831 resultados para PTS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Delamination or crack propagation between plies is a critical issue for structural composites. In viewing this issue and the large application of woven fabrics in structural applications, especially the ones that requires high drapeability to be preformed in a RTM mold cavity such as the asymmetric ones, e.g HS series, this research aimed in dynamically testing the carbon fiber 5HS/RTM6 epoxy composites under opening mode using DCB set up in order to investigate the crack growth rate behavior in an irregular surface produced by the fabric waviness. The evaluation of the energy involved in each crack increment was based on the Irwin-Kies equation using compliance beam theory. The tests were conducted at constant stress ratio of R=0.1 with displacement control, frequency of 10 Hz, in accordance to ASTM E647-00 for measurement of crack growth rate. The results showed large scatter when compared to unidirectional carbon fiber composites due to damage accumulation at the fill tows.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Structural component failures due to cyclic loading are associated to surface damage of materials and its interaction with environment. Fatigue failure occurs with stresses below the yield strength of each material and is a result of crack initiation and propagation. In aeronautical components is an important parameter to be considered in project, as well as the corrosion and wear resistance. Thermally sprayed HVOF coatings have been considered to replace galvanic chromium deposits with comparable performance for wear and corrosion resistance. The aim of present research is to study the influence of WC-13Co-4Cr applied by HVOF, on the axial fatigue strength of 15-5 PH stainless steel. The shot peening treatment was used to restore fatigue performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project was originated from the national aircraft industry requirements to reduce the use of coated materials with electroplated chromium or cadmium that produce waste, which is harmful to health or the environment. The selected material is a Custom 465 stainless steel used in the aeronautical field due to its high mechanical strength. Considering the load sustained by the wheel axis of the landing gear, the Custom 465 is tested in axial fatigue. The objective is to compare the behavior of the Custom 465 with plated AISI 4340 steel coated with cadmium. X-ray diffraction method was used to determine the residual stress field induced by shot peening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the application of artificial neural networks in the analysis of the structural integrity of a building. The main objective is to apply an artificial neural network based on adaptive resonance theory, called ARTMAP-Fuzzy neural network and apply it to the identification and characterization of structural failure. This methodology can help professionals in the inspection of structures, to identify and characterize flaws in order to conduct preventative maintenance to ensure the integrity of the structure and decision-making. In order to validate the methodology was modeled a building of two walk, and from this model were simulated various situations (base-line condition and improper conditions), resulting in a database of signs, which were used as input data for ARTMAP-Fuzzy network. The results show efficiency, robustness and accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Project aims to study and verify the importance of effective communication in public organizations, considering current factors such as globalization and new trends in the behavior of the individuals. The issue is relevant because of the need to understand the relationships between the public institution and the various interest groups and research development of new practices of Public Relations as regards their influence on the municipal level. In this context, we present the concept of city, communication, citizenship and participation, focusing on the integration of these elements in the concept of Public Communication. Thus, attem pts to develop the applicability of instruments involving these concepts through scenario analysis, making communication purposal to the prefecture of Laranjal Paulista

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resistive-type of superconducting fault current limiters (RSFCL) have been developed for medium voltage class aiming to operate at 1 MVA power capacity and short time recovery (< 2 s). A RSFCL in form of superconducting modular device was designed and constructed using 50 m-length of YBCO coated conductor tapes for operation under 1 kV / 1 kA and acting time of 0.1 s. In order to increase the acting time the RSFCL was combined with an air-core reactor in parallel to increase the fault limiting time up to 1 s. The tests determined the electrical and thermal characteristics of the combined resistive/ inductive protection unit. The combined fault current limiter reached a limiting current of 583 A, corresponding to a limiting factor of 3.3 times within an acting time of up to 1 s.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we studied the synthesis of BSCCO-2212 superconducting phase associating a quite similar method developed by Pechini with the microwave-assisted hydrothermal method. To study the influence of the microwaves on the properties of BSCCO system, we synthesized two samples by such method. For one sample we used carbonates and for the other one we used nitrates as chemical reagents. We also produced a reference sample just using carbonates by Pechini's method to compare their morphological and superconducting properties. The structural properties of the samples were analyzed by scanning electron microscopy and X-ray diffraction. The Bi-2212 phase is predominant in all samples and despites the nitrates-like sample has a broader distribution of grain size in comparison with the reference sample, its magnetic behaviour is closer to that presented by the reference one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In general, the studies of finite size effects in mesoscopic superconductors have been carried out in such a way that the temperature parameter is constant in the entire system. However, we could have situations where a real sample is near a heater source, as an example. In such situations, gradients of temperature are present. On the other hand, mesoscopic superconductors are interesting systems due to the fact that they present confinement effects which influence all the vortex dynamics. Thus, in this work we studied the influence of thermal gradients on the vortex dynamics in mesoscopic superconductors. For this purposes, we used the time dependent Ginzburg-Landau equations. The thermal gradients produce an asymmetric distribution of the currents around the system which, in turn, yield interesting vortex configurations and difficult the formation of giant vortices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The long-term efficacy and safety of intravenous abatacept in patients (pts) with juvenile idiopathic arthritis (JIA) have been reported previously from the Phase III AWAKEN trial ([1, 2]). Here, we report efficacy, safety and pt-reported outcomes from the open-label, long-term extension (LTE) of AWAKEN, with up to 7 years of follow-up. Pts entered the LTE if they were JIA ACR 30 non-responders (NR) at the end of the 4-month lead-in period (abatacept only), or if they received abatacept or placebo (pbo) in the 6-month double-blind (DB) period. The Child Health Questionnaire was used to evaluate health-related quality of life (HRQoL); physical (PhS) and psychosocial (PsS) summary and pain scores were analyzed. Pain was assessed by parent global assessment using a 100 mm visual analog scale. Efficacy and HRQoL evaluations are reported up to Day 1765 (~ Year 5.5). Safety is presented for the cumulative period (lead-in, DB and LTE), for all pts who received abatacept during the LTE. Of the 153 pts entering the LTE (58 from DB abatacept group, 59 from DB pbo group, 36 NR), 69 completed the trial (29 abatacept, 27 pbo, 13 NR). For pts treated in the LTE, mean (range) exposure to abatacept was 53.6 (5.6–85.6) months. During the LTE, incidence rates of AEs and serious AEs per 100 pt-years were 209.1 and 5.6. Thirty pts (19.6%) had serious AEs; most were unrelated and were musculoskeletal (8.5%) or infectious events (6.5%). No malignancy was reported. There was one death (accidental; unrelated). At Day 169, JIA ACR 50 and 70 response rates were 79.3% and 55.2% in the abatacept group, and 52.5% and 30.5% in the pbo group; 31.0% and 10.2% of pts in the abatacept and pbo groups, respectively, had inactive disease. By Day 1765, JIA ACR 50 and 70 response rates were 93.9% and 78.8% in the abatacept group, and 80.0% and 63.3% in the pbo group; 51.5% and 33.3% had inactive disease. In the NR group, 69.2% and 53.8% of pts achieved JIA ACR 50 and 70 responses at Day 1765, and 30.8% had inactive disease. In pts who entered the LTE, mean baseline PhS scores were below the range for healthy children (abatacept 30.2, pbo 31.0, NR 29.5). At Day 169, 38.3% of pts had reached a PhS score >50 ((1). By the end of the LTE, 43.5% of pts had reached a PhS score >50. At baseline, mean PsS scores for those who entered the LTE were slightly lower than the mean for healthy children (abatacept 43.5, pbo 44.2, NR 47.0). At Day 169, 54.9% of pts had a PsS score >50 (1). By Day 1765, 58.1% of pts had reached a PsS score >50. At baseline, the mean pain score was 42.9. By Day 169, 13.9% of pts were considered pain free (pain score = 0); this was maintained over the LTE (1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of long duration exercise program on physical fitness components of functional capacity in individuals with Parkinson disease (PD) and to evaluate ongoing effects of exercise after 8 to 10-week follow-up without exercise. Twenty-four individuals with PD were randomly assigned to two groups: generalized exercise program and stretching exercise program (control group). The generalized exercise program provided training in physical fitness components of functional capacity. The stretching exercise program was characterized by low intensity and volume, mainly with static exercises. Both groups were evaluated before (BI) and after the 4-month (AI) exercise program. In addition, the individuals of generalized exercise program were also evaluated after 8-month exercise program and after 8 to 10- week follow-up without exercise. The generalized exercise program improved flexibility (BI - 38.50±12.42 cm; AI - 44.00±12.74 cm) and agility (BI - 30.59±7.54 s; AI - 28.56±8.20 s) while the stretching exercise program worsened coordination (BI - 23.27±6.58 s; AI - 28.06±7.37 s) and aerobic resistance (BI- 13.64±3.76 min; AI - 17.27±5.15 min) and improved balance (BI - 44.00±7.79 pts; AI - 46.57±6.53 pts). Lower-limb strength and UPDRS-motor scale scores were better at 8 months (14.75±2.92 rep and 26.25±13.97 pts, respectively) compared to baseline (13.13±2.59 rep and 31.63±12.82 pts, respectively) and 4 months (13.50±1.93 rep and 30.38±14.52 pts, respectively) for generalized exercise program. However, the benefits of 8 months of exercise were lost after 8 to 10-week follow-up without exercise (lower-limb strength - 12.43±3.15 rep and UPDRS-motor scale - 32.57±14.05 pts). In conclusion, generalized exercise program improved the functional capacity in individuals with PD, differently of stretching exercise program. In addition, a long duration exercise program promoted benefits for functional capacity and disease progression in individuals with PD. However, benefits were lost after a short period without exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Conventional cardiac rehabilitation program consist of 15 min of warm-up, 30 min of aerobic exercise and followed by 15 min calisthenics exercise. The Pilates method has been increasingly applied for its therapeutic benefits, however little scientific evidence supports or rebukes its use as a treatment in patients with heart failure (HF). Purpose: Investigate the effects of Pilates on exercise capacity variables in HF. Methods: Sixteen pts with HF, left ventricular ejection fraction 27 +/- 14%, NYHA class III were randomly assigned to conventional cardiac rehabilitation program (n = 8) or mat Pilates training (n = 8) for 16 weeks of 30 min of aerobic exercise followed by 20 min of the specific program. Results: At 16 weeks, pts in the mat Pilates group and conventional group showed significantly increase on exercise time 11.9 +/- 2.5 to 17.8 +/- 4 and 11.7 +/- 3.9 to 14.2 +/- 4 min, respectively. However, only the Pilates group increased significantly the ventilation (from 56 +/- 20 to 69 +/- 17 L/min, P= 0.02), peak VO2 (from 20.9 +/- 6 to 24.8 +/- 6 mL/kg/min, P= 0.01), and O-2 pulse (from 11.9 +/- 2 to 13.8 +/- 3 mL/bpm, P= 0.003). The Pilates group showed significantly increase in peak VO2 when compared with conventional group (24.8 +/- 6 vs. 18.3 +/- 4, P= 0.02). Conclusions: The result suggests that the Pilates method may be a beneficial adjunctive treatment that enhances functional capacity in patients with HF who are already receiving standard medical therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In the Global postural re-education (GPR) evaluation, posture alterations are associated with anterior or posterior muscular chain impairments. Our goal was to assess the reliability of the GPR muscular chain evaluation. Methods: Design: Inter-rater reliability study. Fifty physical therapists (PTs) and two experts trained in GPR assessed the standing posture from photographs of five youths with idiopathic scoliosis using a posture analysis grid with 23 posture indices (PI). The PTs and experts indicated the muscular chain associated with posture alterations. The PTs were also divided into three groups according to their experience in GPR. Experts' results (after consensus) were used to verify agreement between PTs and experts for muscular chain and posture assessments. We used Kappa coefficients (K) and the percentage of agreement (%A) to assess inter-rater reliability and intra-class coefficients (ICC) for determining agreement between PTs and experts. Results: For the muscular chain evaluation, reliability was moderate to substantial for 12 PI for the PTs (% A: 56 to 82; K: 0.42 to 0.76) and perfect for 19 PI for the experts. For posture assessment, reliability was moderate to substantial for 12 PI for the PTs (% A > 60%; K: 0.42 to 0.75) and moderate to perfect for 18 PI for the experts (% A: 80 to 100; K: 0.55 to 1.00). The agreement between PTs and experts was good for most muscular chain evaluations (18 PI; ICC: 0.82 to 0.99) and PI (19 PI; ICC: 0.78 to 1.00). Conclusions: The GPR muscular chain evaluation has good reliability for most posture indices. GPR evaluation should help guide physical therapists in targeting affected muscles for treatment of abnormal posture patterns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES] Las entradas de aerosoles procedentes del Continente Africano tienen un importante efecto en el clima y biogeoquímica marina de la Región Canaria. Por tal motivo, se estudiaron los factores que influyen en las concentraciones de partículas en el aire (PTS), la composición química de estas partículas y los flujos de deposición de los metales solubles (Al, Fe, Mn, Co, Ti y Cu). Para ello se tomaron muestras en tres estaciones de la Isla de Gran Canaria (Taliarte al nivel del mar, Tafira at 269 m altitud and Pico de la Gorra 1930 m altitud) desde el 2002. Utilizando las medidas de deposición seca y húmeda se puede estimar una deposición total anual para la Cuenca de Canarias de 1,36 millones de t año-1. Conociendo por tanto los valores de la composición química y la solubilidad de los elementos, podemos estimar los flujos de deposición de estos elementos solubles.