Silicon Photomultipliers. A high granularity detection surface made by SiPM matrices of 1.5 mm pitch will be used for the x–y photon hit position determination with submillimetric accuracy, while a low granularity surface constituted by 16 mm2 SiPM pixels will provide the fast timing information (t) that will be used to implement the Time of Flight technique (TOF). The spatial information collected by the two detector layers will be combined in order to measure the Depth of Interaction (DOI) of each event (z). The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Data Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities and to manage many channels. The paper describes the progress made on the development of the proof of principle module under construction at the University of Pisa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

EURATOM/CIEMAT and Technical University of Madrid (UPM) have been involved in the development of a FPSC [1] (Fast Plant System Control) prototype for ITER, based on PXIe (PCI eXtensions for Instrumentation). One of the main focuses of this project has been data acquisition and all the related issues, including scientific data archiving. Additionally, a new data archiving solution has been developed to demonstrate the obtainable performances and possible bottlenecks of scientific data archiving in Fast Plant System Control. The presented system implements a fault tolerant architecture over a GEthernet network where FPSC data are reliably archived on remote, while remaining accessible to be redistributed, within the duration of a pulse. The storing service is supported by a clustering solution to guaranty scalability, so that FPSC management and configuration may be simplified, and a unique view of all archived data provided. All the involved components have been integrated under EPICS [2] (Experimental Physics and Industrial Control System), implementing in each case the necessary extensions, state machines and configuration process variables. The prototyped solution is based on the NetCDF-4 [3] and [4] (Network Common Data Format) file format in order to incorporate important features, such as scientific data models support, huge size files management, platform independent codification, or single-writer/multiple-readers concurrency. In this contribution, a complete description of the above mentioned solution is presented, together with the most relevant results of the tests performed, while focusing in the benefits and limitations of the applied technologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laminatedglass is composed of two glass layers and a thin intermediate PVB layer, strongly influencing PVB's viscoelastic behaviour its dynamic response. While natural frequencies are relatively easily identified even with simplified FE models, damping ratios are not identified with such an ease. In order to determine to what extent external factors influence dampingidentification, different tests have been carried out. The external factors considered, apart from temperature, are accelerometers, connection cables and the effect of the glass layers. To analyse the influence of the accelerometers and their connection cables a laser measuring device was employed considering three possibilities: sample without instrumentation, sample with the accelerometers fixed and sample completely instrumented. When the sample is completely instrumented, accelerometer readings are also analysed. To take into consideration the effect of the glass layers, tests were realised both for laminatedglass and monolithic samples. This paper presents in depth data analysis of the different configurations and establishes criteria for data acquisition when testing laminatedglass.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phytohormones regulate a wide array of developmental processes throughout the life cycle of plants. Over recent years, mounting evidence led to the widely accepted concept that plant hormone action is not the read-out of linear pathways, but determined by the extensive combinatorial activity of the signaling molecules and the integration of their signaling pathways, both in terms of regulating growth and development and in adapting to external stimuli. Recent work is beginning to shed light on the crosstalk of both nominally synergistically and antagonistically acting plant hormones such as, for example, auxins with oxylipins. Here, we report that oxylipins directly contribute to the regulation of the expression of two Arabidopsis YUCCA (YUC) genes, YUC8 and YUC9. Similar to previously characterized YUC family members, we identify both YUC8 and YUC9 as involved in local auxin biosynthesis, as demonstrated by the altered auxin contents and auxin-dependent phenotypes displayed by loss-of function mutants and transgenic overexpressing lines. Gene expression data obtained by qPCR analysis and microscopic examination of promoter-reporter lines reveal an oxylipin-mediated regulation of YUC9 expression that is dependent on the COI1 signal transduction pathway. The microscopic data indicate a functional overlap of the two analyzed auxin biosynthesis genes, but also point out specific functions for YUC8 and YUC9, which are in part related to different spatio-temporal expression pattern. In support of these findings, the analyzed yuc knockout mutants had lower free auxin contents and displayed a reduced response to oxylipins. This work provides evidence of a molecular mechanism that links oxylipin signaling with auxin homeostasis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of new-generation intelligent vehicle technologies will lead to a better level of road safety and CO2 emission reductions. However, the weak point of all these systems is their need for comprehensive and reliable data. For traffic data acquisition, two sources are currently available: 1) infrastructure sensors and 2) floating vehicles. The former consists of a set of fixed point detectors installed in the roads, and the latter consists of the use of mobile probe vehicles as mobile sensors. However, both systems still have some deficiencies. The infrastructure sensors retrieve information fromstatic points of the road, which are spaced, in some cases, kilometers apart. This means that the picture of the actual traffic situation is not a real one. This deficiency is corrected by floating cars, which retrieve dynamic information on the traffic situation. Unfortunately, the number of floating data vehicles currently available is too small and insufficient to give a complete picture of the road traffic. In this paper, we present a floating car data (FCD) augmentation system that combines information fromfloating data vehicles and infrastructure sensors, and that, by using neural networks, is capable of incrementing the amount of FCD with virtual information. This system has been implemented and tested on actual roads, and the results show little difference between the data supplied by the floating vehicles and the virtual vehicles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabajo presenta un estudio sobre el funcionamiento y aplicaciones de las células de combustible de membrana tipo PEM, o de intercambio de protones, alimentadas con hidrógeno puro y oxigeno obtenido de aire comprimido. Una vez evaluado el proceso de dichas células y las variables que intervienen en el mismo, como presión, humedad y temperatura, se presenta una variedad de métodos para la instrumentación de tales variables así como métodos y sistemas para la estabilidad y control de las mismas, en torno a los valores óptimos para una mayor eficacia en el proceso. Tomando como variable principal a controlar la temperatura del proceso, y exponiendo los valores concretos en torno a 80 grados centígrados entre los que debe situarse, es realizado un modelo del proceso de calentamiento y evolución de la temperatura en función de la potencia del calentador resistivo en el dominio de la frecuencia compleja, y a su vez implementado un sistema de medición mediante sensores termopar de tipo K de respuesta casi lineal. La señal medida por los sensores es amplificada de manera diferencial mediante amplificadores de instrumentación INA2126, y es desarrollado un algoritmo de corrección de error de unión fría (error producido por la inclusión de nuevos metales del conector en el efecto termopar). Son incluidos los datos de test referentes al sistema de medición de temperatura , incluyendo las desviaciones o error respecto a los valores ideales de medida. Para la adquisición de datos y implementación de algoritmos de control, es utilizado un PC con el software Labview de National Instruments, que permite una programación intuitiva, versátil y visual, y poder realizar interfaces de usuario gráficas simples. La conexión entre el hardware de instrumentación y control de la célula y el PC se realiza mediante un interface de adquisición de datos USB NI 6800 que cuenta con un amplio número de salidas y entradas analógicas. Una vez digitalizadas las muestras de la señal medida, y corregido el error de unión fría anteriormente apuntado, es implementado en dicho software un controlador de tipo PID ( proporcional-integral-derivativo) , que se presenta como uno de los métodos más adecuados por su simplicidad de programación y su eficacia para el control de este tipo de variables. Para la evaluación del comportamiento del sistema son expuestas simulaciones mediante el software Matlab y Simulink determinando por tanto las mejores estrategias para desarrollar el control PID, así como los posibles resultados del proceso. En cuanto al sistema de calentamiento de los fluidos, es empleado un elemento resistor calentador, cuya potencia es controlada mediante un circuito electrónico compuesto por un detector de cruce por cero de la onda AC de alimentación y un sistema formado por un elemento TRIAC y su circuito de accionamiento. De manera análoga se expone el sistema de instrumentación para la presión de los gases en el circuito, variable que oscila en valores próximos a 3 atmosferas, para ello es empleado un sensor de presión con salida en corriente mediante bucle 4-20 mA, y un convertidor simple corriente a tensión para la entrada al sistema de adquisición de datos. Consecuentemente se presenta el esquema y componentes necesarios para la canalización, calentamiento y humidificación de los gases empleados en el proceso así como la situación de los sensores y actuadores. Por último el trabajo expone la relación de algoritmos desarrollados y un apéndice con información relativa al software Labview. ABTRACT This document presents a study about the operation and applications of PEM fuel cells (Proton exchange membrane fuel cells), fed with pure hydrogen and oxygen obtained from compressed air. Having evaluated the process of these cells and the variables involved on it, such as pressure, humidity and temperature, there is a variety of methods for implementing their control and to set up them around optimal values for greater efficiency in the process. Taking as primary process variable the temperature, and exposing its correct values around 80 degrees centigrade, between which must be placed, is carried out a model of the heating process and the temperature evolution related with the resistive heater power on the complex frequency domain, and is implemented a measuring system with thermocouple sensor type K performing a almost linear response. The differential signal measured by the sensor is amplified through INA2126 instrumentation amplifiers, and is developed a cold junction error correction algorithm (error produced by the inclusion of additional metals of connectors on the thermocouple effect). Data from the test concerning the temperature measurement system are included , including deviations or error regarding the ideal values of measurement. For data acquisition and implementation of control algorithms, is used a PC with LabVIEW software from National Instruments, which makes programming intuitive, versatile, visual, and useful to perform simple user interfaces. The connection between the instrumentation and control hardware of the cell and the PC interface is via a USB data acquisition NI 6800 that has a large number of analog inputs and outputs. Once stored the samples of the measured signal, and correct the error noted above junction, is implemented a software controller PID (proportional-integral-derivative), which is presented as one of the best methods for their programming simplicity and effectiveness for the control of such variables. To evaluate the performance of the system are presented simulations using Matlab and Simulink software thereby determining the best strategies to develop PID control, and possible outcomes of the process. As fluid heating system, is employed a heater resistor element whose power is controlled by an electronic circuit comprising a zero crossing detector of the AC power wave and a system consisting of a Triac and its drive circuit. As made with temperature variable it is developed an instrumentation system for gas pressure in the circuit, variable ranging in values around 3 atmospheres, it is employed a pressure sensor with a current output via 4-20 mA loop, and a single current to voltage converter to adequate the input to the data acquisition system. Consequently is developed the scheme and components needed for circulation, heating and humidification of the gases used in the process as well as the location of sensors and actuators. Finally the document presents the list of algorithms and an appendix with information about Labview software.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La medida de la presión sonora es un proceso de extrema importancia para la ingeniería acústica, de aplicación en numerosas áreas de esta disciplina, como la acústica arquitectónica o el control de ruido. Sobre todo en esta última, es necesario poder efectuar medidas precisas en condiciones muy diversas. Por otra parte, la ubicuidad de los dispositivos móviles inteligentes (smartphones, tabletas, etc.), dispositivos que integran potencia de procesado, conectividad, interactividad y una interfaz intuitiva en un tamaño reducido, abre la posibilidad de su uso como sistemas de medida de calidad y de coste bajo. En este Proyecto se pretende utilizar las capacidades de entrada y salida, procesado, conectividad inalámbrica y geolocalización de los dispositivos móviles basados en iOS, en concreto el iPhone, para implementar un sistema de medidas acústicas que iguale o supere las prestaciones de los sonómetros existentes en el mercado. SonoPhone permitirá, mediante la conexión de un micrófono de medida adecuado, la realización de medidas de acuerdo a las normas técnicas en vigor, así como la posibilidad de programar, configurar y almacenar o trasmitir las medidas realizadas, que además estarán geolocalizadas con el GPS integrado en el dispositivo móvil. También se permitirá enviar los datos de la medida a un almacenamiento remoto en la nube. La aplicación tiene una estructura modular en la que un módulo de adquisición de datos lee la señal del micrófono, un back-end efectúa el procesado necesario, y otros módulos permiten la calibración del dispositivo y programar y configurar las medidas, así como su almacenamiento y transmisión en red. Una interfaz de usuario (GUI) permite visualizar las medidas y efectuar las configuraciones deseadas por el usuario, todo ello en tiempo real. Además de implementar la aplicación, se ha realizado una prueba de funcionamiento para determinar si el hardware del iPhone es adecuado para la medida de la presión acústica de acuerdo a las normas internacionales. Sound pressure measurement is an extremely important process in the field of acoustic engineering, with applications in numerous subfields, like for instance building acoustics and noise control, where it is necessary to be able to accurately measure sound pressure in very diverse (and sometimes adverse) conditions. On the other hand, the growing ubiquity of mobile devices such as smartphones or tablets, which combine processing power, connectivity, interactivity and an intuitive interface in a small size, makes it possible to use these devices as quality low-cost measurement systems. This Project aims to use the input-output capabilities of iOS-based mobile devices, in particular the iPhone, together with their processing power, wireless connectivity and geolocation features, to implement an acoustic measurement system that rivals the performance of existing devices. SonoPhone allows, with the addition of an adequate measurement microphone, to carry out measurements that comply with current technical regulations, as well as programming, configuring, storing and transmitting the results of the measurement. These measurements will be geolocated using the integrated GPS, and can be transmitted effortlessly to a remote cloud storage. The application is structured in modular fashion. A data acquisition module reads the signal from the microphone, while a back-end module carries out the necessary processing. Other modules permit the device to be calibrated, or control the configuration of the measurement and its storage or transmission. A Graphical User Interface (GUI) allows visual feedback on the measurement in progress, and provides the user with real-time control over the measurement parameters. Not only an application has been developed; a laboratory test was carried out with the goal of determining if the hardware of the iPhone permits the whole system to comply with international regulations regarding sound level meters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La mayoría de las aplicaciones forestales del escaneo laser aerotransportado (ALS, del inglés airborne laser scanning) requieren la integración y uso simultaneo de diversas fuentes de datos, con el propósito de conseguir diversos objetivos. Los proyectos basados en sensores remotos normalmente consisten en aumentar la escala de estudio progresivamente a lo largo de varias fases de fusión de datos: desde la información más detallada obtenida sobre un área limitada (la parcela de campo), hasta una respuesta general de la cubierta forestal detectada a distancia de forma más incierta pero cubriendo un área mucho más amplia (la extensión cubierta por el vuelo o el satélite). Todas las fuentes de datos necesitan en ultimo termino basarse en las tecnologías de sistemas de navegación global por satélite (GNSS, del inglés global navigation satellite systems), las cuales son especialmente erróneas al operar por debajo del dosel forestal. Otras etapas adicionales de procesamiento, como la ortorectificación, también pueden verse afectadas por la presencia de vegetación, deteriorando la exactitud de las coordenadas de referencia de las imágenes ópticas. Todos estos errores introducen ruido en los modelos, ya que los predictores se desplazan de la posición real donde se sitúa su variable respuesta. El grado por el que las estimaciones forestales se ven afectadas depende de la dispersión espacial de las variables involucradas, y también de la escala utilizada en cada caso. Esta tesis revisa las fuentes de error posicional que pueden afectar a los diversos datos de entrada involucrados en un proyecto de inventario forestal basado en teledetección ALS, y como las propiedades del dosel forestal en sí afecta a su magnitud, aconsejando en consecuencia métodos para su reducción. También se incluye una discusión sobre las formas más apropiadas de medir exactitud y precisión en cada caso, y como los errores de posicionamiento de hecho afectan a la calidad de las estimaciones, con vistas a una planificación eficiente de la adquisición de los datos. La optimización final en el posicionamiento GNSS y de la radiometría del sensor óptico permitió detectar la importancia de este ultimo en la predicción de la desidad relativa de un bosque monoespecífico de Pinus sylvestris L. ABSTRACT Most forestry applications of airborne laser scanning (ALS) require the integration and simultaneous use of various data sources, pursuing a variety of different objectives. Projects based on remotely-sensed data generally consist in upscaling data fusion stages: from the most detailed information obtained for a limited area (field plot) to a more uncertain forest response sensed over a larger extent (airborne and satellite swath). All data sources ultimately rely on global navigation satellite systems (GNSS), which are especially error-prone when operating under forest canopies. Other additional processing stages, such as orthorectification, may as well be affected by vegetation, hence deteriorating the accuracy of optical imagery’s reference coordinates. These errors introduce noise to the models, as predictors displace from their corresponding response. The degree to which forest estimations are affected depends on the spatial dispersion of the variables involved and the scale used. This thesis reviews the sources of positioning errors which may affect the different inputs involved in an ALS-assisted forest inventory project, and how the properties of the forest canopy itself affects their magnitude, advising on methods for diminishing them. It is also discussed how accuracy should be assessed, and how positioning errors actually affect forest estimation, toward a cost-efficient planning for data acquisition. The final optimization in positioning the GNSS and optical image allowed to detect the importance of the latter in predicting relative density in a monospecific Pinus sylvestris L. forest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrical power distribution and commercialization scenario is evolving worldwide, and electricity companies, faced with the challenge of new information requirements, are demanding IT solutions to deal with the smart monitoring of power networks. Two main challenges arise from data management and smart monitoring of power networks: real-time data acquisition and big data processing over short time periods. We present a solution in the form of a system architecture that conveys real time issues and has the capacity for big data management.