919 resultados para Organization of care
Resumo:
Two major difficulties arise when taking blood samples in children: the challenge of venous access and the comparatively large amount of blood required.
Resumo:
BACKGROUND: This project is part of an evaluation of complementary and alternative medicine (CAM) aimed at providing a scientific basis for the Swiss Government to include 5 CAM methods in basic health coverage: anthroposophic medicine, homeopathy, neural therapy, phytotherapy and Traditional Chinese Medicine (TCM). OBJECTIVES: The objective was to explore the philosophy of care (convictions and values, priorities in medical activity, motivation for CAM, criteria for the practice of CAM, limits of the used methods) of conventional and CAM general practitioners (GPs) and to determine differences between both groups. MATERIALS AND METHODS: This study was a cross-sectional survey of a representative sample of 623 GPs who provide complementary or conventional primary care. A mailed questionnaire with open-ended questions focusing on the philosophy of care was used for data collection. An appropriate methodology using a combination of quantitative and qualitative approaches was developed. RESULTS: Significant differences between both groups include philosophy of care (holistic versus positivistic approaches), motivation for CAM (intrinsic versus extrinsic) and priorities in medical activity. Both groups seem to be aware of limitations of the therapeutic methods used. The study reveals that conventional physicians are also using complementary medicine. DISCUSSION: Our study provides a wealth of data documenting several aspects of physicians' philosophy of care as well as differences and similarities between conventional and complementary care. Implications of the study with regard to quality of care as well as ethical and health policy issues should be investigated further.
Resumo:
Point-of-care testing (POCT) remains under scrutiny by healthcare professionals because of its ill-tried, young history. POCT methods are being developed by a few major equipment companies based on rapid progress in informatics and nanotechnology. Issues as POCT quality control, comparability with standard laboratory procedures, standardisation, traceability and round robin testing are being left to hospitals. As a result, the clinical and operational benefits of POCT were first evident for patients on the operating table. For the management of cardiovascular surgery patients, POCT technology is an indispensable aid. Improvement of the technology has meant that clinical laboratory pathologists now recognise the need for POCT beyond their high-throughput areas.
Multicentre evaluation of a new point-of-care test for the determination of NT-proBNP in whole blood
Resumo:
BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.
Resumo:
Excitatory neurons at the level of cortical layer 4 in the rodent somatosensory barrel field often display a strong eccentricity in comparison with layer 4 neurons in other cortical regions. In rat, dendritic symmetry of the 2 main excitatory neuronal classes, spiny stellate and star pyramid neurons (SSNs and SPNs), was quantified by an asymmetry index, the dendrite-free angle. We carefully measured shrinkage and analyzed its influence on morphological parameters. SSNs had mostly eccentric morphology, whereas SPNs were nearly radially symmetric. Most asymmetric neurons were located near the barrel border. The axonal projections, analyzed at the level of layer 4, were mostly restricted to a single barrel except for those of 3 interbarrel projection neurons. Comparing voxel representations of dendrites and axon collaterals of the same neuron revealed a close overlap of dendritic and axonal fields, more pronounced in SSNs versus SPNs and considerably stronger in spiny L4 neurons versus extragranular pyramidal cells. These observations suggest that within a barrel dendrites and axons of individual excitatory cells are organized in subcolumns that may confer receptive field properties such as directional selectivity to higher layers, whereas the interbarrel projections challenge our view of barrels as completely independent processors of thalamic input.
Resumo:
The performance of memory-guided saccades with two different delays (3 and 30 s of memorization) was studied in seven healthy subjects. Double-pulse transcranial magnetic stimulation (dTMS) with an interstimulus interval of 100 ms was applied over the right dorsolateral prefrontal cortex (DLPFC) early (1 s after target presentation) and late (28 s after target presentation). Early stimulation significantly increased in both delays the percentage of error in amplitude (PEA) of contralateral memory-guided saccades compared to the control experiment without stimulation. dTMS applied late in the delay had no significant effect on PEA. Furthermore, we found a significantly smaller effect of early stimulation in the long-delay paradigm. These results suggest a time-dependent hierarchical organization of the spatial working memory with a functional dominance of DLPFC during the early memorization, independent from the memorization delay. For a long memorization delay, however, working memory seems to have an additional, DLPFC-independent component.