902 resultados para Multivariate measurement model


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Standard methods for the analysis of linear latent variable models oftenrely on the assumption that the vector of observed variables is normallydistributed. This normality assumption (NA) plays a crucial role inassessingoptimality of estimates, in computing standard errors, and in designinganasymptotic chi-square goodness-of-fit test. The asymptotic validity of NAinferences when the data deviates from normality has been calledasymptoticrobustness. In the present paper we extend previous work on asymptoticrobustnessto a general context of multi-sample analysis of linear latent variablemodels,with a latent component of the model allowed to be fixed across(hypothetical)sample replications, and with the asymptotic covariance matrix of thesamplemoments not necessarily finite. We will show that, under certainconditions,the matrix $\Gamma$ of asymptotic variances of the analyzed samplemomentscan be substituted by a matrix $\Omega$ that is a function only of thecross-product moments of the observed variables. The main advantage of thisis thatinferences based on $\Omega$ are readily available in standard softwareforcovariance structure analysis, and do not require to compute samplefourth-order moments. An illustration with simulated data in the context ofregressionwith errors in variables will be presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To determine clinical and ultrasonographic predictors of joint replacement surgery across Europe in primary osteoarthritis (OA) of the knee. METHODS: This was a 3-year prospective study of a painful OA knee cohort (from a EULAR-sponsored, multicentre study). All subjects had clinical evaluation, radiographs and ultrasonography (US) at study entry. The rate of knee replacement surgery over the 3-year follow-up period was determined using Kaplan-Meier survival data analyses. Predictive factors for joint replacement were identified by univariate log-rank test then multivariate analysis using a Cox proportional-hazards regression model. Potential baseline predictors included demographic, clinical, radiographic and US features. RESULTS: Of the 600 original patients, 531 (88.5%), mean age 67+/-10 years, mean disease duration 6.1+/-6.9 years, had follow-up data and were analysed. During follow-up (median 3 years; range 0-4 years), knee replacement was done or required for 94 patients (estimated event rate of 17.7%). In the multivariate analysis, predictors of joint replacement were as follows: Kellgren and Lawrence radiographic grade (grade > or =III vs <III, hazards ratio (HR) = 4.08 (95% CI 2.34 to 7.12), p<0.0001); ultrasonographic knee effusion (> or =4 mm vs <4 mm) (HR = 2.63 (95% CI 1.70 to 4.06), p<0.0001); knee pain intensity on a 0-100 mm visual analogue scale (> or =60 vs <60) (HR = 1.81 (95% CI 1.15 to 2.83), p=0.01) and disease duration (> or =5 years vs <5 years) (HR=1.63 (95% CI 1.08 to 2.47), p=0.02). Clinically detected effusion and US synovitis were not associated with joint replacement in the univariate analysis. CONCLUSION: Longitudinal evaluation of this OA cohort demonstrated significant progression to joint replacement. In addition to severity of radiographic damage and pain, US-detected effusion was a predictor of subsequent joint replacement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method to evaluate cyclical models not requiring knowledge of the DGP and the exact specificationof the aggregate decision rules is proposed. We derive robust restrictions in a class of models; use someto identify structural shocks in the data and others to evaluate the class or contrast sub-models. Theapproach has good properties, even in small samples, and when the class of models is misspecified. Themethod is used to sort out the relevance of a certain friction (the presence of rule-of-thumb consumers)in a standard class of models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A mixture of 3 MAbs directed against 3 different CEA epitopes was radiolabelled with 131I and used for the treatment of a human colon carcinoma transplanted s.c. into nude mice. Intact MAbs and F(ab')2 fragments were mixed because it had been shown by autoradiography that these 2 antibody forms can penetrate into different areas of the tumor nodule. Ten days after transplantation of colon tumor T380 a single dose of 600 microCi of 131I MAbs was injected i.v. The tumor grafts were well established (as evidenced by exponential growth in untreated mice) and their size continued to increase up to 6 days after radiolabelled antibody injection. Tumor shrinking was then observed lasting for 4-12 weeks. In a control group injected with 600 microCi of 131I coupled to irrelevant monoclonal IgG, tumor growth was delayed, but no regression was observed. Tumors of mice injected with the corresponding amount of unlabelled antibodies grew like those of untreated mice. Based on measurements of the effective whole-body half-life of injected 131I, the mean radiation dose received by the animals was calculated to be 382 rads for the antibody group and 478 rads for the normal IgG controls. The genetically immunodeficient animals exhibited no increase in mortality, and only limited bone-marrow toxicity was observed. Direct measurement of radioactivity in mice dissected 1, 3 and 7 days after 131I-MAb injection showed that 25, 7.2 and 2.2% of injected dose were recovered per gram of tumor, the mean radiation dose delivered to the tumor being thus more than 5,000 rads. These experiments show that therapeutic doses of radioactivity can be selectively directed to human colon carcinoma by i.v. injection of 131I-labelled anti-CEA MAbs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper combines multivariate density forecasts of output growth, inflationand interest rates from a suite of models. An out-of-sample weighting scheme based onthe predictive likelihood as proposed by Eklund and Karlsson (2005) and Andersson andKarlsson (2007) is used to combine the models. Three classes of models are considered: aBayesian vector autoregression (BVAR), a factor-augmented vector autoregression (FAVAR)and a medium-scale dynamic stochastic general equilibrium (DSGE) model. Using Australiandata, we find that, at short forecast horizons, the Bayesian VAR model is assignedthe most weight, while at intermediate and longer horizons the factor model is preferred.The DSGE model is assigned little weight at all horizons, a result that can be attributedto the DSGE model producing density forecasts that are very wide when compared withthe actual distribution of observations. While a density forecast evaluation exercise revealslittle formal evidence that the optimally combined densities are superior to those from thebest-performing individual model, or a simple equal-weighting scheme, this may be a resultof the short sample available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accomplish high quality of final products in pharmaceutical industry is a challenge that requires the control and supervision of all the manufacturing steps. This request created the necessity of developing fast and accurate analytical methods. Near infrared spectroscopy together with chemometrics, fulfill this growing demand. The high speed providing relevant information and the versatility of its application to different types of samples lead these combined techniques as one of the most appropriated. This study is focused on the development of a calibration model able to determine amounts of API from industrial granulates using NIR, chemometrics and process spectra methodology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work aimed to measure and analyze total rainfall (P), rainfall intensity and five-day antecedent rainfall effects on runoff (R); to compare measured and simulated R values using the Soil Conservation Service Curve Number method (CN) for each rainfall event; and to establish average R/P ratios for observed R values. A one-year (07/01/96 to 06/30/97) rainfall-runoff data study was carried out in the Capetinga watershed (962.4 ha), located at the Federal District of Brazil, 47° 52' longitude West and 15° 52' latitude South. Soils of the watershed were predominantly covered by natural vegetation. Total rainfall and runoff for the period were 1,744 and 52.5 mm, respectively, providing R/P of 3% and suggesting that watershed physical characteristics favored water infiltration into the soil. A multivariate regression analysis for 31 main rainfall-runoff events totaling 781.9 and 51.0 mm, respectively, indicated that the amount of runoff was only dependent upon rainfall volume. Simulated values of total runoff were underestimated about 15% when using CN method and an area-weighted average of the CN based on published values. On the other hand, when average values of CN were calculated for the watershed, total runoff was overestimated about 39%, suggesting that CN method shoud be used with care in areas under natural vegetation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The predictive potential of six selected factors was assessed in 72 patients with primary myelodysplastic syndrome using univariate and multivariate logistic regression analysis of survival at 18 months. Factors were age (above median of 69 years), dysplastic features in the three myeloid bone marrow cell lineages, presence of chromosome defects, all metaphases abnormal, double or complex chromosome defects (C23), and a Bournemouth score of 2, 3, or 4 (B234). In the multivariate approach, B234 and C23 proved to be significantly associated with a reduction in the survival probability. The similarity of the regression coefficients associated with these two factors means that they have about the same weight. Consequently, the model was simplified by counting the number of factors (0, 1, or 2) present in each patient, thus generating a scoring system called the Lausanne-Bournemouth score (LB score). The LB score combines the well-recognized and easy-to-use Bournemouth score (B score) with the chromosome defect complexity, C23 constituting an additional indicator of patient outcome. The predicted risk of death within 18 months calculated from the model is as follows: 7.1% (confidence interval: 1.7-24.8) for patients with an LB score of 0, 60.1% (44.7-73.8) for an LB score of 1, and 96.8% (84.5-99.4) for an LB score of 2. The scoring system presented here has several interesting features. The LB score may improve the predictive value of the B score, as it is able to recognize two prognostic groups in the intermediate risk category of patients with B scores of 2 or 3. It has also the ability to identify two distinct prognostic subclasses among RAEB and possibly CMML patients. In addition to its above-described usefulness in the prognostic evaluation, the LB score may bring new insights into the understanding of evolution patterns in MDS. We used the combination of the B score and chromosome complexity to define four classes which may be considered four possible states of myelodysplasia and which describe two distinct evolutional pathways.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Developing a novel technique for the efficient, noninvasive clinical evaluation of bone microarchitecture remains both crucial and challenging. The trabecular bone score (TBS) is a new gray-level texture measurement that is applicable to dual-energy X-ray absorptiometry (DXA) images. Significant correlations between TBS and standard 3-dimensional (3D) parameters of bone microarchitecture have been obtained using a numerical simulation approach. The main objective of this study was to empirically evaluate such correlations in anteroposterior spine DXA images. Thirty dried human cadaver vertebrae were evaluated. Micro-computed tomography acquisitions of the bone pieces were obtained at an isotropic resolution of 93μm. Standard parameters of bone microarchitecture were evaluated in a defined region within the vertebral body, excluding cortical bone. The bone pieces were measured on a Prodigy DXA system (GE Medical-Lunar, Madison, WI), using a custom-made positioning device and experimental setup. Significant correlations were detected between TBS and 3D parameters of bone microarchitecture, mostly independent of any correlation between TBS and bone mineral density (BMD). The greatest correlation was between TBS and connectivity density, with TBS explaining roughly 67.2% of the variance. Based on multivariate linear regression modeling, we have established a model to allow for the interpretation of the relationship between TBS and 3D bone microarchitecture parameters. This model indicates that TBS adds greater value and power of differentiation between samples with similar BMDs but different bone microarchitectures. It has been shown that it is possible to estimate bone microarchitecture status derived from DXA imaging using TBS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To describe the methodology of Confirmatory Factor Analyis for categorical items and to apply this methodology to evaluate the factor structure and invariance of the WHO-Disability Assessment Schedule (WHODAS-II) questionnaire, developed by the World HealthOrganization.Methods: Data used for the analysis come from the European Study of Mental Disorders(ESEMeD), a cross-sectional interview to a representative sample of the general population of 6 european countries (n=8796). Respondents were administered a modified version of theWHODAS-II, that measures functional disability in the previous 30 days in 6 differentdimensions: Understanding and Communicating; Self-Care, Getting Around, Getting Along withOthers, Life Activities and Participation. The questionnaire includes two types of items: 22severity items (5 points likert) and 8 frequency items (continuous). An Exploratory factoranalysis (EFA) with promax rotation was conducted on a random 50% of the sample. Theremaining half of the sample was used to perform a Confirmatory Factor Analysis (CFA) inorder to compare three different models: (a) the model suggested by the results obtained in theEFA; (b) the theoretical model suggested by the WHO with 6 dimensions; (c) a reduced modelequivalent to model b where 4 of the frequency items are excluded. Moreover, a second orderfactor was also evaluated. Finally, a CFA with covariates was estimated in order to evaluatemeasurement invariance of the items between Mediterranean and non-mediterranean countries.Results: The solution that provided better results in the EFA was that containing 7 factors. Twoof the frequency items presented high factor loadings in the same factor, and one of thempresented factor loadings smaller than 0.3 with all the factors. With regard to the CFA, thereduced model (model c) presented the best goodness of fit results (CFI=0.992,TLI=0.996,RMSEA=0.024). The second order factor structure presented adequate goodness of fit (CFI=0.987,TLI=0.991, RMSEA=0.036). Measurement non-invariance was detected for one of the items of thequestionnaire (FD20 ¿ Embarrassment due to health problems).Conclusions: AFC confirmed the initial hypothesis about the factorial structure of the WHODAS-II in 6factors. The second order factor supports the existence of a global dimension of disability. The use of 4of the frequency items is not recommended in the scoring of the corresponding dimensions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In studies of the natural history of HIV-1 infection, the time scale of primary interest is the time since infection. Unfortunately, this time is very often unknown for HIV infection and using the follow-up time instead of the time since infection is likely to provide biased results because of onset confounding. Laboratory markers such as the CD4 T-cell count carry important information concerning disease progression and can be used to predict the unknown date of infection. Previous work on this topic has made use of only one CD4 measurement or based the imputation on incident patients only. However, because of considerable intrinsic variability in CD4 levels and because incident cases are different from prevalent cases, back calculation based on only one CD4 determination per person or on characteristics of the incident sub-cohort may provide unreliable results. Therefore, we propose a methodology based on the repeated individual CD4 T-cells marker measurements that use both incident and prevalent cases to impute the unknown date of infection. Our approach uses joint modelling of the time since infection, the CD4 time path and the drop-out process. This methodology has been applied to estimate the CD4 slope and impute the unknown date of infection in HIV patients from the Swiss HIV Cohort Study. A procedure based on the comparison of different slope estimates is proposed to assess the goodness of fit of the imputation. Results of simulation studies indicated that the imputation procedure worked well, despite the intrinsic high volatility of the CD4 marker.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Spanning avalanches in the 3D Gaussian Random Field Ising Model (3D-GRFIM) with metastable dynamics at T=0 have been studied. Statistical analysis of the field values for which avalanches occur has enabled a Finite-Size Scaling (FSS) study of the avalanche density to be performed. Furthermore, a direct measurement of the geometrical properties of the avalanches has confirmed an earlier hypothesis that several types of spanning avalanches with two different fractal dimensions coexist at the critical point. We finally compare the phase diagram of the 3D-GRFIM with metastable dynamics with the same model in equilibrium at T=0.