977 resultados para MEAN MAGNETIC-FIELD


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method is presented for the systematic design of asymmetric zonal shim coils for magnetic resonance applications. Fourier-series methods are used to represent the magnetic field inside and outside a circular cylinder of length 2L and radius a. The current density on the cylinder is also represented using Fourier series. Any desired field can be specified in advance on the cylinder's radius, over some nonsymmetric portion pL

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

For ground penetrating radar (GPR), smaller antennas would provide considerable practical advantages. Some of which are: portability; ease of use; and higher spatial sampling. A theoretical comparison of the fundamental limits of a small electric field antenna and a small magnetic field antenna shows that the minimum Q constraints are identical. Furthermore, it is shown that only the small magnetic loop antenna can be constructed to approach, arbitrarily closely, the fundamental minimum Q limit. This is achieved with the addition of a high permeability material which reduces energy stored in the magnetic fields. This is of special interest to some GPR applications. For example, applications requiring synthetic aperture data collection would benefit from the increased spatial sampling offered by electrically smaller antennas. Low frequency applications may also benefit, in terms of reduced antenna dimensions, by the use of electrically small antennas. Under these circumstances, a magnetic type antenna should be considered in preference to the typical electric field antenna. Numerical modeling data supports this assertion.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength. (C) 2003 Elsevier Science (USA). All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The equipment used to measure magnetic fields and, electric currents in residences is described. The instrumentation consisted of current transformers, magnetic field probes and locally designed and, built signal conditioning modules. The data acquisition system was capable of unattended recording for extended time periods. The complete system was calibrated to verify its response to known physical inputs. (C) 2003 ISA-The Instrumentation Automation Society.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Esta tese tem por objectivo o desenho e avaliação de um sistema de contagem e classificação de veículos automóveis em tempo-real e sem fios. Pretende, também, ser uma alternativa aos actuais equipamentos, muito intrusivos nas vias rodoviárias. Esta tese inclui um estudo sobre as comunicações sem fios adequadas a uma rede de equipamentos sensores rodoviários, um estudo sobre a utilização do campo magnético como meio físico de detecção e contagem de veículos e um estudo sobre a autonomia energética dos equipamentos inseridos na via, com recurso, entre outros, à energia solar. O projecto realizado no âmbito desta tese incorpora, entre outros, a digitalização em tempo real da assinatura magnética deixada pela passagem de um veículo, no campo magnético da Terra, o respectivo envio para servidor via rádio e WAN, Wide Area Network, e o desenvolvimento de software tendo por base a pilha de protocolos ZigBee. Foram desenvolvidas aplicações para o equipamento sensor, para o coordenador, para o painel de controlo e para a biblioteca de Interface de um futuro servidor aplicacional. O software desenvolvido para o equipamento sensor incorpora ciclos de detecção e digitalização, com pausas de adormecimento de baixo consumo, e a activação das comunicações rádio durante a fase de envio, assegurando assim uma estratégia de poupança energética. Os resultados obtidos confirmam a viabilidade desta tecnologia para a detecção e contagem de veículos, assim como para a captura de assinatura usando magnetoresistências. Permitiram ainda verificar o alcance das comunicações sem fios com equipamento sensor embebido no asfalto e confirmar o modelo de cálculo da superfície do painel solar bem como o modelo de consumo energético do equipamento sensor.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present a palaeomagnetic study on 38 lava flows and 20 dykes encompassing the past 1.3 Myr on S. Jorge Island (Azores ArchipelagoNorth Atlantic Ocean). The sections sampled in the southeastern and central/western parts of the island record reversed and normal polarities, respectively. They indicate a mean palaeomagnetic pole (81.3 degrees N, 160.7 degrees E, K= 33 and A95= 3.4 degrees) with a latitude shallower than that expected from Geocentric Axial Dipole assumption, suggesting an effect of non-dipolar components of the Earth magnetic field. Virtual Geomagnetic Poles of eight flows and two dykes closely follow the contemporaneous records of the Cobb Mountain Subchron (ODP/DSDP programs) and constrain the age transition from reversed to normal polarity at ca. 1.207 +/- 0.017 Ma. Volcano flank instabilities, probably related to dyke emplacement along an NNWSSE direction, led to southwestward tilting of the lava pile towards the sea. Two spatially and temporally distinct dyke systems have been recognized on the island. The eastern is dominated by NNWSSE trending dykes emplaced before the end of the Matuyama Chron, whereas in the central/western parts the eruptive fissures oriented WNWESE controlled the westward growth of the S. Jorge Island during the Brunhes Chron. Both directions are consistent with the present-day regional stress conditions deduced from plate kinematics and tectonomorphology and suggest the emplacement of dykes along pre-existing fractures. The distinct timing and location of each dyke system likely results from a slight shift of the magmatic source.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conferência: 9th International Symposium on Occupational Safety and Hygiene (SHO) Guimaraes, Portugal - FEB 14-15, 2013

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The erosion depth profile of planar targets in balanced and unbalanced magnetron cathodes with cylindrical symmetry is measured along the target radius. The magnetic fields have rotational symmetry. The horizontal and vertical components of the magnetic field B are measured at points above the cathode target with z = 2 x 10(-3) m. The experimental data reveal that the target erosion depth profile is a function of the angle. made by B with a horizontal line defined by z = 2 x 10(-3) m. To explain this dependence a simplified model of the discharge is developed. In the scope of the model, the pathway lengths of the secondary electrons in the pre-sheath region are calculated by analytical integration of the Lorentz differential equations. Weighting these lengths by using the distribution law of the mean free path of the secondary electrons, we estimate the densities of the ionizing events over the cathode and the relative flux of the sputtered atoms. The expression so deduced correlates for the first time the erosion depth profile of the target with the angle theta. The model shows reasonably good fittings to the experimental target erosion depth profiles confirming that ionization occurs mainly in the pre-sheath zone.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present a palaeomagnetic study on 38 lava flows and 20 dykes encompassing the past 1.3 Myr on S. Jorge Island (Azores ArchipelagoNorth Atlantic Ocean). The sections sampled in the southeastern and central/western parts of the island record reversed and normal polarities, respectively. They indicate a mean palaeomagnetic pole (81.3 degrees N, 160.7 degrees E, K= 33 and A95= 3.4 degrees) with a latitude shallower than that expected from Geocentric Axial Dipole assumption, suggesting an effect of non-dipolar components of the Earth magnetic field. Virtual Geomagnetic Poles of eight flows and two dykes closely follow the contemporaneous records of the Cobb Mountain Subchron (ODP/DSDP programs) and constrain the age transition from reversed to normal polarity at ca. 1.207 +/- 0.017 Ma. Volcano flank instabilities, probably related to dyke emplacement along an NNWSSE direction, led to southwestward tilting of the lava pile towards the sea. Two spatially and temporally distinct dyke systems have been recognized on the island. The eastern is dominated by NNWSSE trending dykes emplaced before the end of the Matuyama Chron, whereas in the central/western parts the eruptive fissures oriented WNWESE controlled the westward growth of the S. Jorge Island during the Brunhes Chron. Both directions are consistent with the present-day regional stress conditions deduced from plate kinematics and tectonomorphology and suggest the emplacement of dykes along pre-existing fractures. The distinct timing and location of each dyke system likely results from a slight shift of the magmatic source.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We investigate the structural chain-to-ring transition at low temperature in a gas of dipolar hard spheres (DRS). Due to the weakening of entropic contribution, ring formation becomes noticeable when the effective dipole-dipole magnetic interaction increases, It results in the redistribution of particles from usually observed flexible chains into flexible rings. The concentration (rho) of DI-IS plays a crucial part in this transition: at a very low rho only chains and rings are observed, whereas even a slight increase of the volume fraction leads to the formation of branched or defect structures. As a result, the fraction of DHS aggregated in defect-free rings turns out to be a non-monotonic function of rho. The average ring size is found to be a slower increasing function of rho when compared Lo that of chains. Both theory and computer simulations confirm the dramatic influence of the ring formation on the rho-dependence of the initial magnetic susceptibility (chi) when the temperature decreases. The rings clue to their zero total dipole moment are irresponsive to a weak magnetic field and drive to the strong decrease of the initial magnetic susceptibility. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A Salmonella é um microrganismo responsável por grande parte das doenças alimentares, podendo por em causa a saúde pública da área contaminada. Uma deteção rápida, eficiente e altamente sensível e extremamente importante, sendo um campo em franco desenvolvimento e alvo de variados e múltiplos estudos na comunidade cientifica atual. Foi desenvolvido um método potenciométrico para a deteção de Salmonellas, com elétrodos seletivos de iões, construídos em laboratório com pontas de micropipetas, fios de prata e sensores com composição otimizada. O elétrodo indicador escolhido foi um ESI seletivo a cadmio, para redução da probabilidade de interferências no método, devido a pouca abundancia do cadmio em amostras alimentares. Elétrodos seletivos a sódio, elétrodos de Ag/AgCl de simples e de dupla juncão foram também construídos e caracterizados para serem aplicados como elétrodos de referência. Adicionalmente otimizaram-se as condições operacionais para a analise potenciométrica, nomeadamente o elétrodo de referencia utilizado, condicionamento dos elétrodos, efeito do pH e volume da solução amostra. A capacidade de realizar leituras em volumes muito pequenos com limites de deteção na ordem dos micromolares por parte dos ESI de membrana polimérica, foi integrada num ensaio com um formato nao competitivo ELISA tipo sanduiche, utilizando um anticorpo primário ligado a nanopartículas de Fe@Au, permitindo a separação dos complexos anticorpo-antigénio formados dos restantes componentes em cada etapa do ensaio, pela simples aplicação de um campo magnético. O anticorpo secundário foi marcado com nanocristais de CdS, que são bastante estáveis e é fácil a transformação em Cd2+ livre, permitindo a leitura potenciométrica. Foram testadas várias concentrações de peroxido de hidrogénio e o efeito da luz para otimizar a dissolução de CdS. O método desenvolvido permitiu traçar curvas de calibração com soluções de Salmonellas incubadas em PBS (pH 4,4) em que o limite de deteção foi de 1100 CFU/mL e de 20 CFU/mL, utilizando volumes de amostra de 10 ƒÊL e 100 ƒÊL, respetivamente para o intervalo de linearidade de 10 a 108 CFU/mL. O método foi aplicado a uma amostra de leite bovino. A taxa de recuperação media obtida foi de 93,7% } 2,8 (media } desvio padrão), tendo em conta dois ensaios de recuperação efetuados (com duas replicas cada), utilizando um volume de amostra de 100 ƒÊL e concentrações de 100 e 1000 CFU/mL de Salmonella incubada.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cancer is a well-known disease with a significant impact in society not only due to its incidence, more evident in more developed countries, but also due to the expenses related to medical treat-ments. Cancer research is considered an increasingly logical science with great potential for the development of new treatment options. Advances in nanomedicine have resulted in rapid devel-opment of nanomaterials with considerable potential in cancer diagnostics and treatment. The combination of diagnosis and treatment in a single nano-platform is named theranostic. In this PhD thesis a theranostic system for osteosarcoma was proposed, composed by a magnetic core, a polymeric coating, and a chemotherapeutic drug. The presence of a specific targeting agent, in this case a monoclonal antibody, provides high specificity to the proposed theranostic system. For the core of the proposed theranostic system, stable aqueous suspensions of superparamagnetic iron oxide nanoparticles with an average diameter of 9 nm were produced. Chitosan-based poly-meric nanoparticles with a hydrodynamic diameter around 150 nm were successfully produced. Incorporation of iron oxide nanoparticles into the polymeric ones increased their hydrodynamic diameter to at least 250 nm. A monoclonal antibody specific for a transmembranar protein (car-bonic anhydrase IX) present in solid tumors was developed by hybridoma technology. Functional hybridomas producing the desired monoclonal antibodies were obtained. The proposed theranostic system functionality was evaluated in separated parts of its components. Uncoated and coated iron oxide nanoparticles with chitosan-based polymers generated heat under the application of an external alternating magnetic field. Uncoated iron oxide nanoparticles sta-bilized with oleic acid were able to enhance contrast in magnetic resonance imaging. Drug deliv-ery studies were conducted in chitosan-based polymeric nanoparticles without and with the in-corporation of iron oxide nanoparticles, demonstrating to be an effective drug delivery platform for doxorubicin. The theranostic system proposed in this PhD thesis is very promising for cancer theranostic, demonstrating to be applicable in solid tumors such as osteosarcoma.