918 resultados para ROBOTIC ARM


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study tests whether cognitive failures mediate effects of work-related time pressure and time control on commuting accidents and near-accidents. Participants were 83 employees (56% female) who each commuted between their regular place of residence and place of work using vehicles. The Workplace Cognitive Failure Scale (WCFS) asked for the frequency of failure in memory function, failure in attention regulation, and failure in action execution. Time pressure and time control at work were assessed by the Instrument for Stress Oriented Task Analysis (ISTA). Commuting accidents in the last 12 months were reported by 10% of participants, and half of the sample reported commuting near-accidents in the last 4 weeks. Cognitive failure significantly mediated the influence of time pressure at work on near-accidents even when age, gender, neuroticism, conscientiousness, commuting duration, commuting distance, and time pressure during commuting were controlled for. Time control was negatively related to cognitive failure and neuroticism, but no association with commuting accidents or near-accidents was found. Time pressure at work is likely to increase cognitive load. Time pressure might, therefore, increase cognitive failures during work and also during commuting. Hence, time pressure at work can decrease commuting safety. The result suggests a reduction of time pressure at work should improve commuting safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of image-guided systems with or without support by surgical robots relies on the accuracy of the navigation process, including patient-to-image registration. The surgeon must carry out the procedure based on the information provided by the navigation system, usually without being able to verify its correctness beyond visual inspection. Misleading surrogate parameters such as the fiducial registration error are often used to describe the success of the registration process, while a lack of methods describing the effects of navigation errors, such as those caused by tracking or calibration, may prevent the application of image guidance in certain accuracy-critical interventions. During minimally invasive mastoidectomy for cochlear implantation, a direct tunnel is drilled from the outside of the mastoid to a target on the cochlea based on registration using landmarks solely on the surface of the skull. Using this methodology, it is impossible to detect if the drill is advancing in the correct direction and that injury of the facial nerve will be avoided. To overcome this problem, a tool localization method based on drilling process information is proposed. The algorithm estimates the pose of a robot-guided surgical tool during a drilling task based on the correlation of the observed axial drilling force and the heterogeneous bone density in the mastoid extracted from 3-D image data. We present here one possible implementation of this method tested on ten tunnels drilled into three human cadaver specimens where an average tool localization accuracy of 0.29 mm was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HYPOTHESIS Facial nerve monitoring can be used synchronous with a high-precision robotic tool as a functional warning to prevent of a collision of the drill bit with the facial nerve during direct cochlear access (DCA). BACKGROUND Minimally invasive direct cochlear access (DCA) aims to eliminate the need for a mastoidectomy by drilling a small tunnel through the facial recess to the cochlea with the aid of stereotactic tool guidance. Because the procedure is performed in a blind manner, structures such as the facial nerve are at risk. Neuromonitoring is a commonly used tool to help surgeons identify the facial nerve (FN) during routine surgical procedures in the mastoid. Recently, neuromonitoring technology was integrated into a commercially available drill system enabling real-time monitoring of the FN. The objective of this study was to determine if this drilling system could be used to warn of an impending collision with the FN during robot-assisted DCA. MATERIALS AND METHODS The sheep was chosen as a suitable model for this study because of its similarity to the human ear anatomy. The same surgical workflow applicable to human patients was performed in the animal model. Bone screws, serving as reference fiducials, were placed in the skull near the ear canal. The sheep head was imaged using a computed tomographic scanner and segmentation of FN, mastoid, and other relevant structures as well as planning of drilling trajectories was carried out using a dedicated software tool. During the actual procedure, a surgical drill system was connected to a nerve monitor and guided by a custom built robot system. As the planned trajectories were drilled, stimulation and EMG response signals were recorded. A postoperative analysis was achieved after each surgery to determine the actual drilled positions. RESULTS Using the calibrated pose synchronized with the EMG signals, the precise relationship between distance to FN and EMG with 3 different stimulation intensities could be determined for 11 different tunnels drilled in 3 different subjects. CONCLUSION From the results, it was determined that the current implementation of the neuromonitoring system lacks sensitivity and repeatability necessary to be used as a warning device in robotic DCA. We hypothesize that this is primarily because of the stimulation pattern achieved using a noninsulated drill as a stimulating probe. Further work is necessary to determine whether specific changes to the design can improve the sensitivity and specificity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work addresses the evolution of an artificial neural network (ANN) to assist in the problem of indoor robotic localization. We investigate the design and building of an autonomous localization system based on information gathered from wireless networks (WN). The article focuses on the evolved ANN, which provides the position of a robot in a space, as in a Cartesian coordinate system, corroborating with the evolutionary robotic research area and showing its practical viability. The proposed system was tested in several experiments, evaluating not only the impact of different evolutionary computation parameters but also the role of the transfer functions on the evolution of the ANN. Results show that slight variations in the parameters lead to significant differences on the evolution process and, therefore, in the accuracy of the robot position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Small-cell lung cancer (SCLC) is a highly vascularized tumor. ASA404 is a tumor vascular disrupting agent. This is the first trial to report the effects of combining chemotherapy with ASA404 in SCLC. METHODS Patients with untreated metastatic SCLC were treated with carboplatin (area under curve, 6) plus paclitaxel (175 mg/m(2)) plus ASA404 (1800 mg/m(2)) on day 1 every 21 days for up to 6 cycles. The primary endpoint was the progression-free survival (PFS) rate at 24 weeks. RESULTS Median age was 61 years; 53% were women, 41% had weight loss; and 96% had a performance status of 0-1. Twelve patients completed all 6 cycles, and most adverse events were related to chemotherapy. Median PFS and time to progression were 7.0 months (95% CI, 5.7-9.4 months) and 7.5 months (95% CI, 5.7-9.4 months), respectively. The progression-free survival (PFS) rate at 24 weeks was 41% (95% CI, 18%-65%). The overall response rate was 94%. The median overall survival time was 14.2 months (95% CI, 8.2-16.0 months) and 1-year survival was 57%. The median follow-up time was 17.7 months. Due to negative results with ASA404 in non-small-cell lung cancer trials, the trial was stopped prematurely after 17 of 56 planned patients were being accrued. CONCLUSIONS This is the first report of a clinical trial with a vascular disrupting agent in SCLC. No unexpected toxicity was observed. PFS was not prolonged with carboplatin and paclitaxel plus ASA404.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. MATERIAL AND METHODS Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. RESULTS Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. CONCLUSIONS The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Angiographic C-arm CT may allow performing percutaneous stereotactic tumor ablations in the interventional radiology suite. Our purpose was to evaluate the accuracy of using C-arm CT for single and multimodality image fusions and to compare the targeting accuracy of liver lesions with the reference standard of MDCT. MATERIALS AND METHODS C-arm CT and MDCT scans were obtained of a nonrigid rapid prototyping liver phantom containing five 1-mm targets that were placed under skin-simulating deformable plastic foam. Target registration errors of image fusion were evaluated for single-modality and multimodality image fusions. A navigation system and stereotactic aiming device were used to evaluate target positioning errors on postinterventional scans with the needles in place fused with the C-arm CT or MDCT planning images. RESULTS Target registration error of the image fusion showed no significant difference (p > 0.05) between both modalities. In five series with a total of 25 punctures for each modality, the lateral target positioning error (i.e., the lateral distance between the needle tip and the planned trajectory) was similar for C-arm CT (mean [± SD], 1.6 ± 0.6 mm) and MDCT (1.82 ± .97 mm) (p = 0.33). CONCLUSION In a nonrigid liver phantom, angiographic C-arm CT may provide similar image fusion accuracy for comparison of intra- and postprocedure control images with the planning images and enables stereotactic targeting accuracy similar to that of MDCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Robot-assisted therapy offers a promising approach to neurorehabilitation, particularly for severely to moderately impaired stroke patients. The objective of this study was to investigate the effects of intensive arm training on motor performance in four chronic stroke patients using the robot ARMin II. METHODS: ARMin II is an exoskeleton robot with six degrees of freedom (DOF) moving shoulder, elbow and wrist joints. Four volunteers with chronic (>or= 12 months post-stroke) left side hemi-paresis and different levels of motor severity were enrolled in the study. They received robot-assisted therapy over a period of eight weeks, three to four therapy sessions per week, each session of one hour.Patients 1 and 4 had four one-hour training sessions per week and patients 2 and 3 had three one-hour training sessions per week. Primary outcome variable was the Fugl-Meyer Score of the upper extremity Assessment (FMA), secondary outcomes were the Wolf Motor Function Test (WMFT), the Catherine Bergego Scale (CBS), the Maximal Voluntary Torques (MVTs) and a questionnaire about ADL-tasks, progress, changes, motivation etc. RESULTS: Three out of four patients showed significant improvements (p < 0.05) in the main outcome. The improvements in the FMA scores were aligned with the objective results of MVTs. Most improvements were maintained or even increased from discharge to the six-month follow-up. CONCLUSION: Data clearly indicate that intensive arm therapy with the robot ARMin II can significantly improve motor function of the paretic arm in some stroke patients, even those in a chronic state. The findings of the study provide a basis for a subsequent controlled randomized clinical trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Task-oriented, repetitive and intensive arm training can enhance arm rehabilitation in patients with paralyzed upper extremities due to lesions of the central nervous system. There is evidence that the training duration is a key factor for the therapy progress. Robot-supported therapy can improve the rehabilitation allowing more intensive training. This paper presents the kinematics, the control and the therapy modes of the arm therapy robot ARMin. It is a haptic display with semi-exoskeleton kinematics with four active and two passive degrees of freedom. Equipped with position, force and torque sensors the device can deliver patient-cooperative arm therapy taking into account the activity of the patient and supporting him/her only as much as needed. The haptic display is combined with an audiovisual display that is used to present the movement and the movement task to the patient. It is assumed that the patient-cooperative therapy approach combined with a multimodal display can increase the patient's motivation and activity and, therefore, the therapeutic progress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Mechanical thrombectomy using stent retriever devices have been advocated to increase revascularization in intracranial vessel occlusion. We present the results of a large prospective study on the use of the Solitaire Flow Restoration in patients with acute ischemic stroke. METHODS Solitaire Flow Restoration Thrombectomy for Acute Revascularization was an international, multicenter, prospective, single-arm study of Solitaire Flow Restoration thrombectomy in patients with large vessel anterior circulation strokes treated within 8 hours of symptom onset. Strict criteria for site selection were applied. The primary end point was the revascularization rate (thrombolysis in cerebral infarction ≥2b) of the occluded vessel as determined by an independent core laboratory. The secondary end point was the rate of good functional outcome (defined as 90-day modified Rankin scale, 0-2). RESULTS A total of 202 patients were enrolled across 14 comprehensive stroke centers in Europe, Canada, and Australia. The median age was 72 years, 60% were female patients. The median National Institute of Health Stroke Scale was 17. Most proximal intracranial occlusion was the internal carotid artery in 18%, and the middle cerebral artery in 82%. Successful revascularization was achieved in 79.2% of patients. Device and procedure-related severe adverse events were found in 7.4%. Favorable neurological outcome was found in 57.9%. The mortality rate was 6.9%. Any intracranial hemorrhagic transformation was found in 18.8% of patients, 1.5% were symptomatic. CONCLUSIONS In this single-arm study, treatment with the Solitaire Flow Restoration device in intracranial anterior circulation occlusions results in high rates of revascularization, low risk of clinically relevant procedural complications, and good clinical outcomes in combination with low mortality at 90 days. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Robotic-assisted laparoscopic surgery (RALS) is evolving as an important surgical approach in the field of colorectal surgery. We aimed to evaluate the learning curve for RALS procedures involving resections of the rectum and rectosigmoid. METHODS: A series of 50 consecutive RALS procedures were performed between August 2008 and September 2009. Data were entered into a retrospective database and later abstracted for analysis. The surgical procedures included abdominoperineal resection (APR), anterior rectosigmoidectomy (AR), low anterior resection (LAR), and rectopexy (RP). Demographic data and intraoperative parameters including docking time (DT), surgeon console time (SCT), and total operative time (OT) were analyzed. The learning curve was evaluated using the cumulative sum (CUSUM) method. RESULTS: The procedures performed for 50 patients (54% male) included 25 AR (50%), 15 LAR (30%), 6 APR (12%), and 4 RP (8%). The mean age of the patients was 54.4 years, the mean BMI was 27.8 kg/m(2), and the median American Society of Anesthesiologists (ASA) classification was 2. The series had a mean DT of 14 min, a mean SCT of 115.1 min, and a mean OT of 246.1 min. The DT and SCT accounted for 6.3% and 46.8% of the OT, respectively. The SCT learning curve was analyzed. The CUSUM(SCT) learning curve was best modeled as a parabola, with equation CUSUM(SCT) in minutes equal to 0.73 × case number(2) - 31.54 × case number - 107.72 (R = 0.93). The learning curve consisted of three unique phases: phase 1 (the initial 15 cases), phase 2 (the middle 10 cases), and phase 3 (the subsequent cases). Phase 1 represented the initial learning curve, which spanned 15 cases. The phase 2 plateau represented increased competence with the robotic technology. Phase 3 was achieved after 25 cases and represented the mastery phase in which more challenging cases were managed. CONCLUSIONS: The three phases identified with CUSUM analysis of surgeon console time represented characteristic stages of the learning curve for robotic colorectal procedures. The data suggest that the learning phase was achieved after 15 to 25 cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total restorative proctocolectomy with ileal pouch-anal anastomosis (RP/IPAA) has become the standard of care for the surgical treatment of ulcerative colitis. Despite its correlation with an excellent quality of life and favorable long-term outcomes, RP/IPAA has been associated with several complications. Prolapse of the ileoanal pouch is a rare and debilitating complication that should be considered in the differential diagnosis of pouch failure. Limited data exist regarding the prevalence and treatment of pouch prolapse. We present the case of a recurrent J-pouch prolapse treated with a novel minimally invasive "salvage" approach involving a robotic-assisted laparoscopic rectopexy with mesh.