998 resultados para Laser Propagation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hyphenated instrumental approach has been used to obtain reliable values for the propagation rate coefficients as a function of conversion for polymerizations of methyl methacrylate (MMA) and a mixture of MMA and ethyleneglycol dimethacrylate (EGDMA) with a 1:1 concentration of double bonds, from near the onset of the Trommsdorf region into the glass region. ESR spectroscopy was used to measure the radical concentration while FT-NIR fibre-optic spectroscopy was employed to measure instantaneously the double-bond concentration within the temperature-controlled cavity of the ESR instrument during polymerization. The advantage of this approach to the measurement of the rate coefficient is that it is equally applicable to branching and linear polymerizations. For the polymerization of methyl methacrylate, the values of the rate coefficient at the lowest conversions at which reliable values could be obtained were in agreement with recently reported values obtained by the PLP-SEC method. For the lowest conversions, the values obtained were 403 1 mol(-1) s(-1) at 306 K for MMA and 5201 mol(-1) s(-1) at 310 K for a 1:1 mixture of MMA and EGDMA. (C) 2003 Society of Chemical Industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump pump, Stokes signal, and Raman coherence idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Onicomicose é a doença ungueal mais frequente, com prevalência estimada entre 2 e 8% da população. As estratégias de tratamentos atuais incluem uso de antifúngicos tópicos e orais, ambos geralmente com baixos índices de cura. Os objetivos deste estudo foram avaliar a resposta terapêutica ao laser Nd:YAG 1.064 nm no tratamento da onicomicose, bem como o método de avaliação clínica dessa terapia e os possíveis efeitos colaterais de seu uso. Foram revisados prontuários de 20 pacientes submetidos à laserterapia. Ao todo, 34 unhas afetadas foram avaliadas de acordo com o Índice de Severidade de Onicomicose (ISO). Esse índice analisa a área de envolvimento da unha, a proximidade da doença com a matriz ungueal, a ocorrência de dermatofitoma e a presença de hiperqueratose subungueal > 2 mm, gerando uma pontuação que classifica a onicomicose como leve, moderada ou grave. A determinação do ISO foi realizada antes do tratamento e após um período de acompanhamento, em média, de oito meses. A comparação entre o ISO Inicial e o ISO Final nas 34 unhas submetidas à laserterapia mostrou diferença significativa, porém, com baixa associação entre essas variáveis. Com relação à área de envolvimento e à pontuação numérica referente ao ISO, houve, no geral, uma redução dessas medidas. Esses dados apontam para uma tendência à melhora da onicomicose por meio do tratamento com o laser Nd:YAG 1.064 nm. O ISO permitiu uma análise clínica adequada da resposta à laserterapia. Os efeitos colaterais locais apresentados durante a aplicação do laser não causaram desconforto acentuado na maioria dos pacientes, demonstrando que o procedimento é bem tolerado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a voz de pacientes portadores de carcinomas iniciais glóticos submetidos à cordectomia com laser de CO2. MÉTODO: Foram avaliados 15 pacientes com diagnóstico de carcinoma espinocelular Tis e T1 glóticos. A avaliação foi feita por meio da análise perceptivo auditiva da voz, pela análise acústica computadorizada e videolaringoestroboscópica. Os pacientes responderam a um questionário de avaliação geral da voz e um protocolo de qualidade de vida relacionado à voz (QVV). Os resultados foram comparados aos de um grupo controle de indivíduos com laringes normais. RESULTADOS: A análise perceptivo-auditiva da voz revelou que a maioria dos pacientes submetidos à cordectomia apresentou algum grau de disfonia, à custa de rouquidão e soprosidade. Considerando os parâmetros acústicos analisados e os valores do grupo controle, observou-se a tendência de um pequeno incremento da freqüência fundamental, mas sem diferença estatisticamente significante; os valores de jitter, shimmer e da proporção harmônico-ruído apresentaram-se significantemente alterados. Os aspectos analisados na videolaringoestroboscopia mostraram-se melhores nas cordectomias menos extensas. Os escores do QVV sugerem que os pacientes tiveram um discreto impacto na qualidade de vida relacionada à voz. CONCLUSÕES: Apesar da presença de alterações na qualidade vocal dos pacientes submetidos à cordectomia com laser de CO2, os resultados funcionais tendem a ser bem aceitos pelos pacientes, com discreta repercussão na qualidade de vida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Otite média secretora (OMS) e otite média aguda recorrente (OMAR) podem necessitar tratamento cirúrgico para adequada ventilação da orelha média. A abertura clássica do tímpano (timpanocentese) requer incisão por microlanceta sob controle de microscópio cirúrgico e mantém-se patente por alguns dias. Estudos recentes sugerem que a timpanocentese feita por diferentes lasers pode permanecer permeável por maior tempo, o que possibilitaria a normalização da otite média. MATERIAL E MÉTODOS: Neste estudo experimental 34 ratos linhagem Wistar, albinos, machos adultos pesando cerca de 300g, foram anestesiados com cetamina 27 mg/kg e xilazina 2,7 mg/kg. A seguir, foram submetidos à timpanocentese incisional com microlanceta no ouvido direito (ML-OD), e à timpanocentese mediada por laser de argônio no ouvido esquerdo (LA-OE). RESULTADOS: Não houve diferença significativa no tempo de cicatrização das timpanocenteses feitas com laser de argônio ou microlanceta. Todas as timpanocenteses cicatrizaram em 10 dias. CONCLUSÃO: A timpanocentese com laser de argônio apresentou patência e cicatrização semelhantes à técnica clássica com microlanceta realizada em ratos Wistar sem enfermidades de orelha média.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vegetative propagation of lavender offers several advantages over sexual propagation, among them crop homogeneity and yield of higher quality essential oil. However, Lavandula species have been propagated mostly by seeds and are said to be recalcitrant to rooting when propagated by cuttings. During cutting propagation, one of the important variables that influence the rooting capacity of cuttings is the leaf retention. The objective of this work was to evaluate the influence of leaf retention on rooting of L. dentata cuttings. Apical cuttings of L. dentata of 10 cm in length, keeping approximately 1/3, 1/2 or 2/3 of their leaves were planted in commercial substrate Plantmax HT® under intermittent mist. After two months, averages of root number, length of the longest root, root fresh and dry weights, and the survival percentage were evaluated. Root length and fresh weight were statistically greater with 2/3 of leaf retention and when fewer leaves were kept on the cuttings, lower means of root dry weight was observed. Under the conditions applied in this study, greater leaf retention was better for rooting of L. dentata cuttings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a great demand for simpler and less costly laboratory techniques and for more accessible procedures for orchid breeders who do not have the necessary theoretical basis to use the traditional seed and clone production methods of orchids in vitro. The aim of this study was to assess the use of sodium hypochlorite (NaClO) as a decontaminant in the process of inoculating adult orchid explants of Arundina bambusifolia and Epidendrum ibaguenses. Solutions of NaClO (1.200, 2.400, 3.600, 4.800 and 6.000 mg L-1 - equivalent to 50, 100, 150, 200 and 250 mL L-1 of commercial bleach - CB) were sprayed on the explants (1.0 mL) and the culture medium (GB5), in the presence or absence of activated charcoal (2 g L-1). The explants used were nodal segments of field-grown adult plants. The procedures for inoculating the explants were conducted outside the laminar flow chamber (LFC), except for the control treatment (autoclaved medium and explant inoculation inside the LFC). The best results for fresh weight yield, height and number of shoots were obtained using NaClO in solution at 1.200 mg L-1 (equivalent to 50 mL L-1 commercial bleach) with activated charcoal in the culture medium. Fresh weight figures were 1.10 g/jar for Arundina bambusifolia and 0.16 g/jar for Epidendrum ibaguenses. Spraying the NaClO solutions controls the contamination of the culture medium already inoculated with the explants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax and usually comprises Computed Tomography (CT) examination for pre-operative diagnosis. Aiming at the elimination of the high amounts of CT radiation exposure, this work presents a new methodology for the replacement of CT by a laser scanner (radiation-free) in the treatment of pectus excavatum using personally modeled prosthesis. The complete elimination of CT involves the determination of ribs external outline, at the maximum sternum depression point for prosthesis placement, based on chest wall skin surface information, acquired by a laser scanner. The developed solution resorts to artificial neural networks trained with data vectors from 165 patients. Scaled Conjugate Gradient, Levenberg-Marquardt, Resilient Back propagation and One Step Secant gradient learning algorithms were used. The training procedure was performed using the soft tissue thicknesses, determined using image processing techniques that automatically segment the skin and rib cage. The developed solution was then used to determine the ribs outline in data from 20 patient scanners. Tests revealed that ribs position can be estimated with an average error of about 6.82±5.7 mm for the left and right side of the patient. Such an error range is well below current prosthesis manual modeling (11.7±4.01 mm) even without CT imagiology, indicating a considerable step forward towards CT replacement by a 3D scanner for prosthesis personalization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the substrate, cuttings collection time, the position and the cutting depth, and the propagation environment on rooting of 'Purple Valinhos' fig tree cuttings in Southwestern Paraná, Brazil. Two experiments were carried out at UTFPR, Câmpus Dois Vizinhos, with hardwoods cuttings from Roxo de Valinhos fig tree. The first experiment used a randomized block design, in 3 x 3 x 2 factorial (substrate x environment x collection time), with four replications of 10 cuttings per plot. The cuttings were collected in the first fifteen days of July and August. The substrates were sand, soil and the mixture of these [1:1 (v / v)]. The environments used were open sky, tunnel with plastic cover and tunnel with half-shade black net cover. The second experiment used a randomized block design, 2 x 2 x 3 factorial (shoot cutting position x soil cover x shoot cutting depth), with four replications of 12 cuttings per plot. In the factor position, the vertically (0 º inclination) and inclined (45 º inclination) shoot cuttings were evaluated. Soil cover was tested with mulching plastic cover or not. The tested depths were 1/3, 1/2 and 2/3 in relation to the total length of the shoot cutting. In both experiments, the following were analyzed: rooting and mortality indices, number of leaves and primary shoots, length of the three largest roots per cutting. It was conclude that, the protected environment with plastic cover on sand as substrate must recommended for the rooting of fig estaca, collecting them in the first half of July. The inclination position and cutting depth of the estaca and the substrate coverage with plastic mulching did not influence the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wettability of polyimide surfaces microstructured using KrF laser radiation at fluences above the material ablation threshold was studied by static contact angle measurements. The laser-treated surfaces present a morphology consisting of conical features whose dimensions and areal density depend on the fluence. The effect of these parameters on the surface apparent contact angle depends on the wetting regime. When wetting occurs in the homogeneous regime, the apparent contact angle of the treated surfaces increases with the radiation fluence because the cone dimensions increase. In contrast, when wetting occurs in the heterogeneous regime, the apparent contact angle increases with the radiation fluence because the average distance between cones increases. The apparent water contact angle of the laser-treated surfaces can reach values as high as 162 degrees, as compared to 75 degrees for virgin polyimide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evolution of the topography of titanium surfaces treated with femtosecond laser radiation in stationary conditions as a function of radiation fluence and number of laser pulses is investigated. Depending on the processing parameters, ripples, microcolumns, wavy or smooth surfaces can be obtained. The ripples predominate for fluences near the damage threshold of titanium (0.2+/-0.1) J/cm(2), while microcolumns form during the first 200 pulses for fluences between (0.6+/-0.2) and (1.7+/-0.2) J/cm(2). A wavy topography develops for fluences and number of pulses higher than (1.7+/-0.2) J/cm(2) and 300, respectively. A bimodal surface topography consisting of surface ripples overlapping a microcolumnar topography can be obtained if the surfaces are firstly treated to create microcolumns followed by laser treatment with a lower fluence near the ablation threshold of the material, in order to generate periodic ripple

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta dissertação surgiu com o objectivo de se criar uma base de dados de Toners para impressoras e fotocopiadoras e um método fiável de comparação de espectros para estudos forenses e de investigação criminal. Para viabilizar o estudo, efectuou-se à priori a recolha de várias amostras de Toners, de diferentes marcas, de cartuchos originais e remanufacturados aplicando de seguida dois métodos de análise distintos: a Espectroscopia de infravermelho com transformada de Fourier (FT-IR) e a Espectroscopia de Absorção-Reflexão (ATR - Reflectância total atenuada). A espectroscopia FT-IR permitiu obter a base de dados de espectros em suporte KBr e usando o software OPUS, das várias amostras de Toners dos cartuchos originais e remanufacturados recolhidas. Para se criar o método de comparação entre espectros, realizou-se o mesmo procedimento mas agora para amostras obtidas por raspagem de um papel impresso /quadrados 2x2), bem como para o papel de impressão para se poder descontar este da amostra. Dado que o interesse desta análise se remetia ao estudo de textos escritos, efectuou-se a análise de um texto padrão por Espectroscopia FT-IR. O método foi utilizado à posteriori como método de comparação e uma alternativa (não destrutiva) ao método de FT-IR para se aplicar a casos reais. Os espectros foram obtidos num microscópio usando o silício como acessório ATR e o software OMNIC. Finalizado o estudo pode-se concluir, quanto à espectroscopia FT-IR, que as amostras da marca HP e Minolta apresentaram espectros muito semelhantes, quando se faz uma análise global dos mesmos. No entanto, as restantes marcas são também muito parecidas entre si, mas ainda é possível encontrar algumas distinções quando se efectua a comparação visual principalmente abaixo da zona de impressão digital (<6000 cm-1). Relativamente aos Toners remanufacturados, constata-se que são muito semelhantes e que diferem da marca original apenas pelo elevado grau de humidade que possuem. No que diz respeito ao método ATR, verificou-se que apesar de ser um método não destrutivo da amostra revela-se bastante limitado, devido ao uso do cristal de Silício como acessório que só atinge comprimentos de onda entre 4000-1500cm-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report in this paper the recent advances we obtained in optimizing a color image sensor based on the laser-scanned-photodiode (LSP) technique. A novel device structure based on a a-SiC:H/a-Si:H pin/pin tandem structure has been tested for a proper color separation process that takes advantage on the different filtering properties due to the different light penetration depth at different wavelengths a-SM and a-SiC:H. While the green and the red images give, in comparison with previous tested structures, a weak response, this structure shows a very good recognition of blue color under reverse bias, leaving a good margin for future device optimization in order to achieve a complete and satisfactory RGB image mapping. Experimental results about the spectral collection efficiency are presented and discussed from the point of view of the color sensor applications. The physics behind the device functioning is explained by recurring to a numerical simulation of the internal electrical configuration of the device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optimized ZnO:Al/a-pin SixCl1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed. The LSP utilizes light induced depletion layers as detector and a laser beam for readout. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Experimental data reveal that the large optical gap and the low conductivity of the doped a-SixC1-x:H layers are responsible by an induced inversion layer at the illuminated interfaces which blocks the carrier collection. These insulator-like layers act as MIS gates preventing image smearing. The physical background of the LSP is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optimized ZnO:Al/a-pin SixC1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed and the read-out parameters improved. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Data reveals that for sensors with wide band gap doped layers an increase on the image signal optimized to the blue is achieved with a dynamic range of two orders of magnitude, a responsivity of 6 mA W-1 and a sensitivity of 17 muW cm(-2) at 530 nm. The main output characteristics such as image responsivity, resolution, linearity and dynamic range were analyzed under reverse, forward and short circuit modes. The results show that the sensor performance can be optimized in short circuit mode. A trade-off between the scan time and the required resolution is needed since the spot size limits the resolution due to the cross-talk between dark and illuminated regions leading to blurring effects.