938 resultados para INDOOR
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
The present work has aimed to determine the 16 US EPA priority PAH atmospheric particulate matter levels present in three sites around Salvador, Bahia: (i) Lapa bus station, strongly impacted by heavy-duty diesel vehicles; (ii) Aratu harbor, impacted by an intense movement of goods, and (iii) Bananeira village on Maré Island, a non vehicle-influenced site with activities such as handcraft work and fisheries. Results indicated that BbF (0.130-6.85 ng m-3) is the PAH with highest concentration in samples from Aratu harbor and Bananeira and CRY (0.075-6.85 ng m-3) presented higher concentrations at Lapa station. PAH sources from studied sites were mainly of anthropogenic origin such as gasoline-fueled light-duty vehicles and diesel-fueled heavy-duty vehicles, discharges in the port, diesel burning from ships, dust ressuspension, indoor soot from cooking, and coal and wood combustion for energy production.
Resumo:
Background: Environmental factors may influence the development of allergen sensitization and asthma. The aim of this study was to evaluate the role of endotoxin and allergen exposure in early life as a risk factor for recurrent wheezing. Methods: One hundred and four infants from low-income families, at high risk of asthma, were enrolled at birth. Dust samples were collected from the bedding and bedroom floor within 6 months after birth. Recurrent wheezing was defined as 3 or more wheezing episodes in the past year. Endotoxin was determined by Limulus amebocyte lysate assay, and major indoor allergens were quantitated by ELISA in dust extracts. IgE antibodies were measured by ImmunoCAP at 30 months of age. Results: At 30 months, 51 of the 99 infants who completed the study (51.5 per cent) had recurrent wheezing. Respiratory infection was strongly associated with recurrent wheezing (OR 6.67, 95 per cent CI 1.96-22.72), whereas exclusive breastfeeding for at least 1 month was a protective factor (OR 0.09, 95 per cent CI 0.01-0.51). Exposure to high levels of mouse allergen was more frequent among non-recurrent wheezers, approaching significance (OR 0.12, 95 per cent CI 0.01-1.13; p = 0.064). None of the children were sensitized to mouse. Sensitization to mite was found in 26/90 (28.8 per cent) children, with no association with recurrent wheezing. Conclusion: Respiratory infection was strongly associated with recurrent wheezing in the first 30 months of life, in children at high risk of asthma, living in a socially deprived community in Brazil
Resumo:
Abstract This paper aims at assessing the performance of a program of thermal simulation (Arquitrop) in different households in the city of Sao Paulo, Brazil. The households were selected for the Wheezing Project which followed up children under 2 years old to monitor the occurrence of respiratory diseases. The results show that in all three study households there is a good approximation between the observed and the simulated indoor temperatures. It was also observed a fairly consistent and realistic behavior between the simulated indoor and the outdoor temperatures, describing the Arquitrop model as an efficient estimator and good representative of the thermal behavior of households in the city of Sao Paulo. The worst simulation is linked to the poorest type of construction. This may be explained by the bad quality of the construction, which the Architrop could not simulate adequately
Resumo:
Background Studies have shown that there is no safe level of secondhand smoke (SHS) exposure and there is a close link between SHS and the risk of coronary heart disease and stroke. Carbon monoxide (CO) is one of the most important components present in SHS. Objective To evaluate the impact of the smoking ban law in the city of Sao Paulo, Brazil, on the CO concentration in restaurants, bars, night clubs and similar venues and in their workers. Methods In the present study we measured CO concentration in 585 hospitality venues. CO concentration was measured in different environments (indoor, semi-open and open areas) from visited venues, as well as, in the exhaled air from approximately 627 workers of such venues. Measurements were performed twice, before and 12 weeks after the law implementation. In addition, the quality of the air in the city during the same period of our study was verified. Results The CO concentration pre-ban and pot-ban in hospitality venues was indoor area 4.57 (3.70) ppm vs 1.35 (1.66) ppm (p<0.0001); semi-open 3.79 (2.49) ppm vs 1.16 (1.14) ppm (p<0.0001); open area 3.31 (2.2) ppm vs 1.31 (1.39) ppm (p<0.0001); smoking employees 15.78 (9.76) ppm vs 11.50 (7.53) ppm (p<0.0001) and non-smoking employees 6.88 (5.32) ppm vs 3.50 (2.21) ppm (p<0.0001). The average CO concentration measured in the city was lower than 1 ppm during both pre-ban and post-ban periods. Conclusion Sao Paulos smoking-free legislation reduced significantly the CO concentration in hospitality venues and in their workers, whether they smoke or not.
Resumo:
This study compared measurements of upper body aerobic fitness in elite (EC; n = 7) and intermediate rock climbers (IC; n = 7), and a control group (C; n = 7). Subjects underwent an upper limb incremental test on hand cycle ergometer, with increments of 23 W.min(-1), until exhaustion. Ventilation (VE) data were smoothed to 10 s averages and plotted against time for the visual determination of the first (VT1) and second (VT2) ventilatory thresholds. Peak power output was not different among groups [EC = 130.9 (+/- 11.8) W; IC = 122.1 (+/- 28.4) W; C = 115.4 (+/- 15.1) W], but time to exhaustion was significantly higher in EC than IC and C. VO(2PEAK) was significantly higher in EC [36.8 (+/- 5.7) mL.kg(-1).min(-1)] and IC [35.5 (+/- 5.2) mL.kg(-1).min(-1)] than C [28.8 (+/- 5.0) mL.kg(-1).min(-1)], but there was no difference between EC and IC. VT1 was significantly higher in EC than C [EC = 69.0 (+/- 9.4) W; IC = 62.4 (+/- 13.0) W; C = 52.1 (+/- 11.8) W], but no significant difference was observed in VT2 [EC = 103.5 (+/- 18.8) W; IC = 92.0 (+/- 22.0) W; C = 85.6 (+/- 19.7) W]. These results show that elite indoor rock climbers elicit higher aerobic fitness profile than control subjects when measured with an upper body test.
Resumo:
Polymer-modified mortar is widely used to set ceramic tiles used as external finishing for high rise buildings in countries such as Brazil, Israel, Singapore and Portugal, mainly because it shows better bond strength and flexibility as compared to the traditional ones. Despite this, the results in the literature already published concerning the long-term performance of those composite mortars are is not conclusive. This paper, based on a laboratory program, compared the performance over time of four commercial polymer-modified adhesive mortars exposed to a typical Brazilian outdoor aging environment and to an indoor environment in terms of mortar flexibility and the bond strength to porcelain tiles. The results show that under laboratory condition, the mortars are more flexible and have higher bond strength than under external condition, and that there is an important correlation between the transversal deformability and the bond strength. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: (a) conventional air distribution system with ceiling supply and return; (b) conventional air distribution system with ceiling supply and return near the floor; (c) underfloor air distribution system; and (d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the indoor/outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Florida Spodosols axe sandy, inherently low in Fe- and Al-based minerals, and sorb phosphorus (P) poorly. We evaluated runoff and leachate P losses from a typical Florida Spodosol amended with biosolids and triple superphosphate (TSP). Phosphorus losses were evaluated with traditional indoor rainfall simulations but used a double-deck box arrangement that allowed leaching and runoff to be determined simultaneously. Biosolids (Lakeland, OCUD, Milorganite, and Disney) represented contrasting values of total P, percent water-extractable p (PWEP), and percentage of solids. All P sources were surface applied at 224 kg P ha(-1), representing a soil P rate typical of N-based biosolids application. All biosolids-P sources lost less P than TSp, and leachate-P losses generally dominated. For Lakeland-amended I soil, bioavailable P (BAP) was mainly lost by runoff (81% of total BAP losses). This behavior was due to surface scaling and 1 drying after application of the slurry (31 g kg(-1) solids), material. For all other P sources, BAP losses in leachate were much,greater than in runoff, representing 94% of total BAP losses for TSP, 80% for Milorganite, 72% for Disney, and 69% for OCUD treatments. Phosphorus leaching can be extreme and represents a great concern in many coarse-textured Florida Spodosols, and other coastal plain soils with low P-sorption,capacities. The PWEP values of P sources were significantly correlared with total P and BAP losses in runoff and leachate. The PWEP of a source can serve as a good indicator of potential P loss when amended to sandy soils with low P-retention capacities.
Resumo:
Uranium is a natural radioactive metallic element; its effect on the organism is cumulative, and chronic exposure to this element can induce carcinogenesis. Three cities of the Amazon region-Monte Alegre, Prainha, and Alenquer-in North Brazil, are located in one of the largest uranium mineralization areas of the world. Radon is a radioactive gas, part of uranium decay series and readily diffuses through rock. In Monte Alegre, most of the houses are built of rocks removed from the Earth`s crust in the forest, where the uranium reserves lie. The objective of the present work is to determine the presence or absence of genotoxicity and risk of carcinogenesis induced by natural exposure to uranium and radon in the populations of these three cities. The frequency of micronuclei (MN) and chromosomal aberrations (CA) showed no statistically significant differences between the control population and the three study populations (P > 0.05). MN was also analyzed using the fluorescence in situ hybridization (FISH) technique, with a centromere-specific probe. No clastogenic and/or aneugenic effects were found in the populations. Using FISH analysis, other carcinogenesis biomarkers were analyzed, but neither the presence of the IGH/BCL2 translocation nor an amplification of the MYC gene and 22q21 region was detected. Clastogenicity and DNA damage were also not found in the populations analyzed using the alkaline comet assay. The mitotic index showed no cytotoxicity in the analyzed individuals` lymphocytes. Once we do not have data concerning radiation doses from other sources, such as cosmic rays, potassium, thorium, or anthropogenic sources, it is hard to determine if uranium emissions in this geographic region where our study population lives are too low to cause significant DNA damage. Regardless, genetic analyses suggest that the radiation in our study area is not high enough to induce DNA alterations or to interfere with mitotic apparatus formation. It is also possible that damages caused by radiation doses undergo cellular repair.
Symptoms after mould exposure including Stachybotrys chartarum, and comparison with darkroom disease
Resumo:
P>Background: Mould-attributed symptoms have included features which overlap with unexplained syndromes such as sick building syndrome. Objectives: We describe questionnaire and chart review findings in patients following exposure to moulds which include Stachybotrys and compare responses with two control groups. Methods: Thirty-two patients presented with symptoms attributed to mould exposures. Exposure identification for 25 patients had reported S tachybotrys chartarum as well as other mould (Aspergillus, Penicillium), 88% at work. The remaining seven had professionally visualized or self-reported/photographic exposure evidence only. A chart review was performed and a follow-up with a questionnaire, including questions on current health status, and nonspecific symptoms. Results: Cough, shortness of breath and chest tightness (at presentation) were reported in 79%, 70% and 64%, respectively, and persisted > 6 weeks in 91%. Skin test(s) were positive to fungal extract(s) in 30%. Seventeen returned questionnaires were obtained 3.1 (SD 0.5) years after the initial clinic assessment. Among this subgroup, persisting asthma-like symptoms and symptoms suggestive of sick building syndrome were frequent, and similar to a group previously assessed for darkroom disease among medical radiation technologists. The mould-exposed group more commonly reported they were bothered when walking in a room with carpets, complained of a chemical or metallic taste in their mouth, and had problems in concentration when compared with a control physiotherapist group (P < 0.005). Conclusions: Although only a minority with health concerns from indoor mould exposure had demonstrable mould-allergy, a significant proportion had asthma-like symptoms. Other symptoms were also common and persistent after the initial implicated exposure.
Resumo:
Background: Environmental factors may influence the development of allergen sensitization and asthma. The aim of this study was to evaluate the role of endotoxin and allergen exposure in early life as a risk factor for recurrent wheezing. Methods: One hundred and four infants from low-income families, at high risk of asthma, were enrolled at birth. Dust samples were collected from the bedding and bedroom floor within 6 months after birth. Recurrent wheezing was defined as 3 or more wheezing episodes in the past year. Endotoxin was determined by Limulus amebocyte lysate assay, and major indoor allergens were quantitated by ELISA in dust extracts. IgE antibodies were measured by ImmunoCAP at 30 months of age. Results: At 30 months, 51 of the 99 infants who completed the study (51.5%) had recurrent wheezing. Respiratory infection was strongly associated with recurrent wheezing (OR 6.67, 95% CI 1.96-22.72), whereas exclusive breastfeeding for at least 1 month was a protective factor (OR 0.09, 95% CI 0.01-0.51). Exposure to high levels of mouse allergen was more frequent among non-recurrent wheezers, approaching significance (OR 0.12, 95% CI 0.01-1.13; p=0.064). None of the children were sensitized to mouse. Sensitization to mite was found in 26/90 (28.8%) children, with no association with recurrent wheezing. Conclusion: Respiratory infection was strongly associated with recurrent wheezing in the first 30 months of life, in children at high risk of asthma, living in a socially deprived community in Brazil. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Animals inheriting the slick hair gene have a short, sleek, and sometimes glossy coat. The objective of the present study was to determine whether slick-haired Holstein cows regulate body temperature more effectively than wild-type Holstein cows when exposed to an acute increase in heat stress. Lactating slick cows (n = 10) and wild-type cows (n = 10) were placed for 10 h in an indoor environment with a solid roof, fans, and evaporative cooling or in an outdoor environment with shade cloth and no fans or evaporative cooling. Cows were exposed to both environments in a single reversal design. Vaginal temperature, respiration rate, surface temperature, and sweating rate were measured at 1200, 1500, 1800, and 2100 h (replicate 1) or 1200 and 1500 h (replicate 2), and blood samples were collected for plasma cortisol concentration. Cows in the outdoor environment had higher vaginal and surface temperatures, respiration rates, and sweating rates than cows in the indoor environment. In both environments, slick-haired cows had lower vaginal temperatures (indoor: 39.0 vs. 39.4 degrees C; outdoor 39.6 vs. 40.2 degrees C; SEM = 0.07) and respiration rate (indoor: 67 vs. 79 breaths/min; outdoor 97 vs. 107 breaths/min; SEM = 5.5) than wild-type cows and greater sweating rates in unclipped areas of skin (indoor: 57 vs. 43 g.h(-1)/m(2); outdoor 82 vs. 61 g.h(-1)/m(2); SEM = 8). Clipping the hair at the site of sweating measurement eliminated the difference between slick-haired and wild-type cows. Results indicate that slick-haired Holstein cows can regulate body temperature more effectively than wild-type cows during heat stress. One reason slick-haired animals are better able to regulate body temperature is increased sweating rate.