918 resultados para High-risk Patients


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The epidemiology of liver disease in patients admitted to emergency rooms is largely unknown. The current study aimed to measure the prevalence of viral hepatitis B and C infection and pathological laboratory values of liver disease in such a population, and to study factors associated with these measurements. METHODS: Cross-sectional study in patients admitted to the emergency room of a university hospital. No formal exclusion criteria. Determination of anti-HBs, anti-HCV, transferrin saturation, alanine aminotransferase, and obtaining answers from a study-specific questionnaire. RESULTS: The study included 5'036 patients, representing a 14.9% sample of the target population during the study period. Prevalence of anti-HBc and anti-HCV was 6.7% (95%CI 6.0% to 7.4%) and 2.7% (2.3% to 3.2%), respectively. Factors independently associated with positive anti-HBc were intravenous drug abuse (OR 18.3; 11.3 to 29.7), foreign country of birth (3.4; 2.6 to 4.4), non-white ethnicity (2.7; 1.9 to 3.8) and age > or =60 (2.0; 1.5 to 2.8). Positive anti-HCV was associated with intravenous drug abuse (78.9; 43.4 to 143.6), blood transfusion (1.7; 1.1 to 2.8) and abdominal pain (2.7; 1.5 to 4.8). 75% of all participants were not vaccinated against hepatitis B or did not know their vaccination status. Among anti-HCV positive patients only 49% knew about their infection and 51% reported regular alcohol consumption. Transferrin saturation was elevated in 3.3% and was associated with fatigue (prevalence ratio 1.9; 1.2 to 2.8). CONCLUSION: Emergency rooms should be considered as targets for public health programs that encourage vaccination, patient education and screening of high-risk patients for liver disease with subsequent referral for treatment if indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: We studied the association of baseline fasting plasma glucose (FPG) levels with survival and coronary artery disease (CAD) progression among postmenopausal women without unstable angina. METHODS: Women were recruited from seven centers in the Women's Angiographic Vitamin and Estrogen Trial (WAVE) (n = 423). Event follow-up was available for 400 women (65.1 +/- 8.5 years, 66% white, 92% hypertensive, 19% smokers, 67% hypercholesterolemic). Thirty-eight percent of the women had diabetes or FPG > 125 mg/dL, and 21% had a fasting glucose 100-125 mg/dL. Follow-up angiography was performed in 304 women. Cox regression was used to model survival from a composite outcome of death or myocardial infarction (D/MI, 26 events; median follow-up 2.4 years). Angiographic progression was analyzed quantitatively using linear regression accounting for baseline minimum lumen diameter (MLD), follow-up time, and intrasubject correlations using generalized estimating equations. Regression analyses were adjusted for follow-up time, baseline age, treatment assignment, and Framingham risk (excluding diabetes). RESULTS: Women with impaired fasting glucose/diabetes mellitus (IFG/DM) had a relative risk (RR) of D/MI of 4.2 ( p = 0.009). In all women, each 10 mg/dL increase in FPG was associated with an 11% increase ( p < 0.001) in the hazard of D/MI. Each 10 mg/dL increase in FPG was associated with a 6.8 mum decrease in MLD over the follow-up period ( p = 0.005). CONCLUSIONS: Higher FPG is associated with increased risk of D/MI and greater narrowing of the coronary lumen in women with CAD. Aggressive monitoring of glucose levels may be beneficial for secondary CAD prevention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The monoclonal antibody anti-CD66 labeled with (99m)Tc is widely used as Scintimun((R)) granulocyte for bone marrow immunoscintigraphy. Further, recently performed clinical radioimmunotherapy studies with [(90)Y]Y-anti-CD66 proved to be suitable for the treatment of hematologic malignancies. Before radioimmunotherapy with [(90)Y]Y-anti-CD66, dosimetric estimations are required to minimize radiotoxicity and determine individual applicable activities. Planar imaging, using gamma-emitting radionuclides, is conventionally carried out to estimate the absorbed organ doses. In contrast, immuno-PET (positron emission tomography) enables the quantification of anti-CD66 accumulation and provides better spatial and temporal resolution. Therefore, in this study, a semiautomated radiosynthesis of [(18)F] F-anti-CD66 was developed, using the (18)F-acylation agent, N-succinimidyl-4-[(18)F]fluorobenzoate ([(18)F]SFB). As a proof of concept, an intraindividual comparison between PET and conventional scintigraphy, using (18)F- and (99m)Tc-labeled anti-CD66 in 1 patient with high-risk leukemia, is presented. Both labeled antibodies displayed a similar distribution pattern with high preferential uptake in bone marrow. Urinary excretion of [(18)F] F-anti-CD66 was increased and bone marrow uptake reduced, in comparison to [(99m)Tc]Tc-anti-CD66. Nevertheless, PET-based dosimetry with [(18)F] F-anti-CD66 could provide additional information to support conventional scintigraphy. Moreover, [(18)F]F-anti-CD66 is ideally suited for bone marrow imaging using PET.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND:Accurate quantification of the prevalence of human immunodeficiency virus type 1 (HIV-1) drug resistance in patients who are receiving antiretroviral therapy (ART) is difficult, and results from previous studies vary. We attempted to assess the prevalence and dynamics of resistance in a highly representative patient cohort from Switzerland. METHODS:On the basis of genotypic resistance test results and clinical data, we grouped patients according to their risk of harboring resistant viruses. Estimates of resistance prevalence were calculated on the basis of either the proportion of individuals with a virologic failure or confirmed drug resistance (lower estimate) or the frequency-weighted average of risk group-specific probabilities for the presence of drug resistance mutations (upper estimate). RESULTS:Lower and upper estimates of drug resistance prevalence in 8064 ART-exposed patients were 50% and 57% in 1999 and 37% and 45% in 2007, respectively. This decrease was driven by 2 mechanisms: loss to follow-up or death of high-risk patients exposed to mono- or dual-nucleoside reverse-transcriptase inhibitor therapy (lower estimates range from 72% to 75%) and continued enrollment of low-risk patients who were taking combination ART containing boosted protease inhibitors or nonnucleoside reverse-transcriptase inhibitors as first-line therapy (lower estimates range from 7% to 12%). A subset of 4184 participants (52%) had >or= 1 study visit per year during 2002-2007. In this subset, lower and upper estimates increased from 45% to 49% and from 52% to 55%, respectively. Yearly increases in prevalence were becoming smaller in later years. CONCLUSIONS:Contrary to earlier predictions, in situations of free access to drugs, close monitoring, and rapid introduction of new potent therapies, the emergence of drug-resistant viruses can be minimized at the population level. Moreover, this study demonstrates the necessity of interpreting time trends in the context of evolving cohort populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis. RESULTS Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio=0.95, 95% CI=0.74-1.21, P=0.67). Target lesion revascularization was also comparable between the groups (hazard ratio=0.89, 95% CI=0.65-1.22, P=0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio=0.52, 95% CI=0.28-0.96, P=0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4years (hazard ratio=0.15, 95% CI=0.03-0.70, P=0.02). CONCLUSIONS In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4years. Rates of stent thrombosis were significantly lower with BP-DES.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Thermal Nd:YAG laser energy is well known for the purpose of blood coagulation. However, little is known about the bleeding frequency following laser-assisted oral surgery in patients on coumarin drugs. Therefore, the purpose of this study was to compare retrospectively the frequency of bleeding complications following Nd:YAG laserassisted versus conventional local coagulation of blood in oral surgery. METHOD AND MATERIALS In October 2002, minor oral surgical interventions were found to be indicated in a total of 45 cardiac risk patients. In Group 1, blood coagulation was yielded in 24 patients with a Nd:YAG laser system, whereas in Group 2, treatment was performed in 21 patients with conventional means of local hemostasis. All therapies were performed continuing anticoagulant therapy between November 2002 and March 2003. Clinical data were recorded retrospectively from patient charts in May 2007. RESULTS In both Groups 1 and 2, a total of two bleeding complications were recorded. However, local re-interventions were sufficient for local hemostasis. CONCLUSION These results indicate that Nd:YAG laser-assisted local hemostasis was not able to prevent bleeding complications completely. Within the limitations of this retrospective study it was concluded that in patients with anticoagulant treatment undergoing minor oral surgery, Nd:YAG laser-assisted local hemostasis is not superior to conventional methods of blood coagulation with respect to the frequency of bleeding complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine the perception and knowledge of targeted ultrasound in women who screen positive for Down syndrome in the first or second trimester, and to assess the perceived detection rate of Down syndrome by targeted ultrasound in this population. While several studies have reported patient perceptions’ of routine ultrasound, no study has specifically examined knowledge regarding the targeted ultrasound and its role in detecting Down syndrome. A targeted ultrasound is a special ultrasound during the second trimester offered to women who may be at a higher-than-average risk of having a baby with some type of birth defect or complication. The purpose of the ultrasound is to evaluate the overall growth and development of the baby as well as screen for birth defects and genetic conditions. Women under the age of 35 referred for an abnormal first or second trimester maternal serum screen to several Houston area clinics were asked to complete a questionnaire to obtain demographic and ultrasound knowledge information as well as assess perceived detection rate of Down syndrome by ultrasound. Seventy-seven women completed the questionnaire and participated in the study. Our findings revealed that women have limited background knowledge about the targeted ultrasound and its role in detecting Down syndrome. These findings are consistent with other studies that have reported a lack of understanding about the purpose of ultrasound examinations. One factor that seems to increase background knowledge about the targeted ultrasound is individuals having a higher level of education. However, most participants regardless of race, education, income, and exposure to targeted ultrasound information did not know the capabilities of a targeted ultrasound. This study confirmed women lack background knowledge about the targeted ultrasound and do not know enough about the technology to form a perception regarding its ability to detect Down syndrome. Additional studies to identify appropriate education techniques are necessary to determine how to best inform our patient population about targeted ultrasound.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Prediction studies in subjects at Clinical High Risk (CHR) for psychosis are hampered by a high proportion of uncertain outcomes. We therefore investigated whether quantitative EEG (QEEG) parameters can contribute to an improved identification of CHR subjects with a later conversion to psychosis. METHODS This investigation was a project within the European Prediction of Psychosis Study (EPOS), a prospective multicenter, naturalistic field study with an 18-month follow-up period. QEEG spectral power and alpha peak frequencies (APF) were determined in 113 CHR subjects. The primary outcome measure was conversion to psychosis. RESULTS Cox regression yielded a model including frontal theta (HR=1.82; [95% CI 1.00-3.32]) and delta (HR=2.60; [95% CI 1.30-5.20]) power, and occipital-parietal APF (HR=.52; [95% CI .35-.80]) as predictors of conversion to psychosis. The resulting equation enabled the development of a prognostic index with three risk classes (hazard rate 0.057 to 0.81). CONCLUSIONS Power in theta and delta ranges and APF contribute to the short-term prediction of psychosis and enable a further stratification of risk in CHR samples. Combined with (other) clinical ratings, EEG parameters may therefore be a useful tool for individualized risk estimation and, consequently, targeted prevention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence-based decisions on indicated prevention in early psychosis require large-scale studies on the pathways to care in high-risk subjects. EPOS (The European Prediction of Psychosis Study), a prospective multi-center, naturalistic field study in four European countries (Finland, Germany, The Netherlands and England), was designed to acquire accurate knowledge about pathways to care and delay in obtaining specialized high risk care. Our high risk sample (n=233) reported on average 2.9 help-seeking contacts, with an average delay between onset of relevant problems to initial help-seeking contact of 72.6 weeks, and between initial help-seeking contact and reaching specialized high risk care of 110.9 weeks. This resulted in a total estimated duration of an unrecognized risk for psychosis of 3 ½ years. Across EPOS EU regions, about 90% of care pathway contacts were within professional health care sectors. Between EPOS regions, differences in the pathways parameters including early detection and health-care systems were often very pronounced. High-risk participants who later made transition to a full psychotic disorder had significantly longer delays between initial help-seeking and receiving appropriate interventions. Our study underlines the need for regionally adapted implementation of early detection and intervention programs within respective mental health and health care networks, including enhancing public awareness of early psychosis.

Relevância:

100.00% 100.00%

Publicador: