973 resultados para Minimally invasive surgery


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Vertebroplasty is a minimally invasive procedure with many benefits; however, the procedure is not without risks and potential complications, of which leakage of the cement out of the vertebral body and into the surrounding tissues is one of the most serious. Cement can leak into the spinal canal, venous system, soft tissues, lungs and intradiscal space, causing serious neurological complications, tissue necrosis or pulmonary embolism. We present a method for automatic segmentation and tracking of bone cement during vertebroplasty procedures, as a first step towards developing a warning system to avoid cement leakage outside the vertebral body. We show that by using active contours based on level sets the shape of the injected cement can be accurately detected. The model has been improved for segmentation as proposed in our previous work by including a term that restricts the level set function to the vertebral body. The method has been applied to a set of real intra-operative X-ray images and the results show that the algorithm can successfully detect different shapes with blurred and not well-defined boundaries, where the classical active contours segmentation is not applicable. The method has been positively evaluated by physicians.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Surgical treatment of mitral leaflet prolapse using artificial neochordae shows excellent outcomes. Upcoming devices attempt the same treatment in a minimally invasive way but target the left ventricular apex as an anchoring point, rather than the tip of the corresponding papillary muscle. In this study, cine cardiac magnetic resonance imaging was used to compare these 2 different anchoring positions and their dynamic relationship with the mitral leaflets.

Relevância:

90.00% 90.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To report use of a pinless external fixator (PEF) for unilateral mandibular fractures in 9 equids. STUDY DESIGN: Case series. ANIMALS: Equids (n=9) with unilateral mandibular fractures. METHODS: All fractures were stabilized with the AO/ASIF PEF using a minimum of 4 clamps, under general anesthesia. Fracture configuration, complications, outcome, and owner satisfaction were evaluated. RESULTS: All fractures were stabilized; 2 equids were euthanatized; 1 because of an inability to stand after surgery and 1 because of owner decision after PEF dislodgement. Seven repairs healed with good outcome and owner satisfaction. Complications included dislodgement of the PEF (3), bone sequestration (3), and weight loss (1). Drainage associated with repair resolved after removal of sequestra and clamps. CONCLUSIONS: Stabilization of unilateral mandibular fractures with the PEF in horses was minimally invasive with minimal risk of tooth root interference; however, after care is time consuming. CLINICAL RELEVANCE: PEF is an alternative technique for stabilizing unilateral mandibular fractures in equids.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The conservative treatment of acute necrotizing pancreatitis has greatly improved due to broad antibiotic treatment and improved organ support in intensive care units. Nevertheless, infected necrosis or persistent multi-organ dysfunction are predictors of poor outcome. In these patients, there is still a need to perform necrosectomy. Open surgery results in extensive operative trauma and is associated with high morbidity and mortality. Therefore, several minimally invasive techniques have been developed recently. Retroperitoneal necrosectomy has been shown to be safe and to reduce morbidity and mortality compared to the open procedure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pelvic lymph node dissection is an integral part of the radical cystectomy procedure for patients with muscle-invasive bladder cancer. The optimal extent of the lymphadenectomy (LND) and mainly the proximal template boundary remain controversial issues. In view of the existing mapping studies and retrospective analyses, extended LND up to the mid-upper third of the common iliac vessels appears to provide further prognostic and therapeutic benefit and therefore should be defined as standard LND. This applies for all procedures irrespective of the choice of surgical approach (open surgery, minimally invasive approach). In this context total lymph node count is not a quality criterion because nodal yield is overly influenced by the individual patient's anatomy, surgical technique, template applied and pathological work-up. Consecutively, considerable inter-institutional differences result, which render any comparison impossible. Lymph node density is thought to be a superior prognostic factor, but it is similarly influenced by the above-mentioned factors. Concerning molecular techniques to improve the sensitivity of postoperative nodal staging further research is necessary. The two ongoing prospective randomized trials will potentially help to further define the optimal LND template.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Hyponatremia is the most common electrolyte disorder in hospitalized patients and is known to be associated with increased mortality. The administration of antegrade single-shot, up to two liters, histidine-tryptophane-ketoglutarate (HTK) solution for adequate electromechanical cardiac arrest and myocardial preservation during minimally invasive aortic valve replacement (MIAVR) is a standard procedure. We aimed to determine the impact of HTK infusion on electrolyte and acid–base balance. Methods In this retrospective analysis we reviewed data on patient characteristics, type of surgery, arterial blood gas analysis during surgery and intra-/postoperative laboratory results of patients receiving surgery for MIAVR at a large tertiary care university hospital. Results A total of 25 patients were included in the study. All patients were normonatremic at start of surgery. All patients developed hyponatremia after administration of HTK solution with a significant drop of serum sodium of 15 mmol/L (p < 0.01). Measured osmolality did not change during all times of surgery compared to start of surgery (p = 0.28 – p = 0.79), indicating isotonic hyponatremia. After administration of HTK solution pH fell significantly due to development of metabolic acidosis. Conclusions Acute hyponatremia during cardioplegia with HTK solution is isotonic and should probably not be corrected without presence of hypotonicity as confirmed by measurement of serum osmolality.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE : For the facilitation of minimally invasive robotically performed direct cochlea access (DCA) procedure, a surgical planning tool which enables the surgeon to define landmarks for patient-to-image registration, identify the necessary anatomical structures and define a safe DCA trajectory using patient image data (typically computed tomography (CT) or cone beam CT) is required. To this end, a dedicated end-to-end software planning system for the planning of DCA procedures that addresses current deficiencies has been developed. METHODS :    Efficient and robust anatomical segmentation is achieved through the implementation of semiautomatic algorithms; high-accuracy patient-to-image registration is achieved via an automated model-based fiducial detection algorithm and functionality for the interactive definition of a safe drilling trajectory based on case-specific drill positioning uncertainty calculations was developed. RESULTS :    The accuracy and safety of the presented software tool were validated during the conduction of eight DCA procedures performed on cadaver heads. The plan for each ear was completed in less than 20 min, and no damage to vital structures occurred during the procedures. The integrated fiducial detection functionality enabled final positioning accuracies of [Formula: see text] mm. CONCLUSIONS :    Results of this study demonstrated that the proposed software system could aid in the safe planning of a DCA tunnel within an acceptable time.

Relevância:

90.00% 90.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Standard endovascular repair of abdominal aortic aneurysm (AAA) has been shown to be associated with significant advantages compared with conventional surgery in the perioperative time frame related to the minimally invasive nature of the procedure. Given the encouraging long-term results of endovascular AAA repair, this method is increasingly applied to patients with complex AAA anatomies. The present article reviews the indications for branched and fenestrated endografts in various aortic pathologic processes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To report our experience with the successful removal of visible tension-free vaginal tape (TVT) by standard transurethral electroresection, as intravesical tape erosion after TVT is a rare complication, and removal can be challenging, with few cases reported. PATIENTS AND METHODS: Five patients presenting with TVT erosion into the bladder were treated at our institutions from December 2004 to July 2007; all had standard transurethral electroresection. Their records were reviewed retrospectively to retrieve data on presenting symptoms, diagnostic tests, surgical procedures and outcomes. RESULTS: The median (range) interval between the TVT procedure and the onset of symptoms was 17 (1-32) months. The predominant symptoms were painful micturition, recurrent urinary tract infection (UTI), urgency and urge incontinence. There were no complications during surgery. The storage symptoms and UTI resolved completely after removing the eroded mesh in all but one patient. Cystoscopy at 1 month after surgery showed complete healing of the bladder mucosa. CONCLUSION: Although TVT erosion into the bladder is rare, persistent symptoms, particularly recurrent UTIs, must raise some suspicion for this condition. Standard transurethral electroresection seems to be a safe, simple, minimally invasive and successful treatment option for TVT removal.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Newborns with hypoplastic left heart syndrome (HLHS) or right heart syndrome or other malformations with a single ventricle physiology and associated hypoplasia of the great arteries continue to be a challenge in terms of survival. The vast majority of these forms of congenital heart defects relate to abnormal morphogenesis during early intrauterine development and can be diagnosed accurately by fetal echocardiography. Early knowledge of these conditions not only permits a better understanding of the progression of these malformations but encourages some researchers to explore new minimally invasive therapeutic options with a view to early pre- and postnatal cardiac palliation. DATA SOURCES: PubMed database was searched with terms of "congenital heart defects", "fetal echocardiography" and "neonatal cardiac surgery". RESULTS: At present, early prenatal detection has been applied for monitoring pregnancy to avoid intrauterine cardiac decompensation. In principle, the majority of congenital heart defects can be diagnosed by prenatal echocardiography and the detection rate is 85%-95% at tertiary perinatal centers. The majority, particularly of complex congenital lesions, show a steadily progressive course including subsequent secondary phenomena such as arrhythmias or myocardial insufficiency. So prenatal treatment of an abnormal fetus is an area of perinatal medicine that is undergoing a very dynamic development. Early postnatal treatment is established for some time, and prenatal intervention or palliation is at its best experimental stage in individual cases. CONCLUSION: The upcoming expansion of fetal cardiac intervention to ameliorate critically progressive fetal lesions intensifies the need to address issues about the adequacy of technological assessment and patient selection as well as the morbidity of those who undergo these procedures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechanical parameters of the spinal segment. Investigation of the viscoelastic properties as well as the dynamic spinal stiffness was performed during a minimally invasive procedure (microdiscectomy) on five patients. Measurements were performed intraoperatively and the protocol consisted of a dynamic part, where spinal stiffness was computed, and a static part, where force relaxation of the segment under constant elongation was studied. The repeatability of the measurement procedure was demonstrated with five replicated tests. The spinal segment tissues were found to have viscoelastic properties. Preliminary tests confirmed a decrease in stiffness after decompression surgery. Patients with non-relaxed muscles showed higher stiffness and relaxation rate compared to patients with relaxed muscles, which can be explained by the contraction and relaxation reflex of muscles under fast and then static elongation. The results show the usefulness of the biomechanical characterization of the human lumbar spinal segment to improve the understanding of the contribution of individual anatomical structures to spinal stability.