491 resultados para Rachael Craw


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study adds to the literature as it examines the experiences that international postgraduate (IP) students have with a peer-mentoring program at an Australian University. To analyse transition and peer mentoring thirty-four (34) semi-structured interviews with IP students from Indian, Chinese and other national cohorts were conducted. The study found that transitioning IP students who had a mentor, benefitted as it provided a variety of support mechanisms so that IP students could transition to the next stage. Transition was important for mentors who were able to develop greater self-confidence, graduate attributes and other employability skills.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study examines the experiences of international postgraduate (IP) student’s transition at a university, and adds to the literature as it focuses on student-based support for transition where mostly past research has focused on university-based support. The study utilises social support theory (House, 1981) and Illeris’ (2002) concepts on learning to explain why students transition. A qualitative methodology was used where 48 students were interviewed. It was found that IP students experienced negative transition experiences in the beginning, but adjusted as time went on. Involvement in the student society was beneficial for transition, as it gave students the opportunity to make friends, and these friends, in turn, give students social support, which assists with their learning and transition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is a conceptual and methodological review of the literature on the impact of TV on preschoolers' weight status. A systematic search, of papers published between January 1995 and January 2010, identified twenty-six relevant studies. Fifteen of these were cross-sectional in design and eleven adopted a prospective design; a positive association between hours of TV and child adiposity was found in all but three studies. Although assessed in a limited number of studies, diet may mediate the relationship between TV viewing and BMI. Another likely mediator may be the content of TV programs watched; only three studies examined this association and findings were inconsistent. Our review revealed that research examining mediating effects is limited, focusing more on simple cross-sectional or prospective relationships between TV habits and child body mass index. Further investigation of the mechanisms by which TV viewing affects preschool weight gain is needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. This non-dispensing cross-over study was conducted to determine if lenses presoaked in Opti-Free RepleniSH (OFR) or ReNu MultiPlus (RMP) cause solution-induced corneal staining (SICS) and subsequent cell sloughing before the typical 2 h in vivo examination point.

Methods. Study lenses (PureVision) were worn bilaterally by 13 participants for periods of 15, 30, 60, and 120 min using two different contralateral care regimen pairings. The lens worn on the test eye was soaked overnight in either OFR or RMP and the control eye in Clear Care (CC). After lens removal, corneal staining was rated on a scale of 0 (negligible) to 100 (severe) for four peripheral quadrants and the central region, and the differential global staining score was calculated by subtracting baseline staining scores. Following the staining assessment, corneal cells were collected from the ocular surface using a non-contact irrigation system to determine ocular cell shedding rates.

Results. Differential global staining score with OFR was greater than CC with the differences being statistically significant at 30 and 60 min (p < 0.01). Maximum staining with RMP was significantly greater than OFR and peaked after 60 and 120 min of lens wear (p < 0.01). On average, 710 ± 470 ocular cells were collected after lens wear, with similar shedding seen independent of solution or lens wear duration (p > 0.05).

Conclusions. SICS occurred earlier but to a significantly lower degree when PureVision lenses were presoaked in OFR compared with RMP, while lenses presoaked in CC did not cause SICS. Ocular surface cell shedding after lens removal was not impacted by lens wear durations of <=2 h.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To review the effects of contact lenses on the corneal surface.

Methods: A review of the literature and in-house research of corneal staining and its various forms of presentation.

Results: Corneal staining manifests in many different forms. The severity of staining or insult of the cornea is usually determined by the extent (area of coverage), density, and depth. The cause of staining is multifactorial, and its location is often linked to the type of lens that is being worn, the solution used to clean/disinfect the lens, the state of hydration of the soft lens, and the state of the cornea that has been affected by the lens.

Conclusions: Sodium fluorescein dye effectively highlights corneal integrity changes referred to as corneal staining. This review describes the manifestations, the cause, the mechanisms, and the methods of remediation of corneal staining.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the compatibility of a new silicone hydrogel lens, asmofilcon A (with four multipurpose disinfecting solutions: OPTIFREE RepleniSH, ReNu MultiPlus, Solo-Care Aqua and MeniCare Soft). Ocular responses and subjective responses were monitored with each lens-care system combination.

Methods: The study was conducted as a prospective, bilateral, clinical trial with a single-masked investigator, and randomized cross-over design with four phases, (one for each care system). Each study phase comprised of two consecutive days of lens wear where the lenses were inserted on day 1 directly from the blister-packs and worn for over 8 hr, then inserted on day 2 after overnight disinfection with one of the study lens care systems. Twenty-five adapted soft contact lens wearers who were able to wear their habitual lenses comfortably for more than 12 hr were recruited.

Results: There were statistically significant differences in corneal staining found for all the lens-care systems when comparing the results of day 1 (from the blister pack) with day 2 (following care system use) (P < 0.05). ReNu MultiPlus solution had the highest grade for corneal staining at the 2-hr time point on day 2 which then decreased by 6 hr (P < 0.05). There was no difference between the lens care systems and the rating of subjective comfort over either of the two days. The rating of dryness and burning sensations were only slightly increased at 6 hr for all lens care systems except ReNu MultiPlus where burning was highest on insertion (P < 0.05).

Conclusion: Corneal staining observed in this study does not seem to have been related to the presence of polyhexamethylene biguanide (0.0001% wv) that was present in three of the four care systems. Only one care system (ReNu MultiPlus) demonstrated an associated level of corneal staining that was statistically significant; however, this was not considered to be of clinical relevance. These results suggest that using this novel surface-treated silicone hydrogel lens may result in less lens and lens care-related interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To report the development of a new apparatus for non-invasive collection of human corneal epithelial cells.

Methods. Previous methods of non-invasive, irrigative corneal cell collection resulted in low cell yields limiting potential analysis. A new ocular surface cell collection apparatus (OSCCA) was designed to collect more epithelial cells from direct irrigation of the corneal surface to allow for clinical comparisons. Forty-five samples were obtained (unilateral or bilateral over seven visits) from five human participants. Cell yield, size, phenotype, and corneal staining (prior and post eye wash) were examined.

Results. On average 364 ± 230 epithelial cells were collected from the cornea per eye. Epithelial cell sizes ranged from 8.21 to 51.69 μm in diameter, and 67.30 to 2098.85 μm2 area. The proportion of corneal specific cells collected per sample was 75 ± 14% as determined by positive K3 expression with AE5. On average, 77 ± 0.2% of epithelial cells harvested were nucleated, the remainder were non-nucleated ghost cells. Corneal staining was reduced in the OSCCA-washed vs. contralateral non-washed eyes (p = 0.02).

Conclusions. The OSCCA allows collection of human corneal epithelial cells with significantly higher yields, and greater specificity than previously reported. Reduced corneal staining observed post eye-wash demonstrated the safety of the technique, and its ability to remove cells directly from the corneal surface. The OSCCA could provide an objective non-invasive method of investigating pathological changes, effects of topical therapeutics, and impact of contact lenses and care-solutions of the cells of the ocular surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To investigate whether the inclusion of a rub and rinse step before contact lens disinfection has an impact on solution-induced corneal staining.

Methods. This was a prospective, double-masked, single investigator study. Twenty participants were recruited for two visits, where balafilcon-A lenses were worn bilaterally for 2 h. Each pair of lenses was prepared using two different methodologies. The “control” lens was transferred from the blister pack directly into a storage case containing polyhexamethylene biguanide-based lens care solution. The contralateral “test” lens was rubbed and simultaneously rinsed using the same polyhexamethylene biguanide-based care solution, for either 60 s (visit 1) or 20 s (visit 2). Both lenses were then soaked in the solution overnight. After baseline corneal staining assessments, the lenses were inserted following a randomized contralateral model. After 2 h, lenses were removed, corneal staining was regraded, and comfort scores were obtained.

Results. Rubbed and rinsed test lenses induced significantly less corneal staining than control lenses for all participants during visit 1 (mean ± SD: 516 ± 843 vs. 2170 ± 902; p < 0.001) and visit 2 (522 ± 417 vs. 2091 ± 965; p < 0.001). There was no significant difference between the test lenses during visits 1 and 2 (p = 0.72) or controls (p = 0.50). Comfort scores did not differ between eyes (p > 0.05).

Conclusions. Corneal staining induced after 2 h of lens wear with the combination of balafilcon-A and polyhexamethylene biguanide-based lens care solution can be significantly reduced by including a rub and rinse step before overnight soaking. Further work is required to establish the longevity of this effect during the monthly wearing cycle.

Relevância:

10.00% 10.00%

Publicador: