945 resultados para MRI-guided cryoablation
Resumo:
Background: Cocoa is rich in flavonoids, has anti-oxidative properties and increases the bioavailability of nitric oxide (NO). Adequate renal tissue oxygenation is crucial for the maintenance of renal function. The goal of this study was to investigate the effect of cocoa-rich dark chocolate (DC) on renal tissue oxygenation in humans, as compared to flavonoid-poor white chocolate (WC). Methods: Ten healthy volunteers with preserved kidney function (mean age ± SD 35 ± 12 years, 70% women, BMI 21 ± 3 kg/m2) underwent blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) before and 2 hours after the ingestion of 1 g/kg of DC (70% cocoa). Renal tissue oxygenation was determined by the measurement of R2* maps on 4 coronal slices covering both kidneys. The mean R2* (= 1/T2*) values in the medulla and cortex were calculated, a low R2* indicating high tissue oxygenation. Eight participants also underwent BOLD-MRI at least 1 week later, before and 2 hours after the intake of 1 g/kg WC. Results: The mean medullary R2* was lower after DC intake compared to baseline (28.2 ± 1.3 s-1 vs. 29.6 ± 1.3 s-1, p = 0.04), whereas cortical and medullary R2* values did not change after WC intake. The change in medullary R2* correlated with the level of circulating (epi)catechines, metabolites of flavonoids (r = 0.74, p = 0.037), and was independent of plasma renin activity. Conclusion: This study suggests for the first time an increase of renal medullary oxygenation after intake of dark chocolate. Whether this is linked to flavonoid-induced changes in renal perfusion or oxygen consumption, and whether cocoa has potentially renoprotective properties, merits further study.
Resumo:
Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.
Resumo:
BACKGROUND AND PURPOSE: Patients with symptoms of semicircular canal dehiscence often undergo both CT and MR imaging. We assessed whether FIESTA can replace temporal bone CT in evaluating patients for SC dehiscence. MATERIALS AND METHODS: We retrospectively reviewed 112 consecutive patients (224 ears) with vestibulocochlear symptoms who underwent concurrent MR imaging and CT of the temporal bones between 2007 and 2009. MR imaging protocol included a FIESTA sequence covering the temporal bone (axial 0.8-mm section thickness, 0.4-mm spacing, coronal/oblique reformations; 41 patients at 1.5T, 71 patients at 3T). CT was performed on a 64-row multidetector row scanner (0.625-mm axial acquisition, with coronal/oblique reformations). Both ears of each patient were evaluated for dehiscence of the superior and posterior semicircular canals in consensual fashion by 2 neuroradiologists. Analysis of the FIESTA sequence and reformations was performed first for the MR imaging evaluation. CT evaluation was performed at least 2 weeks after the MR imaging review, resulting in a blinded comparison of CT with MR imaging. CT was used as the reference standard to evaluate the MR imaging results. RESULTS: For SSC dehiscence, MR imaging sensitivity was 100%, specificity was 96.5%, positive predictive value was 61.1%, and negative predictive value was 100% in comparison with CT. For PSC dehiscence, MR imaging sensitivity was 100%, specificity was 99.1%, positive predictive value was 33.3%, and negative predictive value was 100% in comparison with CT. CONCLUSIONS: MR imaging, with a sensitivity and negative predictive value of 100%, conclusively excludes SSC or PSC dehiscence. Negative findings on MR imaging preclude the need for CT to detect SC dehiscence. Only patients with positive findings on MR imaging should undergo CT evaluation.
Resumo:
PURPOSE: To examine the reproducibility of carotid artery dimension measurements using 3T MRI. MATERIALS AND METHODS: Ten healthy volunteers underwent three scans on two occasions for assessment of total vessel wall area (TVWA), total luminal area (TLA), and minimum (MinT) and maximum (MaxT) vessel wall thickness. A double inversion-recovery (IR) fast gradient-echo (FGRE) sequence was used on a commercial 3T system. During the first visit the subjects were scanned twice. The third scan was performed at least four days later. One observer traced all scans, and a second observer retraced the first scan series. RESULTS: For TVWA an interclass correlation (ICC) of 0.994 was calculated with all three scans taken into account. The interobserver ICC was 0.984. The agreement between the scans for TLA showed an ICC of 0.982 with an interobserver ICC of 0.998. For MinT and MaxT an ICC of 0.843 and 0.935 were calculated, with interobserver ICCs of 0.860 and 0.726, respectively. CONCLUSION: With the use of a commercial 3T MR system, TVWA, TLA, and wall thickness measurements of the carotid artery can be assessed with good reproducibility.
Resumo:
Purpose: To compare the additional informations obtainedwith axial and sagittal T2 weighted with fat saturation(T2FS) and T1 weighted with Gadolinium iv sequenceswith fat saturation (T1FSGd) to detect degenerativeinflammatory lumbar spine lesions.Materials and Methods: Our retrospective study included73 patients (365 lumbar levels) with lumbar spinedegenerative disease (25 males, 48 females, mean age56 years). MRI protocol was performed with T1 and T2weighted sagittal and T2 weighted axial sequences(standard protocol), axial and sagittal T2FS and T1FSGd.Images were independently analyzed by two musculoskeletalradiologists and a neurosurgeon. Two groups ofsequences were analyzed: standard + T2FS sequences(group 1), standard + T1FSGd sequences (group 2).Degenerative inflammatory lumbar spine lesions werenoted at each level in: anterior column (vertebralendplate), spinal canal (epidural and peri-radicular fat)and posterior column (facet joint with capsular recessand subchondral bone).Results: Degenerative inflammatory lesions were present in18% (66/365) of levels in group 1, and 48% (175/365) oflevels in group 2. In details, lesions were noted in group 1 and2 respectively:-in 44 and 66 levels for anterior column,-in22 and 131 levels for posterior column,-in 0 and 36 levelsfor spinal canal. All these differences were statisticallysignificant. Intra and Interobserver agreements were good.Conclusion: The T1FSGd sequence is more sensitive thanT2FS to show the degenerative inflammatory lumbar spinelesions, especially in spinal canal and posterior column.
Lack of MRI neurohypophyseal bright signal in a child with congenital nephrogenic diabetes insipidus
Resumo:
Congenital nephrogenic diabetes insipidus (CNDI) is a rare disease characterized by the inability of the kidney to respond to arginine vasopressin (AVP). The absence of the neurohypophyseal 'bright signal' on T1 sequence magnetic resonance imaging (MRI) is considered as an argument in favour of the diagnosis of central diabetes insipidus (CDI). This observation is challenged as we hereby present a case of a child diagnosed with CNDI and who did not present MRI pituitary bright signal. A 6-month-old male presented with failure to thrive, polyuria and polydypsia. Family history revealed that the mother, 35 years of age, had been presenting polydypsia and polyuria, and she was investigated at the age of 6 years with no concluding diagnosis. The patient's physical exam showed a weight of 5215 g (−3 DS) and clinical signs of dehydration. The patient's plasma sodium level was 155 mmol/L, osmolality 305 mOsm/kg and urine osmolality 150 mOsm/kg. Brain MRI showed in T1 sequences the absence of the posterior pituitary bright signal suggesting the diagnosis of CDI (Figure 1). The child was treated with synthetic AVP analogue 1-desamino-8-d-arginine vasopressin (DDAVP) without improvement, which led to the consideration of CNDI. The diagnosis was confirmed by an elevated serum level of AVP of 214 pmol/L (reference value ≤4.34 pmol/L) and by genetic analysis demonstrating and T106C mutation in the V2R (X-linked CNDI). The child was treated with thiazide diuretic and increased fluids with restricted sodium intake. This resulted in catch-up growth and improved neurological development. A follow-up MRI was performed 6 months after the start of therapy with the same technique. At that time, the child's weight had improved to 9310 g (−1.5 DS) corresponding to a gain of 22 g per day, and he did not present any clinical signs of dehydration and had a normal plasma level of sodium (140 mmol/L). MRI showed that the bright signal was still absent.
Resumo:
Several molecular therapies require the implantation of cells that secrete biotherapeutic molecules and imaging the location and microenvironment of the cellular implant to ascertain its function. We demonstrate noninvasive in vivo magnetic resonance imaging (MRI) of self-assembled microcontainers that are capable of cell encapsulation. Negative contrast was obtained to discern the microcontainer with MRI; positive contrast was obtained in the complete absence of background signal. MRI on a clinical scanner highlights the translational nature of this research. The microcontainers were loaded with cells that were dispersed in an extracellular matrix, and implanted both subcutaneously and in human tumor xenografts in SCID mice. MRI was performed on the implants, and microcontainers retrieved postimplantation showed cell viability both within and proximal to the implant. The microcontainers are characterized by their small size, three dimensionality, controlled porosity, ease of parallel fabrication, chemical and mechanical stability, and noninvasive traceability in vivo.
Resumo:
PURPOSE OF REVIEW: The safety and efficiency of trans catheter aortic valve implantation (TAVI) has been clearly demonstrated. In high-risk patients, the number of procedures is constantly increasing and in western European countries this procedure is employed in more than 30% of isolated aortic valve replacements. The literature, however, focusing on perioperative aortic root (AoR) rupture is rather limited to just a few reports. The aim of this review is to analyze the pathophysiology of AoR rupture during TAVI, stressing the implications of the morphology of the AoR for this devastating complication. RECENT FINDINGS: Currently, perioperative AoR rupture ranges between 0.5 and 1.5% during TAVI, with almost 100% mortality. Recently, valve oversizing and balloon dilatation in a calcified and small AoR were considered as the most important predictive factors for this complication. SUMMARY: The most fragile unit of the AoR is its anchoring substrate to the ostium of the left ventricle. This membranous structure is not involved in the degenerative process leading to aortic valve stenosis. Due to the TAVI and/or balloon dilatation of the calcium stationed on the three leaflets and their attachment, a lesion may result on this structure. And, as a consequence, there is rupture of the AoR.
Resumo:
BACKGROUND: To compare morphological gross tumor volumes (GTVs), defined as pre- and postoperative gadolinium enhancement on T1-weighted magnetic resonance imaging to biological tumor volumes (BTVs), defined by the uptake of (18)F fluoroethyltyrosine (FET) for the radiotherapy planning of high-grade glioma, using a dedicated positron emission tomography (PET)-CT scanner equipped with three triangulation lasers for patient positioning. METHODS: Nineteen patients with malignant glioma were included into a prospective protocol using FET PET-CT for radiotherapy planning. To be eligible, patients had to present with residual disease after surgery. Planning was performed using the clinical target volume (CTV = GTV union or logical sum BTV) and planning target volume (PTV = CTV + 20 mm). First, the interrater reliability for BTV delineation was assessed among three observers. Second, the BTV and GTV were quantified and compared. Finally, the geometrical relationships between GTV and BTV were assessed. RESULTS: Interrater agreement for BTV delineation was excellent (intraclass correlation coefficient 0.9). Although, BTVs and GTVs were not significantly different (p = 0.9), CTVs (mean 57.8 +/- 30.4 cm(3)) were significantly larger than BTVs (mean 42.1 +/- 24.4 cm(3); p < 0.01) or GTVs (mean 38.7 +/- 25.7 cm(3); p < 0.01). In 13 (68%) and 6 (32%) of 19 patients, FET uptake extended >or= 10 and 20 mm from the margin of the gadolinium enhancement. CONCLUSION: Using FET, the interrater reliability had excellent agreement for BTV delineation. With FET PET-CT planning, the size and geometrical location of GTVs and BTVs differed in a majority of patients.
Resumo:
Purpose: We intended to determine whether the need for retreatmentwith intravitreal ranibizumab follows an individual rhythm in patientswith exudative AMD. Setting: Prospective mono-centre cohort study.Methods: Prospective study. 48 patients with exudative AMD. 3 loadingdoses of ranibizumab, followed by a 12 months PRN regimen guided byearly exudative signs on SD-OCT. An intensified follow-up allowed todetect recurrences early.Results:Mean VA improved by 6.4 letters at month 3 and by 13.1 letters atmonth 12, with a mean of 8.0 injections (range 0-12) during the maintenancephase. The intra-individual variance of the intervals was relativelysmall and ranged within 20% of themean interval in 91% of patients.Thefirst interval was within 1 week of the mean interval in 84% of patients.The retreatment criteria were stable in 89% of patients.Conclusion: The relative stability of the intra-individual intervalsmay allowsimplifying the care for AMDpatients.Theremay be a predictive role for thefirst interval after the loading phase. The functional results of this PRNregimenwith early retreatmentwere excellent. Financial disclosure:None.
Resumo:
Image registration has been proposed as an automatic method for recovering cardiac displacement fields from Tagged Magnetic Resonance Imaging (tMRI) sequences. Initially performed as a set of pairwise registrations, these techniques have evolved to the use of 3D+t deformation models, requiring metrics of joint image alignment (JA). However, only linear combinations of cost functions defined with respect to the first frame have been used. In this paper, we have applied k-Nearest Neighbors Graphs (kNNG) estimators of the -entropy (H ) to measure the joint similarity between frames, and to combine the information provided by different cardiac views in an unified metric. Experiments performed on six subjects showed a significantly higher accuracy (p < 0.05) with respect to a standard pairwise alignment (PA) approach in terms of mean positional error and variance with respect to manually placed landmarks. The developed method was used to study strains in patients with myocardial infarction, showing a consistency between strain, infarction location, and coronary occlusion. This paper also presentsan interesting clinical application of graph-based metric estimators, showing their value for solving practical problems found in medical imaging.
Resumo:
Ophthalmologists typically acquire different image modalities to diagnose eye pathologies. They comprise, e.g., Fundus photography, optical coherence tomography, computed tomography, and magnetic resonance imaging (MRI). Yet, these images are often complementary and do express the same pathologies in a different way. Some pathologies are only visible in a particular modality. Thus, it is beneficial for the ophthalmologist to have these modalities fused into a single patient-specific model. The goal of this paper is a fusion of Fundus photography with segmented MRI volumes. This adds information to MRI that was not visible before like vessels and the macula. This paper contributions include automatic detection of the optic disc, the fovea, the optic axis, and an automatic segmentation of the vitreous humor of the eye.
Resumo:
My case study of "Caroline"-a 26 year old presenting with depression, PTSD symptoms, and a history of sexual abuse as a teenager-represents a "third way" between (1) a strict adherence to a manualized treatment, and (2) a principle-guided therapy, in which the therapy follows particular theoretical concepts, but depends on the therapist's clinical judgement to flexibly apply them to the individual case. Specifically, in my therapy with Caroline (Kramer, 2009), I employed Foa and Rothbaum's (1998) cognitive-behavioral, "Prolonged Exposure" (PE) manual for PTSD, but deviated from it in certain ways based upon my evaluation of Caroline's individualized goals and reactions using Grawe and Caspar's "Plan Analysis," which is a cross-theoretical model for assessment and treatment planning. In their commentaries on my case study of Caroline, Caspar (2009) and Haldimann-Balli (see Appendix in Kramer, 2009) support my use of this third way. On the other hand, the other commentators-Muller (2009) and Hembree and Brinen (2009)-critique my handling of the case, arguing that strict adherence to the Foa and Rothbaum manual would have resulted in a more cost-effective therapy. In this article, I respond to the important issues raised by the four commentators.
Resumo:
OBJECTIVES: To assess inter-observer variability of renal blood oxygenation level-dependent MRI (BOLD-MRI) using a new method of analysis, called the concentric objects (CO) technique, in comparison with the classical ROI (region of interest)-based technique. METHODS: MR imaging (3T) was performed before and after furosemide in 10 chronic kidney disease (CKD) patients (mean eGFR 43±24ml/min/1.73m(2)) and 10 healthy volunteers (eGFR 101±28ml/min1.73m(2)), and R2* maps were determined on four coronal slices. In the CO-technique, R2* values were based on a semi-automatic procedure that divided each kidney in six equal layers, whereas in the ROI-technique, all circles (ROIs) were placed manually in the cortex and medulla. The mean R2*values as assessed by two independent investigators were compared. RESULTS: With the CO-technique, inter-observer variability was 0.7%-1.9% across all layers in non-CKD, versus 1.6%-3.8% in CKD. With the ROI-technique, median variability for cortical and medullary R2* values was 3.6 and 6.8% in non-CKD, versus 4.7 and 12.5% in CKD; similar results were observed after furosemide. CONCLUSION: The CO-technique offers a new, investigator-independent, highly reproducible alternative to the ROI-based technique to estimate renal tissue oxygenation in CKD.