910 resultados para Electric wiring -- Equipment and supplies


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Ce6-xYxMoO15-delta solid solution with fluorite-related structure have been characterized by differential thermal analysis/thermogravimetry (DTA/TG), X-ray diffraction (XRD), IR, Raman, scanning electric microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) methods. The electric conductivity of samples is investigated by Ac impedance spectroscopy. An essentially pure oxide-ion conductivity of the oxygen-deficiency was observed in pure argon, oxygen and air. The highest oxygen-ion conductivity was found in Ce5.5Y0.5MoO15-delta ranging from 5.9 X 10(-5)(S cm(-1)) at 300 degrees C to 1.3 X 10(-2)(S cm(-1)) at 650 degrees C, respectively. The oxide-ion conductivities remained stable over 80 h-long test at 800 degrees C. These properties suggested that significant oxide-ionic conductivity exists in these materials at moderately elevated temperatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A modified tapping mode of the atomic force microscope (AFM) was introduced for manipulation, dissection, and lithography. By sufficiently decreasing the amplitude of AFM tip in the normal tapping mode and adjusting the setpoint, the tip-sample interaction can be efficiently controlled. This modified tapping mode has some characteristics of the AFM contact mode and can be used to manipulate nanoparticles, dissect biomolecules, and make lithographs on various surfaces. This method did not need any additional equipment and it can be applied to any AFM system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present paper reports the synthesis of glycidyl monoether of 4-[(p-nitrophenyl) azo] phenol (GMNA) and crosslinking reaction of GMNA with hexamethylene diisocyanate biuret (HDIB). The Tg of crosslinked polymer was investigated by DSC. The orientation and stability of the poled and crosslinked polymer film were studied by UV-Vis spectra and Maker fringe method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The difference between the Mossbauer parameters for EuBa2Cu3O7-x with dc electric current and those without dc electric current at 83 K has been observed. The change in isomer shift, electric quadrupole splitting and the asymmetry parameter of the electric field gradient at the Eu-151 nucleus may be caused by the movement of a mass of conduction electrons along a certain direction in the EuBa2Cu3O7-x crystal with a layered structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Vision Flashes are informal working papers intended primarily to stimulate internal interaction among participants in the A.I. Laboratory's Vision and Robotics group. Many of them report highly tentative conclusions or incomplete work. Others deal with highly detailed accounts of local equipment and programs that lack general interest. Still others are of great importance, but lack the polish and elaborate attention to proper referencing that characterizes the more formal literature. Nevertheless, the Vision Flashes collectively represent the only documentation of an important fraction of the work done in machine vision and robotics. The purpose of this report is to make the findings more readily available, but since they are not revised as presented here, readers should keep in mind the original purpose of the papers!

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anesthesia providers in low-income countries may infrequently provide regional anesthesia techniques for obstetrics due to insufficient training and supplies, limited manpower, and a lack of perceived need. In 2007, Kybele, Inc. began a 5-year collaboration in Ghana to improve obstetric anesthesia services. A program was designed to teach spinal anesthesia for cesarean delivery and spinal labor analgesia at Ridge Regional Hospital, Accra, the second largest obstetric unit in Ghana. The use of spinal anesthesia for cesarean delivery increased significantly from 6% in 2006 to 89% in 2009. By 2012, >90% of cesarean deliveries were conducted with spinal anesthesia, despite a doubling of the number performed. A trial of spinal labor analgesia was assessed in a small cohort of parturients with minimal complications; however, protocol deviations were observed. Although subsequent efforts to provide spinal analgesia in the labor ward were hampered by anesthesia provider shortages, spinal anesthesia for cesarean delivery proved to be practical and sustainable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

© 2015 Human Kinetics, Inc.Background: Young children's physical activity (PA) is influenced by their child care environment. This study assessed PA practices in centers from Massachusetts (MA) and Rhode Island (RI), compared them to best practice recommendations, and assessed differences between states and center profit status. We also assessed weather-related practices. Methods: Sixty percent of MA and 54% of RI directors returned a survey, for a total of 254. Recommendations were 1) daily outdoor play, 2) providing outdoor play area, 3) limiting fixed play structures, 4) variety of portable play equipment, and 5) providing indoor play area. We fit multivariable linear regression models to examine adjusted associations between state, profit status, PA, and weather-related practices. Results: MA did not differ from RI in meeting PA recommendations (β = 0.03; 0.15, 0.21; P = .72), but MA centers scored higher on weather-related practices (β = 0.47; 0.16, 0.79; P = .004). For-profit centers had lower PA scores compared with nonprofits (β = -0.20; 95% CI: -0.38, -0.02; P = .03), but they did not differ for weather (β = 0.12; -0.19, 0.44; P = .44). Conclusions: More MA centers allowed children outside in light rain or snow. For-profit centers had more equipment-both fixed and portable. Results from this study may help inform interventions to increase PA in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The newly formed Escape and Evacuation Naval Authority regulates the provision of abandonment equipment and procedures for all Ministry of Defence Vessels. As such, it assures that access routes on board are evaluated early in the design process to maximize their efficiency and to eliminate, as far as possible, any congestion that might occur during escape. This analysis can be undertaken using a computer-based simulation for given escape scenarios and replicates the layout of the vessel and the interactions between each individual and the ship structure. One such software tool that facilitates this type of analysis is maritimeEXODUS. This tool, through large scale testing and validation, emulates human shipboard behaviour during emergency scenarios; however it is largely based around the behaviour of civilian passengers and fixtures and fittings of merchant vessels. Hence there existed a clear requirement to understand the behaviour of well-trained naval personnel as opposed to civilian passengers and be able to model the fixtures and fittings that are exclusive to warships, thus allowing improvements to both maritimeEXODUS and other software products. Human factor trials using the Royal Navy training facilities at Whale Island, Portsmouth were recently undertaken to collect data that improves our understanding of the aforementioned differences. It is hoped that this data will form the basis of a long-term improvement package that will provide global validation of these simulation tools and assist in the development of specific Escape and Evacuation standards for warships. © 2005: Royal Institution of Naval Architects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure for estimating total organochlorine pesticide and PCB residue in seal blubber at concentrations of greater than 1μg g-1 of lipid is described. Lipid is cleaned up by alumina column chromatography, and the halogen concentration of the resulting hexane eluace is determined by combustion and microcoulometry. Results are similar to those obtained by gas chromatographic analysis and can be used to interpolate between results so obtained when data on specific organochlorine compounds is not required for each sample. The organochlorine residues recovered in this manner did not constitute all the halogen determined by combustion and microcoulometry of seal lipid. Analysis by the total halogen procedure was 2.5 tunes faster than the rate achieved with a combination of liquid and gas chromatography operated manually; the requirements for laboratory equipment and space for sample preparation are reduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The US National Oceanic and Atmospheric Administration (NOAA) Fisheries Continuous Plankton Recorder (CPR) Survey has sampled four routes: Boston–Nova Scotia (1961–present), New York toward Bermuda (1976–present), Narragansett Bay–Mount Hope Bay–Rhode Island Sound (1998–present) and eastward of Chesapeake Bay (1974–1980). NOAA involvement began in 1974 when it assumed responsibility for the existing Boston–Nova Scotia route from what is now the UK's Sir Alister Hardy Foundation for Ocean Science (SAHFOS). Training, equipment and computer software were provided by SAHFOS to ensure continuity for this and standard protocols for any new routes. Data for the first 14 years of this route were provided to NOAA by SAHFOS. Comparison of collection methods; sample processing; and sample identification, staging and counting techniques revealed near-consistency between NOAA and SAHFOS. One departure involved phytoplankton counting standards. This has since been addressed and the data corrected. Within- and between-survey taxonomic and life-stage names and their consistency through time were, and continue to be, an issue. For this, a cross-reference table has been generated that contains the SAHFOS taxonomic code, NOAA taxonomic code, NOAA life-stage code, National Oceanographic Data Center (NODC) taxonomic code, Integrated Taxonomic Information System (ITIS) serial number and authority and consistent use/route. This table is available for review/use by other CPR surveys. Details of the NOAA and SAHFOS comparison and analytical techniques unique to NOAA are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energies of the 54 levels belonging to the (1s(2)2s(2)2p(6)) 3s(2)3p(5), 3s3p(6), 3s(2)3p(4)3d and 3s3p(5)3d configurations of Fe X have been calculated using the GRASP code of Dyall et al. (1989). Additionally, radiative rates, oscillator strengths, and line strengths are calculated for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) transitions among these levels. Comparisons are made with results available in the literature, and the accuracy of the data is assessed. Our energy levels are estimated to be accurate to better than 3%, whereas results for other parameters are probably accurate to better than 20%. Additionally, the agreement between measured and calculated lifetimes is better than 10%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energies for 524 levels of Ar XIII, 460 levels of Ar XIV and 156 levels of Ar XV have been calculated using the GRASP code of Dyall et al. (1989). Additionally, radiative rates, oscillator strengths, and line strengths are calculated for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) transitions among these levels. Comparisons are made with the limited results available in the literature, and the accuracy of the data is assessed. Our energy levels are estimated to be accurate to better than 1%, whereas results for other parameters are probably accurate to better than 20%. Additionally, the level lifetimes derived from our radiative rates are in excellent agreement with measured values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energies of the 700 lowest levels in Fe XX have been obtained using the multiconfiguration Dirac-Fock method. Configuration interaction method on the basis set of transformed radial orbitals with variable parameters taking into account relativistic corrections in the Breit-Pauli approximation was used to crosscheck our presented results. Transition probabilities, oscillator and line strengths are presented for electric dipole (E1), electric quadrupole (E2) and magnetic dipole (M1) transitions among these levels. The total radiative transition probabilities from each level are also provided. Results are compared with data compiled by NIST and with other theoretical work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy levels and the corresponding transition probabilities for allowed and forbidden transitions among the levels of the ground configuration and first 23 excited configurations of fluorine-like Fe XVIII have been calculated using the multiconfigurational Dirac-Fock GRASP code. A total of 379 lowest bound levels of Fe XVIII is presented, and the energy levels are identified in spectroscopic notations. Transition probabilities, oscillator strengths and line strengths for electric dipole (E1), electric quadrupole (E2) and magnetic dipole (M1) transitions among these 379 levels are also presented. The calculated energy levels and transition probabilities are compared with experimental data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiconfigurational Dirac-Fock calculations are reported for 656 energy levels and the 214 840 electric dipole (E I), electric quadrupole (E2) and magnetic dipole (M1) transition probabilities in oxygen-like Fe xix. The spectroscopic notations as well as the total transition probabilities from each energy level are provided. Good agreement is found with data compiled by NIST.