905 resultados para High-performance liquid chromatographic
Resumo:
Gaia is the most ambitious space astrometry mission currently envisaged and is a technological challenge in all its aspects. We describe a proposal for the payload data handling system of Gaia, as an example of a high-performance, real-time, concurrent, and pipelined data system. This proposal includes the front-end systems for the instrumentation, the data acquisition and management modules, the star data processing modules, and the payload data handling unit. We also review other payload and service module elements and we illustrate a data flux proposal.
Resumo:
The last economic crisis raised huge challenges for nonprofit organizations. It is now critical for nonprofit organizations to show not only their social legitimacy but also their efficiency and competency to claim for grants (Kearns, Bell, Deem, & McShane, 2012). High Performance Work Practices (HPWP) are a way to foster performance and thus to answer challenges nonprofit organizations are currently facing. However, such practices have until then only been considered for the corporate world. The entire philosophy behind nonprofit organizations contrasts radically from the for-profit sector. Human resources management in particular may differ as well. The aim of this article is precisely to analyze the challenges of implementing HPWP in nonprofit organizations. In order to explore those challenges, we study the HR practices of a nonprofit organization based in UK that struggles against poverty. Discussion of results highlights good practices that should be applied along the nonprofit sector.
Resumo:
Viime vuosien nopea kehitys on kiihdyttänyt uusien lääkkeiden kehittämisprosessia. Kombinatorinen kemia on tehnyt mahdolliseksi syntetisoida suuria kokoelmia rakenteeltaan toisistaan poikkeavia molekyylejä, nk. kombinatorisia kirjastoja, biologista seulontaa varten. Siinä molekyylien rakenteeseen liittyvä aktiivisuus tutkitaan useilla erilaisilla biologisilla testeillä mahdollisten "osumien" löytämiseksi, joista osasta saatetaan myöhemmin kehittää uusia lääkeaineita. Jotta biologisten tutkimusten tulokset olisivat luotettavia, on syntetisoitujen komponenttien oltava mahdollisimman puhtaita. Tämän vuoksi tarvitaan HTP-puhdistusta korkealaatuisten komponenttien ja luotettavan biologisen tiedon takaamiseksi. Jatkuvasti kasvavat tuotantovaatimukset ovat johtaneet näiden puhdistustekniikoiden automatisointiin ja rinnakkaistamiseen. Preparatiivinen LC/MS soveltuu kombinatoristen kirjastojen nopeaan ja tehokkaaseen puhdistamiseen. Monet tekijät, esimerkiksi erotuskolonnin ominaisuudet sekä virtausgradientti, vaikuttavat preparatiivisen LC/MS puhdistusprosessin tehokkuuteen. Nämä parametrit on optimoitava parhaan tuloksen saamiseksi. Tässä työssä tutkittiin emäksisiä komponentteja erilaisissa virtausolosuhteissa. Menetelmä kombinatoristen kirjastojen puhtaustason määrittämiseksi LC/MS-puhdistuksen jälkeen optimoitiin ja määritettiin puhtaus joillekin komponenteille eri kirjastoista ennen puhdistusta.
Resumo:
Suunniteltiin ja rakennettiin suoraa vääntömomenttisäätöä soveltava taajuudenmuuttajakäyttö oikosulkumoottorin ohjaukseen korvaamaan passiivinen jarrukäyttö. Laite on kuntoutuslaite, jolla tehdään lihasvoiman mittauksia ja voimaharjoituksia. Selvitettiin kaupallisten moottoreiden ja taajuudenmuuttajien suoritusominaisuuksia ja tämän perusteella valittiin käyttöön sopivat laitteet. Työssä esitetään kaksi oikosulkumoottorin ohjaustapaa: vektorisäätö ja suora vääntömomenttisäätö. Merkittävin osa tästä työstä käsittelee - tarkan turvallisuussuunnitelman lisäksi - kuntoutuslaitteen prototyypin komponentteja, kokoamista ja suoritustestien tuloksia.
Resumo:
Clúster format per una màquina principal HEAD Node més 19 nodes de càlcul de la gama SGI13 Altix14 XE Servers and Clusters, unides en una topologia de màster subordinat, amb un total de 40 processadors Dual Core i aproximadament 160Gb de RAM.
Resumo:
The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples
Resumo:
A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.
High-Performance-Tensile-Strength Alpha-Grass Reinforced Starch-Based Fully Biodegradable Composites
Resumo:
Though there has been a great deal of work concerning the development of natural fibers in reinforced starch-based composites, there is still more to be done. In general, cellulose fibers have lower strength than glass fibers; however, their specific strength is not far from that of fiberglass. In this work, alpha-fibers were obtained from alpha-grass through a mild cooking process. The fibers were used to reinforce a starch-based biopolymer. Composites including 5 to 35% (w/w) alpha-grass fibers in their formulation were prepared, tested, and subsequently compared with those of wood- and fiberglass-reinforced polypropylene (PP). The term “high-performance” refers to the tensile strength of the studied composites and is mainly due to a good interphase, a good dispersion of the fibers inside the matrix, and a good aspect ratio. The tensile strength of the composites showed a linear evolution for fiber contents up to 35% (w/w). The strain at break of the composites decreased with the fiber content and showed the stiffening effects of the reinforcement. The prepared composites showed high mechanical properties, even approaching those of glass fiber reinforced composites
Resumo:
Monolithic stationary phases represent a new generation of chromatographic separation media. These phases consist of a continuous separation bed prepared by in situ polymerization or consolidation inside the column tubing. In recent years, their simple preparation procedure, unique properties and excellent performance have attracted quite remarkable attention in liquid chromatography and capillary electrochromatography. This review summarizes the preparation, characterization and applications of monolithic stationary phases. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different separation modes.
Resumo:
This paper presents a simple and practical thermogravimetric method for determining the layer thickness of immobilized polymer stationary phases used in reversed-phase high-performance liquid chromatography. In this method, the weight loss of different polysiloxanes immobilized onto chromatographic supports, determined over the temperature range 150-650 ºC, demonstrated excellent agreement with the sum of carbon and hydrogen content obtained by elemental analysis. The results presented here suggest that the thermogravimetric procedure is an accurate and precise method to determine the polymeric material content on polymer-coated stationary phases.
Resumo:
A UV spectrophotometric method was developed and validated and a chromatographic method was adapted from the American Pharmacopeia for the analysis of Fluoxetine Hydrochloride capsules. Ethanol was used as solvent for the spectrophotometric method, with detection and determination at 276 nm. The separation for the chromatographic method was carried out using the reversed-phase column LC-8, triethylamine buffer, stabilizer free tetrahydrofuran and methanol (5:3.5:1.5), pH 6.0 as mobile phase and detection at 227 nm. The results obtained for both methods showed to be accurate, precise, robust and linear over the concentration range 100.00 - 300.00 µg/mL and 40.00 - 80.00 µg/mL of fluoxetine hydrochloride for the spectrophotometric and chromatographic methods, respectively. The accuracy of the methods was evaluated by a recovery test and showed results between 98.89 and 101.10%.
Resumo:
The chemical stability of enalapril drug substance and tablets was studied by a stability-indicating liquid chromatographic method. Stress testing was performed on drug substance under various conditions. Accelerated stability testing was carried out for different formulations of enalapril tablets. Chromatographic separation was achieved on a RP-18 column, using a mobile phase of methanol phosphate buffer at 1.0 mL min"1 and UV detection. Degradation of the drug substance was greater under hydrolytic conditions. After 180 days of accelerated stability testing most enalapril tablets showed more than 10% of degradation. Enalapril drug substance and tablets showed instability under stress and accelerated testing respectively, with possible implications on the therapeutic activity.
Resumo:
A reversed-phase HPLC method was developed and validated to separate and simultaneously quantify the association of betamethasone sodium phosphate (BP) and betamethasone dipropionate (BD) in injectable suspensions. Chromatographic conditions were ternary gradient elution at 1.6 mL/min on a C18 column with 254 nm. The linearity of the method was established in the range 120 to 280 mg/mL BD, and 48 to 112 mg/mL BP. The RSD of intermediate precision of the method was <1% and recoveries were 99-101% for both drugs. The method proved selective, linear, precise, accurate and robust for quantifying BP and BD in commercial injectable suspensions.
Resumo:
A selective and accurate stability-indicating gradient reverse phase ultra performance liquid chromatographic method has been developed and validated for the simultaneous determination of nizatidine, methylparaben and propylparaben in pharmaceutical oral liquid formulation. The separation was achieved on Acquity UPLC TM HSS T3 1.8 µm column by using mobile phase containing a gradient mixture of solvent A (0.02 Mol L-1 KH2PO4, pH 7.5) and B (60:40 v/v mixture of methanol and acetonitrile) at flow rate of 0.4 mL min-1. Drug product was exposed to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness.
Resumo:
An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR).