889 resultados para Digital Forensics, Forensic Computing, Forensic Science
Resumo:
The purpose of this research is to assess the vulnerabilities of a high resolution fingerprint sensor when confronted with fake fingerprints. The study has not been focused on the decision outcome of the biometric device, but essentially on the scores obtained following the comparison between a query (genuine or fake) and a template using an AFIS system. To do this, fake fingerprints of 12 subjects have been produced with and without their cooperation. These fake fingerprints have been used alongside with real fingers. The study led to three major observations: First, genuine fingerprints produced scores higher than fake fingers (translating a closer proximity) and this tendency is observed considering each subject separately. Second, scores are however not sufficient as a single measure to differentiate these samples (fake from genuine) given the variation due to the donors themselves. That explains why fingerprint readers without vitality detection can be fooled. Third, production methods and subjects greatly influence the scores obtained for fake fingerprints.
Resumo:
This paper presents a statistical model for the quantification of the weight of fingerprint evidence. Contrarily to previous models (generative and score-based models), our model proposes to estimate the probability distributions of spatial relationships, directions and types of minutiae observed on fingerprints for any given fingermark. Our model is relying on an AFIS algorithm provided by 3M Cogent and on a dataset of more than 4,000,000 fingerprints to represent a sample from a relevant population of potential sources. The performance of our model was tested using several hundreds of minutiae configurations observed on a set of 565 fingermarks. In particular, the effects of various sub-populations of fingers (i.e., finger number, finger general pattern) on the expected evidential value of our test configurations were investigated. The performance of our model indicates that the spatial relationship between minutiae carries more evidential weight than their type or direction. Our results also indicate that the AFIS component of our model directly enables us to assign weight to fingerprint evidence without the need for the additional layer of complex statistical modeling involved by the estimation of the probability distributions of fingerprint features. In fact, it seems that the AFIS component is more sensitive to the sub-population effects than the other components of the model. Overall, the data generated during this research project contributes to support the idea that fingerprint evidence is a valuable forensic tool for the identification of individuals.
Resumo:
Tire traces can be observed on several crime scenes as vehicles are often used by criminals. The tread abrasion on the road, while braking or skidding, leads to the production of small rubber particles which can be collected for comparison purposes. This research focused on the statistical comparison of Py-GC/MS profiles of tire traces and tire treads. The optimisation of the analytical method was carried out using experimental designs. The aim was to determine the best pyrolysis parameters regarding the repeatability of the results. Thus, the pyrolysis factor effect could also be calculated. The pyrolysis temperature was found to be five time more important than time. Finally, a pyrolysis at 650 °C during 15 s was selected. Ten tires of different manufacturers and models were used for this study. Several samples were collected on each tire, and several replicates were carried out to study the variability within each tire (intravariability). More than eighty compounds were integrated for each analysis and the variability study showed that more than 75% presented a relative standard deviation (RSD) below 5% for the ten tires, thus supporting a low intravariability. The variability between the ten tires (intervariability) presented higher values and the ten most variant compounds had a RSD value above 13%, supporting their high potential of discrimination between the tires tested. Principal Component Analysis (PCA) was able to fully discriminate the ten tires with the help of the first three principal components. The ten tires were finally used to perform braking tests on a racetrack with a vehicle equipped with an anti-lock braking system. The resulting tire traces were adequately collected using sheets of white gelatine. As for tires, the intravariability for the traces was found to be lower than the intervariability. Clustering methods were carried out and the Ward's method based on the squared Euclidean distance was able to correctly group all of the tire traces replicates in the same cluster than the replicates of their corresponding tire. Blind tests on traces were performed and were correctly assigned to their tire source. These results support the hypothesis that the tested tires, of different manufacturers and models, can be discriminated by a statistical comparison of their chemical profiles. The traces were found to be not differentiable from their source but differentiable from all the other tires present in the subset. The results are promising and will be extended on a larger sample set.
Resumo:
This letter to the Editor comments on the article Practical relevance of pattern uniqueness in forensic science by P.T. Jayaprakash (Forensic Science International, in press).
Resumo:
A headspace solid-phase microextraction procedure (HS-SPME) was developed for the profiling of traces present in 3,4-methylenedioxymethylampethamine (MDMA). Traces were first extracted using HS-SPME and then analyzed by gas chromatography-mass spectroscopy (GC-MS). The HS-SPME conditions were optimized using varying conditions. Optimal results were obtained when 40 mg of crushed MDMA sample was heated at 80 °C for 15 min, followed by extraction at 80 °C for 15 min with a polydimethylsiloxane/divinylbenzene coated fibre. A total of 31 compounds were identified as traces related to MDMA synthesis, namely precursors, intermediates or by-products. In addition some fatty acids used as tabletting materials and caffeine used as adulterant, were also detected. The use of a restricted set of 10 target compounds was also proposed for developing a screening tool for clustering samples having close profile. 114 seizures were analyzed using an SPME auto-sampler (MultiPurpose Samples MPS2), purchased from Gerstel GMBH & Co. (Germany), and coupled to GC-MS. The data was handled using various pre-treatment methods, followed by the study of similarities between sample pairs based on the Pearson correlation. The results show that HS-SPME, coupled with the suitable statistical method is a powerful tool for distinguishing specimens coming from the same seizure and specimens coming from different seizures. This information can be used by law enforcement personnel to visualize the ecstasy distribution network as well as the clandestine tablet manufacturing.
Resumo:
Multi-phase postmortem CT angiography (MPMCTA) is recognized as a valuable tool to explore the vascular system, with higher sensitivity than conventional autopsy. However, a limitation is the impossibility to diagnose pulmonary embolism (PE) due to post-mortem blood clots situated in pulmonary arteries. The purpose of this study was to explore an eventual possibility to distinguish between real PE and artefacts mimicking PE. Our study included 416 medico-legal cases. All of them underwent MPMCTA, conventional autopsy and histological examination. We selected cases presenting arterial luminal filling defects in the pulmonary arteries. Their radiological interpretation was confronted to the one of autopsy and histological examination. We also investigated an eventual correlation between artefacts in pulmonary arteries and those in other parts of the vascular system. In 123 cases, filling defects of pulmonary arteries were described during MPMCTA. In 57 cases, this was interpreted as artefact and in 4 cases as suspected PE. In 62 cases only a differential diagnosis was made. Autopsy and histology could clearly identify the artefacts as such. Only one case of real PE was radiologically misinterpreted as artefact. In 6 of the 62 cases with no interpretation a PE was diagnosed. In 3 out of 4 suspected cases, PE was confirmed. We found out that filling defects in pulmonary arteries are nearly always associated to other vascular artefacts. Therefore, we suggest following some rules for radiological interpretation in order to allow a reliable diagnosis of pulmonary embolism after MPMCTA.
Resumo:
To evaluate the sensitivity of postmortem computed tomography (PMCT) in rib fracture detection validated against autopsy. Fifty-one forensic cases underwent a postmortem CT prior to forensic autopsy. Two image readers (radiologist and forensic pathologist) assessed high resolution CT data sets for rib fractures. Correct recognition rates (CRR), sensitivity and specificity values were calculated over all observations as well as individually for every rib and region. Additionally, for partial rib fractures the sensitivity of autopsy was calculated vice versa. 3876 entries in each study protocol (autopsy, PMCT radiologist and PMCT forensic pathologist) were investigated. A total of 690 fractures (autopsy), 491 (PMCT and radiologist) and 559 (PMCT and forensic pathologist) were detected. The CRR was 0.85. Sensitivity and specificity of PMCT for rib fracture detection were 0.63 (0.58 radiologist, 0.68 forensic pathologist) and 0.97 (both readers 0.97), respectively. Low CRR and sensitivity values were obtained for antero-lateral fractures. Partial rib fractures were better detected by PMCT. PMCT has a rather low sensitivity for rib fracture detection when validated against autopsy and indicates that clinical CT may also demonstrate a reasonable number of false negatives. Partial rib fractures often remain undetected at autopsy.
Resumo:
A fatality due to ingestion of a reversible inhibitor of monoamine-oxidase A (MAO-A) is reported. Moclobemide is generally considered as a safe drug far less toxic than tricyclic anti-depressants. However, severe intoxications may result from interactions with other drugs and food such as selective serotonin reuptake inhibitors (SSRIs), anti-Parkinsonians of the MAOI-type (e.g. selegiline) or tyramine from ripe cheese or other sources. In the present case, high levels of moclobemide were measured in peripheral blood exceeding toxic values reported so far in the scientific literature. The body fluid concentrations of moclobemide were of 498 mg/l in peripheral whole blood, 96.3 mg/l in urine while an amount of approximately 33 g could be recovered from gastric contents. The other xenobiotics were considered of little toxicological relevance. The victim (male, 48-year-old) had a past history of depression and committed one suicide attempt 2 years before death. Autopsy revealed no evidence of significant natural disease or injury. It was concluded that the manner of death was suicide and that the unique cause of death was massive ingestion of moclobemide.
Resumo:
Suicide by self-poisoning is rather common around the world. This paper presents an exceptional complex suicide in which nicotine was applied in the form of self-made patches soaked with an extraction from fine-cut tobacco. In addition, the 51-year-old suicide victim took a lethal dose of diphenhydramine. Toxicological analysis also revealed the presence of tetrazepam in subtherapeutic concentrations. The scene of death suggested an autoerotic accident at first, as the body was tied with tapes, cables and handcuffs. As a result of the entire investigations, the fatality had to be classified as a suicidal intoxication by nicotine and diphenhydramine.
Resumo:
Two likelihood ratio (LR) approaches are presented to evaluate the strength of evidence of MDMA tablet comparisons. The first one is based on a more 'traditional' comparison of MDMA tablets by using distance measures (e.g., Pearson correlation distance or a Euclidean distance). In this approach, LRs are calculated using the distribution of distances between tablets of the same-batch and that of different-batches. The second approach is based on methods used in some other fields of forensic comparison. Here LRs are calculated based on the distribution of values of MDMA tablet characteristics within a specific batch and from all batches. The data used in this paper must be seen as examples to illustrate both methods. In future research the methods can be applied to other and more complex data. In this paper, the methods and their results are discussed, considering their performance in evidence evaluation and several practical aspects. With respect to evidence in favor of the correct hypothesis, the second method proved to be better than the first one. It is shown that the LRs in same-batch comparisons are generally higher compared to the first method and the LRs in different-batch comparisons are generally lower. On the other hand, for operational purposes (where quick information is needed), the first method may be preferred, because it is less time consuming. With this method a model has to be estimated only once in a while, which means that only a few measurements have to be done, while with the second method more measurements are needed because each time a new model has to be estimated.
Resumo:
Since it is established that human chorionic gonadotropin (hCG) affects testosterone production and release in the human body, the use of this hormone as a performance enhancing drug has been prohibited by the World Anti-Doping Agency. Nowadays, the only validated biomarker of a hCG doping is its direct quantification in urine. However, this specific parameter is subjected to large inter-individual variability and its determination is directly dependent on the reliability of hCG immunoassays used. In order to counteract these weaknesses, new biomarkers need to be evidenced. To address this issue, a pilot clinical study was performed on 10 volunteers submitted to 3 subsequent hCG injections. Blood and urine samples were collected during two weeks in order to follow the physiological effects on related compounds such as the steroid profile or hormones involved in the hypothalamo-pituitary axis. The hCG pharmacokinetic observed in all subjects was, as expected, prone to important inter-individual variations. Using ROC plots, level of testosterone and testosterone on luteinizing hormone ratio in both blood and urine were found to be the most relevant biomarker of a hCG abuse, regardless of inter-individual variations. In conclusion, this study showed the crucial importance of reliable quantification methods to assess low differences in hormonal patterns. In regard to these results and to anti-doping requirements and constraints, blood together with urine matrix should be included in the anti-doping testing program. Together with a longitudinal follow-up approach it could constitute a new strategy to detect a hCG abuse, applicable to further forms of steroid or other forbidden drug manipulation.
Resumo:
The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.