998 resultados para Implante de Prótese


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the biosecurity measures adopted in dental prosthesis laboratories of the city of João Pessoa, PB, Brazil with respect to prosthetic works sent by dentists. Method: Twenty-five dental prosthesis technicians (DPT) of the city of João Pessoa, PB, filled out a questionnaire referring to their knowledge of the biosecurity principles, disinfection of impressions and other prosthetic items, and the use of individual protection equipment (IPE). Results: Although 92% of the interviewees believed in the possible occurrence of cross-infection between dental prosthesis laboratories and dental offices, 64% declared that the prosthetic works received in their laboratories do not undergo any disinfection procedure. It was also observed that, for disinfection of impressions and stone casts, the chemical substances are not used as recommended by the manufacturers or are innocuous to microorganisms. Regarding the use of IPE, 60% of the DPT used mask, but only 4% used gowns. With respect to the measures taken regarding the impressions received from dental offices, 56% of the interviewees only wash them in running tap water, and 56% of the stone casts that arrive at the laboratory are not disinfected in any way. Conclusion: There is a need for more motivation and instructions to DPT regarding the prevention of cross-contamination during sending and receiving of prosthetic works between dental prosthesis laboratories and dental offices because the DPT evaluated in this study were found negligent with respect to disinfection procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the clinical application of implant of the canine cryopreserved amniotic membrane (DMEM plus DMSO 1:1) and 360° conjunctival flap in the treatment of progressive corneal ulceration. 10 dogs of the different breeds, males and females, aging four months to four years old with deep corneal ulceration and different clinical progression were divided in two groups: G1=360° conjunctival graft (n=5) and G2=implant of amniotic membrane, sutured at the edge of the ulcer with epithelial side facing up, associated with the third eyelid flap (n=5). The comparative analysis between groups was: complications, blepharospasm, ocular secretion, corneal vascularization, epithelial defect and corneal opacification in six moments (first emergency care, surgery and 3, 7, 15 and 30 days of postoperative). Without epithelial defect was evaluated quality of the scar. It was used score scale for subjective to qualify of the ocular signs. In G1, it was observed the non-adherence of the conjunctival graft to the ulcer (n=2), dehiscence of the suture (n=2), anterior synechia (n=2) and intense chemosis (n=1). In G2, it was not observed these complications. It was not significant difference between the groups to others ocular parameters, but it was different among the start and end moments of the same groups (ocular secretion, corneal vascularization, epithelial defect). The corneal opacity was more intense in G1. According to the clinical results, the cryopreserved amniotic membrane implant proved to be as effective in the corneal ulceration in comparison to the 360° conjunctival flap, because probably, the membrane promoted a trophic support for epithelialization, anti-inflamatory effect associated with important to the end result phenotype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)