859 resultados para Power quality improvement


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The overall aim of the study was to explore primary school teachers’ experiences of constraints to their work, and actions taken for improvement after undergoing in-service courses in the Education Quality Improvement through Pedagogy program. The research interest was thus to deepen the understanding of teachers’ experiences of constraints to their work and experiences of actions taken to improve classroom actions. In order to achieve this ambition, the study was conducted with primary school teachers in Shinyanga district-Tanzania. Two research questions guided the study: What do teachers experience as constraints to their work? The second: How have teachers improved their classroom actions after undergoing professional development courses? The theoretical framework of the study is centred on limiting and enabling frames on teachers’ work and professional development. In order to understand the classroom situations, qualitative research was designed applying a phenomenological approach with semi-structured interview, observation and videotaping to collect data. Forty experienced primary school teachers from ten primary schools participated in the study. The results of the first research question indicate that teachers face many constraints in their work. Three categories identified as interactional, environmental and professional role constraints. The most critical experienced by all teachers is teaching in large classes and inadequate teaching and learning materials. The results of the second research question show that teachers’ actions taken for improving their work were influenced by professional development activities. Three main categories including expanded interaction, expanded use of environment and expanded professional roles were identified. Generally, the knowledge generated is relevant for viewing teachers’ experiences of the challenges they encounter in teaching and the importance of professional development beyond the sampled respondents. The results suggest that constant provision of teachers’ professional development could improve teaching performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tutkimuksen tavoitteena oli luoda kohdeyritykseen toimintamalli, jonka avulla saadaan osallistettua työntekijät, tiiminvetäjät ja työnjohto tuotannon jatkuvaan parantamiseen sekä parannettua tuotannon takaisinkytkentää tiimitasolla. Tutkimus rajattiin pilottitiimiin sekä tiimissä olevien työpisteiden kautta reititettyihin tuotteisiin. Ennen tutkimuksen aloitusta yrityksellä oli jo olemassa sähköinen aloitejärjestelmä, mutta sen käyttö oli organisaation uudelleen järjestelyjen myötä vähentynyt. Tutkimuksen teoriaosassa tutustuttiin jatkuvan parantamisen kulttuuriin ja työkaluihin. Lisäksi tutustuttiin laadunhallinnan sisältöön, käsitteistöön ja laadunvalvontatyökaluihin sekä tuotannon mittareihin. Teorian pohjalta tutkimuksessa luotiin jatkuvan parantamisen toimintamalli, joka tunnistaa ja eliminoi prosessissa olevaa hukkaa osallistamalla pilottitiimin työntekijöitä hukkakorttien avulla. Lisäksi tutkimuksessa luotiin toimintamalli tuotannon kehitysideoiden raportointiin ja käsittelyyn. Tuotannon takaisinkytkentää kehitettiin luomalla pilottitiimiin tuloskortti sekä perustamalla yritykseen päiväkatsauskäytäntö. Tutkimuksessa suoritettiin myös toimihenkilötason kehitysprojekteja käyttäen apuna teoriassa esiteltyjä malleja ja työkaluja. Tuloksena saatiin toimintamalli, joka tuottaa työntekijämäärään suhteutettuna enemmän kehitysideoita sekä käsittelee ne tehokkaammin kuin sähköinen aloitejärjestelmä. Hukkakorteilla toteutetun hukan raportoinnin kautta tunnistettiin ja raportoitiin seitsemän viikon tarkasteluajanjakson aikana yhteensä 23,6 tuntia hukka-aikaa. Tiimin tuloskortin avulla tiimin työntekijät pystyivät viikkotasolla seuraamaan oman tiiminsä suorituskykyä tavoitearvoihin verrattuna. Tämä näkyi muun muassa tiimin suoritustason nousuna. Kehitysprojektien avulla saatiin parannettua pilottitiimin toiminnan ja tuotteiden laatua. Päiväkatsauskäytännön avulla saatiin osallistettua tiiminvetäjät ongelmaratkaisuun sekä tuotannon suorituskyvyn varmistamiseen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Medium-voltage motor drives extend the power rating of AC motor drives in industrial applications. Multilevel converters are gaining an ever-stronger foothold in this field. This doctoral dissertation introduces a new topology to the family of modular multilevel converters: the modular double-cascade converter. The modularity of the converter is enabled by the application of multiwinding mediumfrequency isolation transformers. Owing to the innovative transformer link, the converter presents many advantageous properties at a concept level: modularity, high input and output power quality, small footprint, and wide variety of applications, among others. Further, the research demonstrates that the transformer link also plays a key role in the disadvantages of the topology. An extensive simulation study on the new converter is performed. The focus of the simulation study is on the development of control algorithms and the feasibility of the topology. In particular, the circuit and control concepts used in the grid interface, the coupling configurations of the load inverter, and the transformer link operation are thoroughly investigated. Experimental results provide proof-of-concept results on the operation principle of the converter. This work concludes a research collaboration project on multilevel converters between LUT and Vacon Plc. The project was active from 2009 until 2014.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ventilator-associated pneumonia (VAP) remains one of the major causes of infection in the intensive care unit (ICU) and is associated with the length of hospital stay, duration of mechanical ventilation, and use of broad-spectrum antibiotics. We compared the frequency of VAP 10 months prior to (pre-intervention group) and 13 months after (post-intervention group) initiation of the use of a heat and moisture exchanger (HME) filter. This is a study with prospective before-and-after design performed in the ICU in a tertiary university hospital. Three hundred and fourteen patients were admitted to the ICU under mechanical ventilation, 168 of whom were included in group HH (heated humidifier) and 146 in group HME. The frequency of VAP per 1000 ventilator-days was similar for both the HH and HME groups (18.7 vs 17.4, respectively; P = 0.97). Duration of mechanical ventilation (11 vs 12 days, respectively; P = 0.48) and length of ICU stay (11 vs 12 days, respectively; P = 0.39) did not differ between the HH and HME groups. The chance of developing VAP was higher in patients with a longer ICU stay and longer duration of mechanical ventilation. This finding was similar when adjusted for the use of HME. The use of HME in intensive care did not reduce the incidence of VAP, the duration of mechanical ventilation, or the length of stay in the ICU in the study population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effects of body condition recovery (BC), carcass electrical stimulation (ES), aging time (AT 7 - 14 days), and calcium chloride injection on the meat characteristics of Santa Inês ewes (±5 years old) slaughtered immediately after weaning or after the body condition recovery period were studied. The carcass temperature, pH, shear force (SF), cooking loss (CL), meat color (L*, a*, b*), and meat tenderness were evaluated. A completely randomized design in a 2 × 2 × 2 × 3 (BC × ES × CaCl2 × AT) factorial arrangement was used, and the sensory tenderness data were analyzed using the table of Minimum Number of Correct Answers for the Duo-Trio test. The body condition recovery reduces the shear force in 8%, increasing their tenderness. Electrical stimulation reduced the shear force (24%) and did not change the other parameters. The aging time (7 or 14 days) decreased the shear force (18-26%), effect that was enhanced by electrical stimulation, and it darkened the meat reducing lightness (L*) and increasing yellowness (b*). The treatment with CaCl2 was the most effective in tenderizing meat by reducing the shear force ( 35%); increasing the cooking loss (4.5%); and increasing L* and b* lightening the meat. The sensory evaluation of tenderness corroborates the findings of the experimental evaluation regarding the effect of the treatment with CaCl2 on the meat quality improvement. It was concluded that the treatments improve meat characteristics achieving better results when applied together.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent developments in power electronics technology have made it possible to develop competitive and reliable low-voltage DC (LVDC) distribution networks. Further, islanded microgrids—isolated small-scale localized distribution networks— have been proposed to reliably supply power using distributed generations. However, islanded operations face many issues such as power quality, voltage regulation, network stability, and protection. In this thesis, an energy management system (EMS) that ensures efficient energy and power balancing and voltage regulation has been proposed for an LVDC island network utilizing solar panels for electricity production and lead-acid batteries for energy storage. The EMS uses the master/slave method with robust communication infrastructure to control the production, storage, and loads. The logical basis for the EMS operations has been established by proposing functionalities of the network components as well as by defining appropriate operation modes that encompass all situations. During loss-of-powersupply periods, load prioritizations and disconnections are employed to maintain the power supply to at least some loads. The proposed EMS ensures optimal energy balance in the network. A sizing method based on discrete-event simulations has also been proposed to obtain reliable capacities of the photovoltaic array and battery. In addition, an algorithm to determine the number of hours of electric power supply that can be guaranteed to the customers at any given location has been developed. The successful performances of all the proposed algorithms have been demonstrated by simulations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this bachelor’s thesis are examined the benefits of current distortion detection device application in customer premises low voltage networks. The purpose of this study was to find out if there are benefits for measuring current distortion in low-voltage residential networks. Concluding into who can benefit from measuring the power quality. The research focuses on benefits based on the standardization in Europe and United States of America. In this research, were also given examples of appliances in which current distortion detection device could be used. Along with possible illustration of user interface for the device. The research was conducted as an analysis of the benefits of current distortion detection device in residential low voltage networks. The research was based on literature review. The study was divided to three sections. The first explain the reasons for benefitting from usage of the device and the second portrays the low-cost device, which could detect one-phase current distortion, in theory. The last section discuss of the benefits of usage of current distortion detection device while focusing on the beneficiaries. Based on the result of this research, there are benefits from usage to the current distortion detection device. The main benefitting party of the current distortion detection device was found to be manufactures, as they are held responsible of limiting the current distortion on behalf of consumers. Manufactures could adjust equipment to respond better to the distortion by having access to on-going current distortion in network. The other benefitting party are system operators, who would better locate distortion issues in low-voltage residential network to start prevention of long-term problems caused by current distortion early on.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transmission system operators and distribution system operators are experiencing new challenges in terms of reliability, power quality, and cost efficiency. Although the potential of energy storages to face those challenges is recognized, the economic implications are still obscure, which introduce the risk into the business models. This thesis aims to investigate the technical and economic value indicators of lithium-ion battery energy storage systems (BESS) in grid-scale applications. In order to do that, a comprehensive performance lithium-ion BESS model with degradation effects estimation is developed. The model development process implies literature review on lifetime modelling, use, and modification of previous study progress, building the additional system parts and integrating it into a complete tool. The constructed model is capable of describing the dynamic behavior of the BESS voltage, state of charge, temperature and capacity loss. Five control strategies for BESS unit providing primary frequency regulation are implemented, in addition to the model. The questions related to BESS dimensioning and the end of life (EoL) criterion are addressed. Simulations are performed with one-month real frequency data acquired from Fingrid. The lifetime and cost-benefit analysis of the simulation results allow to compare and determine the preferable control strategy. Finally, the study performs the sensitivity analysis of economic profitability with variable size, EoL and system price. The research reports that BESS can be profitable in certain cases and presents the recommendations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cette thèse a pour but de documenter la réorganisation des services effectuée au programme Enfants et adolescents (PEA) du Centre de réadaptation Estrie, Sherbrooke. Une démarche de recherche-action participative (RAP) est utilisée afin de collaborer au développement, à l’implantation et à l’évaluation d’un nouveau modèle de services visant à accroître l’accessibilité et la qualité des services de réadaptation offerts aux enfants ayant une déficience physique. Spécifiquement, les objectifs sont : 1) de documenter les retombées de la réorganisation des services; 2) de réaliser une analyse critique du processus de changement. Des méthodes quantitatives et qualitatives sont utilisées afin d’atteindre ces objectifs. Tout d’abord, la Mesure des processus de soins (MPOC) documente la perception de la qualité avant (2007), pendant (2008) et après (2009) l’implantation du nouveau modèle de services. Au total, cet outil est employé auprès de 222 familles et 129 intervenants. À quatre reprises, les intervenants et les gestionnaires répondent également à un questionnaire sur leurs perceptions des forces, des faiblesses, des opportunités et des menaces au PEA. En 2008 et en 2009, des focus groups et des entrevues téléphoniques sont réalisées auprès des familles (n=5), des intervenants (n=19) et des gestionnaires (n=13) afin de documenter leurs perceptions sur le processus de changement et sur les retombées de la réorganisation des services. Quant à l’observation participante, elle permet de recueillir de l’information sur le processus de réorganisation des services tout au long de ces trois années. Enfin, les informations recueillies sont analysées à l’aide de différentes approches, dont des tests statistiques et des analyses de contenu utilisant une grille de codification inspirée de la théorie des systèmes d’actions organisées. Les résultats indiquent que davantage d’enfants reçoivent des services en 2009 en comparaison à 2007. De plus, la qualité des services s’est maintenue selon les perceptions évaluées par la MPOC (article 1). L’utilisation d’interventions de groupe contribue fort probablement à augmenter le nombre d’enfants qui reçoivent des services, mais plusieurs défis doivent être adressés afin que cette modalité d’intervention soit réellement efficiente (article 2). Les résultats font ressortir que le processus de réorganisation des services est complexe. L’évaluation des forces, des faiblesses, des opportunités et des menaces d’un programme, de même que l’implication des acteurs dans le processus de développement d’un nouveau modèle de services, favorisent l’amélioration continue de la qualité (article 3). Or, les facilitateurs et les obstacles à l’implantation du nouveau modèle de services évoluent durant la réorganisation des services. Considérant cela, il est important de poser les actions nécessaires afin de soutenir le changement tout au long du processus (article 4). En résumé, cette thèse contribue à l’avancement des connaissances en réadaptation en comblant une lacune dans les écrits scientifiques. En effet, peu de projets visant le développement et l’implantation de nouveaux modèles de services sont évalués et documentés. Pourtant, des modèles tels que celui développé par le PEA semblent prometteurs afin d’améliorer l’accessibilité, et éventuellement, la qualité des services de réadaptation chez l’enfant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cette thèse s’intéresse à l’amélioration des soins et des services de santé et touche aux relations entre 3 grands thèmes de l’analyse des organisations de santé : la gouvernance, le changement et les pratiques professionnelles. En nous appuyant sur l’analyse organisationnelle contemporaine, nous visons à mieux comprendre l’interface entre l’organisation et les pratiques cliniques. D’une part, nous souhaitons mieux comprendre comment l’organisation structure et potentialise les pratiques des acteurs. D’autre part, dans une perspective d’acteurs stratégiques, nous souhaitons mieux comprendre le rôle des pratiques des professionnels dans l’actualisation de leur profession et dans la transformation et l’évolution des organisations. Notre étude se fonde sur l’hypothèse qu’une synergie accrue entre l’organisation et les pratiques des professionnels favorisent l’amélioration de la qualité des soins et des services de santé. En 2004, le gouvernement ontarien entreprend une importante réforme des soins et services dans le domaine du cancer et revoit les rôles et mandats du Cancer Care Ontario, l’organisation responsable du développement des orientations stratégiques et du financement des services en cancer dans la province. Cette réforme appelle de nombreux changements organisationnels et cliniques et vise à améliorer la qualité des soins et des services dans le domaine de l’oncologie. C’est dans le cadre de cette réforme que nous avons analysé l’implantation d’un système de soins et de services pour améliorer la performance et la qualité et analysé le rôle des pratiques professionnelles, spécifiquement les pratiques infirmières, dans la transformation de ce système. La stratégie de recherche utilisée correspond à l’étude approfondie d’un cas correspondant à l’agence de soins et de services en oncologie en Ontario, le Cancer Care Ontario, et des pratiques professionnelles infirmières évoluant dans ce modèle. Le choix délibéré de ce cas repose sur les modalités organisationnelles spécifiques à l’Ontario en termes de soins en oncologie. La collecte de données repose sur 3 sources principales : les entrevues semi-structurées (n=25), l’analyse d’une abondante documentation et les observations non participatives. La thèse s’articule autour de trois articles. Le premier article vise à définir le concept de gouvernance clinique. Nous présentons l’origine du concept et définissons ses principales composantes. Concept aux frontières floues, la gouvernance clinique est axée sur le développement d’initiatives cliniques et organisationnelles visant à améliorer la qualité des soins de santé et la sécurité des patients. L’analyse de la littérature scientifique démontre la prédominance d’une vision statique de la gouvernance clinique et d’un contrôle accentué des pratiques professionnelles dans l’atteinte de l’efficience et de l’excellence dans les soins et les services. Notre article offre une conception plus dynamique de la gouvernance clinique qui tient compte de la synergie entre le contexte organisationnel et les pratiques des professionnels et soulève les enjeux reliés à son implantation. Le second article s’intéresse à l’ensemble des leviers mobilisés pour institutionnaliser les principes d’amélioration continue de la qualité dans les systèmes de santé. Nous avons analysé le rôle et la portée des leviers dans l’évolution du système de soins en oncologie en Ontario et dans la transformation des pratiques cliniques. Nos données empiriques révèlent 3 phases et de nombreuses étapes dans la transformation du système. Les acteurs en position d’autorité ont mobilisé un ensemble de leviers pour introduire des changements. Notre étude révèle que la transformation du Cancer Care Ontario est le reflet d’un changement radical de type évolutif où chacune des phases est une période charnière dans la transformation du système et l’implantation d’initiatives de qualité. Le troisième article pose un regard sur un levier spécifique de transformation, celui de la communauté de pratique, afin de mieux comprendre le rôle joué par les pratiques professionnelles dans la transformation de l’organisation des soins et ultimement dans le positionnement stratégique de la profession infirmière. Nous avons analysé les pratiques infirmières au sein de la communauté de pratique (CDP) des infirmières en pratique avancée en oncologie. En nous appuyant sur la théorie de la stratégie en tant que pratique sociale, nos résultats indiquent que l’investissement de la profession dans des domaines stratégiques augmente les capacités des infirmières à transformer leurs pratiques et à transformer l’organisation. Nos résultats soulignent le rôle déterminant du contexte dans le développement de capacités stratégiques chez les professionnels. Enfin, nos résultats révèlent 3 stratégies émergentes des pratiques des infirmières : une stratégie de développement de la pratique infirmière en oncologie, une stratégie d’institutionnalisation des politiques de la CDP dans le système en oncologie et une stratégie de positionnement de la profession infirmière. Les résultats de notre étude démontrent que l’amélioration de la qualité des soins et des services de santé est située. L’implantation de transformations dans l’ensemble d’un système, tel que celui du cancer en Ontario, est tributaire d’une part, des capacités d’action des acteurs en position d’autorité qui mobilisent un ensemble de leviers pour introduire des changements et d’autre part, de la capacité des acteurs à la base de l’organisation à s’approprier les leviers pour développer un projet professionnel, améliorer leurs pratiques professionnelles et transformer le système de soins.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Travail dirigé présenté à la Faculté des sciences infirmières en vue de l’obtention du grade de Maître ès sciences (M.Sc.) en sciences infirmières option administration en sciences infirmières

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nach einem einleitenden ersten Kapitel wird im zweiten Kapitel der Stand der Technik für Regelungs- und Monitoringsysteme mit vernetzten Systemen dargestellt. Daraus wird die Motivation zur Entwicklung neuer, kostengünstiger Systeme abgeleitet. Im dritten Kapitel folgt eine Darstellung der verschiedenen Arten marktverfügbarer Embedded Systems und dafür geeigneter Betriebs­systeme. Anforderungen an verteilte Regelungssysteme, unterschiedliche Strukturen dieser Systeme und deren Vor- und Nachteile sind Gegenstand des vierten Kapitels. Anhand von Beispielen aus den Bereichen Erzeugungsmanagement für den Betrieb von KWK-Anlagen, Energieverbrauchsmonitoring und Smart-Metering wird der Einsatz von verteilten Regelungs- und Monitoringsystemen im fünften Kapitel dargestellt. Im folgenden sechsten Kapitel wird die Bedeutung normierter Kommunikation für den Einsatz in verteilten Systemen sowie dafür vorhandene Standards aus der elektrischen Energieversorgungstechnik und der Automatisierungstechnik behandelt. Der Stand der Internet-Technik für verteilte Systeme ist Gegenstand des siebten Kapitels. Dabei werden zunächst die verschiedenen drahtlosen und drahtgebundenen Kommunikationsmedien vorgestellt und ihre Eigenschaften und die Rand­bedingungen für ihren Einsatz erörtert. Ebenso werden technische Probleme beim Einsatz der Internet-Technik aufgezeigt und Lösungsmöglichkeiten für diese Probleme dargestellt. Es folgt eine Übersicht von Netzwerkdiensten, die für den Betrieb von verteilten Systemen notwendig sind. Außerdem werden Techniken zur Überwachung von verteilten Systemen behandelt. Kapitel acht zeigt Sicherheitsrisiken bei der Nutzung des Internets auf und bewertet verschiedene Techniken zur Absicherung des Netzwerkverkehrs. Kapitel neun stellt ein Internet-basiertes Client-Server-System zur Online-Visualisierung von Anlagendaten im Webbrowser mit Hilfe von Java-Applets und XML-RPC vor. Die Visualisierung von Anlagendaten auf Mobiltelefonen mit Hilfe des Wireless Application Protocol sowie die dafür notwendige Software und Infrastruktur ist Gegenstand des zehnten Kapitels. Im elften Kapitel wird eine neuartige Software für die Simulation von dezentralen Energiesystemen und deren Regelungs­systemen auf Basis von virtuellen Maschinen, virtuellen Netzwerken und einer thermischen Simulationsumgebung vorgestellt sowie deren Anwendung für die Reglerentwicklung erklärt. Verschiedene Techniken für die Installation von Betriebssystemen und Software für die Embedded Systems eines verteilten Systems werden im Kapitel zwölf untersucht. Im Kapitel 13 werden verschiedene Technologien zur Konfiguration und Parametrierung von Regelungssystemen in der industriellen Prozess- und Fertigungs­automatisierung hinsichtlich ihrer Eignung für dezentrale Energiesysteme analysiert. Anschließend wird eine Software zur Installation und Parametrierung von Monitoringsystemen sowie der dazugehörigen Infrastruktur vorgestellt. Kapitel 14 beschäftigt sich mit Anforderungen an die Hardware für verteilte Systeme und mit Maßnahmen zur Erhöhung der Betriebs- und der Datensicherheit. Im 15. Kapitel werden die in den bisherigen Kapiteln vorgestellten Techniken anhand eines großen verteilten Monitoringsystems und anhand eines Power Flow and Power Quality Management Systems auf Basis von verteilten Embedded Systems evaluiert. Kapitel 16 fasst die Ergebnisse der Arbeit zusammen und enthält einen Ausblick auf zukünftige Entwicklungen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La Garnatxa negra és la varietat negra autòctona i majoritària a la Denominació d’Origen Empordà. La facilitat actual per obtenir rendiments elevats (selecció clonal, terrenys fèrtils, pràctiques agrícoles, ...) obliga a regular-ne la producció per obtenir collites de qualitat. L’eliminació d’una part de la collita mitjançant l’aclarida manual ha estat una pràctica efectiva i àmpliament utilitzada per la millora de la qualitat en situacions puntuals de sobreproducció. Però els seus elevats costos de mà d’obra la fan privativa per a la majoria de productors. L’aclarida química amb Etefon es perfila com una bona alternativa a l’hora de regular la producció amb uns costos d’execució acceptables. L’objectiu del treball era provar l’eficàcia de l’Etefon com a aclaridor químic en vinya per a la varietat Garnatxa negra com a alternativa a l’aclarida manual tradicional

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible