988 resultados para Nonlinear dynamic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Room-temperature measurements of the magnetic susceptibility of Bovine Serum Albumin-based nanocapsules (50 to 300 nm in size) loaded with different amounts of maghemite nanoparticles (7.6 nm average diameter) have been carried out in this study The field (H) dependence of the imaginary peak susceptibility (f(P)) of the nanocomposite samples was investigated in the range of 0 to 4 kOe. From the analysis of the f(P) x H curves the concentration (N) dependence of the effective maghemite magnetocrystalline energy barrier (E) was obtained. Analysis of the E x N data was performed using a modified Morup-Tronc [Phys. Rev. Lett. 72, 3278 (1994)] model, from which a huge contribution from the magnetocrystalline surface anisotropy was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experiment examined the influence of memory for prior instances on aircraft conflict detection. Participants saw pairs of similar aircraft repeatedly conflict with each other. Performance improvements suggest that participants credited the conflict status of familiar aircraft pairs to repeated static features such as speed, and dynamic features such as aircraft relative position. Participants missed conflicts when a conflict pair resembled a pair that had repeatedly passed safely. Participants either did not attend to, or interpret, the bearing of aircraft correctly as a result of false memory-based expectations. Implications for instance models and situational awareness in dynamic systems are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum mechanics has been formulated in phase space, with the Wigner function as the representative of the quantum density operator, and classical mechanics has been formulated in Hilbert space, with the Groenewold operator as the representative of the classical Liouville density function. Semiclassical approximations to the quantum evolution of the Wigner function have been defined, enabling the quantum evolution to be approached from a classical starting point. Now analogous semiquantum approximations to the classical evolution of the Groenewold operator are defined, enabling the classical evolution to be approached from a quantum starting point. Simple nonlinear systems with one degree of freedom are considered, whose Hamiltonians are polynomials in the Hamiltonian of the simple harmonic oscillator. The behavior of expectation values of simple observables and of eigenvalues of the Groenewold operator are calculated numerically and compared for the various semiclassical and semiquantum approximations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piezoelectric polymers have been used to form the basis of dynamic strain gauges for the detection of stress waves. The linearity of response was tested using a split Hopkinson pressure bar arrangement. The results obtained illustrate the effectiveness of piezoelectric film strain gauges in the measurement of axial stress waves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this second paper, the three structural measures which have been developed are used in the modelling of a three stage centrifugal synthesis gas compressor. The goal of this case study is to determine the essential mathematical structure which must be incorporated into the compressor model to accurately model the shutdown of this system. A simple, accurate and functional model of the system is created via three structural measures. It was found that the model can be correctly reduced into its basic modes and that the order of the differential system can be reduced from 51(st) to 20(th). Of the 31 differential equational 21 reduce to algebraic relations, 8 become constants and 2 can be deleted thereby increasing the algebraic set from 70 to 91 equations. An interpretation is also obtained as to which physical phenomena are dominating the dynamics of the compressor add whether the compressor will enter surge during the shutdown. Comparisons of the reduced model performance against the full model are given, showing the accuracy and applicability of the approach. Copyright (C) 1996 Elsevier Science Ltd

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the purpose of developing a longitudinal model to predict hand-and-foot syndrome (HFS) dynamics in patients receiving capecitabine, data from two large phase III studies were used. Of 595 patients in the capecitabine arms, 400 patients were randomly selected to build the model, and the other 195 were assigned for model validation. A score for risk of developing HFS was modeled using the proportional odds model, a sigmoidal maximum effect model driven by capecitabine accumulation as estimated through a kinetic-pharmacodynamic model and a Markov process. The lower the calculated creatinine clearance value at inclusion, the higher was the risk of HFS. Model validation was performed by visual and statistical predictive checks. The predictive dynamic model of HFS in patients receiving capecitabine allows the prediction of toxicity risk based on cumulative capecitabine dose and previous HFS grade. This dose-toxicity model will be useful in developing Bayesian individual treatment adaptations and may be of use in the clinic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The identification of regulatory T cells (Treg cells) as CD4(+)CD25(high) cells may be upset by the increased frequency of activated effector T cells (Teff cells) in inflammatory diseases such as systemic lupus erythematosus (SLE). This study aimed to evaluate the frequency of T-cell subsets according to the expression of CD25 and CD127 in active (A-SLE) and inactive SLE (I-SLE). Methods: Peripheral blood mononuclear cells (PBMCs) from 26 A-SLE patients (SLE Disease Activity Index (SLEDAI) = 10.17 +/- 3.7), 31 I-SLE patients (SLEDAI = 0), and 26 healthy controls (HC) were analysed by multicolour flow. cytometry. Results: CD25(high) cell frequency was increased in A-SLE (5.2 +/- 5.7%) compared to I-SLE (3.4 +/- 3.4%) and HC (1.73 +/- 0.8%) (p < 0.01). However, the percentage of FoxP3(+) cells in the CD25(high) subset was decreased in A-SLE (24.6 +/- 16.4%) compared to I-SLE (33.7 +/- 16) and HC (45 +/- 25.1%) (p < 0.01). This was partly due to the increased frequency of Teff cells (CD25(high)CD127(+)FoxP3(empty set)) in A-SLE (10.7 +/- 7.3%) compared to I-SLE (8.5 +/- 6.5) and HC (6.1 +/- 1.8%) (p = 0.02). Hence the frequency of Treg cells (CD25(+/high)CD127(low/empty set)FoxP3(+)) was equivalent in A-SLE (1.4 +/- 0.8%), I-SLE (1.37 +/- 1.0%), and HC (1.13 +/- 0.59%) (p = 0.42). A-SLE presented an increased frequency of CD25(+)CD127(+)FoxP3(+) and CD25(empty set)FoxP3(+)CD127(low/empty set) T cells, which may represent intermediate phenotypes between Treg and Teff cells. Conclusions: The present study has provided data supporting normal Treg cell frequency in A-SLE and I-SLE as well as increased frequency of Teff cells in A-SLE. This scenario reflects a Treg/Teff ratio imbalance that may favour the inflammatory phenotype of the disease. In addition, the increased frequency of T cells with putative intermediate phenotypes may be compatible with a highly dynamic immune system in SLE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To obtain a high quality EMG acquisition, the signal must be recorded as far away as possible from muscle innervations and tendon zones, which are known to shift during dynamic contractions. This study describes a methodology, using commercial bipolar electrodes, to identify better electrode positions for superficial EMG of lower limb muscles during dynamic contractions. Eight female volunteers participated in this study. Myoelectric signals of the vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were acquired during maximum isometric contractions using bipolar electrodes. The electrode positions of each muscle were selected assessing SENIAM and then, other positions were located along the length of muscle up and down the SENIAM site. The raw signal (density), the linear envelopes, the RMS value, the motor point site, the position of the IZ and its shift during dynamic contractions were taken into account to select and compare electrode positions. For vastus lateralis and peroneus longus, the best sites were 66% and 25% of muscle length, respectively (similar to SENIAM location). The position of the tibialis anterior electrodes presented the best signal at 47.5% of its length (different from SENIAM location). The position of the gastrocnemius medialis electrodes was at 38% of its length and SENIAM does not specify a precise location for signal acquisition. The proposed method should be considered as another methodological step in every EMG study to guarantee the quality of the signal and subsequent human movement interpretations. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to compare different nonlinear functions for describing the growth curves of Nelore females. The growth curve parameters, their (co) variance components, and environmental and genetic effects were estimated jointly through a Bayesian hierarchical model. In the first stage of the hierarchy, 4 nonlinear functions were compared: Brody, Von Bertalanffy, Gompertz, and logistic. The analyses were carried out using 3 different data sets to check goodness of fit while having animals with few records. Three different assumptions about SD of fitting errors were considered: constancy throughout the trajectory, linear increasing until 3 yr of age and constancy thereafter, and variation following the nonlinear function applied in the first stage of the hierarchy. Comparisons of the overall goodness of fit were based on Akaike information criterion, the Bayesian information criterion, and the deviance information criterion. Goodness of fit at different points of the growth curve was compared applying the Gelfand`s check function. The posterior means of adult BW ranged from 531.78 to 586.89 kg. Greater estimates of adult BW were observed when the fitting error variance was considered constant along the trajectory. The models were not suitable to describe the SD of fitting errors at the beginning of the growth curve. All functions provided less accurate predictions at the beginning of growth, and predictions were more accurate after 48 mo of age. The prediction of adult BW using nonlinear functions can be accurate when growth curve parameters and their (co) variance components are estimated jointly. The hierarchical model used in the present study can be applied to the prediction of mature BW in herds in which a portion of the animals are culled before adult age. Gompertz, Von Bertalanffy, and Brody functions were adequate to establish mean growth patterns and to predict the adult BW of Nelore females. The Brody model was more accurate in predicting the birth weight of these animals and presented the best overall goodness of fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantitatively evaluate changes induced by the application of a femoral blood-pressure cuff (BPC) on run-off magnetic resonance angiography (MRA). which is a method generally previously proposed to reduce venous contamination in the leg. Materials and Methods: This study was Health Insurance Portability and Accountability Act (HIPAA)- and Institutional Review Board (IRB)-compliant, We used time-resolved gradient-echo gadolinium (Gd)-enhanced MRA to measure BPC effects on arterial, venous, and soft-tissue enhancement. Seven healthy volunteers (six men) were studied with the BPC applied at the mid-femoral level unilaterally using a 1.5T MR system after intravenous injection of Gd-BOPTA. Different statistical tools were used such as the Wilcoxon signed rank test and a cubic smoothing spline fit. Results: We found that BPC application induces delayed venous filling (as previously described), but also induces significant decreases in arterial inflow, arterial enhancement, vascular-soft tissue contrast, and delayed peak enhancement (which have not been previously measured). Conclusion: The potential benefits from using a BPC for run-off MRA must be balanced against the potential pitfalls, elucidated by our findings.