862 resultados para ELECTROCHEMICAL-DFT CORRELATION
Resumo:
The development and application of a polyaniline/carbon nanotube (CNT) cyclodextrin matrix (PANI-β-CD/MWCNT)-based electrochemical sensor for the quantitative determination of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA) and its main transformation product 4-chloro-2-methylphenol in natural waters are described. A simple cyclic voltammetry-based electrochemical methodology, in phosphate buffer solution at pH 6.0, was used to develop a method to determine both MCPA and 4-chloro-2-methylphenol, without any previous extraction or derivatization steps. A linear concentration range (10 to 50 μmol L−1) and detection limits of 1.1 and 1.9 μmol L−1, respectively, were achieved using optimized cyclic voltammetric parameters. The proposed method was successfully applied to the determination of MCPA and 4-chloro-2-methylphenol in natural water samples with satisfactory recoveries (94 to 107 %) and in good agreement with the results obtained by an established high-performance liquid chromatography technique, no significant differences being found between the methods. Interferences from ionic species and other herbicides used for broad-leaf weed control were shown to be small. The newly developed methodology was also successfully applied to MCPA photodegradation environmental studies.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
The question of whether HIV-1 RNA in cerebrospinal fluid (CSF) is derived from viral replication in the central nervous system or simply reflects the transit of infected lymphocytes from the blood compartment has long been a matter of debate. Some studies found no correlation between CSF and plasma viral load, whereas others did. The lack of a correlation between the two compartments suggests that the presence of HIV-1 RNA is not simply due to the passive passage of the virus from blood to CSF but rather due to intrathecal replication. To evaluate the correlation between plasma and CSF HIV-1 RNA levels and to identify situations in which there is no correlation between the two compartments, seventy patients were prospectively studied. The association between CSF and plasma viral load was evaluated in the total population and in subgroups of patients with similar characteristics. A correlation between the CSF and plasma compartments was observed for patients undergoing highly active antiretroviral therapy (HAART), those with a CD4 T lymphocyte count lower than 200 cells/mm³, and those with increased CSF protein content. On the other hand, no correlation was observed for patients without adequate virological control, who had a CD4 count higher than 200 cells/mm³ and who did not use HAART. The correlation between the two compartments observed in some patients suggests that CSF HIV-1 RNA levels may reflect plasma levels in these subjects. In contrast, the lack of a correlation between the two compartments in patients who were not on HAART and who had normal CSF proteins and a poor virological control possibly indicates compartmentalization of the virus in CSF and, consequently, plasma-independent intrathecal viral replication.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia de Materiais
Resumo:
Nos últimos anos tem-se assistido à introdução de novos dispositivos de medição da poluição do ar baseados na utilização de sensores de baixo custo. A utilização menos complexa destes sistemas, possibilita a obtenção de dados com elevada resolução temporal e espacial, abrindo novas oportunidades para diferentes metodologias de estudos de monitorização da poluição do ar. Apesar de apresentarem capacidades analíticas distantes dos métodos de referência, a utilização destes sensores tem sido sugerida e incentivada pela União Europeia no âmbito das medições indicativas previstas na Diretiva 2008/50/CE, com uma incerteza expandida máxima de 25%. O trabalho desenvolvido no âmbito da disciplina de Projeto consistiu na escolha, caracterização e utilização em medições reais de um sensor de qualidade do ar, integrado num equipamento protótipo desenvolvido com esse fim, visando obtenção uma estimativa da incerteza de medição associada à utilização deste dispositivo através da aplicação da metodologia de demonstração de equivalência de métodos de medição de qualidade do ar definida pela União Europeia. A pesquisa bibliográfica realizada permitiu constatar que o monóxido de carbono é neste momento o parâmetro de qualidade do ar que permite ser medido de forma mais exata através da utilização de sensores, nomeadamente o sensor eletroquímico da marca Alphasense, modelo COB4, amplamente utilizado em projetos de desenvolvimento neste cotexto de monitorização ambiental. O sensor foi integrado num sistema de medição com o objetivo de poder ser utlizado em condições de autonomia de fornecimento de energia elétrica, aquisição interna dos dados, tendo em consideração ser o mais pequeno possível e de baixo custo. Foi utlizado um sistema baseado na placa Arduino Uno com gravação de dados em cartão de memória SD, baterias e painel solar, permitindo para além do registo das tensões elétricas do sensor, a obtenção dos valores de temperatura, humidade relativa e pressão atmosférica, com um custo global a rondar os 300 euros. Numa primeira fase foram executados um conjunto de testes laboratoriais que permitiram a determinação de várias características de desempenho em dois sensores iguais: tempo de resposta, a equação modelo do sensor, avaliação da repetibilidade, desvio de curto e longo termo, interferência da temperatura e histerese. Os resultados demonstraram um comportamento dos sensores muito linear, com um tempo de resposta inferior a um minuto e com uma equação modelo do sensor dependente da variação da temperatura. A estimativa da incerteza expandida laboratorial ficou, para ambos os sensores, abaixo dos 10%. Após a realização de duas campanhas reais de medição de CO em que os valores foram muito baixos, foi realizada uma campanha de quinze dias num parque de estacionamento subterrâneo que permitiu a obtenção de concentrações suficientemente elevadas e a comparação dos resultados dos sensores com o método de referência em toda a gama de medição (0 a 12 mol.mol-1). Os valores de concentração obtidos pelos dois sensores demonstraram uma excelente correlação com o método de referência (r2≥0,998), obtendo-se resultados para a estimativa da incerteza expandida de campo inferiores aos obtidos para a incerteza laboratorial, cumprindo o objetivo de qualidade de dados definido para as medições indicativas de incerteza expandida máxima de 25%. Os resultados observados durante o trabalho realizado permitiram confirmar o bom desempenho que este tipo de sensor pode ter no âmbito de medições de poluição do ar com um caracter mais indicativo.
Resumo:
Ligand K-edge XAS of an [Fe3S4]0 model complex is reported. The pre-edge can be resolved into contributions from the í2Ssulfide, í3Ssulfide, and Sthiolate ligands. The average ligand-metal bond covalencies obtained from these pre-edges are further distributed between Fe3+ and Fe2.5+ components using DFT calculations. The bridging ligand covalency in the [Fe2S2]+ subsite of the [Fe3S4]0 cluster is found to be significantly lower than its value in a reduced [Fe2S2] cluster (38% vs 61%, respectively). This lowered bridging ligand covalency reduces the superexchange coupling parameter J relative to its value in a reduced [Fe2S2]+ site (-146 cm-1 vs -360 cm-1, respectively). This decrease in J, along with estimates of the double exchange parameter B and vibronic coupling parameter ì2/k-, leads to an S ) 2 delocalized ground state in the [Fe3S4]0 cluster. The S K-edge XAS of the protein ferredoxin II (Fd II) from the D. gigas active site shows a decrease in covalency compared to the model complex, in the same oxidation state, which correlates with the number of H-bonding interactions to specific sulfur ligands present in the active site. The changes in ligand-metal bond covalencies upon redox compared with DFT calculations indicate that the redox reaction involves a two-electron change (one-electron ionization plus a spin change of a second electron) with significant electronic relaxation. The presence of the redox inactive Fe3+ center is found to decrease the barrier of the redox process in the [Fe3S4] cluster due to its strong antiferromagnetic coupling with the redox active Fe2S2 subsite.
Resumo:
Biochem. J. (2011) 438,485–494 doi:10.1042/BJ20110836
Resumo:
BACKGROUND: Both primary and secondary gynaecological neuroendocrine (NE) tumours are uncommon, and the literature is scarce concerning their imaging features. METHODS: This article reviews the epidemiological, clinical and imaging features with pathological correlation of gynaecological NE tumours. RESULTS: The clinical features of gynaecological NE tumours are non-specific and depend on the organ of origin and on the extension and aggressiveness of the disease. The imaging approach to these tumours is similar to that for other histological types and the Revised International Federation of Gynecology and Obstetrics (FIGO) Staging System also applies to NE tumours. Neuroendocrine tumours were recently divided into two groups: poorly differentiated neuroendocrine carcinomas (NECs) and well-differentiated neuroendocrine tumours (NETs). NECs include small cell carcinoma and large cell neuroendocrine carcinoma, while NETs account for typical and atypical carcinoids. Cervical small cell carcinoma and ovarian carcinoid are the most common gynaecological NE tumours. The former typically behaves aggressively; the latter usually behaves in a benign fashion and tends to be confined to the organ. CONCLUSION: While dealing with ovarian carcinoids, extra-ovarian extension, bilaterality and multinodularity raise the suspicion of metastatic disease. NE tumours of the endometrium and other gynaecological locations are very rare. TEACHING POINTS: • Primary or secondary neurondocrine (NE) tumours of the female genital tract are rare. • Cervical small cell carcinoma and ovarian carcinoids are the most common gynaecological NE tumours. • Cervical small cell carcinomas usually behave aggressively. • Ovarian carcinoids tend to behave in a benign fashion. • The imaging approach to gynaecological NE tumours and other histological types is similar.
Resumo:
PURPOSE: (i) To investigate whether pulsatility index (PI) and mean flow velocities (MFV) are altered in glaucoma patients. (ii) To evaluate the significance of PI in retrobulbar autoregulation capacity. METHODS: Patients with primary open-angle glaucoma (POAG; n = 49), normal tension glaucoma (NTG; n = 62) and healthy controls (n = 48) underwent colour Doppler imaging measurements of the retrobulbar vasculature. Kruskal-Wallis test was used to compare variables between the three diagnostic groups. Restricted cubic splines were used to determine nonlinearities between the resistive index (RI) and PI correlations. RESULTS: Mean flow velocities (MFV) were lower in both short posterior ciliary arteries (SCPA) and central retinal arteries (CRA) from the two glaucoma groups (p < 0.04 versus healthy controls). No differences were detected in RI or PI in any arteries of the three diagnostic groups (p > 0.08). In healthy individuals, correlations between RI and PI were linear in all arteries. In both POAG and NTG patients, CRA presented a nonlinear curve with a cutpoint at RI 0.77 (p < 0.001) and 0.61 (p = 0.03), respectively, above which the slope increased nearly five- and tenfold (POAG: 1.96 to 10.06; NTG: -0.46-4.06), respectively. A nonlinear correlation in the ophthalmic artery was only observed in NTG patients, with a cutpoint at RI 0.82 (p < 0.001), above which the slope increased from 3.47 to 14.03. CONCLUSIONS: Glaucoma patients do not present the linear relationships between RI and PI observed in healthy individuals. Their nonlinear relations may be indicative of an altered autoregulation and suggest a possible threshold RI could be determined above which autoregulatory disturbances become more relevant.
Resumo:
Childhood absence epilepsy (CAE) is a syndrome with well-defined electroclinical features but unknown pathological basis. An increased thalamic tonic GABA inhibition has recently been discovered on animal models (Cope et al., 2009), but its relevance for human CAE is unproven. METHODS: We studied an 11-year-old boy, presenting the typical clinical features of CAE, but spike-wave discharges (SWD) restricted to one hemisphere. RESULTS: High-resolution EEG failed to demonstrate independent contralateral hemisphere epileptic activity. Consistently, simultaneous EEG-fMRI revealed the typical thalamic BOLD activation, associated with caudate and default mode network deactivation, but restricted to the hemisphere with SWD. Cortical BOLD activations were localized on the ipsilateral pars transverse. Magnetic resonance spectroscopy, using MEGA-PRESS, showed that the GABA/creatine ratio was 2.6 times higher in the hemisphere with SWD than in the unaffected one, reflecting a higher GABA concentration. Similar comparisons for the patient's occipital cortex and thalamus of a healthy volunteer yielded asymmetries below 25%. SIGNIFICANCE: In a clinical case of CAE with EEG and fMRI-BOLD manifestations restricted to one hemisphere, we found an associated increase in thalamic GABA concentration consistent with a role for this abnormality in human CAE.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Dissertação para obtenção do Grau de Doutor em Química Sustentável
Resumo:
This work describes an electrochemical and quantum chemical investigation of the fipronil insecticide. Cyclic voltammetry (CV) and square wave voltammetry (SWV) experiments were performed over a graphite-polyurethane (GPU) composite electrode. The fipronil molecule presents an one?electron irreversible oxidation reaction. Profiting the SWV signal a square wave stripping voltammetry (SWSV) procedure to determine the fipronil molecule in a 0.10 mol L-1 Britton-Robinson buffer solution, pH 8.0 was developed with accumulation potential and time of 0.50 V and 120 s, respectively. The limits of detection and quantification were 0.80 and 2.67 ?g L-1, respectively. Recovery tests were performed in three natural waters samples with values ranging from 99.67 to 101.37%. Quantum chemical studies showed that the nitrogen atom of the pyrazole group is the most probable oxidation site of the fipronil molecule.