989 resultados para Pump-probe technique
Resumo:
In the last decades TiAlN coatings deposited by PVD techniques have been extensively investigated but, nowadays, their potential development for tribological applications is relatively low. However, new coatings are emerging based on them, trying to improve wear behavior. TiAlSiN thin coatings are now investigated, analyzing if Si introduction increases the wear resistance of PVD films. Attending to the application, several wear test configurations has been recently used by some researchers. In this work, TiAlSiN thin coatings were produced by PVD Unbalanced Magnetron Sputtering technique and they were conveniently characterized using Scanning Electron Microscopy (SEM) provided with Energy Dispersive Spectroscopy (EDS), Atomic Force Microscopy (AFM), Electron Probe Micro-Analyzer (EPMA), Micro Hardness (MH) and Scratch Test Analysis. Properties as morphology, thickness, roughness, chemical composition and structure, hardness and film adhesion to the substrate were investigated. Concerning to wear characterization, two very different ways were chosen: micro-abrasion with ball-on-flat configuration and industrial non-standardized tests based on samples inserted in a feed channel of a selected plastic injection mould working with 30% (wt.) glass fiber reinforced polypropylene. TiAlSiN coatings with a small amount of about 5% (wt.) Si showed a similar wear behavior when compared with TiAlN reported performances, denoting that Si addition does not improve the wear performance of the TiAlN coatings in these wear test conditions.
Resumo:
Titanium Diboride (TiB2) presents high mechanical and physical properties. Some wear studies were also carried out in order to evaluate its tribological properties. One of the most popular wear tests for thin films is the ball-cratering configuration. This work was focused on the study of the tribological properties of TiB2 thin films using micro-abrasion tests and following the BS EN 1071-6: 2007 standard. Due to high hardness usually patented by these films, diamond was selected as abrasive on micro-abrasion tests. Micro-abrasion wear tests were performed under five different durations, using the same normal load, speed rotation and ball. Films were deposited by unbalanced magnetron sputtering Physical Vapour Deposition (PVD) technique using TiB2 targets. TiB2 films were characterized using different methods as Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Atomic Force Microscopy (AFM), X-ray Diffraction (XRD), Electron Probe Micro-Analyser (EPMA), Ultra Micro Hardness and Scratch-test Analysis, allowing to confirm that TiB2 presents adequate mechanical and physical properties. Ratio between hardness (coating and abrasive particles), wear resistance and wear coefficient were studied, showing that TiB2 films shows excellent properties for tribological applications.
Resumo:
This paper analyzes the signals captured during impacts and vibrations of a mechanical manipulator. To test the impacts, a flexible beam is clamped to the end-effector of a manipulator that is programmed in a way such that the rod moves against a rigid surface. Eighteen signals are captured and theirs correlation are calculated. A sensor classification scheme based on the multidimensional scaling technique is presented.
Resumo:
Electronics Letters Vol.38, nº 19
Resumo:
Chagas'disease has been described as the commonest form of chronic myocarditis. An immunologic pathogenesis has been discribed for this form of the disease. So far, no immunoperoxidase technique has been used for the detection of immunological deposits in chronic experimental Chagas'myocardiopathy. Forty-one Swiss mice, three months old were inoculated intraperitoneally with doses between 10 and 10(5) Tulahuen trypomastigotes. Mice were reinoculated one month after with doses between 10² and 10(5) and sacrificed at 6 (n=21) and 9 months (n=9) after the first inoculation. ECGs were recorded before sacrifice. Immunoperoxidase technique (peroxidase-antiperoxidase method), immunofluorescence (direct and indirect) as well as histological studies were performed in myocardiums and skeletal muscles of the surviving animals. The most sensitive methods for detecting chronic chagasic infection were the routine histologic studies (73%) and the ECGs 83% and 89% on 6 and 9 mo. post-infected mice, respectively. Myocardial involvement varied from interstitial mild focal lymphocyte infiltrates up to replacement of myocytes by loose connective tissue. Atrial myocardiums (21/23, 91%) were more affected than ventricles (9/23, 39%). Typical chagasic nests were rarely found. Skeletal muscle involvement (11/18 and 7/9) varied from mild to extensive lymphocyte and plasmacell infiltrates, and necrotic fibers. The involved antigen were shown in skeletal muscles by the immunoperoxidase technique as diffusely arranged granular intracytoplasmatic deposit for both IgC and total immunoglobulins. The coincidence between this technique and histologic muscle lesions was 11/18 (61(%) in 6 mo. and 6/8 (75%) at 9 mo. post-infection. In heart, delicate granular deposits of total immunoglobulins were seen diffusely arranged within the ventricular myocytes; coincidence between immunoperoxidase technique anl histologic involvement increased from 36 to 66% in animals sacrifeced 6 and 9 mo. post-infection. This strongly stressed the increase of immunologic phenomena with the chronification of infection. Concerning sensitivity, immunoperoxidase and direct immunofluorescence were highly sensitive in skeletal muscle (100%, p < 0.01). Conversely, direct immunofluorescence technique showed poor results in heart while immunoperoxidase increased its sensitivity from 21.4% (at 6 mo.) to 66.6% (at 9 mo.) post-infection (p < 0.001). Considering the necessity of obtaining an adequate vaccine in order to prevent this disease an experimental model like this, rendering immunological reactions as revealed by the immunoperoxidase technique, would be useful.
Resumo:
A clinical trial involving 80 patients of both sexes, from ages 15 to 55, with chronic intestinal or hepatointestinal schistosomiasis mansoni, was carried out to evaluate the therapeutical efficacy of different dose regimens of praziquantel. The patients were randomly allocated into four groups with an equal number of cases and were then treated with one of the following dosages: 60 mg/kg for 1 day; 60 mg/kg daily for 2 days; 60 mg/kg daily for 3 days; and 30 mg/kg daily for 6 days. The assessment of parasitological cure was based on the quantitative oogram technique through rectal mucosa biopsies which were undertaken prior to, as well as, 1,2,4 and 6 months post-treatment. Concurrently, stool examinations according to the qualitative Hoffman, Pons & Janer (HPJ) and the quantitative Kato-Katz (K-K) methods were also performed. The best tolerability was observed with 30 mg/kg daily for 6 days whereas the highest incidence of side-effects (mainly dizziness and nausea) was found with 60 mg/kg daily for 3 days. No serious adverse drug reaction has occurred. The achieved cure rates were: 25% with 60 mg/kg for 1 day; 60% with 60 mg/kg daily for 2 days; 89.5% with 60 mg/kg daily for 3 days; and 90% with 30 mg/kg daily for 6 days. At the same time there has been a downfall of 64%, 73%, 87% and 84% respectively, in the median number of viable S. mansoni ova per gram of tissue. Thus, a very clear direct correlation between dose and effect could be seen. The corresponding cure rates according to stool examinations by HPJ were 39%, 80%, 100% and 95%; by K-K 89%, 100%, 100% and 100%. This discrepancy in results amongst the three parasitological methods is certainly due to their unequal accuracy. In fact, when the number of viable eggs per gram of tissue fell below 5,000 the difference in the percentage of false negative findings between HPJ (28%) and K-K (80%) became significative. When this number dropped to less than 2,000 the percentage of false negative results obtained with HPJ (49%) turned significant in relation to the oogram as well. In conclusion, it has been proven that praziquantel is a highly efficacious agent against S. mansoni infections. If administered at a total dose of 180 mg/kg divided into either 3 or 6 days, it yields a 90% cure rate. Possibly, one could reach 100% by increasing the total dose to 240 mg/kg. Furthermore, it was confirmed that the quantitative oogram technique is the most reliable parasitological method when evaluating the efficacy of new drugs in schistosomiasis mansoni.
Resumo:
IEEE International Symposium on Circuits and Systems, pp. 232 – 235, Seattle, EUA
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e Computadores
Resumo:
TiO2 films have been deposited on ITO substrates by dc reactive magnetron sputtering technique. It has been found that the sputtering pressure is a very important parameter for the structure of the deposited TiO2 films. When the pressure is lower than 1 Pa, the deposited has a dense structure and shows a preferred orientation along the [101] direction. However, the nanorod structure has been obtained as the sputtering pressure is higher than 1 Pa. These nanorods structure TiO2 film shows a preferred orientation along the [110] direction. The x-ray diffraction and the Raman scattering measurements show both the dense and the nanostructure TiO2 films have only an anatase phase, no other phase has been obtained. The results of the SEM show that these TiO2 nanorods are perpendicular to the ITO substrate. The TEM measurement shows that the nanorods have a very rough surface. The dye-sensitized solar cells (DSSCs) have been assembled using these TiO2 nanorod films prepared at different sputtering pressures as photoelectrode. And the effect of the sputtering pressure on the properties of the photoelectric conversion of the DSSCs has been studied.
Resumo:
Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Reporter genes are routinely used in every laboratory for molecular and cellular biology for studying heterologous gene expression and general cellular biological mechanisms, such as transfection processes. Although well characterized and broadly implemented, reporter genes present serious limitations, either by involving time-consuming procedures or by presenting possible side effects on the expression of the heterologous gene or even in the general cellular metabolism. Fourier transform mid-infrared (FT-MIR) spectroscopy was evaluated to simultaneously analyze in a rapid (minutes) and high-throughput mode (using 96-wells microplates), the transfection efficiency, and the effect of the transfection process on the host cell biochemical composition and metabolism. Semi-adherent HEK and adherent AGS cell lines, transfected with the plasmid pVAX-GFP using Lipofectamine, were used as model systems. Good partial least squares (PLS) models were built to estimate the transfection efficiency, either considering each cell line independently (R 2 ≥ 0.92; RMSECV ≤ 2 %) or simultaneously considering both cell lines (R 2 = 0.90; RMSECV = 2 %). Additionally, the effect of the transfection process on the HEK cell biochemical and metabolic features could be evaluated directly from the FT-IR spectra. Due to the high sensitivity of the technique, it was also possible to discriminate the effect of the transfection process from the transfection reagent on KEK cells, e.g., by the analysis of spectral biomarkers and biochemical and metabolic features. The present results are far beyond what any reporter gene assay or other specific probe can offer for these purposes.
Resumo:
Summary form only given. Bacterial infections and the fight against them have been one of the major concerns of mankind since the dawn of time. During the `golden years' of antibiotic discovery, during the 1940-90s, it was thought that the war against infectious diseases had been won. However currently, due to the drug resistance increase, associated with the inefficiency of discovering new antibiotic classes, infectious diseases are again a major public health concern. A potential alternative to antibiotic treatments may be the antimicrobial photodynamic inactivation (PDI) therapy. To date no indication of antimicrobial PDI resistance development has been reported. However the PDI protocol depends on the bacteria species [1], and in some cases on the bacteria strains, for instance Staphylococcus aureus [2]. Therefore the development of PDI monitoring techniques for diverse bacteria strains is critical in pursuing further understanding of such promising alternative therapy. The present works aims to evaluate Fourier-Transformed-Infra-Red (FT-IR) spectroscopy to monitor the PDI of two model bacteria, a gram-negative (Escherichia coli) and a gram-positive (S. aureus) bacteria. For that a high-throughput FTIR spectroscopic method was implemented as generally described in Scholz et al. [3], using short incubation periods and microliter quantities of the incubation mixture containing the bacteria and the PDI-drug model the known bactericidal tetracationic porphyrin 5,10,15,20-tetrakis (4-N, N, Ntrimethylammoniumphenyl)-porphyrin p-tosylate (TTAP4+). In both bacteria models it was possible to detect, by FTIR-spectroscopy, the drugs effect on the cellular composition either directly on the spectra or on score plots of principal component analysis. Furthermore the technique enabled to infer the effect of PDI on the major cellular biomolecules and metabolic status, for example the turn-over metabolism. In summary bacteria PDI was monitored in an economic, rapid (in minutes- , high-throughput (using microplates with 96 wells) and highly sensitive mode resourcing to FTIR spectroscopy, which could serve has a technological basis for the evaluation of antimicrobial PDI therapies efficiency.
Resumo:
BACKGROUNDWhile the pharmaceutical industry keeps an eye on plasmid DNA production for new generation gene therapies, real-time monitoring techniques for plasmid bioproduction are as yet unavailable. This work shows the possibility of in situ monitoring of plasmid production in Escherichia coli cultures using a near infrared (NIR) fiber optic probe. RESULTSPartial least squares (PLS) regression models based on the NIR spectra were developed for predicting bioprocess critical variables such as the concentrations of biomass, plasmid, carbon sources (glucose and glycerol) and acetate. In order to achieve robust models able to predict the performance of plasmid production processes, independently of the composition of the cultivation medium, cultivation strategy (batch versus fed-batch) and E. coli strain used, three strategies were adopted, using: (i) E. coliDH5 cultures conducted under different media compositions and culture strategies (batch and fed-batch); (ii) engineered E. coli strains, MG1655endArecApgi and MG1655endArecA, grown on the same medium and culture strategy; (iii) diverse E. coli strains, over batch and fed-batch cultivations and using different media compositions. PLS models showed high accuracy for predicting all variables in the three groups of cultures. CONCLUSIONNIR spectroscopy combined with PLS modeling provides a fast, inexpensive and contamination-free technique to accurately monitoring plasmid bioprocesses in real time, independently of the medium composition, cultivation strategy and the E. coli strain used.
Resumo:
One of the most challenging task underlying many hyperspectral imagery applications is the linear unmixing. The key to linear unmixing is to find the set of reference substances, also called endmembers, that are representative of a given scene. This paper presents the vertex component analysis (VCA) a new method to unmix linear mixtures of hyperspectral sources. The algorithm is unsupervised and exploits a simple geometric fact: endmembers are vertices of a simplex. The algorithm complexity, measured in floating points operations, is O (n), where n is the sample size. The effectiveness of the proposed scheme is illustrated using simulated data.