928 resultados para Non-perturbative methods


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Demand response has gained increasing importance in the context of competitive electricity markets and smart grid environments. In addition to the importance that has been given to the development of business models for integrating demand response, several methods have been developed to evaluate the consumers’ performance after the participation in a demand response event. The present paper uses those performance evaluation methods, namely customer baseline load calculation methods, to determine the expected consumption in each period of the consumer historic data. In the cases in which there is a certain difference between the actual consumption and the estimated consumption, the consumer is identified as a potential cause of non-technical losses. A case study demonstrates the application of the proposed method to real consumption data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the performance of the turbidimetric method of C-reactive protein (CRP) as a measure of low-grade inflammation in patients admitted with non-ST elevation acute coronary syndromes (ACS). METHODS: Serum samples obtained at hospital arrival from 68 patients (66±11 years, 40 men), admitted with unstable angina or non-ST elevation acute myocardial infarction were used to measure CRP by the methods of nephelometry and turbidimetry. RESULTS: The medians of C-reactive protein by the turbidimetric and nephelometric methods were 0.5 mg/dL and 0.47 mg/dL, respectively. A strong linear association existed between the 2 methods, according to the regression coefficient (b=0.75; 95% C.I.=0.70-0.80) and correlation coefficient (r=0.96; P<0.001). The mean difference between the nephelometric and turbidimetric CRP was 0.02 ± 0.91 mg/dL, and 100% agreement between the methods in the detection of high CRP was observed. CONCLUSION: In patients with non-ST elevation ACS, CRP values obtained by turbidimetry show a strong linear association with the method of nephelometry and perfect agreement in the detection of high CRP.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Anaplastic lymphoma kinase (ALK) rearrangements represents a new driver oncogenic event in non-small cell lung cancer (NSCLC). ALK positive patients account for a 1-7% of NSCLC patients. The objective of this study is to know the prevalence and clinical characteristics of ALK positive patients in a cohort of NSCLC patients and to compare inmunohistochemistry with D5F3 monoclonal antibody with gold standard method fluorescence in situ hybridation

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is an increasing interest to seek new enzyme preparations for the development of new products derived from bioprocesses to obtain alternative bio-based materials. In this context, four non-commercial lipases from Pseudomonas species were prepared, immobilized on different low-cost supports, and examined for potential biotechnological applications. Results: To reduce costs of eventual scaling-up, the new lipases were obtained directly from crude cell extracts or from growth culture supernatants, and immobilized by simple adsorption on Accurel EP100, Accurel MP1000 and Celite (R) 545. The enzymes evaluated were LipA and LipC from Pseudomonas sp. 42A2, a thermostable mutant of LipC, and LipI. 3 from Pseudomonas CR611, which were produced in either homologous or heterologous hosts. Best immobilization results were obtained on Accurel EP100 for LipA and on Accurel MP1000 for LipC and its thermostable variant. Lip I. 3, requiring a refolding step, was poorly immobilized on all supports tested ( best results for Accurel MP1000). To test the behavior of immobilized lipases, they were assayed in triolein transesterification, where the best results were observed for lipases immobilized on Accurel MP1000. Conclusions: The suggested protocol does not require protein purification and uses crude enzymes immobilized by a fast adsorption technique on low-cost supports, which makes the method suitable for an eventual scaling up aimed at biotechnological applications. Therefore, a fast, simple and economic method for lipase preparation and immobilization has been set up. The low price of the supports tested and the simplicity of the procedure, skipping the tedious and expensive purification steps, will contribute to cost reduction in biotechnological lipase-catalyzed processes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS) for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT), urease test and histologic examination for the diagnosis of H. pylori (HP) infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21) days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB) above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9) for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71) for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg), the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18) in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17). IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Virtual environments and real-time simulators (VERS) are becoming more and more important tools in research and development (R&D) process of non-road mobile machinery (NRMM). The virtual prototyping techniques enable faster and more cost-efficient development of machines compared to use of real life prototypes. High energy efficiency has become an important topic in the world of NRMM because of environmental and economic demands. The objective of this thesis is to develop VERS based methods for research and development of NRMM. A process using VERS for assessing effects of human operators on the life-cycle efficiency of NRMM was developed. Human in the loop simulations are ran using an underground mining loader to study the developed process. The simulations were ran in the virtual environment of the Laboratory of Intelligent Machines of Lappeenranta University of Technology. A physically adequate real-time simulation model of NRMM was shown to be reliable and cost effective in testing of hardware components by the means of hardware-in-the-loop (HIL) simulations. A control interface connecting integrated electro-hydraulic energy converter (IEHEC) with virtual simulation model of log crane was developed. IEHEC consists of a hydraulic pump-motor and an integrated electrical permanent magnet synchronous motorgenerator. The results show that state of the art real-time NRMM simulators are capable to solve factors related to energy consumption and productivity of the NRMM. A significant variation between the test drivers is found. The results show that VERS can be used for assessing human effects on the life-cycle efficiency of NRMM. HIL simulation responses compared to that achieved with conventional simulation method demonstrate the advances and drawbacks of various possible interfaces between the simulator and hardware part of the system under study. Novel ideas for arranging the interface are successfully tested and compared with the more traditional one. The proposed process for assessing the effects of operators on the life-cycle efficiency will be applied for wider group of operators in the future. Driving styles of the operators can be analysed statistically from sufficient large result data. The statistical analysis can find the most life-cycle efficient driving style for the specific environment and machinery. The proposed control interface for HIL simulation need to be further studied. The robustness and the adaptation of the interface in different situations must be verified. The future work will also include studying the suitability of the IEHEC for different working machines using the proposed HIL simulation method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the present thesis we have formulated the Dalgarno-Lewis procedure for two-and three-photon processes and an elegant alternate expressions are derived. Starting from a brief review on various multiphoton processes we have discussed the difficulties coming in the perturbative treatment of multiphoton processes. A small discussion on various available methods for studying multiphoton processes are presented in chapter 2. These theoretical treatments mainly concentrate on the evaluation of the higher order matrix elements coming in the perturbation theory. In chapter 3 we have described the use of Dalgarno-Lewis procedure and its implimentation on second order matrix elements. The analytical expressions for twophoton transition amplitude, two-photon ionization cross section, dipole dynamic polarizability and Kramers-Heiseberg are obtained in a unified manner. Fourth chapter is an extension of the implicit summation technique presented in chapter 3. We have clearly mentioned the advantage of our method, especially the analytical continuation of the relevant expressions suited for various values of radiation frequency which is also used for efficient numerical analysis. A possible extension of the work is to study various multiphoton processcs from the stark shifted first excited states of hydrogen atom. We can also extend this procedure for studying multiphoton processes in alkali atoms as well as Rydberg atoms. Also, instead of going for analytical expressions, one can try a complete numerical evaluation of the higher order matrix elements using this procedure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We consider a first order implicit time stepping procedure (Euler scheme) for the non-stationary Stokes equations in smoothly bounded domains of R3. Using energy estimates we can prove optimal convergence properties in the Sobolev spaces Hm(G) (m = 0;1;2) uniformly in time, provided that the solution of the Stokes equations has a certain degree of regularity. For the solution of the resulting Stokes resolvent boundary value problems we use a representation in form of hydrodynamical volume and boundary layer potentials, where the unknown source densities of the latter can be determined from uniquely solvable boundary integral equations’ systems. For the numerical computation of the potentials and the solution of the boundary integral equations a boundary element method of collocation type is used. Some simulations of a model problem are carried out and illustrate the efficiency of the method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper considers methods for testing for superiority or non-inferiority in active-control trials with binary data, when the relative treatment effect is expressed as an odds ratio. Three asymptotic tests for the log-odds ratio based on the unconditional binary likelihood are presented, namely the likelihood ratio, Wald and score tests. All three tests can be implemented straightforwardly in standard statistical software packages, as can the corresponding confidence intervals. Simulations indicate that the three alternatives are similar in terms of the Type I error, with values close to the nominal level. However, when the non-inferiority margin becomes large, the score test slightly exceeds the nominal level. In general, the highest power is obtained from the score test, although all three tests are similar and the observed differences in power are not of practical importance. Copyright (C) 2007 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Physical, cultural and biological methods for weed control have developed largely independently and are often concerned with weed control in different systems: physical and cultural control in annual crops and biocontrol in extensive grasslands. We discuss the strengths and limitations of four physical and cultural methods for weed control: mechanical, thermal, cutting, and intercropping, and the advantages and disadvantages of combining biological control with them. These physical and cultural control methods may increase soil nitrogen levels and alter microclimate at soil level; this may be of benefit to biocontrol agents, although physical disturbance to the soil and plant damage may be detrimental. Some weeds escape control by these methods; we suggest that these weeds may be controlled by biocontrol agents. It will be easiest to combine biological control with. re and cutting in grasslands; within arable systems it would be most promising to combine biological control (especially using seed predators and foliar pathogens) with cover-cropping, and mechanical weeding combined with foliar bacterial and possibly foliar fungal pathogens. We stress the need to consider the timing of application of combined control methods in order to cause least damage to the biocontrol agent, along with maximum damage to the weed and to consider the wider implications of these different weed control methods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The assessment of cellular effects by the aqueous phase of human feces (fecal water, FW) is a useful biomarker approach to study cancer risks and protective activities of food. In order to refine and develop the biomarker, different protocols of preparing FW were compared. Fecal waters were prepared by 3 methods: (A) direct centrifugation; (B) extraction of feces in PBS before centrifugation; and (C) centrifugation of lyophilized and reconstituted feces. Genotoxicity was determined in colon cells using the Comet assay. Selected samples were investigated for additional parameters related to carcinogenesis. Two of 7 FWs obtained by methods A and B were similarly genotoxic. Method B, however, yielded higher volumes of FW, allowing sterile filtration for long-term culture experiments. Four of 7 samples were non-genotoxic when prepared according to all 3 methods. FW from lyophilized feces and from fresh samples were equally genotoxic. FWs modulated cytotoxicity, paracellular permeability, and invasion, independent of their genotoxicity. All 3 methods of FW preparation can be used to assess genotoxicity. The higher volumes of FWobtained by preparation method B greatly enhance the perspectives of measuring different types of biological parameters and using these to disclose activities related to cancer development.