949 resultados para HADES – Hades Active Delay Evaluation System


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents and discusses the results of the serviciability and use condition tests carried on an innovative solution for partitions, designated AdjustMembrane developed within a research project. The proposed system is a modular non-loadbearing wall, tensioned between the pavements and ceiling slabs, which are used as anchoring elements. It allows several advantages, related with the weight reduction to achieve a good sustainable performance, such as the reduction of construction costs, energy, and materials, and it is easy to recycle and to reuse, allowing self-construction. Apart from a general presentation of the partition technology, this paper presents and discusses the results of experimental tests carried out. From the results obtained, it is possible to conclude that the solution fulfils the requirements for this typology of wall in terms of resistance to horizontal loads induced by soft and hard body impacts.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Kidney renal failure means that one’s kidney have unexpectedly stopped functioning, i.e., once chronic disease is exposed, the presence or degree of kidney dysfunction and its progression must be assessed, and the underlying syndrome has to be diagnosed. Although the patient’s history and physical examination may denote good practice, some key information has to be obtained from valuation of the glomerular filtration rate, and the analysis of serum biomarkers. Indeed, chronic kidney sickness depicts anomalous kidney function and/or its makeup, i.e., there is evidence that treatment may avoid or delay its progression, either by reducing and prevent the development of some associated complications, namely hypertension, obesity, diabetes mellitus, and cardiovascular complications. Acute kidney injury appears abruptly, with a rapid deterioration of the renal function, but is often reversible if it is recognized early and treated promptly. In both situations, i.e., acute kidney injury and chronic kidney disease, an early intervention can significantly improve the prognosis.The assessment of these pathologies is therefore mandatory, although it is hard to do it with traditional methodologies and existing tools for problem solving. Hence, in this work, we will focus on the development of a hybrid decision support system, in terms of its knowledge representation and reasoning procedures based on Logic Programming, that will allow one to consider incomplete, unknown, and even contradictory information, complemented with an approach to computing centered on Artificial Neural Networks, in order to weigh the Degree-of-Confidence that one has on such a happening. The present study involved 558 patients with an age average of 51.7 years and the chronic kidney disease was observed in 175 cases. The dataset comprise twenty four variables, grouped into five main categories. The proposed model showed a good performance in the diagnosis of chronic kidney disease, since the sensitivity and the specificity exhibited values range between 93.1 and 94.9 and 91.994.2 %, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tese de Doutoramento (Programa doutoral em Engenharia de Materiais)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Zearalenone (ZEN) is a mycotoxin that has relatively low acute toxicity. However, it is a potent oestrogen, interfering with the reproductive tract of animals. Among other effects, ZEN decreases animals fertility, and induces fibrosis in the uterus, breast cancer and endometrial carcinoma (Zinedine et al., 2007). Anti-mycotoxin additives (AMA) are defined as a group of products that, when added to animal feed, are capable of adsorbing, inactivating, or neutralizing mycotoxins in the gastrointestinal tract of animals. One example of these products are adsorbents based on yeast cell walls, a safe and beneficial animal feed additive (Abreu et al., 2008). When based on active cells, yeast based products also act as a probiotic, contributing to improve the general animal health because it stimulates their immune system and promotes the integrity of intestinal mucosa (Albino et al., 2006). Strains of Saccharomyces cerevisiae isolated from silage were tested for their ZEN removal capability. Their effect on - and b-zearalenol (-ZOL and b-ZOL) was also tested. Strains were grown on YPD separately supplemented with ZEN, -ZOL and b-ZOL, and their elimination from culture media was quantified over time by HPLC-FL.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Hydrogen, energy, safety, risk, production, transport, storage, filling station, fuelcell

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Locating new wind farms is of crucial importance for energy policies of the next decade. To select the new location, an accurate picture of the wind fields is necessary. However, characterizing wind fields is a difficult task, since the phenomenon is highly nonlinear and related to complex topographical features. In this paper, we propose both a nonparametric model to estimate wind speed at different time instants and a procedure to discover underrepresented topographic conditions, where new measuring stations could be added. Compared to space filling techniques, this last approach privileges optimization of the output space, thus locating new potential measuring sites through the uncertainty of the model itself.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose of the study: Reconstruction of the anterior cruciate ligament (ACL) controls laxity but does not enable restoration of strictly normal 3D kinematics. The purpose of this study was to compare the kinematics of the pathological knee with that of the healthy knee after ACL plasty. This study applied a new ambulatory system using miniature captors. Material and method: Five patients with an isolated injury of the ACL participated in this study. The patients were assessed after injury (T1), at five months (T2), and at 14 months (T3) after surgery. The assessment included laxity (KT-1000), the IKDC score and the Lysholm score. The 3D angles of the knees were measured when walking 30 m on flat ground using a system composed of to small inertia units (3D accelerometer and 3D gyroscope) and a portable recorder. Functional settings were optimised and validating to ensure easy precise measurement of the 3D angles. Symmetry of the two knees was quantified using a symmetry index (SI) (difference in amplitude normalised in relation to mean amplitude) and the correlation coefficient CC. Results: Clinical indicators improved during the follow-up (IKDC T1: 3C, 2C; T2: 5B; T3: 2A, 3B; subjective IKD: 53-95; Lysholm 67-96). Mean laxity improved from 8.6m to 2.5 mm. The gait analysis showed increased symmetry in terms of amplitude for flexion-extension (SI: −17% at T1, −1% at T2, 1% at T3), and an increase in symmetry in terms of the rotation signature (CC: 0.16 at T1, 0.99 at T2, 0.99 at T3). There was no trend to varus-valgus. Discussion: This study demonstrates the clinical application of the new ambulatory system for measuring 3D angles of the knee joint. Joint symmetry increased after ACL plasty but still showed some perturbation at 14 months. The results observed here are in agreement with the literature. Other patients and other types of gait are being analysed. Conclusion: This portable system allows gait analysis outside the laboratory, before and after ACL injury. It is very useful for follow-up after surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An in vitro translation system has been prepared from Plasmodium falciparum by saponin lysis of infected-erythrocytes to free parasites which were homogeneized with glass beads, centrifuged to obtain a S-30 fraction followed by Sephadex G-25 gel filtration. This treatment produced a system with very low contamination of host proteins (<1%). The system, optimized for Mg2+ and K+, translates endogenous mRNA and is active for 80 min which suggests that their protein factors and mRNA are quite stable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The diagnosis of inflammatory bowel disease (IBD), comprising Crohn's disease (CD) and ulcerative colitis (UC), continues to present difficulties due to unspecific symptoms and limited test accuracies. We aimed to determine the diagnostic delay (time from first symptoms to IBD diagnosis) and to identify associated risk factors. A total of 1591 IBD patients (932 CD, 625 UC, 34 indeterminate colitis) from the Swiss IBD cohort study (SIBDCS) were evaluated. The SIBDCS collects data on a large sample of IBD patients from hospitals and private practice across Switzerland through physician and patient questionnaires. The primary outcome measure was diagnostic delay. Diagnostic delay in CD patients was significantly longer compared to UC patients (median 9 versus 4 months, P < 0.001). Seventy-five percent of CD patients were diagnosed within 24 months compared to 12 months for UC and 6 months for IC patients. Multivariate logistic regression identified age <40 years at diagnosis (odds ratio [OR] 2.15, P = 0.010) and ileal disease (OR 1.69, P = 0.025) as independent risk factors for long diagnostic delay in CD (>24 months). In UC patients, nonsteroidal antiinflammatory drug (NSAID intake (OR 1.75, P = 0.093) and male gender (OR 0.59, P = 0.079) were associated with long diagnostic delay (>12 months). Whereas the median delay for diagnosing CD, UC, and IC seems to be acceptable, there exists a long delay in a considerable proportion of CD patients. More public awareness work needs to be done in order to reduce patient and doctor delays in this target population.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: The diagnosis of inflammatory bowel disease (IBD), comprising Crohn's disease (CD) and ulcerative colitis (UC), continues to present difficulties due to unspecific symptoms and limited test accuracies. We aimed to determine the diagnostic delay (time from first symptoms to IBD diagnosis) and to identify associated risk factors in a national cohort in Switzerland.¦Materials and Methods: A total of 1,591 IBD patients (932 CD, 625 UC, 34 indeterminate colitis) from the Swiss IBD cohort study (SIBDCS) were evaluated. The SIBDCS collects data on a large sample of IBD patients from hospitals and private practice across Switzerland through physician and patient questionnaires. The primary outcome measure was the diagnostic delay.¦Results: Diagnostic delay in CD patients was significantly longer compared to UC patients (median 9 vs. 4 months, P < 0.001). Seventy-five percent of CD patients were diagnosed within 24 months compared to 12 months for UC and 6 months for IC patients. Multivariate logistic regression identified age <40 years at diagnosis (OR 2.15, P = 0.010) and ileal disease (OR 1.69, P = 0.025) as independent risk factors for long diagnostic delay in CD (>24 months). A trend for long diagnostic delay (>12 months) was associated with NSAID intake (OR 1.75, P = 0.093) and male gender (OR 0.59, P = 0.079) in UC patients.¦Conclusions: Whereas the median delay for diagnosing CD, UC, and IC seems to be acceptable, there exists a long delay in a considerable proportion of CD patients. More public awareness work needs to be done in order to reduce patient's and doctor's delay in this target population.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In order to evaluate the Organon Teknika MB/BacT system used for testing indirect susceptibility to the alternative drugs ofloxacin (OFLO), amikacin (AMI), and rifabutin (RIF), and to the usual drugs of standard treatment regimes such as rifampin (RMP), isoniazid (INH), pyrazinamide (PZA), streptomycin (SM), ethambutol (EMB), and ethionamide (ETH), cultures of clinical specimens from 117 patients with pulmonary tuberculosis under multidrug-resistant investigation, admitted sequentially for examination from 2001 to 2002, were studied. Fifty of the Mycobacterium tuberculosis cultures were inoculated into the gold-standard BACTEC 460 TB (Becton Dickinson) for studying resistance to AMI, RIF, and OFLO, and the remaining 67 were inoculated into Lowenstein Jensen (LJ) medium (the gold standard currently used in Brazil) for studying resistance to RMP, INH, PZA, SM, EMB, and ETH. We observed 100% sensitivity for AMI (80.8-100), RIF (80.8-100), and OFLO (78.1-100); and 100% specificity for AMI (85.4-100), RIF (85.4-100), and OFLO (86.7-100) compared to the BACTEC system. Comparing the results obtained in LJ we observed 100% sensitivity for RMP (80-100), followed by INH - 95% (81.8-99.1), EMB - 94.7% (71.9-99.7), and 100% specificity for all drugs tested except for PZA - 98.3 (89.5-99.9) at 95% confidence interval. The results showed a high level of accuracy and demonstrated that the fully automated, non-radiometric MB/BacT system is indicated for routine use in susceptibility testing in public health laboratories.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Many patients with an implantable cardioverter-defibrillator (ICD) have indications for magnetic resonance imaging (MRI). However, MRI is generally contraindicated in ICD patients because of potential risks from hazardous interactions between the MRI and ICD system. OBJECTIVE: The purpose of this study was to use preclinical computer modeling, animal studies, and bench and scanner testing to demonstrate the safety of an ICD system developed for 1.5-T whole-body MRI. METHODS: MRI hazards were assessed and mitigated using multiple approaches: design decisions to increase safety and reliability, modeling and simulation to quantify clinical MRI exposure levels, animal studies to quantify the physiologic effects of MRI exposure, and bench testing to evaluate safety margin. RESULTS: Modeling estimated the incidence of a chronic change in pacing capture threshold >0.5V and 1.0V to be less than 1 in 160,000 and less than 1 in 1,000,000 cases, respectively. Modeling also estimated the incidence of unintended cardiac stimulation to occur in less than 1 in 1,000,000 cases. Animal studies demonstrated no delay in ventricular fibrillation detection and no reduction in ventricular fibrillation amplitude at clinical MRI exposure levels, even with multiple exposures. Bench and scanner testing demonstrated performance and safety against all other MRI-induced hazards. CONCLUSION: A preclinical strategy that includes comprehensive computer modeling, animal studies, and bench and scanner testing predicts that an ICD system developed for the magnetic resonance environment is safe and poses very low risks when exposed to 1.5-T normal operating mode whole-body MRI.