999 resultados para Estrus detection
Resumo:
A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.
Resumo:
A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.
Resumo:
Crossed immunoelectrophoresis (IEC) was used for detection of free and complexed circulating polisaccharide anodic antigen (AgCA) of Schistosoma mansoni in sera of infected hamsters. An attempt was also done to detect AgCA in human sera from patients infected with S. mansoni. The conditions for isolation and detection of complexed AgCA were established. The sensitivity of IEC was increased by incorporation of 2% polyethylene glicol (PEG) to the agarose and by maintaining the system at 4°C during the electrophoretic run. Free AgCA was detected in 12 and the complexed in 30 of the 37 hamsters sera analysed. Correlation between AgCA (free and complexed) and the parasite load was observed. AgCA was not detected, under the experimental conditions used, in human sera from 7 patients in the acute and 23 in the chronic phase of infection.
Resumo:
Recent studies of mobile Web trends show the continued explosion of mobile-friend content. However, the wide number and heterogeneity of mobile devices poses several challenges for Web programmers, who want automatic delivery of context and adaptation of the content to mobile devices. Hence, the device detection phase assumes an important role in this process. In this chapter, the authors compare the most used approaches for mobile device detection. Based on this study, they present an architecture for detecting and delivering uniform m-Learning content to students in a Higher School. The authors focus mainly on the XML device capabilities repository and on the REST API Web Service for dealing with device data. In the former, the authors detail the respective capabilities schema and present a new caching approach. In the latter, they present an extension of the current API for dealing with it. Finally, the authors validate their approach by presenting the overall data and statistics collected through the Google Analytics service, in order to better understand the adherence to the mobile Web interface, its evolution over time, and the main weaknesses.
Resumo:
In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.
Resumo:
Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.
Resumo:
A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.
Resumo:
Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
In this paper, a damage-detection approach using the Mahalanobis distance with structural forced dynamic response data, in the form of transmissibility, is proposed. Transmissibility, as a damage-sensitive feature, varies in accordance with the damage level. Besides, Mahalanobis distance can distinguish the damaged structural state condition from the undamaged one by condensing the baseline data. For comparison reasons, the Mahalanobis distance results using transmissibility are compared with those using frequency response functions. The experiment results reveal quite a significant capacity for damage detection, and the comparison between the use of transmissibility and frequency response functions shows that, in both cases, the different damage scenarios could be well detected. Copyright (c) 2015 John Wiley & Sons, Ltd.
Resumo:
An Enzyme-linked immunosorbent assay ELISA was evaluated for the detection of IgA antibodies in the human leptospirosis. The assay proved to be sensitive and specific when compared with the ELISA-IgM, in the examinated serum samples. The results found suggest that IgA antibodies became positive later in leptospirosis, and will can be an evolutive indicator in the development of the disease
Resumo:
Specimens from cervical dysplasias or carcinomas and genital condylomata acuminata were retrospectively analysed by in situ hybridization (ISH) with bioti-nylated DNA probes for human papillomavirus (HPV) types 6, 11, 16 and 18. In the control group no case was positive for HPV DNA. In mild/moderate dysplasias, 4 cases (14%) were positive for HPV 6 or 11 and 2 cases (7%), for HPV 16. In the severe dysplasia/in situ carcinoma group, 9 cases (31%) showed presence of DNA of HPV types 16 or 18. Six invasive carcinomas (20%) were positive for HPV type 16 or 18. Among condylomata acuminata, 22 cases (73%) were positive for HPV types 6 or 11. In all ISH-positive cases only one viral type was detected. No correlation between HPV DNA positivity and histological findings of HPV infection was observed. Although less sensitive than some other molecular biology techniques, in situ hybridization with biotinylated DNA probes proved to be simple and useful for detecting and typing HPV in samples routinely received for histopathological analysis.
Resumo:
A bi-enzymatic biosensor (LACC–TYR–AuNPs–CS/GPE) for carbamates was prepared in a single step by electrodeposition of a hybrid film onto a graphene doped carbon paste electrode (GPE). Graphene and the gold nanoparticles (AuNPs) were morphologically characterized by transmission electron microscopy, X-ray photoelectron spectroscopy, dynamic light scattering and laser Doppler velocimetry. The electrodeposited hybrid film was composed of laccase (LACC), tyrosinase (TYR) and AuNPs entrapped in a chitosan (CS) polymeric matrix. Experimental parameters, namely graphene redox state, AuNPs:CS ratio, enzymes concentration, pH and inhibition time were evaluated. LACC–TYR–AuNPs–CS/GPE exhibited an improved Michaelis–Menten kinetic constant (26.9 ± 0.5 M) when compared with LACC–AuNPs–CS/GPE (37.8 ± 0.2 M) and TYR–AuNPs–CS/GPE (52.3 ± 0.4 M). Using 4-aminophenol as substrate at pH 5.5, the device presented wide linear ranges, low detection limits (1.68×10− 9 ± 1.18×10− 10 – 2.15×10− 7 ± 3.41×10− 9 M), high accuracy, sensitivity (1.13×106 ± 8.11×104 – 2.19×108 ± 2.51×107 %inhibition M− 1), repeatability (1.2–5.8% RSD), reproducibility (3.2–6.5% RSD) and stability (ca. twenty days) to determine carbaryl, formetanate hydrochloride, propoxur and ziram in citrus fruits based on their inhibitory capacity on the polyphenoloxidases activity. Recoveries at two fortified levels ranged from 93.8 ± 0.3% (lemon) to 97.8 ± 0.3% (orange). Glucose, citric acid and ascorbic acid do not interfere significantly in the electroanalysis. The proposed electroanalytical procedure can be a promising tool for food safety control.
Resumo:
FCM: UC Bioquímica I - PhD Thesis
Resumo:
Resistant populations of the Bacteroides fragilis group bacteria (two reference ones and two isolated from human and Callithrix penicillata marmoset) were obtained by the gradient plate technique, to clindamycin, penicillin G, metronidazole and mercuric chloride. All the four tested strains were originaly susceptible to the four antimicrobial drugs at the breakpoint used in this study. MICs determination for the four cultures gave constant values for each antimicrobial, on the several steps by the gradient plate technique. The intestinal human B. fragilis strains showed three DNA bands, that could be representative of only two plasmids in the closed covalently circular (CCC) form with molecular weights of approximately 25 and 2.5 Md. The results do not permit an association between the presence of plasmid in the human strain with the susceptibility to the studied drugs. The four strains were ß-lactamase negative in the two methods used, and no particular chromosomal genetic resistance marker was demonstred. The resistance (MIC) observed, after contact with penicillin G and mercuric chloride, were two-fold in the four tested strains