995 resultados para Degradation monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

NanoPT 2014 International Conference, in Portugal, on February 12-14. Poster presentation based on topic Nanobio/Nanomedicine

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diversity of mosquito species was evaluated in different habitats before and after the Igarapava reservoir flooding in the Grande River, Southern Cerrado of Brazil. We aimed at verifying changes in these mosquito populations in consequence of the lake formation. Four habitats were selected as sampling stations: peridomiciliary habitat, pasture, "veredas" and gallery forest patch. Bimonthly collections were made with the Shannon trap and human bait, including diurnal, crepuscular and nocturnal period of mosquito activity. The Shannon Index results from the potential vectors were compared using Student t-test. Aedes scapularis, Anopheles darlingi and An. albitarsis senso latu seasonal abundance were described with moving average and compared using chi2 test. There were changes in the mosquito frequency in the habitats, except for the "veredas" that was 13 km away from the catchment area. The altering in mosquito species seasonal abundance suggests breeding places expansion. Diversity indexes can be used to monitor changes in mosquito vector population in environments where abrupt disturbance can alter disease transmission cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster presented in 28th GI/ITG International Conference on Architecture of Computing Systems (ARCS 2015). 25 to 28, Mar, 2015, Poster Session. Porto, Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 15th International Conference on Runtime Verification (RV'15). 22-25 September. Vienna, Austria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forty-six allogeneic hematopoietic stem cell transplantation (HSCT) patients were monitored for the presence of CMV antibodies, CMV-DNA and CMV antigens after transplantation. Immunoenzymatic serological tests were used to detect IgM and the increase in CMV IgG antibodies (increase IgG), a nested polymerase chain reaction (N-PCR) was used to detect CMV-DNA, and an antigenemia assay (AGM) was used to detect CMV antigens. The presence of CMV-IgM and/or CMV-increase IgG antibodies was detected in 12/46 (26.1%) patients, with a median time between HSCT and the detection of positive serology of 81.5 days. A positive AGM was detected in 24/46 (52.2%) patients, with a median time between HSCT and antigen detection of 62 days. Two or more consecutive positive N-PCR results were detected in 32/46 (69.5%) patients, with a median time between HSCT and the first positive PCR of 50.5 days. These results confirmed that AGM and mainly PCR are superior to serology for the early diagnosis of CMV infection. Six patients had CMV-IgM and/or CMV-increase IgG with a negative AGM (five cases) or N-PCR assay (one case). In five of these cases the serological markers were detected during the first 100 days after HSCT, the period of highest risk. These findings support the idea that serology may be useful for monitoring CMV infections in HSCT patients, especially when PCR is unavailable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Electromyography (EMG) is an important tool for gait analyzes and disorders diagnoses. Traditional methods involve equipment that can disturb the analyses, being gradually substituted by different approaches, like wearable and wireless systems. The cable replacement for autonomous systems demands for technologies capable of meeting the power constraints. This work presents the development of an EMG and kinematic data capture wireless module, designed taking into account power consumption issues. This module captures and converts the analog myoeletric signal to digital, synchronously with the capture of kinetic information. Both data are time multiplexed and sent to a PC via Bluetooth link. The work carried out comprised the development of the hardware, the firmware and a graphical interface running in an external PC. The hardware was developed using the PIC18F14K22, a low power family of microcontrollers. The link was established via Bluetooth, a protocol designed for low power communication. An application was also developed to recover and trace the signal to a Graphic User Interface (GUI), coordinating the message exchange with the firmware. Results were obtained which allowed validating the conceived system in static and with the subject performing short movements. Although it was not possible to perform the tests within more dynamic movements, it is shown that it is possible to capture, transmit and display the captured data as expected. Some suggestions to improve the system performance also were made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work was to develop a reliable alternative method for the determination of the dithiocarbamate pesticide mancozeb (MCZ) in formulations. Furthermore, a method for the analysis of MCZ's major degradation product, ethylenethiourea (ETU), was also proposed. Cyclic voltammetry was used to characterize the electrochemical behavior of MCZ and ETU, and square-wave adsorptive stripping voltammetry (SWAdSV) was employed for MCZ quantification in commercial formulations. It was found that both MCZ and ETU are irreversibly reduced (− 0.6 V and − 0.5 V vs Ag/AgCl, respectively) at the surface of a glassy carbon electrode in a mainly diffusion-controlled process, presenting maximum peak current intensities at pH 7.0 (in phosphate buffered saline electrolyte). Several parameters of the SWAdSV technique were optimized and linear relationships between concentration and peak current intensity were established between 10–90 μmol L− 1 and 10–110 μmol L− 1 for MCZ and ETU, respectively. The limits of detection were 7.0 μmol L− 1 for MCZ and 7.8 μmol L− 1 for ETU. The optimized method for MCZ was successfully applied to the quantification of this pesticide in two commercial formulations. The developed procedures provided accurate and precise results and could be interesting alternatives to the established methods for quality control of the studied products, as well as for analysis of MCZ and ETU in environmental samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presented at INForum - Simpósio de Informática (INFORUM 2015). 7 to 8, Sep, 2015. Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain the Master degree in Electrical Engineering and Computer Science

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development and application of a polyaniline/carbon nanotube (CNT) cyclodextrin matrix (PANI-β-CD/MWCNT)-based electrochemical sensor for the quantitative determination of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA) and its main transformation product 4-chloro-2-methylphenol in natural waters are described. A simple cyclic voltammetry-based electrochemical methodology, in phosphate buffer solution at pH 6.0, was used to develop a method to determine both MCPA and 4-chloro-2-methylphenol, without any previous extraction or derivatization steps. A linear concentration range (10 to 50 μmol L−1) and detection limits of 1.1 and 1.9 μmol L−1, respectively, were achieved using optimized cyclic voltammetric parameters. The proposed method was successfully applied to the determination of MCPA and 4-chloro-2-methylphenol in natural water samples with satisfactory recoveries (94 to 107 %) and in good agreement with the results obtained by an established high-performance liquid chromatography technique, no significant differences being found between the methods. Interferences from ionic species and other herbicides used for broad-leaf weed control were shown to be small. The newly developed methodology was also successfully applied to MCPA photodegradation environmental studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present ezGo, an electric powered wheelchair with a speech based interface and biosignal monitoring instrumentation. The user can use the voice, a natural communication method, for controlling the chair movement and obtain information about his health. Additionally a set of semi-autonomous modes with macro recording enable the execution of navigation tasks with little effort and improved precision. The main purpose of the system is to provide severely disabled persons with an assistive device that can improve their confidence and daily independence. The obtained results on usability tests showed that users consider ezGo a valuable help on their daily tasks and a very desirable addition to standard wheelchairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a primary response to Toxoplasma gondii following a hematopoietic stem cell transplantation in a patient with multiple myeloma. The primary response to T. gondii was supported by IgM, IgG and IgA seroconversion. The patient was promptly treated and there were no complications related to toxoplasmosis in the subsequent months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malaria is an unusual complication after hematopoietic stem cell transplantation in non-endemic countries. However, transplant candidates, recipients and donors living in endemic regions frequently report previous episodes of malaria. This fact could represent an important risk for immunosuppressed recipients that could develop severe malaria cases. We report a case of hematopoietic stem cell transplant (HSCT) in which the donor had a history of previous malaria, and close monitoring was performed before and after procedure by parasitological and molecular tests. The donor presented Plasmodium vivax in thick blood smears one month after transplant and was treated according to Brazilian Health Ministry guidelines. The polymerase chain reaction (PCR) was able to detect malaria infection in the donor one week earlier than thick blood film. Even without positive results, the recipient was pre-emptively treated with chloroquine in order to prevent the disease. We highlight the importance of monitoring recipients and donors in transplant procedures with the aim of reducing the risk of malaria transmission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.