984 resultados para Point-Contact


Relevância:

20.00% 20.00%

Publicador:

Resumo:

For uniformly asymptotically affine (uaa) Markov maps on train tracks, we prove the following type of rigidity result: if a topological conjugacy between them is (uaa) at a point in the train track then the conjugacy is (uaa) everywhere. In particular, our methods apply to the case in which the domains of the Markov maps are Canter sets. We also present similar statements for (uaa:) and C-r Markov families. These results generalize the similar ones of Sullivan and de Faria for C-r expanding circle maps with r > 1 and have useful applications to hyperbolic dynamics on surfaces and laminations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For diffeomorphisms on surfaces with basic sets, we show the following type of rigidity result: if a topological conjugacy between them is differentiable at a point in the basic set then the conjugacy has a smooth extension to the surface. These results generalize the similar ones of D. Sullivan, E. de Faria and ours for one-dimensional expanding dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1st ASPIC International Congress

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01 × 10− 7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reports on airborne dermatoses are mainly published in the context of occupational settings. Hence, in recent years, dermatologists and also occupational physicians have become increasingly aware of the airborne source of contact dermatitis, resulting mainly from exposure to irritants or allergens. However, their occurrence is still underestimated, because reports often omit the term 'airborne' in relation to dust or volatile allergens. For the present update, we screened the journals 'Contact Dermatitis' (July 2000 to December 2006); 'Dermatitis', formerly named 'American Journal of Contact Dermatitis'; 'La Lettre du Gerda' (January 2000 to December 2006); and also included relevant articles from other journals published during the same period. This resulted in an updated list of airborne dermatitis causes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 909 Biomphalaria tenagophila were collected from two areas in Guarulhos (Metropolitan area of São Paulo, São Paulo State, Brazil) to assess larval trematode infections. In all collection sites, only this species was found and 183 (20.13%) harbored trematode infections. In these collections, four morphologically distinguishable types of cercariae were identified by confocal microscopy. Xiphidiocercaria (Cercaria lutzi) was the most common type of cercaria recovered, contributing 76.5% of all infections. Schistosoma mansoni cercariae were recovered and comprised the total of 13.11%. Strigea cercaria (Cercaria caratinguensis) and Brevifurcate pharyngeate Clinostomatoide cercaria (Cercaria ocellifera) contributed 8.33% and 2.22% of all infections, respectively. Double infections (S. mansoni and C. lutzi) were found in twelve snails, contributing 6.55% of all infections. In all sites studied, small vertebrates were found in snail habitats and it was observed human contact with the water. The presence of trematode infected snails in large cities has public health implications. It further provides a starting point for some comprehensive studies on snail-related aspects of transmission and biology of trematode of medical and veterinary importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rodents are the most frequently used animals in surgical experimentation. It is estimated that guinea pigs in particular are the third most commonly used species in this context. To disinfect guinea pigs’ skin, either alcohol or surgical iodine are most often used. In the context of an animal research project, a Nissen operation was performed in an adult male guinea pig. Because of accidental contamination of the operative field, a 10% povidone-iodine cutaneous solution was applied to the serosa of the anterior wall of the stomach and to the gastric fundus. The guinea pig died 12 hours after surgery due to an acute necrotizing hemorrhagic gastritis. Although there have been a few reports of povidone-iodine toxicity in the guinea pig, as far as the authors could determine, this is the first time that such a serious abdominal complication is reported. The authors believe that the possibility of a similar event should be taken into consideration when planning, executing and interpreting experiments in the guinea pig.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

introdução de drogas que assegurem o crescimento e a preservação das espécies, mas que eventualmente se espalham para o meio aquático envolvente, promovendo alterações da biodiversidade e entrar, directamente ou indirectamente, na cadeia alimentar. Quando estas drogas são agentes antimicrobianos de uso humano, tais como a amoxicilina, tetraciclina ou sulfonamidas, há um alto risco de aparecimento de espécies bacterianas resistentes, algo que constitui uma ameaça grave para a saúde pública. Esta introdução de agentes antimicrobianos no ambiente aquático através do sector das pescas pode ser reduzida através da monitorização regular ou contínua dos níveis de antibióticos no sistema de água, durante a execução, bem como antes da descarga para o meio aquático. Para isso, é necessário métodos analíticos que permitam uma frequência analítica elevada e continua, nos tanques de cultivos dos peixes. O presente trabalho descreve para este efeito, um sensor constituído por papel quimicamente modificado por reações em monocamadas, assumindo uma coloração típica após contacto com o antibiótico . A intensidade da coloração estava relacionada com a concentração desse antibiótico. A modificação do papel foi baseada na alteração química das unidades de glucose do papel por meio de uma reação covalente com reagentes apropriados. De seguida, criou-se uma camada de quitosano sobre o papel modificado onde se adsorveu a espécie metálica capaz de mudar de cor na presença de sulfadiazina. As modificações resultantes foram avaliadas em relação a vários parâmetros, com o intuito de provocar uma variação de cor intensa face à concentração de antibiótico. Os sensores preparados foram caracterizados do ponto de vista do seu desempenho analítico, efetuou-se a construção de uma gama de concentração que permitiu obter uma resposta previsível e transversal em relação a outros antibióticos, bem como a identificação de uma relação linear entre concentração e coordenadas de cor e a aplicação de sensores em amostra de água ambiental dopados com antibiótico. Generalizando, foi possível estabelecer um processo de modificação simples de papel capaz de medir a presença e quantidade de sulfadiazina