845 resultados para Cramps abdominal
Resumo:
BACKGROUND: Integrity of the abdominal aortic aneurysm (AAA) neck is crucial for the long-term success of endovascular AAA repair (EVAR). However, suitable tools for reliable assessment of changes in small aortic volumes are lacking. The purpose of this study was to assess the intraobserver and interobserver variability of software-enhanced 64-row computed tomographic angiography (CTA) AAA neck volume measurements in patients after EVAR. METHODS: A total of 25 consecutive patients successfully treated by EVAR underwent 64-row follow-up CTA in 1.5-mm collimation. Manual CTA measurements were performed twice by three blinded and independent readers in random order with at least a 4-week interval between readings. Maximum and minimum transverse aortic neck diameters were measured twice on two different levels within the proximal neck. Volumetry of the proximal aortic neck was performed by using dedicated software. Variability was calculated as 1.96 SD of the mean arithmetic difference according to Bland and Altman. Two-sided and paired t tests were used to compare measurements. P values <.05 were considered to indicate statistical significance. RESULTS: Intraobserver agreement was excellent for dedicated aneurysmal neck volumetry, with mean differences of less than 1 mL (P > .05), whereas it was poor for transverse aortic neck diameter measurements (P < .05). However, interobserver variability was statistically significant for both neck volumetry (P < .005) and neck diameter measurements (P < .015). CONCLUSIONS: The reliability of dedicated AAA neck volumetry by using 64-row CTA is excellent for serial measurements by individual readers, but not between different readers. Therefore, studies should be performed with aortic neck volumetry by a single experienced reader.
Resumo:
INTRODUCTION: The indications for endovascular aortic aneurysm repair (EVAR) are mainly established in hostile abdomen, in patients with significant comorbidities which affect the general operability of the patient and, given the necessary infrastructure, also in ruptured aneurysm. Along to those, we present another possible indication in the presence of a kidney allograft in patients with aortic aneurysm. METHODS: Based on a case report of aorto-biiliac stent-graft repair of an infrarenal aortic aneurysm in a patient with renal allograft, a systematic review of the literature was performed of all similar cases concerning surgical therapy in this constellation. RESULTS: EVAR was performed using an aorto-biiliac system (Zenith) Trifab, COOK) in a 61-year-old male patient 11 years after heterotopic renal allotransplantation in the right iliac fossa. Preoperative renal function was normal. Because the donor renal artery was anastomosed to the recipient's external iliac artery the stent-graft was implanted from the left common femoral artery to minimize temporary allograft ischemia. The intra- and postoperative course was uneventful with a follow-up of presently 12 months. A primary type-II endoleak (retroleak from a lumbar artery) is being treated conservatively so far with embolization being a future option. At present there are 15 cases of EVAR in renal allograft patients that have been reported, all of them being successful. DISCUSSION: All data existing in the literature reported to date as well as our own experience justify the first choice of EVAR in morphologically suitable cases. One major advantage of EVAR in this constellation is the avoidance of aortic cross clamping which poses the graft at risk of ischemia. Long-term results will be most important for definite assessment of EVAR. However, contrast media application during the operation and for CT surveillance should be considered as a major disadvantage.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. MATERIALS AND METHODS: One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. RESULTS: Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). CONCLUSION: Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.
Resumo:
OBJECTIVE: Anemia is a common comorbid condition in various inflammatory states and an established predictor of mortality in patients with chronic heart failure, ischemic heart disease, and end-stage renal disease. The present study of patients with abdominal aortic aneurysm (AAA) undergoing endovascular repair (EVAR) assessed the relationships between baseline hemoglobin concentration and AAA size, as well as anemia and long-term survival. METHODS: Between March 1994 and November 2006, 711 patients (65 women, mean age 75.8 +/- 7.8 years) underwent elective EVAR. Anemia was defined as a hemoglobin level <13 g/dL in men and <12 g/dL in women. Post-EVAR mean follow-up was 48.3 +/- 32.0 months. Association of hemoglobin level with AAA size was assessed with multiple linear regression. Mortality was determined with use of the internet-based Social Security Death Index and the electronic hospital record. Kaplan-Meier survival curves of anemic and nonanemic patient groups were compared by the log-rank method. Multivariable logistic regression models were used to determine the influence of anemia on vital status after EVAR. RESULTS: A total of 218/711 (30.7%) of AAA patients undergoing EVAR had anemia at baseline. After adjustment for various risk factors, hemoglobin level was inversely related to maximum AAA diameter (beta: - .144, 95%-CI: -1.482 - .322, P = .002). Post-EVAR survival was 65.5% at 5 years and 44.4% at 10 years. In long-term follow-up, survival was significantly lower in patients with anemia as compared to patients without anemia (P < .0001 by log-rank). Baseline hemoglobin levels were independently related to long-term mortality in multivariable Cox regression analysis adjusted for various risk factors (adjusted HR: 0.866, 95% CI: .783 to .958, P = .005). Within this model, statin use (adjusted HR: .517, 95% CI: .308 to .868, P = .013) was independently related to long-term survival, whereas baseline AAA diameter (adjusted HR: 1.022, 95% CI: 1.009 to 1.036, P = .001) was an independently associated with increased mortality. CONCLUSIONS: Baseline hemoglobin concentration is independently associated with AAA size and reduced long-term survival following EVAR. Thus, the presence or absence of anemia offers a potential refinement of existing risk stratification instruments.
Resumo:
The patient with abdominal aortic aneurysm (AAA) commonly is a nondiabetic, white man with a history of smoking. Moreover, AAA represents a leading cause of death in elderly men in Western countries. The purpose of this manuscript is to review current evidence as to the pathobiology of AAA as well as potential future drug targets to prevent progression of AAA.
Resumo:
PURPOSE: To elucidate the association of impaired pulmonary status (IPS) and diabetes mellitus (DM) with clinical outcome and the incidences of aortic neck dilatation and type I endoleak after elective endovascular infrarenal aortic aneurysm repair (EVAR). METHODS: In 164 European institutions participating in the EUROSTAR registry, 6383 patients (5985 men; mean age 72.4+/-7.6 years) underwent EVAR. Patients were divided into patients without versus with IPS or with/without DM. Clinical assessment and contrast-enhanced computed tomography (CT) were performed at 1, 3, 6, 12, 18, and 24 months and annually thereafter. Cumulative endpoint analysis comprised death, aortic rupture, type I endoleak, endovascular reintervention, and surgical conversion. RESULTS: Prevalence of IPS was 2733/6383 (43%) and prevalence of DM was 810/6383 (13%). Mean follow-up was 21.1+/-18.4 months. Thirty-day mortality, AAA rupture, and conversion rates did not differ between patients with versus without IPS and between patients with versus without DM. All-cause and AAA-related mortality, respectively, were significantly higher in patients with IPS compared to patients with normal pulmonary status (31.0% versus 19.0%, p<0.0001 and 6.8% versus 3.3%, p = 0.0057) throughout follow-up. In multivariate analysis adjusted for smoking, age, gender, comorbidities, fitness for open repair, co-existing common iliac aneurysm, neck and aneurysm size, arterial angulations, aneurysm classification, endograft oversizing >or=15%, and type of stent-graft, the presence of IPS was not associated with significantly higher rates of aortic neck dilatation (30.6% versus 38.0%, p>0.05) and did not influence cumulative rates of type I endoleak, endovascular reintervention, or conversion to open surgery (p>0.05). Similarly, the presence of DM did not influence the above-mentioned study endpoints. CONCLUSION: In contrast to observations regarding the natural course of AAAs, impaired pulmonary status does not negatively influence aortic neck dilatation, while the presence of diabetes does not protect from these dismal events after EVAR.
Resumo:
Because of superior soft-tissue contrast compared to other imaging techniques, non-invasive abdominal magnetic resonance imaging (MRI) is ideal for monitoring organ regeneration, tissue repair, cancer stage, and treatment effects in a wide variety of experimental animal models. Currently, sophisticated MR protocols, including technically demanding procedures for motion artefact compensation, achieve an MRI resolution limit of < 100 microm under ideal conditions. However, such a high spatial resolution is not required for most experimental rodent studies. This article describes both a detailed imaging protocol for MR data acquisition in a ubiquitously and commercially available 1.5 T MR unit and 3-dimensional volumetry of organs, tissue components, or tumors. Future developments in MR technology will allow in vivo investigation of physiological and pathological processes at the cellular and even the molecular levels. Experimental MRI is crucial for non-invasive monitoring of a broad range of biological processes and will further our general understanding of physiology and disease.
Resumo:
RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.
Resumo:
To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P < 0.001), homogeneity of the luminal content (P < 0.001), delineation of the bowel-wall to the lumen (P < 0.001) and to the mesentery (P < 0.001) and artifacts (P < 0.001), leading to a significant better overall image quality (P < 0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P < 0.001) and wall to lumen delineation (P < 0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population.
Resumo:
BACKGROUND: Purpose of this study was to compare the correlation of statin use with long-term mortality in patients with abdominal (AAA) and thoracic aortic aneurysm (TAA). PATIENTS AND METHODS: We compared long-term survival of 731 AAA and 59 TAA patients undergoing elective endovascular repair (EVAR). Kaplan-Meier survival curves were compared by the log-rank method. Propensity score-adjusted multivariable logistic regression models were used to determine independent associations of statin use on vital status after EVAR. RESULTS: Statin use was associated with decreased long-term mortality in AAA patients in bivariate and multivariable regression analysis, in which the effect of propensity to receive a statin was considered (adjusted HR: .613, 95%-CI: .379- .993, p = .047) whereas mortality of TAA patients was not associated with use of statins (adjusted HR: 1.795, 95%-CI: .147 -21.942, p = .647). CONCLUSIONS: Use of statins is an independent predictor of decreased mortality after elective EVAR in AAA, but not in TAA patients. These findings indirectly support the concept of a distinct pathogenesis of AAA and TAA.
Resumo:
Continuing aortic neck dilatation, most probably an expression of ongoing aneurysmal wall degeneration of the infrarenal aortic segment, has been shown to seriously impair clinical results after endovascular abdominal aortic aneurysm repair. However, conflicting data on the extent and clinical relevance on this observation have recently been published. This article reviews the recent literature, summarizing our current understanding of the role of aortic neck dilatation after open surgical and endovascular abdominal aortic aneurysm repair. In addition, differences in methodology of studies on aortic neck dilatation are highlighted.
Resumo:
PURPOSE: To compare clinical outcomes of endovascular and open aortic repair of abdominal aortic aneurysms (AAAs) in young patients at low risk. It was hypothesized that endovascular aneurysm repair (EVAR) compares favorably with open aneurysm repair (OAR) in these patients. MATERIALS AND METHODS: Twenty-five patients aged 65 years or younger with a low perioperative surgical risk profile underwent EVAR at a single institution between April 1994 and May 2007 (23 men; mean age, 62 years+/-2.8). A sex- and risk-matched control group of 25 consecutive patients aged 65 years or younger who underwent OAR was used as a control group (23 men; mean age, 59 years+/-3.9). Patient outcomes and complications were classified according to Society of Vascular Surgery/International Society for Cardiovascular Surgery reporting standards. RESULTS: Mean follow-up times were 7.1 years+/-3.2 after EVAR and 5.9 years+/-1.8 after OAR (P=.1020). Total complication rates were 20% after EVAR and 52% after OAR (P=.0378), and all complications were mild or moderate. Mean intensive care unit times were 0.2 days+/-0.4 after EVAR and 1.1 days+/-0.4 after OAR (P<.0001) and mean lengths of hospital stay were 2.3 days+/-1.0 after EVAR and 5.0 days+/-2.1 after OAR (P<.0001). Cumulative rates of long-term patient survival did not differ between EVAR and OAR (P=.144). No AAA-related deaths or aortoiliac ruptures occurred during follow-up for EVAR and OAR. In addition, no surgical conversions were necessary in EVAR recipients. Cumulative rates of freedom from secondary procedures were not significantly different between the EVAR and OAR groups (P=.418). Within a multivariable Cox proportional-hazards analysis adjusted for patient age, maximum AAA diameter, and cardiac risk score, all-cause mortality rates (odds ratio [OR], 0.125; 95% CI, 0.010-1.493; P=.100) and need for secondary procedures (OR, 5.014; 95% CI, 0.325-77.410; P=.537) were not different between EVAR and OAR. CONCLUSIONS: Results from this observational study indicate that EVAR offers a favorable alternative to OAR in young patients at low risk.