917 resultados para Coronary-artery-disease, Productivity-costs


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coronary artery aneurysms, commonly atherosclerotic, are usually asymptomatic and can be diagnosed incidentally during investigation for ischemic heart disease or on autopsy. An asymptomatic giant right coronary artery aneurysm presenting as a paracardiac mass discovered on autopsy is reported here. Even though there was great concern due to its large size, complex atherosclerotic lesions, and potential obstruction of blood flow, it had no direct link to the cause of death. We also review the literature on giant right coronary artery aneurysms exceeding 5 cm in the last 10 years. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether the intima-media thickness of the common carotid artery of patients with coronary artery disease is greater than that of individuals without that disease. METHODS: Case-control prospective study of prevalence assessing the thickness of the intima and media layers of 29 patients with coronary artery disease and 29 individuals without that disease by using ultrasonography of the carotid arteries. Diabetic patients and those with peripheral artery and cerebral vasculopathies were excluded from the study. RESULTS: The mean age was 51±7.5 years. Fifty-five per cent of the patients were males. Acute myocardial infarction was present in 62%; cardiac catheterization in 72%; saphenous bypass in 5%; and coronary angioplasty in 24%. The intima-media thickness of the common carotid artery in case patients and in control patients was, respectively, 0.81±0.25 mm and 0.62±0.18 mm (P=0.001). CONCLUSION: Intima-media thickness of the common carotid artery was significantly greater in patients with coronary artery disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether a difference exists in coronary heart disease clinical manifestations and the prevalence of risk factors between Japanese immigrants and their descendents in the city of São Paulo. METHODS: Retrospective analysis of coronary artery disease clinical manifestations and the prevalence of risk factors, comparing 128 Japanese immigrants (Japanese group) with 304 Japanese descendents (Nisei group). RESULTS: The initial manifestation of the disease was earlier in the Nisei group (mean = 53 years), a difference of 12 years when compared with that in the Japanese group (mean = 65 years) (P<0.001). Myocardial infarction was the first manifestation in both groups (P = 0.83). The following parameters were independently associated with early coronary events: smoking (OR = 2.25; 95% CI = 1.35-3.77; P<0.002); Nisei group (OR = 10.22; 95% CI = 5.64-18.5; P<0.001); and female sex (OR = 5.04; 95% CI = 2.66-9.52; P<0.001). CONCLUSION: The clinical presentation of coronary heart disease in the Japanese and their descendents in the city of São Paulo was similar, but coronary heart disease onset occurred approximately 12 years earlier in the Nisei group than in the Japanese group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:Several studies have shown that Tai Chi Chuan can improve cardiac function in patients with heart disease.Objective:To conduct a systematic review of the literature to assess the effects of Tai Chi Chuan on cardiac rehabilitation for patients with coronary artery disease.Methods:We performed a search for studies published in English, Portuguese and Spanish in the following databases: MEDLINE, EMBASE, LILACS and Cochrane Register of Controlled Trials. Data were extracted in a standardized manner by three independent investigators, who were responsible for assessing the methodological quality of the manuscripts.Results:The initial search found 201 studies that, after review of titles and abstracts, resulted in a selection of 12 manuscripts. They were fully analyzed and of these, nine were excluded. As a final result, three randomized controlled trials remained. The studies analyzed in this systematic review included patients with a confirmed diagnosis of coronary artery disease, all were clinically stable and able to exercise. The three experiments had a control group that practiced structured exercise training or received counseling for exercise. Follow-up ranged from 2 to 12 months.Conclusion:Preliminary evidence suggests that Tai Chi Chuan can be an unconventional form of cardiac rehabilitation, being an adjunctive therapy in the treatment of patients with stable coronary artery disease. However, the methodological quality of the included articles and the small sample sizes clearly indicate that new randomized controlled trials are needed in this regard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular diseases are the main causes of mortality and morbidity in Brazil. Their primary and secondary preventions are a priority for the health system and require multiple approaches for increased effectiveness. Biomarkers are tools used to identify with greater accuracy high-risk individuals, establish a faster diagnosis, guide treatment, and determine prognosis. This review aims to highlight the importance of biomarkers in clinical cardiology practice and raise relevant points regarding their application and perspectives for the next few years. This document was divided into two parts. This second part addresses the application of biomarkers in coronary heart disease, valvular diseases, cardio-oncology, pulmonary embolism, and cardiorenal syndrome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a case of a 71-year-old man with a long coronary artery disease history and two sets of coronary artery bypass grafts. He developed large aortocoronary saphenous vein graft aneurysms in the two grafts from the first set of aortocoronary saphenous venous 20 years later. During the previous 3 years, the aneurysms grew in diameter from 22 to 50 mm. Because of severe renal insufficiency, and in order to avoid jeopardizing the late normal coronary artery bypass grafts by further thoracic surgery, we excluded successfully these altered grafts percutaneously by using 13 coils during the same procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Data from prospective cohort studies regarding the association between subclinical hyperthyroidism and cardiovascular outcomes are conflicting.We aimed to assess the risks of total and coronary heart disease (CHD) mortality, CHD events, and atrial fibrillation (AF) associated with endogenous subclinical hyperthyroidism among all available large prospective cohorts. METHODS: Individual data on 52 674 participants were pooled from 10 cohorts. Coronary heart disease events were analyzed in 22 437 participants from 6 cohorts with available data, and incident AF was analyzed in 8711 participants from 5 cohorts. Euthyroidism was defined as thyrotropin level between 0.45 and 4.49 mIU/L and endogenous subclinical hyperthyroidism as thyrotropin level lower than 0.45 mIU/L with normal free thyroxine levels, after excluding those receiving thyroid-altering medications. RESULTS: Of 52 674 participants, 2188 (4.2%) had subclinical hyperthyroidism. During follow-up, 8527 participants died (including 1896 from CHD), 3653 of 22 437 had CHD events, and 785 of 8711 developed AF. In age- and sex-adjusted analyses, subclinical hyperthyroidism was associated with increased total mortality (hazard ratio[HR], 1.24, 95% CI, 1.06-1.46), CHD mortality (HR,1.29; 95% CI, 1.02-1.62), CHD events (HR, 1.21; 95%CI, 0.99-1.46), and AF (HR, 1.68; 95% CI, 1.16-2.43).Risks did not differ significantly by age, sex, or preexisting cardiovascular disease and were similar after further adjustment for cardiovascular risk factors, with attributable risk of 14.5% for total mortality to 41.5% forAF in those with subclinical hyperthyroidism. Risks for CHD mortality and AF (but not other outcomes) were higher for thyrotropin level lower than 0.10 mIU/L compared with thyrotropin level between 0.10 and 0.44 mIU/L(for both, P value for trend, .03). CONCLUSION: Endogenous subclinical hyperthyroidism is associated with increased risks of total, CHD mortality, and incident AF, with highest risks of CHD mortality and AF when thyrotropin level is lower than 0.10 mIU/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is a frequent arrhythmia after conventional coronary artery bypass grafting. With the advent of minimally invasive technique for left internal mammary artery-left anterior descending coronary artery (LIMA-LAD) grafting, we analyzed the incidence and the risk factors of postoperative AF in this patient population. This prospective study involves all patients undergoing isolated LIMA-LAD grafting with minimally invasive technique between January 1994 and June 2000. Twenty-four possible risk factors for postoperative AF were entered into univariate and multivariate logistic regression analyses. Postoperative AF occurred in 21 of the 90 patients (23.3%) analyzed. Double- or triple-vessel disease was present in 12/90 patients (13.3%). On univariate analysis, right coronary artery disease (p <0.01), age (p = 0.01), and diabetes (p = 0.04) were found to be risk factors for AF. On multivariate analysis, right coronary artery disease was identified as the sole significant risk factor (p = 0.02). In this patient population, the incidence of AF after minimally invasive coronary artery bypass is in the range of that reported for conventional coronary artery bypass grafting. Right coronary artery disease was found to be an independent predictor, and this may be related to the fact that in this patient population the diseased right coronary artery was not revascularized at the time of the surgical procedure. For the same reason, this risk factor may find a broader application to noncardiac thoracic surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 49-year-old woman, without known cardiovascular risk factors. Hoarseness of voice caused by a paralysis of left vocal cord. She was admitted to hospital because of acute coronary syndrome, associated to resuscitated cardiac arrest (asystolia documented) without later neurology sequels. Physical examination was anodyne. Echocardiographic study demonstrated a compatible image with a large left sinus of Valsalva aneurysm (SVA) (Panel A) and mild aortic regurgitation. Cardiac catheterization confirmed the presence of left SVA (Panel B) that produced extrinsic compression of the left main coronary artery (Panels C and D). Repair surgery was made by means of closing the aneurysmal orifice with a patch of dacron. Intra-operatory echocardiographic control study found severe aortic regurgitation, so valvular replacement with 19 mm mechanical prosthesis and extension of the valve annulus with patch of dacron was performed, associated with bypass with safena vein graft to left coronary artery. SVA is a very infrequent cardiac anomaly, generally with silent clinical course until it ruptures. Myocardial ischaemia caused by coronary artery compression is unusual. We described the case of a patient diagnosed of left SVA, whose initial clinical manifestation was the appearance of resuscitated sudden cardiac death in the context of an acute coronary syndrome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: We sought to evaluate the utility of contrast-enhanced coronary magnetic resonance imaging (CE-MRI) for selective visualization and non-invasive differentiation of atherosclerotic coronary plaque in humans. METHODS AND RESULTS: Nine patients with coronary artery disease (CAD) as confirmed by X-ray angiography and multidetector computed tomography (MDCT) were studied by T1-weighted black blood inversion recovery coronary MRI before (N-IR) and after administration of Gd-DTPA (CE-IR). Plaques were categorized as calcified, non-calcified, and mixed based on their Hounsfield number derived from MDCT. With MDCT, a total of 29 plaques were identified, including calcified (n=6), non-calcified (n=6), and mixed calcified/non-calcified (n=17). On N-IR MRI, 26 plaques (90%) were dark, whereas three plaques (two non-calcified and one mixed) appeared bright. On CE-MRI, 13/29 (45%) plaques, 11 of which were mixed, one non-calcified, and one calcified showed contrast uptake. All others remained dark. CONCLUSION: In this preliminary study, we demonstrate the potential utility of CE-IR MRI for selective plaque visualization and differentiation of plaque types. The observed contrast uptake may be associated with endothelial dysfunction, neovascularization, inflammation, and/or fibrosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Coronary artery calcification (CAC) detected by computed tomography is a noninvasive measure of coronary atherosclerosis, which underlies most cases of myocardial infarction (MI). We sought to identify common genetic variants associated with CAC and further investigate their associations with MI. METHODS AND RESULTS: Computed tomography was used to assess quantity of CAC. A meta-analysis of genome-wide association studies for CAC was performed in 9961 men and women from 5 independent community-based cohorts, with replication in 3 additional independent cohorts (n=6032). We examined the top single-nucleotide polymorphisms (SNPs) associated with CAC quantity for association with MI in multiple large genome-wide association studies of MI. Genome-wide significant associations with CAC for SNPs on chromosome 9p21 near CDKN2A and CDKN2B (top SNP: rs1333049; P=7.58×10(-19)) and 6p24 (top SNP: rs9349379, within the PHACTR1 gene; P=2.65×10(-11)) replicated for CAC and for MI. Additionally, there is evidence for concordance of SNP associations with both CAC and MI at a number of other loci, including 3q22 (MRAS gene), 13q34 (COL4A1/COL4A2 genes), and 1p13 (SORT1 gene). CONCLUSIONS: SNPs in the 9p21 and PHACTR1 gene loci were strongly associated with CAC and MI, and there are suggestive associations with both CAC and MI of SNPs in additional loci. Multiple genetic loci are associated with development of both underlying coronary atherosclerosis and clinical events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'imagerie par résonance magnétique (IRM) peut fournir aux cardiologues des informations diagnostiques importantes sur l'état de la maladie de l'artère coronarienne dans les patients. Le défi majeur pour l'IRM cardiaque est de gérer toutes les sources de mouvement qui peuvent affecter la qualité des images en réduisant l'information diagnostique. Cette thèse a donc comme but de développer des nouvelles techniques d'acquisitions des images IRM, en changeant les techniques de compensation du mouvement, pour en augmenter l'efficacité, la flexibilité, la robustesse et pour obtenir plus d'information sur le tissu et plus d'information temporelle. Les techniques proposées favorisent donc l'avancement de l'imagerie des coronaires dans une direction plus maniable et multi-usage qui peut facilement être transférée dans l'environnement clinique. La première partie de la thèse s'est concentrée sur l'étude du mouvement des artères coronariennes sur des patients en utilisant la techniques d'imagerie standard (rayons x), pour mesurer la précision avec laquelle les artères coronariennes retournent dans la même position battement après battement (repositionnement des coronaires). Nous avons découvert qu'il y a des intervalles dans le cycle cardiaque, tôt dans la systole et à moitié de la diastole, où le repositionnement des coronaires est au minimum. En réponse nous avons développé une nouvelle séquence d'acquisition (T2-post) capable d'acquérir les données aussi tôt dans la systole. Cette séquence a été testée sur des volontaires sains et on a pu constater que la qualité de visualisation des artère coronariennes est égale à celle obtenue avec les techniques standard. De plus, le rapport signal sur bruit fourni par la séquence d'acquisition proposée est supérieur à celui obtenu avec les techniques d'imagerie standard. La deuxième partie de la thèse a exploré un paradigme d'acquisition des images cardiaques complètement nouveau pour l'imagerie du coeur entier. La technique proposée dans ce travail acquiert les données sans arrêt (free-running) au lieu d'être synchronisée avec le mouvement cardiaque. De cette façon, l'efficacité de la séquence d'acquisition est augmentée de manière significative et les images produites représentent le coeur entier dans toutes les phases cardiaques (quatre dimensions, 4D). Par ailleurs, l'auto-navigation de la respiration permet d'effectuer cette acquisition en respiration libre. Cette technologie rend possible de visualiser et évaluer l'anatomie du coeur et de ses vaisseaux ainsi que la fonction cardiaque en quatre dimensions et avec une très haute résolution spatiale et temporelle, sans la nécessité d'injecter un moyen de contraste. Le pas essentiel qui a permis le développement de cette technique est l'utilisation d'une trajectoire d'acquisition radiale 3D basée sur l'angle d'or. Avec cette trajectoire, il est possible d'acquérir continûment les données d'espace k, puis de réordonner les données et choisir les paramètres temporel des images 4D a posteriori. L'acquisition 4D a été aussi couplée avec un algorithme de reconstructions itératif (compressed sensing) qui permet d'augmenter la résolution temporelle tout en augmentant la qualité des images. Grâce aux images 4D, il est possible maintenant de visualiser les artères coronariennes entières dans chaque phase du cycle cardiaque et, avec les mêmes données, de visualiser et mesurer la fonction cardiaque. La qualité des artères coronariennes dans les images 4D est la même que dans les images obtenues avec une acquisition 3D standard, acquise en diastole Par ailleurs, les valeurs de fonction cardiaque mesurées au moyen des images 4D concorde avec les valeurs obtenues avec les images 2D standard. Finalement, dans la dernière partie de la thèse une technique d'acquisition a temps d'écho ultra-court (UTE) a été développée pour la visualisation in vivo des calcifications des artères coronariennes. Des études récentes ont démontré que les acquisitions UTE permettent de visualiser les calcifications dans des plaques athérosclérotiques ex vivo. Cepandent le mouvement du coeur a entravé jusqu'à maintenant l'utilisation des techniques UTE in vivo. Pour résoudre ce problème nous avons développé une séquence d'acquisition UTE avec trajectoire radiale 3D et l'avons testée sur des volontaires. La technique proposée utilise une auto-navigation 3D pour corriger le mouvement respiratoire et est synchronisée avec l'ECG. Trois échos sont acquis pour extraire le signal de la calcification avec des composants au T2 très court tout en permettant de séparer le signal de la graisse depuis le signal de l'eau. Les résultats sont encore préliminaires mais on peut affirmer que la technique développé peut potentiellement montrer les calcifications des artères coronariennes in vivo. En conclusion, ce travail de thèse présente trois nouvelles techniques pour l'IRM du coeur entier capables d'améliorer la visualisation et la caractérisation de la maladie athérosclérotique des coronaires. Ces techniques fournissent des informations anatomiques et fonctionnelles en quatre dimensions et des informations sur la composition du tissu auparavant indisponibles. CORONARY artery magnetic resonance imaging (MRI) has the potential to provide the cardiologist with relevant diagnostic information relative to coronary artery disease of patients. The major challenge of cardiac MRI, though, is dealing with all sources of motions that can corrupt the images affecting the diagnostic information provided. The current thesis, thus, focused on the development of new MRI techniques that change the standard approach to cardiac motion compensation in order to increase the efficiency of cardioavscular MRI, to provide more flexibility and robustness, new temporal information and new tissue information. The proposed approaches help in advancing coronary magnetic resonance angiography (MRA) in the direction of an easy-to-use and multipurpose tool that can be translated to the clinical environment. The first part of the thesis focused on the study of coronary artery motion through gold standard imaging techniques (x-ray angiography) in patients, in order to measure the precision with which the coronary arteries assume the same position beat after beat (coronary artery repositioning). We learned that intervals with minimal coronary artery repositioning occur in peak systole and in mid diastole and we responded with a new pulse sequence (T2~post) that is able to provide peak-systolic imaging. Such a sequence was tested in healthy volunteers and, from the image quality comparison, we learned that the proposed approach provides coronary artery visualization and contrast-to-noise ratio (CNR) comparable with the standard acquisition approach, but with increased signal-to-noise ratio (SNR). The second part of the thesis explored a completely new paradigm for whole- heart cardiovascular MRI. The proposed techniques acquires the data continuously (free-running), instead of being triggered, thus increasing the efficiency of the acquisition and providing four dimensional images of the whole heart, while respiratory self navigation allows for the scan to be performed in free breathing. This enabling technology allows for anatomical and functional evaluation in four dimensions, with high spatial and temporal resolution and without the need for contrast agent injection. The enabling step is the use of a golden-angle based 3D radial trajectory, which allows for a continuous sampling of the k-space and a retrospective selection of the timing parameters of the reconstructed dataset. The free-running 4D acquisition was then combined with a compressed sensing reconstruction algorithm that further increases the temporal resolution of the 4D dataset, while at the same time increasing the overall image quality by removing undersampling artifacts. The obtained 4D images provide visualization of the whole coronary artery tree in each phases of the cardiac cycle and, at the same time, allow for the assessment of the cardiac function with a single free- breathing scan. The quality of the coronary arteries provided by the frames of the free-running 4D acquisition is in line with the one obtained with the standard ECG-triggered one, and the cardiac function evaluation matched the one measured with gold-standard stack of 2D cine approaches. Finally, the last part of the thesis focused on the development of ultrashort echo time (UTE) acquisition scheme for in vivo detection of calcification in the coronary arteries. Recent studies showed that UTE imaging allows for the coronary artery plaque calcification ex vivo, since it is able to detect the short T2 components of the calcification. The heart motion, though, prevented this technique from being applied in vivo. An ECG-triggered self-navigated 3D radial triple- echo UTE acquisition has then been developed and tested in healthy volunteers. The proposed sequence combines a 3D self-navigation approach with a 3D radial UTE acquisition enabling data collection during free breathing. Three echoes are simultaneously acquired to extract the short T2 components of the calcification while a water and fat separation technique allows for proper visualization of the coronary arteries. Even though the results are still preliminary, the proposed sequence showed great potential for the in vivo visualization of coronary artery calcification. In conclusion, the thesis presents three novel MRI approaches aimed at improved characterization and assessment of atherosclerotic coronary artery disease. These approaches provide new anatomical and functional information in four dimensions, and support tissue characterization for coronary artery plaques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.