1000 resultados para Electric post
Resumo:
In order to investigate the pathogenicity of the virus strain GOI 4191 that was isolated from a fatal adverse event after yellow fever virus (YFV) vaccination, an experimental assay using hamsters (Mesocricetus auratus) as animal model and YFV 17DD vaccine strain as virus reference was accomplished. The two virus strains were inoculated by intracerebral, intrahepatic and subcutaneous routes. The levels of viremia, antibody response, and aminotransferases were determined in sera; while virus, antigen and histopathological changes were determined in the viscera. No viremia was detected for either strain following infection; the immune response was demonstrated to be more effective to strain GOI 4191; and no significant aminotransferase levels alterations were detected. Strain GOI 4191 was recovered only from the brain of animals inoculated by the IC route. Viral antigens were detected in liver and brain by immunohistochemical assay. Histothological changes in the viscera were characterized by inflammatory infiltrate, hepatocellular necrosis, and viral encephalitis. Histological alterations and detection of viral antigen were observed in the liver of animals inoculated by the intrahepatic route. These findings were similar for both strains used in the experiment; however, significant differences were observed from those results previously reported for wild type YFV strains.
Resumo:
Paper presented at the Colloquium Gerpisa 2013, Paris (http://gerpisa.org/node/2085), Session n°: 19 New kinds of mobility: old and new business models
Resumo:
Na sequência do panorama económico atual, existe cada vez mais uma tendência de redução de custos e de, em simultâneo, obter a eficiência energética desejada, mais concretamente no setor dos edifícios, uma vez que este tem um peso bastante considerável nos consumos totais em Portugal e na Europa. Existem variadas formas de atuar neste sentido nomeadamente ao nível dos equipamentos e sistemas instalados, bem como, nos hábitos e comportamentos dos ocupantes. Com esse intuito, muitas empresas têm desenvolvido mecanismos ou formas de minimizar os gastos, nomeadamente em termos de consumos elétricos. Dentro dos possíveis caminhos para se alcançar esse objetivo, surgem os sistemas de monitorização e os sistemas de gestão técnica centralizada. O objetivo de reduzir a discrepância entre a fatura que se paga pela eletricidade e o que realmente consiste numa necessidade de consumo é atualmente uma preocupação real. Desta forma, o desenvolvimento de soluções com capacidade para garantir a redução do erro na tomada de decisão bem como as que tornem possível o acompanhamento do desempenho de toda a instalação em detalhe e em tempo real são áreas nas quais se tem e se vai continuar a investir. É por isso, realmente importante, perceber onde e porquê se consome mais e é um desafio alterar esse panorama e continuar a realizar a monitorização dos registos. Para tal, a empresa Schneider Electric tem instaladas estações de medida, mais concretamente analisadores de energia, nos seus quadros elétricos, de forma a conseguir percecionar os consumos de forma mais detalhada e direcionada, ou seja, permitindo visualizar dados de todas as frações do piso. 281 Esta dissertação tem como objetivo a avaliação dos consumos de eletricidade de forma detalhada, tendo como objeto de estudo o edifício onde está sediada a empresa Schneider Eletric, de forma detalhada e a posterior identificação de hábitos ou fatores que influenciem os mesmos da forma não pretendida. Tem ainda o objetivo de avaliar o comportamento da técnica solar passiva utilizada no referido edifício. Desta forma será possível saber, não só o perfil de consumos e respetivos impactos bem como sugerir possíveis ajustes que levem a uma maior eficiência energética. Os resultados deste estudo deverão permitir às pessoas responsáveis pela entidade tomar decisões assentes em informação concreta e detalhada.
Resumo:
Zero valent iron nanoparticles (nZVI) are considered very promising for the remediation of contaminated soils and groundwaters. However, an important issue related to their limited mobility remains unsolved. Direct current can be used to enhance the nanoparticles transport, based on the same principles of electrokinetic remediation. In this work, a generalized physicochemical model was developed and solved numerically to describe the nZVI transport through porous media under electric field, and with different electrolytes (with different ionic strengths). The model consists of the Nernst–Planck coupled system of equations, which accounts for the mass balance of ionic species in a fluid medium, when both the diffusion and electromigration of the ions are considered. The diffusion and electrophoretic transport of the negatively charged nZVI particles were also considered in the system. The contribution of electroosmotic flow to the overall mass transport was included in the model for all cases. The nZVI effective mobility values in the porous medium are very low (10−7–10−4 cm2 V−1 s−1), due to the counterbalance between the positive electroosmotic flow and the electrophoretic transport of the negatively charged nanoparticles. The higher the nZVI concentration is in the matrix, the higher the aggregation; therefore, low concentration of nZVI suspensions must be used for successful field application.
Resumo:
As the financial crisis hit the Portuguese banks, the profitability of the whole sector squeezed to historical minimums. Reinventing the banking business model in the post-crisis context is an overriding issue to achieve sustainable profits and a low cost-to-income ratio. We propose banks to adopt a true multichannel approach, proceeding to a branch network reformatting and a relocation of services to online channels; adopt a true customer-centric approach and reduce the product and services portfolio complexity; finally, industrialize operations and rationalize the structure. With these measures in place, Portuguese banks will become leaner and more efficient, aspiring to a cost-to-income ratio below 45%.
Resumo:
Due to global warming and shrinking fossil fuel resources, politics as well as society urge for a reduction of green house gas (GHG) emissions. This leads to a re-orientation towards a renewable energy sector. In this context, innovation and new technologies are key success factors. Moreover, the renewable energy sector has entered a consolidation stage, where corporate investors and mergers and acquisitions (M&A) gain in importance. Although both M&A and innovation in the renewable energy sector are important corporate strategies, the link between those two aspects has not been examined before. The present thesis examines the research question how M&A influence the acquirer’s post-merger innovative performance in the renewable energy sector. Based on a framework of relevant literature, three hypotheses are defined. First, the relation between non-technology oriented M&A and post-merger innovative performance is discussed. Second, the impact of absolute acquired knowledge on postmerger innovativeness is examined. Third, the target-acquirer relatedness is discussed. A panel data set of 117 firms collected over a period of six years has been analyzed via a random effects negative binomial regression model and a time lag of one year. The results support a non-significant, negative impact of non-technology M&A on postmerger innovative performance. The applied model did not support a positive and significant impact of absolute acquired knowledge on post-merger innovative performance. Lastly, the results suggest a reverse relation than postulated by Hypothesis 3. Targets from the same industry significantly and negatively influence the acquirers’ innovativeness.
Resumo:
Introduction Surgical site infections (SSIs) often manifest after patients are discharged and are missed by hospital-based surveillance. Methods We conducted a case-reference study nested in a prospective cohort of patients from six surgical specialties in a teaching hospital. The factors related to SSI were compared for cases identified during the hospital stay and after discharge. Results Among 3,427 patients, 222 (6.4%) acquired an SSI. In 138 of these patients, the onset of the SSI occurred after discharge. Neurological surgery and the use of steroids were independently associated with a greater likelihood of SSI diagnosis during the hospital stay. Conclusions Our results support the idea of a specialty-based strategy for post-discharge SSI surveillance.
Resumo:
Epstein-Barr virus (EBV)-related post-transplant lymphoproliferative disease (PTLD) is one of the most serious complications associated with solid organ and hematopoietic stem cell transplantation. PTLD is most frequently seen with primary EBV infection post-transplant, a common scenario for pediatric solid organ recipients. Risk factors for infection or reactivation of EBV following solid organ transplant are stronger immunosuppressive therapy regimens, and being seronegative for receptor. For hematopoietic stem cell transplantation, the risk factors relate to the type of transplant, human leukocyte antigen disparity, the use of stronger immunosuppressants, T-cell depletion, and severe graft-versus-host disease. Mortality is high, and most frequent in patients who develop PTLD in the first six months post-transplant. The primary goal of this article is to provide an overview of the clinical manifestations, diagnosis, accepted therapies, and management of EBV infection in transplant recipients, and to suggest that the adoption of monitoring protocols could contribute to a reduction in related complications.
Resumo:
INTRODUCTION : Bacterial translocation is the invasion of indigenous intestinal bacteria through the gut mucosa to normally sterile tissues and internal organs. Schistosomiasis may cause alterations in the immune system and damage to the intestines, portal system and mesenteric lymph nodes. This study investigated bacterial translocation and alterations in the intestinal microbiota and mucosa in schistosomiasis and splenectomized mice. METHODS : Forty female 35-day-old Swiss Webster mice were divided into the following four groups with 10 animals each: schistosomotic (ESF), splenectomized schistosomotic (ESEF), splenectomized (EF) and control (CF). Infection was achieved by introduction of 50 Schistosoma mansoni (SLM) cercariae through the skin. At 125 days after birth, half of the parasitized and unparasitized mice were subjected to splenectomy. Body weights were recorded for one week after splenectomy; then, the mice were euthanized to study bacterial translocation, microbiota composition and intestinal morphometry. RESULTS : We observed significant reductions in the weight increases in the EF, ESF and ESEF groups. There were increases of at least 1,000 CFU of intestinal microbiota bacteria in these groups compared with the CF. The EF, ESF and ESEF mice showed decreases in the heights and areas of villi and the total villus areas (perimeter). We observed frequent co-infections with various bacterial genera. CONCLUSIONS : The ESEF mice showed a higher degree of sepsis. This finding may be associated with a reduction in the immune response associated with the absence of the spleen and a reduction in nutritional absorption strengthened by both of these factors (Schistosoma infection and splenectomy).
Resumo:
The design of anchorage blisters of internal continuity post-tensioning tendons of bridges built by the cantilever method, presents some peculiarities, not only because they are intermediate anchorages but also because these anchorages are located in blisters, so the prestressing force has to be transferred from the blister the bottom slab and web of the girder. The high density of steel reinforcement in anchorage blisters is the most common reason for problems with concrete cast in situ, resulting in zones with low concrete compacity, leading to concrete crushing failures under the anchor plates. A solution may involve improving the concrete compression and tensile strength. To meet these requirements a high-performance fibre reinforced self-compacting mix- ture (HPFRC) was used in anchorage corner blisters of post-tensioning tendons, reducing the concrete cross-section and decreasing the reinforcement needed. To assess the ultimate capacity and the adequate serviceability of the local anchorage zone after reducing the minimum concrete cross-section and the confining reinforcement, specified by the anchorage device supplier for the particular tendon, load transfer tests were performed. To investigate the behaviour of anchorage blisters regarding the transmission of stresses to the web and the bottom slab of the girder, and the feasibility of using high performance concrete only in the blister, two half scale models of the inferior corner of a box girder existing bridge were studied: a reference specimen of ordinary reinforced concrete and a HPFRC blister specimen. The design of the reinforcement was based in the tensile forces obtained on strut-and-tie models. An experimental program was carried out to assess the models used in design and to study the feasibility of using high performance concrete only in the blister, either with casting in situ, or with precast solutions. A non-linear finite element analysis of the tested specimens was also performed and the results compared.
Resumo:
Scarcity of fuels, changes in environmental policy and in society increased the interest in generating electric energy from renewable energy sources (RES) for a sustainable energy supply in the future. The main problem of RES as solar and wind energy, which represent a main pillar of this transition, is that they cannot supply constant power output. This results inter alia in an increased demand of backup technologies as batteries to assure electricity system safety. The diffusion of energy storage technologies is highly dependent on the energy system and transport transition pathways which might lead to a replacement or reconfiguration of embedded socio-technical practices and regimes (by creating new standards or dominant designs, changing regulations, infrastructure and user patterns). The success of this technology is dependent on hardly predictable future technical advances, actor preferences, development of competing technologies and designs, diverging interests of actors, future cost efficiencies, environmental performance, the evolution of market demand and design and evolution of our society.
Resumo:
The frequency of electric organ discharges (EOD) of a gymnotiform fish of "pulse" frequency (40-100 Hz) from South America - Ramphicthys rostratuswas studied. The animals were settled in pairs in a aquarium and thus observed: variation in EOD frequency had at least two components: one more positively correlated with temperature, another less positively correlated due to social interaction.
Resumo:
O fim da Guerra Fria é um caso inédito de mudança pacífica da estrutura internacional, em que os Estados Unidos e a União Soviética transcendem a divisão bipolar para decidir os termos da paz no quadro das instituições que definem o modelo de ordenamento multilateral, consolidando a sua legitimidade. Nesse contexto, ao contrário dos casos precedentes de reconstrução internacional no fim de uma guerra hegemónica, o novo sistema do post-Guerra Fria, caracterizado pela unipolaridade, pela regionalização e pela homogeneização, forma-se num quadro de continuidade institucional. A ordem política do post-Guerra Fria é um sistema misto em que as tensões entre a hierarquia unipolar e a anarquia multipolar, a integração global e a fragmentação regional e a homogeneidade e a heterogeneidade política, ideológica e cultural condicionam as estratégias das potências. As crises internacionais vão pôr à prova a estabilidade da nova ordem e a sua capacidade para garantir mudanças pacíficas. A primeira década do post-Guerra Fria mostra a preponderância dos Estados Unidos e a sua confiança crescente, patente nas Guerras do Golfo Pérsico e dos Balcãs, bem como na crise dos Estreitos da Formosa. A reacção aos atentados do "11 de Setembro" revela uma tentação imperial da potência unipolar, nomeadamente com a invasão do Iraque, que provoca uma crise profunda da comunidade de segurança ocidental. A vulnerabilidade do centro da ordem internacional é confirmada pela crise constitucional europeia e pela crise financeira global. Essas crises não alteram a estrutura de poder mas aceleram a erosão da ordem multilateral e criam um novo quadro de possibilidades para a evolução internacional, que inclui uma escalada dos conflitos num quadro de multipolaridade regional, uma nova polarização entre as potências democráticas conservadoras e uma coligação revisionista autoritária, bem como a restauração de um concerto entre as principais potências internacionais.
Resumo:
Adding fibres to concrete provides several advantages, especially in terms of controlling the crack opening width and propagation after the cracking onset. However, distribution and orientation of the fibres toward the active crack plane are significantly important in order to maximize its benefits. Therefore, in this study, the effect of the fibre distribution and orientation on the post-cracking tensile behaviour of the steel fibre reinforced self-compacting concrete (SFRSCC) specimens is investigated. For this purpose, several cores were extracted from distinct locations of a panel and were subjected to indirect (splitting) and direct tensile tests. The local stress-crack opening relationship (σ-w) was obtained by modelling the splitting tensile test under the finite element framework and by performing an Inverse Analysis (IA) procedure. Afterwards the σ-w law obtained from IA is then compared with the one ascertained directly from the uniaxial tensile tests. Finally, the fibre distribution/orientation parameters were determined adopting an image analysis technique.
Resumo:
This paper presents an on-board bidirectional battery charger for Electric Vehicles (EVs), which operates in three different modes: Grid-to- Vehicle (G2V), Vehicle-to-Grid (V2G), and Vehicle-to-Home (V2H). Through these three operation modes, using bidirectional communications based on Information and Communication Technologies (ICT), it will be possible to exchange data between the EV driver and the future smart grids. This collaboration with the smart grids will strengthen the collective awareness systems, contributing to solve and organize issues related with energy resources and power grids. This paper presents the preliminary studies that results from a PhD work related with bidirectional battery chargers for EVs. Thus, in this paper is described the topology of the on-board bidirectional battery charger and the control algorithms for the three operation modes. To validate the topology it was developed a laboratory prototype, and were obtained experimental results for the three operation modes.