950 resultados para Prosthodontic rehabilitation of maxillary defects


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this literature review is to discuss the use of dental implants in growing patients and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended to wait for the completion of dental and skeletal growth, except for severe cases of ectodermal dysplasia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article reports the 9-year clinical outcome of the two-stage surgical rehabilitation of a severely atrophic edentulous maxilla with a metal-resin fixed denture supported by implants anchored in the zygomatic bone and the maxilla. After clinical and radiographic examination, zygomatic implants were inserted bilaterally and four standard implants were placed in the anterior region of the maxilla. Six months later, the implants were loaded with a provisional acrylic resin denture, and the definitive implant-supported metal-resin fixed denture was provided 1 year after implant placement. After 9 years of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. In the present case, the rehabilitation of severe maxillary atrophy using the zygomatic bone as a site for implant anchorage provided good long-term functional and esthetic results. Therefore, with proper case selection, correct indication, and knowledge of the surgical technique, the use of zygomatic implants associated with standard implants offers advantages in the rehabilitation of severely resorbed maxillae, especially in areas with inadequate bone quality and volume, without needing an additional bone grafting surgery, thereby shortening or avoiding hospital stay and reducing surgical morbidity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of all-ceramic systems following metalceramics restorations allowed simulation of natural dentition due to favorable esthetics and resistance. In-Ceram is an alternative when esthetics is primordial as well as resistance required in rehabilitation. However, an ideal smile is associated to not only shape, color, texture and translucency but also harmony with gingival tissue. So, the aim of this study is to report a clinical case based on periodontal and fixed partial dentures principles to perform periodontal plastic surgery followed by esthetic rehabilitation. A female patient, 40-year-old, presented complaint about dental esthetics. After clinical and radiographic exams, metal-ceramics crowns (teeth 11, 12, 13, 21, 22 and 23) were considered unsatisfactory due to marginal leakage, color change in gingival tissue associated to metallic margin, and gummy smile. So, a crown lengthening surgery of anterior teeth was performed followed by rehabilitation of superior teeth with In-Ceram single crowns. Clinical significance: The interaction between periodontics and fixed prosthodontic area is the key of an adequated treatment planning which involves gingival smile to provide function and an esthetic condition in association with an esthetic, resistant and predictable material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This study constitutes a clinical and genetic study of all newborn and stillborn infants with birth defects seen in a period of one year in a medical school hospital located in Brazil. The aims of this study were to estimate the incidence, causes and consequences of the defects. Methods. For all infants we carried out physical assessment, photographic records, analysis of medical records and collection of additional information with the family, besides the karyotypic analysis or molecular tests in indicated cases. Result: The incidence of birth defects was 2.8%. Among them, the etiology was identified in 73.6% (ci95%: 64.4-81.6%). Etiology involving the participation of genetic factors single or associated with environmental factors) was more frequent 94.5%, ci95%: 88.5-98.0%) than those caused exclusively by environmental factors (alcohol in and gestational diabetes mellitus). The conclusive or presumed diagnosis was possible in 85% of the cases. Among them, the isolated congenital heart disease (9.5%) and Down syndrome (9.5%) were the most common, followed by gastroschisis (8.4%), neural tube defects (7.4%) and clubfoot (5.3%). Maternal age, parental consanguinity, exposure to teratogenic agents and family susceptibility were some of the identified risk factors. The most common observed consequences were prolonged hospital stays and death. Conclusions: The current incidence of birth defects among newborns and stillbirths of in our population is similar to those obtained by other studies performed in Brazil and in other underdeveloped countries. Birth defects are one of the major causes leading to lost years of potential life. The study of birth defects in underdeveloped countries should continue. The identification of incidence, risk factors and consequences are essential for planning preventive measures and effective treatments. © 2011 Fett-Conte et al; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hyoid bone contributes to the maintenance of the airway, chewing and swallowing, given to its anatomical and functional relations to the craniocervical complex. Cephalometric analysis has great importance for orthopedics, orthodontics and oral maxillary surgery. For the treatment of patients with special care needs, the cephalometric evaluation of the position of the hyoid bone should also contribute as a complementary element for dental diagnosis and the selection of the adequate treatment. The aim of this paper is to demonstrate the alteration of the hyoid position after carrying out the functional orthopedic maxillary treatment in a 9 year-old patient with Down Syndrome. Initial cephalometric analysis revealed inadequate position of hyoid bone. The association of speech therapy to dynamic functional rehabilitation of jaws showed a positive effect in occlusal relation and facial expression. After treatment, all dimensions obtained from the hyoid triangle were higher than initial ones, except the anterior-posterior value of C3-H, which suggested function improvement of stomatognathic system. Once considered its anatomical and physiological relationship with the others structures of the stomatognathic system, cephalometric analysis of hyoid bone position was helpful to the comprehension of the craniofacial abnormalities related to chromosomal anomaly, and thus is essential to the interdisciplinary dialogue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study the local properties of a class of codimension-2 defects of the 6d N = (2, 0) theories of type J = A, D, E labeled by nilpotent orbits of a Lie algebra $g, where g is determined by J and the outer-automorphism twist around the defect. This class is a natural generalization of the defects of the six-dimensional (6d) theory of type SU(N) labeled by a Young diagram with N boxes. For any of these defects, we determine its contribution to the dimension of the Higgs branch, to the Coulomb branch operators and their scaling dimensions, to the four-dimensional (4d) central charges a and c and to the flavor central charge k. © 2013 World Scientific Publishing Company.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By solving the time dependent Ginzburg-Landau equations, we investigated the influence of an internal triangular arrangement of point-like defects on the vortex configurations in a thin mesoscopic sample. The effect of the number of internal defects and their nature on the entrance position of the vortex is studied for a very thin circular sample. We found that the interplay between the vortex-vortex repulsion, the vortex-defect interaction and the interaction with the sample border leads to non-commensurate vortex configurations. © 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tissue engineering has special interest in bone tissue aiming at future medical applications Studies have focused on recombinant human bone morphogenetic protein-2 (rhBMP-2) and natural latex proteins due to the osteogenic properties of rhBMP-2 and the angiogenic characteristic of fraction 1 protein (P-1) extracted from the rubber tree Hevea brasiliensis. Furthermore, heterologous fibrin sealant (FS) has been shown as a promising alternative in regenerative therapies. The aim of this study was to evaluate these substances for the repair of bone defects in rats. A bone defect measuring 3 mm in diameter was created in the proximal metaphysis of the left tibia of 60 rats and was implanted with rhBMP-2 or P-1 in combination with a new heterologous FS derived from snake venom. The animals were divided into six groups: control (unfilled bone defect), rhBMP-2 (defect filled with 5 mu g rhBMP-2), P-1 (defect filled with 5 mu g P-1), FS (defect filled with 8 mu g FS), FS/rhBMP-2 (defect filled with 8 mu g FS and 5 mu g rhBMP-2), FS/P-1 (defect filled with 8 mu g FS and 5 mu g P-1). The animals were sacrificed 2 and 6 weeks after surgery. The newly formed bone projected from the margins of the original bone and exhibited trabecular morphology and a disorganized arrangement of osteocyte lacunae. Immunohistochemical analysis showed intense expression of osteocalcin in all groups. Histometric analysis revealed a significant difference in all groups after 2 weeks (p < 0.05), except for the rhBMP-2 and FS/rhBMP-2 groups (p > 0.05). A statistically significant difference (p < 0.05) was observed in all groups after 6 weeks in relation to the volume of newly formed bone in the surgical area. In conclusion, the new heterologous fibrin sealant was found to be biocompatible and the combination with rhBMP-2 showed the highest osteogenic and osteoconductive capacity for bone healing. These findings suggest a promising application of this combination in the regeneration surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The conventional methods of maxillary alveolar reconstruction in patient with cleft are the periosteoplasty and autologous bone grafting. As an important alternative of bone substitution, there is the recombinant human bone morphogenetic protein-2 (rhBMP-2). This study compares the rhBMP-2 with periosteoplasty and autologous bone grafting. Methods: Patients with cleft and alveolar defect were divided into 3 groups of 6 patients who underwent to autologous iliac crest bone grafting, resorbable collagen sponge with rhBMP2, and periosteoplasty, respectively. The analysis was performed through computed tomographic scan preoperatively and at months 3, 6, and 12 postoperatively. The variables analyzed were the alveolar defect volume, formed bone volume, bone formation rate, maxillary height repair rate, and the formed bone density mean. Results: The formed bone volume was similar comparing the bone graft and BMP groups at 1-year postoperative analysis (P = 0.58). Both of them had the formed bone volume significantly larger than the periosteoplasty group at 3 and 6 months postoperatively. In this last group, the 1-year follow-up was canceled because the bone formation was insufficient. The bone formation rate, the maxillary height repair rate, and the mean of density of the formed bone were similar in the bone graft and BMP groups at 1-year follow-up with P values of 0.93, 0.90, and 0.81, respectively. Conclusions: The amount of formed bone in the periosteoplasty group was insufficient. There was no difference among the bone graft and rhBMP-2 therapy considering the parameters analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to compare the effects of canine guidance (CG) and bilateral balanced occlusion (BBO) on denture satisfaction and kinesiographic parameters of complete denture wearers, by means of a cross-over trial. Fifty edentulous patients received new maxillary and mandibular complete dentures. After the intra-oral adjustments and adaptation period, 44 participants were enrolled in the trial and randomly received a sequence of occlusal schemes: BBO followed by CG, or CG followed by BBO. Outcomes were assessed after 30 days of each occlusal scheme. Participants answered a denture satisfaction questionnaire and a kinesiograph instrument recorded mandibular physiologic movements and pattern of maxillary denture movement during chewing. Wilcoxon test and paired sample t-test were used to compare satisfaction levels and kinesiographic data for each occlusal scheme, respectively (a = 0.05). The results showed no differences between occlusal schemes on participants satisfaction and in any of the kinesiographic parameters studied, except for the vertical intrusion of the maxillary complete denture during chewing, which was lower with CG. It can be concluded that the occlusal scheme did not influence on satisfaction and kinesiographic parameters evaluated, as long as volume and resilience of residual edentulous ridges of the participants were normal. Clinical Trial Registration Identifier: NC.T01420536.