932 resultados para EFFLUX PUMP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Episodes of respiratory distress with chest retraction and wheezing, sometimes associated with facial edema, were noted after administering the proton pump inhibitors omeprazole and esomeprazole in an infant with gastroesophageal reflux. The disturbances relieved dramatically after withdrawing the proton pump inhibitor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Despite advances in surgical and interventional techniques, the optimal surgical treatment of severe aortic (re) coarctation and hypoplastic aortic arch is still controversial. Anatomic repair may require extensive dissection, cardiopulmonary bypass, and deep hypothermic circulatory arrest with their inherent risks. The aim of this study was to analyze the outcome of off-pump extraanatomic aortic bypass as a surgical alternative to local repair. METHODS: From February 2000 to December 2005, ten consecutive patients (median age 20 years; range, 11 to 38 years) with severe aortic (re) coarctation (n = 4) and (or) hypoplastic aortic arch (n = 7) underwent off-pump extraanatomic aortic bypass through median sternotomy. All but three patients had undergone previous surgery for coarctation and angioplasty or stenting. Three patients underwent concomitant replacement of the ascending aorta because of an aneurysm using cardiopulmonary bypass. RESULTS: Postoperative hospital course was uneventful in all patients. There was no perioperative mortality or significant morbidity. During a mean follow-up of 48 +/- 22 months no patient required additional procedures. All patients were free of symptoms; no patient showed signs of heart failure after follow-up. At last follow-up, no patient presented with claudication, nor any patient experienced orthostatic problems due to a steal phenomenon. During follow-up, hypertension resolved in all patients with residual mild hypertension in two patients. CONCLUSIONS: Off-pump extraanatomic aortic bypass is an attractive treatment option for complex aortic (re) coarctation and hypoplastic aortic arch. Perioperative risks are minimized, hypertension is influenced favorably, and midterm survival is event-free.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine anticoagulation strategies in OPCAB a questionnaire survey among 750 European cardio-thoracic surgeons was performed. Questions addressed volume of OPCAB procedures performed, intra- and perioperative heparinization and antiplatelet therapy, as well as perioperative management. A total of 325 (43.7%) questionnaires were returned and validated. Perioperative protocols for administration of antiplatelets differed among the respondent surgeons. Perioperative prophylaxis of thrombosis (low or high molecular weight heparin) is performed by 78%. Intraoperative heparin dosage range between 70 U/kg to 500 U/kg, 60% of respondents prefer a low-dose regimen (< or = 150 U/kg). Correspondingly, the lowest activated clotting time (ACT) during surgery is accepted to be 200 s by 24%, 250 s by 18% and 300 s by 26% of surgeons. Protamine is used by 91% of respondents, while 52% perform a 1:1 reversal. A cell-saver and antifibrinolytics are used by 70% and 40%, respectively. Interestingly, 56% of respondents think bleeding in OPCAB patients is not reduced when compared to on-pump CABG. In addition, 34% of respondents believe there is an increased risk of early graft occlusion following OPCAB. This survey demonstrates widely different intra- and perioperative anticoagulation strategies for OPCAB procedures among European surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study analyzes the effects on coagulation and fibrinolysis comparing off-pump coronary artery bypass (OPCAB) and on-pump CABG operations. METHODS: In a prospective, nonrandomized, comparative evaluation, patients scheduled for elective myocardial revascularization were studied. Due to possible confounding factors patients with postoperative retransfusion of mediastinal shed blood were excluded. Nine patients underwent OPCAB operation and 16 underwent on-pump CABG. Activated clotting time (ACT) was adjusted to 250 seconds in OPCAB (81 +/- 18 [mean +/- SD] IU/kg heparin) and to more than 480 seconds in on-pump CABG (400 IU/kg heparin, additional 10,000 IU in pump prime). Perioperatively blood samples were collected and hematologic and hemostatic variables including fibrinopeptide A (FPA), fibrin monomer (FM), thrombin-antithrombin complex (TAT), and D-dimer were analyzed. RESULTS: Both groups showed comparable demographic variables. Number of grafts per patient was slightly higher in the on-pump group (3.6 +/- 0.6 versus 3.0 +/- 1.1, p = 0.23). The FPA levels did not differ significantly between the groups. The FM, TAT, and D-dimer values were significantly higher in on-pump CABG (p < 0.0001, p < 0.01, and p < 0.0001, respectively), reflecting increased coagulant and fibrinolytic activity. This was also the case when values were corrected for hemodilution. CONCLUSIONS: Despite lower systemic anticoagulation activation of coagulation and fibrinolysis is reduced in OPCAB compared with on-pump CABG. Reduced thrombin generation and reduced fibrinolytic activity in OPCAB indicates better preservation of hemostasis. We suggest the term "preserved hemostasis" instead of "hypercoagulant activity" with respect to OPCAB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renewed interest in the measurement of cellular K(+) effluxes has been prompted by the observation that potassium plays an active and important role in numerous key cellular events, in particular cell necrosis and apoptosis. Although necrosis and apoptosis follow different pathways, both induce intracellular potassium effluxes. Here, we report the use of potassium-selective microelectrodes located in a microfluidic platform for cell culture to monitor and quantify such effluxes in real time. Using this platform, we observed and measured the early signs of cell lysis induced by a modification of the extracellular osmolarity. Furthermore, we were able to quantify the number of dying cells by evaluating the extracellular potassium concentration. A comparison between the potentiometric measurement with a fluorescent live-dead assay performed under similar conditions revealed the delay between potassium effluxes and cell necrosis. These results suggest that such platforms may be exploited for applications, such as cytotoxicological screening assays or tumor cell proliferation assays, by using extracellular K(+) as cell death marker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In haloarchaea, light-driven ion transporters have been modified by evolution to produce sensory receptors that relay light signals to transducer proteins controlling motility behavior. The proton pump bacteriorhodopsin and the phototaxis receptor sensory rhodopsin II (SRII) differ by 74% of their residues, with nearly all conserved residues within the photoreactive retinal-binding pocket in the membrane-embedded center of the proteins. Here, we show that three residues in bacteriorhodopsin replaced by the corresponding residues in SRII enable bacteriorhodopsin to efficiently relay the retinal photoisomerization signal to the SRII integral membrane transducer (HtrII) and induce robust phototaxis responses. A single replacement (Ala-215-Thr), bridging the retinal and the membrane-embedded surface, confers weak phototaxis signaling activity, and the additional two (surface substitutions Pro-200-Thr and Val-210-Tyr), expected to align bacteriorhodopsin and HtrII in similar juxtaposition as SRII and HtrII, greatly enhance the signaling. In SRII, the three residues form a chain of hydrogen bonds from the retinal's photoisomerized C(13)=C(14) double bond to residues in the membrane-embedded alpha-helices of HtrII. The results suggest a chemical mechanism for signaling that entails initial storage of energy of photoisomerization in SRII's hydrogen bond between Tyr-174, which is in contact with the retinal, and Thr-204, which borders residues on the SRII surface in contact with HtrII, followed by transfer of this chemical energy to drive structural transitions in the transducer helices. The results demonstrate that evolution accomplished an elegant but simple conversion: The essential differences between transport and signaling proteins in the rhodopsin family are far less than previously imagined.