926 resultados para Electro-acoustics
Resumo:
Improvements to the current state of the art in microfabricated cantilevers are investigated in order to realize enhanced functionality and increased versatility for use in ultrafast electrophoretic molecular sorting and delivery. Design rationale and fabrication process flow are described for six types of electro-thermal microcantilevers. Devices have been tailored for the process of separating mixtures of heterogeneous molecules into discrete detectable bands based on electrophoretic mobility, and delivering them to a conductive substrate using electric fields. Four device types include integrated heating elements capable of warming samples to catalyze reactions or cleaning the device for reuse. Similar devices have been shown to be capable of targeting temperatures between ambient conditions and the melting point of silicon, to within 0.1˚C precision or better. All microcantilevers types are equipped with a highly doped conductive silicon tip capable of interacting with a conductive substrate to deliver molecules under the presence of an electric field. Devices are equipped with additional electrodes to aid in sorting molecules on the surface of the probe end. Two designs contain two legs and one additional sorting electrode while four designs contain three legs and have two sorting electrodes. Devices having two sorting electrodes are designed to be capable of sorting three or more molecular species, a distinctive advancement in the state of the art. A detailed process flow of the fabrication process for all six electro-thermal cantilever designs are explained in detail.
Resumo:
Oceans environmental monitoring and seafloor exploitation need in situ sensors and optical devices (cameras, lights) in various locations and on various carriers in order to initiate and to calibrate environmental models or to operate underwater industrial process supervision. For more than 10 years Ifremer deploys in situ monitoring systems for various seawater parameters and in situ observation systems based on lights and HD Cameras. To be economically operational, these systems must be equipped with a biofouling protection dedicated to the sensors and optical devices used in situ. Indeed, biofouling, in less than 15 days [1] will modify the transducing interfaces of the sensors and causes unacceptable bias on the measurements provided by the in situ monitoring system. In the same way biofouling will decrease the optical properties of windows and thus altering the lighting and the quality fot he images recorded by the camera.
Resumo:
Generalidades anatómicas del musculo cardíaco -- Miocardio ventricular -- Génesis de la actividad -- eléctrica del corazón -- Señal eléctrica del corazón -- Representación vectorial -- El electrocardiograma --Intervalos y segmentos del electrocardiograma --Formas estándares de medición en el electrocardiograma -- Derivaciones bipolares -- Derivaciones monopolares --Posicionamiento adecuado de los electrodos-- Etapa de amplificación, filtrado y adaptación --Circuito de adecuación de la señal – Microcomputadora --Touchscreen display -- Shiel SD -- RTC (Real Time Clock) -- Thermal printer arduino -- Análisis de redes e interpretación del circuito de prueba -- Descripción, condiciones y resultados de la experimentación -- Desarrollo del dispositivo -- Interfaz de usuario -- Sistema de digitalización -- Sistema de Almacenamiento
Resumo:
The aim of this work is to simulate and optically characterize the piezoelectric performance of complementary metal oxide semiconductor (CMOS) compatible microcantilevers based on aluminium nitride (AlN) and manufactured at room temperature. This study should facilitate the integration of piezoelectric micro-electro-mechanical systems (MEMS) such as microcantilevers, in CMOS technology. Besides compatibility with standard integrated circuit manufacturing procedures, low temperature processing also translates into higher throughput and, as a consequence, lower manufacturing costs. Thus, the use of the piezoelectric properties of AlN manufactured by reactive sputtering at room temperature is an important step towards the integration of this type of devices within future CMOS technology standards. To assess the reliability of our fabrication process, we have manufactured arrays of free-standing microcantilever beams of variable dimension and studied their piezoelectric performance. The characterization of the first out-of-plane modes of AlN-actuated piezoelectric microcantilevers has been carried out using two optical techniques: laser Doppler vibrometry (LDV) and white light interferometry (WLI). In order to actuate the cantilevers, a periodic chirp signal in certain frequency ranges was applied between the device electrodes. The nature of the different vibration modes detected has been studied and compared with that obtained by a finite element model based simulation (COMSOL Multiphysics), showing flexural as well as torsional modes. The correspondence between theoretical and experimental data is reasonably good, probing the viability of this high throughput and CMOS compatible fabrication process. To complete the study, X-ray diffraction as well as d33 piezoelectric coefficient measurements were also carried out.
Resumo:
El objetivo del presente estudio fue analizar los cambios en el rendimiento en función de dos métodos de entrenamiento, el desarrollado mediante electro-estimulación muscular integral (EMI) frente a otro en el que se utilizaron bandas elásticas y que denominamos entrenamiento funcional con elásticos (EFE). La muestra estuvo compuesta por un grupo de diez (N=10) personas físicamente activas (23,04 ± 2,5 años). Se utilizó un diseño cuasi-experimental con medidas pre-post. Y fueron analizados los resultados de las pruebas: salto vertical con ayuda de brazos; y velocidad de desplazamiento en una carrera de ida y vuelta de 12 metros de distancia (6+6). Se realizó un análisis descriptivo de casos y medias. Y dado el tamaño de la muestra se calculó el tamaño del efecto, el cual fue bajo o moderado (d<0,5). Por último se compararon las diferencias de las medias de los grupos mediante la U de Mann Whitney, y las diferencias de las medias en función del tiempo (pre-post) mediante Friedman; en ambos casos los resultados no fueron significativos (p<0,5). En cuanto a los valores descriptivos del pre-post en ambos grupos: el grupo que entrenó con bandas elásticas obtuvo mejores resultados en ambas pruebas que el grupo que entrenó con EMI. En conclusión, el entrenamiento con bandas elásticas, a pesar de no ser significativo, parece mostrarse más efectivo que el entrenamiento con electro-estimulación muscular integral. Si bien, dadas las limitaciones del estudio estos datos hay que tomarlos con la pertinente cautela.
Resumo:
This thesis describes the development of the Sample Fetch Rover (SFR), studied for Mars Sample Return (MSR), an international campaign carried out in cooperation between the National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA). The focus of this document is the design of the electro-mechanical systems of the rover. After placing this work into the general context of robotic planetary exploration and summarising the state of the art for what concerns Mars rovers, the architecture of the Mars Sample Return Campaign is presented. A complete overview of the current SFR architecture is provided, touching upon all the main subsystems of the spacecraft. For each area, it is discussed what are the design drivers, the chosen solutions and whether they use heritage technology (in particular from the ExoMars Rover) or new developments. This research focuses on two topics of particular interest, due to their relevance for the mission and the novelty of their design: locomotion and sample acquisition, which are discussed in depth. The early SFR locomotion concepts are summarised, covering the initial trade-offs and discarded designs for higher traverse performance. Once a consolidated architecture was reached, the locomotion subsystem was developed further, defining the details of the suspension, actuators, deployment mechanisms and wheels. This technology is presented here in detail, including some key analysis and test results that support the design and demonstrate how it responds to the mission requirements. Another major electro-mechanical system developed as part of this work is the one dedicated to sample tube acquisition. The concept of operations of this machinery was defined to be robust against the unknown conditions that characterise the mission. The design process led to a highly automated robotic system which is described here in its main components: vision system, robotic arm and tube storage.
Resumo:
The work presented in this thesis deals with the investigation of new prototypes of molecular machines, based on rotaxane and pseudorotaxane architectures, by means of voltammetric and spectroscopic techniques. The discussion is divided in two parts. Part I concerns the investigation of electro-switchable molecular muscles, based on mechanically interlocked molecules. This study is performed on systems of increasing complexity, starting from [2]rotaxanes and arriving to polymers. In Chapters 3 and 4, [2]- and [3]rotaxanes, characterized by the presence of three stations for the macrocycle(s), are investigated. In both systems, the macrocycle(s) movement can be controlled through a combination of stimuli, resulting in a processive and directional motion. In Chapter 5, daisy chain rotaxanes, dimers of the [2]rotaxanes discussed in Chapter 3, are investigated. These systems can be switched between an extended and a contracted conformation, and they represent the monomeric units for the realization of polymeric molecular muscles. In Chapter 6, the properties of electro-switchable polymeric molecular muscles, composed by the daisy chains investigated in Chapter 5, are discussed. The repeating units of these poly-daisy chains contract and extend upon electrical stimulation, and this motion is expected to be transmitted to the polymer itself, resulting in an amplification of the effect. Part II concerns the investigation of rotaxanes and pseduorotaxanes based on heteroditopic calix[6]arenes and cationic guests. In Chapters 8 and 9, novel calix[6]arene macrocycles, functionalized with thiourea or dansyl units, and their related pseudorotaxanes are investigated. In both cases, the calix[6]arene functionalization adds new features to the pseudorotaxane. In Chapters 10 and 11, the influence of orientational isomerism on the properties of [2]- and [3]rotaxanes is investigated. The [3]rotaxanes discussed in Chapter 10 display similar properties, while the [2]rotaxanes described in Chapter 11, characterized by a calix[6]arene and a stilbazolium unit, exhibit distinct photophysical and photochemical properties.
Resumo:
The cardiomyocytes are very complex consisting of many interlinked non-linear regulatory mechanisms between electrical excitation and mechanical contraction. Thus given a integrated electromechanically coupled system it becomes hard to understand the individual contributor of cardiac electrics and mechanics under both physiological and pathological conditions. Hence, to identify the causal relationship or to predict the responses in a integrated system the use of computational modeling can be beneficial. Computational modeling is a powerful tool that provides complete control of parameters along with the visibility of all the individual components of the integrated system. The advancement of computational power has made it possible to simulate the models in a short timeframe, providing the possibility of increased predictive power of the integrated system. My doctoral thesis is focused on the development of electromechanically integrated human atrial cardiomyocyte model with proper consideration of feedforward and feedback pathways.
Resumo:
Given the rise in the emergence of new composite materials, their multifunctional properties, and possible applications in simple and complex structural components, there has been a need to unravel the characterization of these materials. The possibility of printing these conductive composite materials has opened a new area in the design of structural components which can conduct, transmit, and modulate electric signals with no limitation from complex geometry. Although several works have researched the behaviour of polymeric composites due to the immediate growth, however, the electrothermal behaviour of the material when subjected to varying AC applied voltage (Joule’s effect) has not been thoroughly researched. This study presents the characterization of the electrothermal behaviour of conductive composites of a polylactic acid matrix reinforced with conductive carbon black particles (CB-PLA). An understanding of this behaviour would contribute to the improved work in additive manufacturing of functional electro-mechanical conductive materials with potential application in energy systems, bioelectronics, etc. In this study, the electrothermal interplay is monitored under applied AC voltage, varying lengths, and filament printing orientations (longitudinal, oblique, and transverse). Each sample was printed using the fused deposition modeling technique such that each specimen has three different lengths (1L, 2L, 2.75L). To this end, deductions were made on properties that affect composite’s efficiency and life expectancy. The result of this study shows a great influence of printing orientation on material properties of 3D printed conductive composites of CB-PLA. The result also identifies the contribution of AC applied voltage to composites' stabilization time. This knowledge is important to provide experimental background for components' electrothermal interplay, estimate possible degradation and operating limits of composite structures when used in applications.
Resumo:
Bariatric surgery is considered an effective method for sustained weight loss, but may cause various nutritional complications. The aim of this study was to evaluate the nutritional status of minerals and vitamins, food consumption, and to monitor physiologic parameters in patients with obesity before and 6 months after Roux-en-Y gastric bypass surgery (RYGB). Thirty-six patients who had undergone RYGB were prospectively evaluated before and 6 months after surgery. At each phase their weight, height, body mass index (BMI), Electro Sensor Complex (ES Complex) data, food consumption, and total protein serum levels, albumin, prealbumin, parathyroid hormone (PTH), zinc (Zn), B12 vitamin (VitB12), iron (Fe), ferritin, copper (Cu), ionic calcium (CaI), magnesium (Mg), and folic acid were assessed. The mean weight loss from baseline to 6 months after surgery was 35.34±4.82%. Markers of autonomic nervous system balance (P<.01), stiffness index (P<.01), standard deviation of normal-to-normal R-R intervals (SDNN) (P<.01), and insulin resistance (P<.001) were also improved. With regard to the micronutrients measured, 34 patients demonstrated some kind of deficiency. There was a high percentage of Zn deficiency in both pre- (55.55%) and postoperative (61.11%) patients, and 33.33% of the patients were deficient in prealbumin postoperatively. The protein intake after 6 months of surgery was below the recommended intake (<70 g/d) for 88.88% of the patients. Laboratory analyses demonstrated an average decrease in total protein (P<.05), prealbumin (P = .002), and PTH (P = .008) between pre- and postsurgery, and a decrease in the percentage of deficiencies for Mg (P<.05), CaI (P<.05), and Fe (P = .021). Despite improvements in the autonomic nervous system balance, stiffness index markers and insulin resistance, we found a high prevalence of hypozincemia at 6 months post-RYGB. Furthermore, protein supplements were needed to maintain an adequate protein intake up to 6 months postsurgery.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Neste artigo apresentamos uma descrição geral da física do violino, analisando os conceitos que lhes dão sustentação física e que revelam toda a riqueza e o potencial pedagógico do assunto. Destacamos as contribuições de físicos como Helmholtz, Savart, Raman e Saunders no esforço para descrever a vibração produzida pelo arco nas cordas, e por compreender as propriedades acústicas do instrumento. Descrevemos a função de cada uma das componentes do instrumento e discutimos a importância dos modos normais de vibração dos tampos e do cavalete na resposta acústica do violino. A ressonância acústica da caixa do violino (ressonância de Helmholtz) será discutida fazendo-se um paralelo entre osciladores mecânico, elétrico e acústico. Discutiremos a resposta acústica do violino e descreveremos a produção de seu som caraterístico, que resulta da forma de onda originada pela excitação das cordas pelo arco, influenciada pelas vibrações e ressonâncias do corpo do violino, seus tampos e o cavalete.