929 resultados para GRANULAR ACTIVATED CARBON
Resumo:
环境突发污染事故给人民生活、经济发展和生态环境造成重大影响,研究污染物泄漏造成河流突发污染事故的应急处理方法十分必要。本论文选取苯酚、苯胺和亚甲基蓝等典型污染物为实验对象,采用吸附容量大、密度与水接近的活性炭纤维(ACF)为吸附剂。在自制的河流模型中,研究了ACF以苯酚、苯胺和亚甲基蓝为典型污染物的吸附过程,考察了吸附剂投加量、污染物浓度、吸附剂比表面积、吸附剂投加方式、水流速度与水质等对吸附速率与吸附效果的影响。实验结果表明,ACF能以较快的速率吸附苯酚、苯胺和亚甲基蓝,吸附率都在95%以上; ACF投加量是影响吸附速率最重要的因素,当一次性投加ACF质量之比为 1:2:4时,吸附速率常数之比近似为1:2:4;污染物浓度对吸附速率的影响显著,浓度较低时吸附速率较高。苯酚初始浓度为7mg·L-1时,经过86分钟的吸附,处理后的浓度可以达到地表水Ⅴ类水中挥发酚的限值要求(0.1mg·L-1);在吸附11分钟左右追加适量的ACF,能够明显提高吸附速率;河水流速和河流中的天然有机物、浊度、河水硬度对ACF吸附都不产生显著影响,这说明ACF作为河流突发污染事故应急处理的吸附剂,有广泛的适应性。在实际河水中,ACF对苯酚的吸附过程与在模拟河水中相似,吸附效果显著。实验结果还表明,ACF对苯酚的吸附是放热反应,符合Freundlich模型和Langmuir模型。事故应急处理后,应该及时将吸附了污染物的ACF打捞上来,有利于进行后续处理。 Emergency environmental pollution accidents pose significant impacts on our living, economic development and ecological environment. The study on the approach of emergency control for the contingency caused by leakage of pollutants in rivers is very necessary. In the experiment, phenol, aniline and methylene blue were selected as representative pollutant and activated carbon fiber (ACF) was selected as adsorbent, which has strong adsorption capacity and similar density to water. In the self-made river model, the effects of ACF dosage, pollutant concentration, ACF surface area, ACF adding ways, water flow rate and water quality on adsorption courses were investigated. The experimental results showed that ACF could adsorb pollutant quickly and effectively. The ACF dosage was the most important factor that affected adsorption rate .When the ACF dosage rate was 1:2:4, the constants of adsorption rate was approximately 1:2:4. The effect of pollutant concentrations on the adsorption rate was notable. Faster adsorption rates were achieved at low pollutant concentrations. Phenol concentration reached the limits of volatile phenol in Category Ⅴ surface water (0.1 mg·L-1) after 86 minutes of adsorption with initial phenol concentration of 7 mg·L-1. After 11 minutes of adsorption, certain amount of ACF was added and the adsorption rate was improved significantly. River flow rate and water quality have little effect on the adsorption rate. The adsorption results obtained in actual river water were comparable with that in simulating river water. The results also showed that, ACF on the absorption of phenol is exothermic reaction, witch matched with the Freundlich model and the Langmuir model. After emergency treatment, the ACF absorbed pollutants should be promptly salvaged for follow-up treatment.
Resumo:
近年来各种环境污染事故频发,据统计仅2001~2003年间,发生的各类环境污染事故就高达5606次,其中水污染事故3235次,占全部的57.7%。这些事故不仅给人民生命财产造成巨大损失,也给生态环境造成严重的破坏。因此开发安全高效的应急处理技术迫在眉睫。本研究以筛选高效苯胺降解菌为基础,通过对高效菌降解性能的研究指导将高效菌作为功能郡主投加到已有生物处理系统强化应急处理苯胺突发污染事故废液,取得了良好的效果。 苯胺高效降解菌AN-P1为红球菌(Rhodococcus sp.),其通过间位途径降解苯胺,AN-P1利用苯胺生长和降解的最佳pH为6,最适浓度为2000 mg/L,最适温度为30 ℃,最佳接种量为0.3‰。AN-P1降解含500 mg/L、1000 mg/L、2000 mg/L苯胺的培养物分别经过28 h、24 h、32 h降解,出水苯胺含量能达到《污水综合排放标准》(GB8978-1996)一级标准。但由于苯胺降解过程中释放了大量氨氮,出水氨氮仍较高未能达标排放。而常规SBR系统应急处理效果较差,苯胺和COD去除率均低于10%,出水未能达标排放。活性碳吸附后的回收和后续处理也会带来操作不变和二次污染问题,且处理后出水往往难于达标排放,尚需进行进一步处理。 生物处理系统应急处理后恢复运行处理效果监测和PCR-DGGE图谱分析显示,用AN-P1菌强化应急处理系统后不仅能快速高效的去除苯胺,而且可以有效保障处理系统对污染物的净化性能,有效的保护系统中的功能微生物免受苯胺毒害。 研究结果表明,从实际处理效果、对原有生物系统性能保护及实际应用操作等多方面考虑,用AN-P1菌强化应急处理苯胺突发污染事故在技术上都是可行的。本研究为应急处理苯胺突然污染事故废液提供了新的方法。 Recent years, environment pollution accidents happened frequently, the data showed that there are 5606 accidents between 2001 and 2003, including 3235 water environment accidents, which is 57.7% of all. These accedents not only caused money lost and life lost but also caused serious damage to the ecologicl environment. So exploring highly-effective and secure methods to solve these accidents is an urgent mission. We screened a highly-effective aniline-degrading bacterium and did some researches on its ability to degrade aniline, in order to guide the emergency treatment of aniline containing wastewater that caused by sudden accident pollution with bioaugmentation. A highly-effective aniline-degrading bacterium AN-P1 was isolate and characterized as Rhodococcus sp. It degrades aniline through meta-cleavage pathway. The optimal pH and temperature for cell growth and aniline degradation were 6 and 30 ℃, respectively, and the opitimal concentration of aniline was 2000 mg/L, the optimal inoculation amount was 0.3‰.It took bacterium AN-P1 only 18 h, 24 h and 32 h, respectively, for the treatment of MSB containing 500 mg/L, 1000 mg/L, 2000 mg/L aniline to meet the first grade of national some of the NH4+-N which caused by aniline degradation. It took bacterium AN-P1 only 10 h, 20 h and 32 h, respectively, for the treatment of wastewater containing 500 mg/L, 1000 mg/L, 2000 mg/L aniline to meet the first grade of national integrated wastewater discharge standard. The bacterium AN-P1 can also remove some of the NH4+-N which caused by aniline degradation. It took bacterium AN-P1 only 10 h, 20 h and 32 h, respectively, for the treatment of wastewater containing 500 mg/L, 1000 mg/L, 2000 mg/L aniline to meet the first grade of national integrated wastewater discharge standard. By combing AN-P1 with regular SBR system, it took only 36 h for the emergency treatment of wastewater containing 2000 mg/L aniline under simulating engineering conditions to meet the discharge standard. While the NH4+-N of effluent can not meet the standard because of the high amount NH4+-N caused by aniline degradation. The regular SBR system was not good at aniline and COD removal. The removal efficiency of which are less than 10%. It cost 67.8 g activated carbon to absorbed 1000 mg aniline. It is inconvenient to transport and use it for the emergency treatment of aniline when the sudden pollution accident happened. Meanwhile, it was complex ad hard to recycle the activated carbon and treat the aniline wastewater get from activated carbon recycling too. Hard to meet the effluent standard was also a problem of activated carbon absorption method. According to the PCR-DGGE profile and removal efficiency of pollutants and COD when the systerm recover from emergency treatment, AN-P1 can efficiently protect the microbial community of regular activated sludge system against the aniline. It proved that combing AN-P1 with regular biological system is a feasible strategy for emergency treatment of aniline sudden pollution accident. The research offered a new way for emergency treatment of aniline sudden pollution accident.
Resumo:
Immobilized with PVA,sodium alginate and activated carbon,both Zoogloea sp. and Fusarium sp.strains could degrade phenanthrene and pyrene efficiently.The optimal carrier was made of 100ρ·g -1 L PVA,5 sodium alginateρ·g -1 L and 50 activated carbon ρ·g -1 L.The degradation rates of phenanthrene and pyrene in 10 days were 87.48% and 75.34% by the immobilized bacterium,37.04% and 20.85% higher than those by the free bacterium,and the rates in 15 days were 84.36% and 74.87% by the immobilized fungus,5.35% and 11.23% higher than those by the free fungus.
Resumo:
Optically transparent, crack-free, mesoporous anatase TiO2 thin films were fabricated. The Ag/TiO2 composite films were prepared by incorporating Ag in the pores of TiO2 films with an impregnation method via photoreduction. The as-prepared composite films were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectronic spectra (XPS) and N-2 adsorption. The release behavior of silver ions in the mesoporous composite film was also studied. Moreover, the antimicrobial behaviors of the mesoporous film were also investigated by confocal laser scanning microscopy.
Resumo:
N-Methylimidazolium functionalized strongly basic anion exchange resins in the Cl- form (RCI) and SO46- form (R2SO4) were synthesized and employed for adsorption of Cr(VI) from aqueous solution. FT-IR and elementary analysis proved the structures of anion exchange resins and the content of functional groups. The gel-type strongly basic anion exchange resins had high thermal stability according to TGA and good chemical stability under the experimental conditions. The adsorption behaviors of Cr(VI) on RCI and R2SO4 were studied using the batch technique. It was shown that adsorption equilibrium was reached rapidly within 60 min. The adsorption data for RCI and R2SO4 were consistent with the Langmuir isotherm equation.