966 resultados para Experimental medicine


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To physiologically reconstruct the biliary tract, Crema et al suggested the application of the Monti principle to the biliary tract, already used in humans for the urinary tract. With this technique, a jejunal segment is transversely retubularized. This study aimed to evaluate the efficacy of jejunal tube interposition between the common bile duct and duodenum in dogs.METHODS: Thirteen dogs underwent a laparoscopic common bile duct ligature, followed by a biliodigestive connection by jejunal tube interposition after one week. The levels of glutamic-pyruvic and glutamic-oxalacetic transaminases, total bilirubins, alkaline phosphatase and gamma-glutamyltransferase were assessed before surgery and thereafter weekly until euthanasia, which was performed 6 weeks after biliodigestive connection.RESULTS: Data on 9 dogs were analyzed statistically. The dogs presented with obstructive jaundice after common bile duct ligature, as confirmed by biochemical examination. They showed a statistically significant reduction in cholestasis after biliodigestive connection by jejunal tube interposition and were healthy until the end of the experiment.CONCLUSION: A statistically significant reduction was seen in total bilirubin and canalicular enzymes (alkaline phosphatase and gamma-glutamyltransferase) in the 9 dogs 6 weeks after biliodigestive conviction by jejunal tube interposition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Research in humans has demonstrated that high serum iron (sFe) concentration can predispose to infection, and many infections subsequently result in alterations of host sFe. A decrease in sFe concentration is an early and sensitive indicator of systemic inflammation caused by tissue necrosis, bacterial infections, or endotoxemia in horses. Serum iron parameters in acute equine herpesvirus type 1 (EHV-1) infection have not been evaluated previously. Objectives To document the sFe response to EHV-1 infection and to determine whether or not significant differences in sFe concentration exist between EHV-1 infected horses that develop neurologic disease and those that do not. Animals A total of 14 horses experimentally infected with EHV-1. Methods Data were collected as an ancillary data set during a blinded experimental EHV-1 infection. Horses were infected with the rAb4 strain of EHV-1. Temperature, neurologic score, packed cell volume (PCV), and sFe parameters (sFe concentration, % saturation, and total iron-binding capacity) were recorded daily for 2weeks. Data were evaluated using Wilcoxon signed rank tests and Wilcoxon rank sum tests with Bonferroni corrections. Conclusions and Clinical Relevance Serum iron concentration decreases significantly in a biphasic pattern after EHV-1 infection. There was no significant difference in sFe concentration in horses that developed neurologic disease and those that did not in these experimentally infected animals. Serum iron parameters may be useful in monitoring the clinical course of viral infections such as EHV-1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the rat alveolar socket response to implanted polyethylene tubes filled with a light-cured MTA or Angelus MTA.Study design. Fifty-seven Wistar rats received an implant filled with one of the materials in the dental socket of the right central incisor. After 30, 60, and 90 days, animals were killed, and the right hemimaxillas were removed and processed to be analyzed on light microscopy. After embedding in paraffin, 6-mu m-thick sections were obtained and stained with hematoxylin and eosin. Qualitative and quantitative analyses of the reaction were performed.Results. It was observed that the light-cured MTA presented a similar response compared with Angelus MTA, characterized by the reduction of the chronic inflammatory response and organization of the alveolar bone close to the materials, especially at the 90th day of observation.Conclusions. It was concluded that both materials were well accepted by the alveolar tissue of rats, with the formation of mineralized tissue close to the materials. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e93-e97)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement).Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested.Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio.Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim and method: The objective of this research was to study the effect of homeopathic treatment with Plumbum metallicum (Plumbum met.) on mandibular bone repair in rats.Materials and methods: We analyzed the mandibles of 60 male rats, approximately 3-month-old, randomly divided into three groups of 20 animals each: control, treated with calcitonin, and treated with a homeopathic medicine. A circumscribed bone defect measuring 4 mm in diameter was made in the mandible and covered with a pollytetrafluorethylene (PTFE) barrier. The group treated with calcitonin received 2 IU/kg intramuscularly three times a week; the group treated with Plumbum met. 30c received three drops in water every day. The animals were sacrificed after 7,14,21 and 28 days. The mandibles were removed and submitted to histologic and histomorphometric analyses.Results: Data were analyzed statistically by two-way ANOVA and by the Tukey test. The interaction effect (ANOVA, F df(6; 48) = 4.64; p = 0.001 < 0.05) indicated that the relationship between treatments was not the same at each time of sacrifice. Although statistical analysis of the histomorphometric data showed a similar results for the treated and control groups. But histological analysis showed complete filling of the surgical defect throughout its extent was only for the group treated with Plumbum met.Conclusion: The study demonstrated that for repair of surgical defects in rat mandibles Plumbum met. 30c and control did not differ significantly in histomorphometric terms. Homeopathy (2009) 98, 92-96.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to compare the fluoride-releasing and mechanical properties of an experimental luting glass ionomer cement, which has a modified composition and a commercial luting cement. The experimental powder was obtained by sol-gel process and then, it was used to prepare the experimental cements. The properties of cement pastes, such as setting time and working time, microhardness and diametral tensile strength were determined. Fluoride release from GICs was evaluated at time intervals of 1, 7, 14, 21 and 28 days in deionized water. Atomic force microscopy (AFM) analyses showed that the surface of the experimental cements is more homogeneous than commercial GICs. The mechanical properties and the measure of liberation of fluoride of the two cements were influenced by ratio powder:liquid and chemical composition of the precursor powders. Experimental cements released less fluoride than commercial cements. However, this liberation was more constant during the analyzed period. Thus, the results obtained in this study indicated that the composition of the experimental powder modified by the niobium can lead the formation of the polysalt matrix with good mechanical properties. In other words, we can say that experimental powder offered considerable promise for exploitation in dental field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this work was to evaluate the effect of three commercial mouthwashes on the corrosion resistance of Ti-10Mo experimental alloy. Experiments were made at 37.0 +/- 0.5 degrees C in a conventional three-compartment double wall glass cell containing commercial mouthwashes. Three mouthwashes with different active ingredients were tested: ( I) 0.05% sodium fluoride + 0.03% triclosan; (II) 0.5 g/l cetylpyridinium chloride + 0.05% sodium fluoride; (III) 0.12% chlorohexidine digluconate. The assessment of the individual effect of active ingredients was studied by using 0.05% sodium fluoride. Commercially pure titanium (CP Ti) was used as control. Microstructures from Ti-10Mo experimental alloy and CP Ti were also evaluated using optical microscopy. Ti-10Mo as-cast alloy shows the typical rapidly cooled dendrites microstructure (beta phase) while CP Ti has exhibited a metastable martensitic microstructure. Electrochemical behavior of dental materials here studied was more affected by mouthwash type than by Ti alloy composition or microstructure. In both alloys passivation phenomenon was observed. This process may be mainly related to Ti oxides or other Ti species present in spontaneously formed film. Small differences in passive current densities values may be connected with changes in film porosity and thickness. Protective characteristics of this passive film are lower in 0.05% sodium fluoride + 0.03% triclosan mouthwash than in the other two mouthwashes tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: We describe an experimental model for transanal endorectal pull-through surgery using the method of de]a Torre and Ortega that can be used for training purposes in experimental laboratories.Methods: Ten rabbits were submitted to the transanal endorectal pull-through technique of de la Torre and Ortega. Animals were randomly selected in the Botucatu School of Medicine experimental laboratory. Animals weighted between 2800 and 4400 g. Colons were not prepared, and antibiotic therapy was not used; dipyrone(1) was administered postoperatively for analgesic purposes. We standardized resected segment size, recorded surgical time, and observed Survival and possible complications for 1 month.Results: All animals survived the initial follow-up period without infection. Bowel movements returned quickly, and all animals were evacuating regularly within the first 24 hours. Mean surgical time was 48.6 minutes.Conclusions: the experimental model proposed in this study is very useful for training and improving surgical techniques using the method of de la Torre and Ortega. The rabbit is an excellent animal for this surgery because of its size and postoperative resistance. (c) 2005 Elsevier B.V. All rights reserved.