991 resultados para ND-YAG


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Desde la organogénesis y hasta estadios adultos, las células madre mesenquimales participan activamente dando origen y manteniéndola homeostasis del organismo. En la cavidad oral han sido aisladas desde variadas estructuras del órgano dental tales como el ligamento periodontal, pulpa dental, tejido gingival, folículo dental y papila apical significando una prometedora fuente de células madre mesenquimales las que pueden ser caracterizadas de acuerdo a los criterios mínimos establecidos por "The International Society for Cellular Therapy" que son: a) La adherencia al plástico; b) La expresión de marcadores CD73, CD90, CD105 y la carencia de CD34, CD45, CD14, CD11, CD79, CD19 y HLA-DR (clase II); c) Capacidad multipotencial de diferenciación hacia linaje osteogénico, condrogénico y adipogénico. El objetivo de esta revisión consiste en realizar un levantamiento de la situación actual de este tema efectuando una revisión comprensiva de la literatura en los campos de; identificación a través demarcadores de superficie, aislamiento por medio de mecanismos de digestión enzimática o explante, almacenamiento atendiendo a la necesidad de suprimir el uso de suero fetal bovino como medio de cultivo en un esfuerzo por avanzar hacia aplicaciones terapéuticas, banca o criopreservación destacando nuevas experiencia en este campo como lo es la criopreservación de piezas dentales completas gracias a la tecnología láser Nd:YAG. Y, finalmente, las aplicaciones clínicas que promete este grupo de células a través de la medicina regenerativa y la ingeniería tisular tanto en el campo de la odontología como la medicina general.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Antecedentes y objetivos: La hiperhidrosis primaria afecta el 2,8% de la población de Estados Unidos. Condición que impacta el desarrollo social de los individuos afectados, ocasionando fobia social. Existen opciones disponibles para el tratamiento de la hiperhidrosis incluyendo medicamentos tópico, sistémico, inyectable y quirúrgico. El objetivo de ésta revisión sistemática de la literatura es determinar la efectividad y seguridad de los dispositivos de emisión de microondas, radiofrecuencia no ablativa y sistema de ultrasonido microfocalizado para el tratamiento de la hiperhidrosis primaria. Materiales y métodos: Se realizó una revisión sistemática de la literatura de artículos obtenidos de bases de datos: Medline, Cochrane, Embase, Ovid y Scielo. Se incluyeron ensayos clínicos aleatorizados controlados, ensayos cuasiexperimentales desde el 2011; donde evaluaran el uso de estos dispositivos en el manejo de hiperhidrosis primaria. Resultados: Se seleccionaron 21 artículos en total. Se encontró que con los tres dispositivos se logra una reducción significativa a puntajes entre 1 y 2 de la escala de Severidad de la Hiperhidrosis; en 3 estudios se encontró mejoría en la calidad de vida; los eventos adversos fueron transitorios, siendo más frecuentes con el dispositivo de emisión de microondas. Conclusión: Primera revisión sistemática de la literatura sobre el efecto de estos tres dispositivos en el manejo de hiperhidrosis. Se espera aportar a la literatura existente una recomendación acerca de la efectividad y seguridad de estos dispositivos para que sea aplicado en los pacientes con diagnóstico de hiperhidrosis primaria.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Antecedentes: La ocronosis Exógena (OE) es una enfermedad subdiagnosticada y de difícil manejo (1). El láser Q-Switched (QS) surge como una alternativa para el tratamiento de esta (2). Objetivo: Describir las características de los pacientes, del láser QS y los desenlaces en el tratamiento de OE. Métodos: Se realizó una búsqueda de la literatura en las bases PubMed, Embase, PMC, Scielo, Elselvier, BMJ Case Reports, Journal of Medical Case Reports, Cases Journal e International Medical Case Reports Journal, desde enero del 2000 a marzo del 2016, pacientes con ocronosis exógena, 18 a 70 años, tratados con láser QS. Los artículos fueron evaluados mediante la herramienta de evaluación de validez y valor educativo de reportes de caso descrito por Pierson (3). Resultados: Se encontraron 256 artículos, 63 fueron seleccionados: 28 repetidos y 31 no cumplieron criterios de inclusión. Se escogieron 4 artículos que reportan 12 casos de pacientes con ocronosis exógena diagnosticada mediante estudio histopatológico y tratada con láser QS. Discusión: Hay poca experiencia con el láser QS en OE. En la práctica clínica se usa para tatuajes y patologías pigmentarias dérmicas con resultados satisfactorios. El pigmento dérmico en OE y la corta duración de pulso de láser QS, podrían ser el pilar de tratamiento para OE. Conclusión: El láser QS puede ser útil para el tratamiento en OE, con nivel de evidencia 3 y grado de recomendación D. Se sugiere realizar estudios clínicos con mayor grado de evidencia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Las ventajas que la incorporación del láser ha proporcionado a la Odontología abarcan todos los ámbitos. Así, los láseres de Argón, de Nd:YAP y de Ho:YAG, tienen aplicaciones muy concretas y de gran interés tanto en el campo de la terapéutica dental como en la especialida de cirugía bucal. Las aplicaciones principales del láser de Argón se centran en la polimerización de los materiales de restauración, en la endodoncia y dentro del ámbito de la cirugía bucal, en el corte de tejidos blandos, principalmente para la exéresis de lesiones vasculares y pigmentadas. El láser de Nd:YAP se utiliza principalmente en el campo de la endodoncia y la periodoncia, y el láser de Ho:YAG se emplea en cirugía periapical y en la cirugía artroscópica de la articulación temporomandibular.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the intraocular pressure (IOP)-lowering effect of modified goniopuncture with the 532-nm Nd : YAG selective laser trabeculoplasty (SLT) laser on eyes after deep sclerectomy with collagen implant (DSCI). This was an interventional cased series. The effects of modified goniopuncture on eyes with insufficient IOP-lowering after DSCI were observed. Goniopuncture was performed using a Q-switched, frequency-doubled 532-nm Nd : YAG laser (SLT-goniopuncture, SLT-G). Outcome measures were amount of IOP-lowering and rapidity of decrease after laser intervention. In all, 10 eyes of 10 patients with a mean age of 71.0±7.7 (SD) years were treated with SLT-G. The mean time of SLT-G after DSCI procedure was 7.1±10.9 months. SLT-G decreased IOP from an average of 16.1±3.4 mm Hg to 14.2±2.8 mm Hg (after 15 min), 13.6±3.9 mm Hg (at 1 day), 12.5±4.1 mm Hg (at 1 month), and 12.6±2.5 (at 6 months) (P<0.0125). There were no complications related to the intervention. Patients in this series achieved an average 22.5% of IOP reduction after SLT-G. The use of the SLT laser appears to be an effective and safe alternative to the traditional Nd : YAG laser for goniopuncture in eyes after DSCI, with potential advantages related to non-perforation of trabeculo-descemet's membrane (TDM).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A depressed cladding waveguide with record low loss of 0.12 dB/cm is inscribed in YAG:Nd(0.3at.%) crystal by femtosecond laser pulses with an elliptical beam waist. The waveguide is formed by a set of parallel tracks which constitute the depressed cladding. It is a key element for compact and efficient CW waveguide laser operating at 1064 nm and pumped by a multimode laser diode. Special attention is paid to mechanical stress resulting from the inscription process. Numerical calculation of mode distribution and propagation loss with the elasto-optical effect taken into account leads to the conclusion that the depressed cladding is a dominating factor in waveguide mode formation, while the mechanical stress only slightly distorts waveguide modes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A depressed cladding waveguide with record low loss of 0.12 dB/cm is inscribed in YAG:Nd(0.3at.%). It is shown that depressed cladding is a dominating factor in waveguide formation, and mechanical stress has a minor contribution. © 2012 OSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dentine hypersensitivity (DH) is a painful condition and is a clinical challenge due to the different treatment strategies available. High-intensity lasers have been studied as a possible option. The aim of this randomized, controlled, double-blind clinical study was to evaluate the effects of Er:YAG and Er,Cr:YSGG lasers on DH. The study group comprised 28 subjects who met the inclusion criteria. A visual analogue scale was used to quantify sensitivity before treatment as baseline, immediately before and immediately after treatment, and 1 week and 1 month after treatment. Teeth were assigned to four groups: group 1 control (no treatment), group 2 Er:YAG laser treatment (2 Hz/32.4 mJ/5.9 J/cm(2)), group 3 Er,Cr:YSGG laser treatment (0.25 W/4.4 J/cm(2)), and group 4 Er,Cr:YSGG laser treatment (0.50 W/ 8.9 J/cm(2)). Data were collected and submitted to statistical analysis for both evaporative (air) and mechanical (probe) stimulation. For both the air and probe stimulation no differences were observed between the pretreatment sensitivities. With the evaporative stimulus, the pain level immediately after treatment was reduced; however, after this the values remained stable. Irradiation with the Er:YAG laser was associated with the lowest level of pain. With the mechanical stimulus, group 4 showed the most pronounced decrease in pain immediately after treatment; however, by the end of the study, pain levels had increased. Groups 1, 2 and 3 showed a reduction in pain that was significantly different from that in group 4 after the 4 weeks of clinical follow up. Based on the results and within the limits of this study, it can be concluded that none of the laser treatments studied was capable of completely eliminating pain, but the Er:YAG and Er,Cr:YSGG lasers are suitable for the treatment of DH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Er:YAG laser has been studied as a potential tool for restorative dentistry due to its ability to selectively remove oral hard tissue with minimal or no thermal damage to the surrounding tissues. The purpose of this study was to evaluate in vitro the tensile bond strength (TBS) of an adhesive/composite resin system to human enamel surfaces treated with 37% phosphoric acid, Er:YAG laser (lambda=2.94 mum) with a total energy of 16 J (80 mJ/pulse, 2Hz, 200 pulses, 250 ms pulse width), and Er:YAG laser followed by phosphoric acid etching. Analysis of the treated surfaces was performed by scanning electron microscopy (SEM) to assess morphological differences among the groups. TBS means (in MPa) were as follows: Er:YAG laser + acid (11.7 MPa) > acid (8.2 MPa) > Er:YAG laser (6.1 MPa), with the group treated with laser+acid being significantly from the other groups (p=0.0006 and p= 0.00019, respectively). The groups treated with acid alone and laser alone were significantly different from each other (p=0.0003). The SEM analysis revealed morphological changes that corroborate the TBS results, suggesting that the differences in TBS means among the groups are related to the different etching patterns produced by each type of surface treatment. The findings of this study indicate that the association between Er:YAG laser and phosphoric acid can be used as a valuable resource to increase bond strength to laser-prepared enamel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effectiveness of combined ureteroscopic holmium YAG lithotripsy for renal calculi associated with ipsilateral ureteral stones. Materials and Methods: Between August 2002 and March 2007, retrograde flexible ureteroscopic stone treatment was attempted in 351 cases. Indication for treatment was concurrent symptomatic ureteral stones in 63 patients (group I). Additional operative time and perioperative complication rates were compared to a group of 39 patients submitted to ureteroscopic treatment for ureteral calculi exclusively (group II). Results: Mean ureteral stone size was 8.0 +/- 2.6 mm and 8.1 +/- 3.4 mm for groups I and II, respectively. Mean operative time for group I was 67.9 +/- 29.5 minutes and for group 2 was 49.3 +/- 13.2 minutes (p < 0.001). Flexible ureteroscopic therapy for renal calculi increased 18 minutes in the mean operative time. The overall complication rate was 3.1% and 2.5% for groups I and II, respectively (p = 0.87). Mean renal stone size was 10.7 +/- 6.4 mm, overall stone free rate in group I was 81%. However, considering only patients with renal stones smaller than 15 mm, the stone free rate was 88%. Successful treatment occurred in 81% of patients presenting lower pole stones, but only 76% of patients with multiple renal stones became stone free. As expected, stone free rate showed a significant negative correlation with renal stone size (p = 0.03; r = -0.36). Logistic regression model indicated an independent association of renal stones smaller than 15 mm and stone free rate (OR = 13.5; p = 0.01). Conclusion: Combined ureteroscopic treatment for ureteral and ipsilateral renal calculi is a safe and attractive option for patients presenting for symptomatic ureteral stone and ipsilateral renal calculi smaller than 15 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of this study was to evaluate the influence of different Er:YAG laser (lambda = 2.94 mu m) energy parameters on the microtensile bond strength (mu TBS) and superficial morphology of bovine enamel bleached with 16% carbamide peroxide. Background: Laser irradiation could improve adhesion to bleached enamel surfaces. Methods: Sixty bovine enamel blocks (7x3x3 mm(3)) were randomly assigned to six groups according to enamel preparation procedures (n = 10): G1-bleaching and Er:YAG laser irradiation with 25.52 J/cm(2) (laser A, LA); G2-bleaching and Er:YAG laser irradiation with 4.42J/cm(2) (laser B, LB); G3-bleaching; G4-Er:YAG laser irradiation with 25.52 J/cm(2); G5-Er:YAG laser irradiation with 4.42J/cm(2); G6-control, no treatment. G1 to G3 were bleached for 6 h during 21 days. Afterwards, enamel surfaces in all groups were slightly abraded with 600-grit SiC papers and G1, G2, G4 and G5 were irradiated according to each protocol. Enamel blocks were then restored with an etch-and-rinse adhesive system and a 4-mm thick composite buildup was made in two increments (n = 9). After 24 h, restored blocks were serially sectioned with a cross-section area of similar to 1 mm(2) at the bonded interface and tested in tension in a universal testing machine (1 mm/min). Failure mode was determined at a magnification of x100 using a stereomicroscope. One treated block of each group was selected for scanning electron microscopy (SEM) analysis. mu TBS data were analyzed by two-way ANOVA and no statistical differences were observed among groups. Results: Mean bond strengths (SD) in MPa were: G1-30.4(6.2); G2-27.9(8.5); G3-32.3(3.9); G4-23.7(5.8); G5-29.3(6.0); G6-29.1(6.1). A large number of adhesive failures was recorded for bleached and irradiated enamel surfaces. Conclusions: Bleached enamel surfaces mu TBS values were not significantly different from those of unbleached enamel. Even though Er:YAG laser irradiation with both parameters had no influence on mu TBS for bleached and unbleached enamel, SEM analysis revealed that Er:YAG laser irradiation with 25.52J/cm(2) should not be recommended, as enamel ablation was observed, whereas irradiation with 4.42J/cm(2) did not promote any remarkable changes on enamel surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this in vitro study was to evaluate the dentine root surface roughness and the adherence of Streptococcus sanguinis (ATCC 10556) after treatment with an ultrasonic system, Er:YAG laser, or manual curette. Background Data: Bacterial adhesion and formation of dental biofilm after scaling and root planing may be a challenge to the long-term stability of periodontal therapy. Materials and Methods: Forty flattened bovine roots were randomly assigned to one of the following groups: ultrasonic system (n = 10); Er:YAG laser (n = 10); manual curette (n = 10); or control untreated roots (n = 10). The mean surface roughness (Ra, mu m) of the specimens before and after exposure to each treatment was determined using a surface profilometer. In addition, S. sanguinis was grown on the treated and untreated specimens and the amounts of retained bacteria on the surfaces were measured by culture method. Results: All treatments increased the Ra; however, the roughest surface was produced by the curettes. In addition, the specimens treated with curettes showed the highest S. sanguinis adhesion. There was a significant positive correlation between roughness values and bacterial cells counts. Conclusion: S. sanguinis adhesion was the highest on the curette-treated dentine root surfaces, which also presented the greatest surface roughness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of the present study was to compare the in vitro effects of the Er:YAG laser, an ultrasonic system, and manual curette on dentine root surface by roughness and micro-morphological analysis. Materials and Methods: Thirty-six flattened bovine roots were randomly assigned to one of the following groups: group 1 (n = 12): Er: YAG laser ( 2940 nm), 120 mJ/pulse, 10 Hz, 8.4 J/cm(2); group 2 ( n = 12): ultrasonic system; and group 3 ( n = 12): manual curette. The mean surface roughness (Ra) of each sample was measured using a profilometer before and after the treatments. The micro-morphology of the treated and untreated ( control) root surfaces was evaluated with scanning electron microscopy (SEM) at 50 x and 1000 x magnification. Results: Analysis with the profilometer showed that for equal times of instrumentation, the smoothest surfaces were produced by the Er: YAG laser and the ultrasonic system, followed by the curette ( p < 0.05). Morphological analyses demonstrated that treatment with the Er: YAG laser produced some areas with an irregular surface, craters, and ablation of the intertubular dentin. The smear layer was removed and dentine tubules were opened by both curettes and the ultrasonic system. The micro-morphology of the dentine root surface after ultrasonic treatment, however, demonstrated randomly distributed areas cratering. Conclusion: All instruments increased the roughness of the dentine root surface after treatment; however, the curette produced rougher surfaces than the other devices. SEM analysis revealed distinct root surface profiles produced by the three devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of laser irradiation for dental surface treatment may increase tooth-composite bond strength. Its use on bleached teeth may decrease the waiting time between bleaching and restorative procedures. Objective: This study aimed to evaluate the bond strength between a composite resin and bovine enamel bleached with 35% hydrogen peroxide and etched with Er:YAG laser. Materials and Methods: Thirty bovine teeth were randomly divided into six groups (n = 5): G1, unbleached and restored 24 h after storage in artificial saliva, etching with 35% phosphoric acid (PA) (control); G2, unbleached and restored 24 h after storage in artificial saliva, etching with Er:YAG laser and 35% PA; G3, bleached and restored immediately afterward, etching with 35% PA; G4, bleached and restored 24 h after bleaching, etching with 35% PA; G5, bleached and restored immediately afterward, etching with Er:YAG and 35% PA laser; G6, bleached and restored 24 h after bleaching, etching with Er:YAG laser and 35% PA. Bond strength was quantitatively evaluated by microtensile test (1.0 mm/min). Data were submitted to statistical analysis using ANOVA and Tukey tests (alpha - 0.05). Results: Bond strength values (MPa) were G1, 26.17 +/- 4.44; G2, 28.87 +/- 3.94; G3, 17.25 +/- 4.58; G4, 21.93 +/- 5.02; G5, 16.69 +/- 2.31; and G6, 29.06 +/- 8.31. There was no statistically significant difference among groups G1, G2, and G6 (p - 0.119), which presented higher bond strength than group G4, followed by groups G3 and G5. Conclusion: Er:YAG irradiation of bleached surfaces may favor bonding procedures when performed 24 h after bleaching.