845 resultados para Load bearing system


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper an alternative method based on artificial neural networks is presented to determine harmonic components in the load current of a single-phase electric power system with nonlinear loads, whose parameters can vary so much in reason of the loads characteristic behaviors as because of the human intervention. The first six components in the load current are determined using the information contained in the time-varying waveforms. The effectiveness of this method is verified by using it in a single-phase active power filter with selective compensation of the current drained by an AC controller. The proposed method is compared with the fast Fourier transform.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

During the construction of five residential buildings in the city of Taubate, State of São Paulo, it was possible to carry out one comprehensive investigation of the behavior of precast concrete piles in clay shales. This paper describes the results of Dynamic Load Tests (DLT's) executed in three piles with different diameters and with the same embedded length. The tests were monitored using the PDA(R) (Pile Driving Analyzer) and the pile top displacement was measured by pencil and paper procedure. From the curves of RMX versus DMX resulted from CASE(R) method, CAPWAPC(R) analyses were made for signals where the maximum mobilized soil resistance was verified. The results were compared with the predicted bearing capacity using the semi-empirical method of Decourt & Quaresma (1978) and Decourt (1982) based on SPT values and the description of the soil profile. Some comments related to the values of quake and damping used for clay shales in the analyses are also presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The stabilization of swine wastewaters from swine confined housing by the combination of a upflow anaerobic sludge blanket (UASB) reactor and waste stabilization ponds is a viable alternative to minimize the environmental impact caused by inadequate disposal of swine wastewaters. In the present study, the polluting load of pre-decanted swine wastewater treated with a series of two 0.705 m(3) UASB reactors and then in parallel in aerated and non-aerated stabilization tanks was investigated from January to July, 2000. Physicochemical and microbiological analyses were made adopting standard methods (Standard Methods for Examination of Water and Wastewater, 19th ed., American Public Health Association, Washington, DC, 1995). COD values decreased as the wastewater ran through the integrated biodigestion system dropping from about 3492 +/- 511-4094 mg l(-1) +/- 481 to 124 +/- 52-490 mg l(-1) +/- 230, while nitrate and nitrite levels increased in stabilization tanks, ranging respectively from 4 +/- 0 to 20 mg l(-1) +/- 3 and 3 +/- 1 to 11 mg l(-1) +/- 24. Although the removal of Escherichia coli was more than 97% +/- 6, the effluents of the treatment system still contained unacceptable levels of E. coli (1.6 x 10(3)-1.2 x 10(6) 100 ml(-1)) according to WHO guidelines for use of wastewater in agriculture and aquaculture. These results indicate the necessity of changes on operational characteristics of the treatment system such as an increase of the hydraulic retention time in UASB reactors or in stabilization tanks. (C) 2003 Published by Elsevier Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The relationship between normal and tangential force components (grip force - GF and load force - LF, respectively) acting on the digits-object interface during object manipulation reveals neural mechanisms involved in movement control. Here, we examined whether the feedback type provided to the participants during exertion of LF would influence GF-LF coordination and task performance. Methods. Sixteen young (24.7 ±3.8 years-old) volunteers isometrically exerted continuously sinusoidal FZ (vertical component of LF) by pulling a fixed instrumented handle up and relaxing under two feedback conditions: targeting and tracking. In targeting condition, FZ exertion range was determined by horizontal lines representing the upper (10 N) and lower (1 N) targets, with frequency (0.77 or 1.53 Hz) dictated by a metronome. In tracking condition, a sinusoidal template set at similar frequencies and range was presented and should be superposed by the participants' exerted FZ. Task performance was assessed by absolute errors at peaks (AEPeak) and valleys (AEValley) and GF-LF coordination by GF-LF ratios, maximum cross-correlation coefficients (r max), and time lags. Results: The results revealed no effect of feedback and no feedback by frequency interaction on any variable. AE Peak and GF-LF ratio were higher and rmax lower at 1.53 Hz than at 0.77 Hz. Conclusion: These findings indicate that the type of feedback does not influence task performance and GF-LF coordination. Therefore, we recommend the use of tracking tasks when assessing GF-LF coordination during isometric LF exertion in externally fixed instrumented handles because they are easier to understand and provide additional indices (e.g., RMSE) of voluntary force control. © 2013 Pedão et al.; licensee BioMed Central Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Chair of Transportation and Ware-housing at the University of Dortmund together with its industrial partner has developed and implemented a decentralized control system based on embedded technology and Internet standards. This innovative, highly flexible system uses autonomous software modules to control the flow of unit loads in real-time. The system is integrated into Chair’s test facility consisting of a wide range of conveying and sorting equipment. It is built for proof of concept purposes and will be used for further research in the fields of decentralized automation and embedded controls. This presentation describes the implementation of this decentralized control system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A distributed power architecture for aerospace application with very restrictive specifications is analyzed. Parameters as volume, weight and losses are analyzed for the considered power architectures. In order to protect the 3 phase generator against high load steps, an intermediate bus (based in a high capacitance) to provide energy to the loads during the high load steps is included. Prototypes of the selected architecture for the rectifier and EMI filter are built and the energy control is validated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main purpose of this paper was to find a simple solution for load balancing and fault tolerance in OSGi. The challenge was to implement a highly available web application such as a shopping cart system with load balancing and fault tolerance, without having to change the core of OSGi.

Relevância:

30.00% 30.00%

Publicador: