972 resultados para Computer Controlled Signals.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A participative ergonomics approach to reducing injuries associated with manual tasks is widely promoted; however only limited evidence from uncontrolled trials has been available to support the efficacy of such an approach. This paper reports on a randomized and controlled trial of PErforM, a participative ergonomics intervention designed to reduce the risks of injury associated with manual tasks. One hundred and seventeen small to medium sized food, construction, and health workplaces were audited by government inspectors using a manual tasks risk assessment tool (ManTRA). Forty-eight volunteer workplaces were then randomly assigned to Experimental and Control groups with the Experimental group receiving the PErforM program. Inspectors audited the workplaces again, 9 months following the intervention. The results showed a significant decrease in estimates of manual task risk and suggested better legal compliance in the Experimental group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A narrow absorption feature in an atomic or molecular gas (such as iodine or methane) is used as the frequency reference in many stabilized lasers. As part of the stabilization scheme an optical frequency dither is applied to the laser. In optical heterodyne experiments, this dither is transferred to the RF beat signal, reducing the spectral power density and hence the signal to noise ratio over that in the absence of dither. We removed the dither by mixing the raw beat signal with a dithered local oscillator signal. When the dither waveform is matched to that of the reference laser the output signal from the mixer is rendered dither free. Application of this method to a Winters iodine-stabilized helium-neon laser reduced the bandwidth of the beat signal from 6 MHz to 390 kHz, thereby lowering the detection threshold from 5 pW of laser power to 3 pW. In addition, a simple signal detection model is developed which predicts similar threshold reductions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The XSophe-Sophe-XeprView((R)) computer simulation software suite enables scientists to easily determine spin Hamiltonian parameters from isotropic, randomly oriented and single crystal continuous wave electron paramagnetic resonance (CW EPR) spectra from radicals and isolated paramagnetic metal ion centers or clusters found in metalloproteins, chemical systems and materials science. XSophe provides an X-windows graphical user interface to the Sophe programme and allows: creation of multiple input files, local and remote execution of Sophe, the display of sophelog (output from Sophe) and input parameters/files. Sophe is a sophisticated computer simulation software programme employing a number of innovative technologies including; the Sydney OPera HousE (SOPHE) partition and interpolation schemes, a field segmentation algorithm, the mosaic misorientation linewidth model, parallelization and spectral optimisation. In conjunction with the SOPHE partition scheme and the field segmentation algorithm, the SOPHE interpolation scheme and the mosaic misorientation linewidth model greatly increase the speed of simulations for most spin systems. Employing brute force matrix diagonalization in the simulation of an EPR spectrum from a high spin Cr(III) complex with the spin Hamiltonian parameters g(e) = 2.00, D = 0.10 cm(-1), E/D = 0.25, A(x) = 120.0, A(y) = 120.0, A(z) = 240.0 x 10(-4) cm(-1) requires a SOPHE grid size of N = 400 (to produce a good signal to noise ratio) and takes 229.47 s. In contrast the use of either the SOPHE interpolation scheme or the mosaic misorientation linewidth model requires a SOPHE grid size of only N = 18 and takes 44.08 and 0.79 s, respectively. Results from Sophe are transferred via the Common Object Request Broker Architecture (CORBA) to XSophe and subsequently to XeprView((R)) where the simulated CW EPR spectra (1D and 2D) can be compared to the experimental spectra. Energy level diagrams, transition roadmaps and transition surfaces aid the interpretation of complicated randomly oriented CW EPR spectra and can be viewed with a web browser and an OpenInventor scene graph viewer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objectives were to determine the postural consequences of varying computer monitor height and to describe self-selected monitor heights and postures. Design: The design involved experimental manipulation of computer monitor height, description of self-selected heights, and measurement of posture and gaze angles. Background. Disagreement exists with regard to the appropriate height of computer monitors. It is known that users alter both head orientation and gaze angle in response to changes in monitor height; however the relative contribution of atlanto-occipital and cervical flexion to the change in head rotation is unknown. No information is available with regard to self-selected monitor heights. Methods. Twelve students performed a tracking task with the monitor placed at three different heights. The subjects then completed eight trials in which monitor height was first self-selected. Sagittal postural and gaze angle data were determined by digitizing markers defining a two-dimensional three-link model of the trunk, cervical spine and head. Results. The 27 degrees change in monitor height imposed was, on average, accommodated by 18 degrees of head inclination and a 9 degrees change in gaze angle relative to the head. The change in head inclination was achieved by a 6 degrees change in trunk inclination, a 4 degrees change in cervical flexion, and a 7 degrees change in atlanto-occipital flexion. The self-selected height varied depending on the initial monitor height and inclination. Conclusions. Self-selected monitor heights were lower than current 'eye-level' recommendations. Lower monitor heights are likely to reduce both visual and musculoskeletal discomfort. Relevance Musculoskeletal and visual discomfort may be reduced by placing computer monitors lower than currently recommended. (C) 1998 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the effect of an early intervention program in an acute care setting on the length of stay in hospital of elderly patients with proximal femoral fractures. Setting: Acute orthopaedic ward of a large teaching hospital. Design and Participants: A randomised controlled trial comparing 38 intervention patients with 33 Standard Care patients. Intervention: Early surgery, minimal narcotic analgesia, intense daily therapy and close monitoring of patient needs via a multidisciplinary approach versus routine hospital management. Main outcome measures: Length of stay (LOS); deaths; level of independent functioning. Results: Mean LOS was shorter in the Intervention group than in the Standard Care group (21 days v. 32.5 days; P<0.01). After adjusting for other factors that could affect LOS (e.g. age, sex, pre-trauma functional levels, pre-trauma comorbidity and postsurgical complications), the Intervention program was significantly predictive of shorter LOS (P=0.01). The Intervention group did not experience greater numbers of deaths, deterioration in function or need for social support than the Standard Care group. Conclusion: This early intervention program in an acute care setting results in significantly shorter length of hospital stay for elderly patients with femoral fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider two different kinds of fluctuations in an ion trap potential: external fluctuating electrical fields, which cause statistical movement (wobbling) of the ion relative to the center of the trap, and fluctuations of the spring constant, which an due to fluctuations of the ac component of the potential applied in the Paul trap for ions. We write down master equations for both cases and, averaging out the noise, obtain expressions for the heating of the ion. We compare our results to previous results for far-off resonance optical traps and heating in ion traps. The effect of fluctuating external electrical fields for a quantum gate operation (controlled-NOT) is determined and the fidelity for that operation derived. [S1050-2947(99)06005-9].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RWMODEL II simulates the Rescorla-Wagner model of Pavlovian conditioning. It is written in Delphi and runs under Windows 3.1 and Windows 95. The program was designed for novice and expert users and can be employed in teaching, as well as in research. It is user friendly and requires a minimal level of computer literacy but is sufficiently flexible to permit a wide range of simulations. It allows the display of empirical data, against which predictions from the model can be validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel method of performing quantum logic gates in trapped ion quantum computers which does not require the ions to be cooled down to the ground state of their vibrational modes, thereby avoiding one of the principal experimental difficulties encountered in realizing this technology. Our scheme employs adiabatic passages and a phase shift conditional on the phonon number state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Multicenter Australian Study of Epidural Anesthesia and Analgesia in Major Surgery (The MASTER Trial) was designed to evaluate the possible benefit of epidural block in improving outcome in high-risk patients. The trial began in 1995 and is scheduled to reach the planned sample size of 900 during 2001. This paper describes the trial design and presents data comparing 455 patients randomized in 21 institutions in Australia, Hong Kong, and Malaysia, with 237 patients from the same hospitals who were eligible but not randomized. Nine categories of high-risk patients were defined as entry criteria for the trial. Protocols for ethical review, informed consent, randomization, clinical anesthesia and analgesia, and perioperative management were determined following extensive consultation with anesthesiologists throughout Australia. Clinical and research information was collected in participating hospitals by research staff who may not have been blind to allocation. Decisions about the presence or absence of endpoints were made primarily by a computer algorithm, supplemented by blinded clinical experts. Without unblinding the trial, comparison of eligibility criteria and incidence of endpoints between randomized and nonrandomized patients showed only small differences. We conclude that there is no strong evidence of important demographic or clinical differences between randomized and nonrandomized patients eligible for the MASTER Trial. Thus, the trial results are likely to be broadly generalizable. Control Clin Trials 2000;21:244-256 (C) Elsevier Science Inc. 2000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two-step method of loading controlled amounts of transition metal cations into alumina pillared clays (Al-PILCs) is proposed. First, calcined Al-PILC was dispersed into an aqueous solution of sodium or ammonium ions. Increasing the pH of the dispersion resulted in an increase in the amount of cations loaded into the clay. The ion-doped Al-PILC was then exchanged with an aqueous solution of transition metal salt at a pH of similar to 4.5 to replace Na+ or NH4+ ions by transition metal cations. Analytical techniques such as atomic absorption spectroscopy, X-ray diffraction, diffuse reflectance-ultraviolet-visible spectroscopy, as well as N-2 adsorption were used to characterize the PILC products with and without the loading of metal ions. The introduced transition metal species exist in the forms of hydrated ions in the PILC hosts. The content of transition metal ions in the final product increased with the amount of Na+ or NH4+ loaded in the first step so that by controlling the pH of the dispersion in the first step, one can control the doping amounts of transition metal cations into Al-PILCs. A sample containing 0.125 mmol/g of nickel was thus obtained, which is similar to 3 times of that obtained by directly exchanging Al-PILC with Ni(NO3)(2) solution, while the pillared layered structures of the Al-PILC remained. The porosity analysis using N-2 adsorption data indicated that most of the doped transition metal ions dispersed homogeneously in the micropores of the Al-PILC, significantly affecting the micropore structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of initial perturbation geometry and material propel-ties on final fold geometry has been investigated using finite-difference (FLAC) and finite-element (MARC) numerical models. Previous studies using these two different codes reported very different folding behaviour although the material properties, boundary conditions and initial perturbation geometries were similar. The current results establish that the discrepancy was not due to the different computer codes but due to the different strain rates employed in the two previous studies (i.e. 10(-6) s(-1) in the FLAC models and 10(-14) s(-1) in the MARC models). As a result, different parts of the elasto-viscous rheological field were bring investigated. For the same material properties, strain rate and boundary conditions, the present results using the two different codes are consistent. A transition in Folding behaviour, from a situation where the geometry of initial perturbation determines final fold shape to a situation where material properties control the final geometry, is produced using both models. This transition takes place with increasing strain rate, decreasing elastic moduli or increasing viscosity (reflecting in each case the increasing influence of the elastic component in the Maxwell elastoviscous rheology). The transition described here is mechanically feasible but is associated with very high stresses in the competent layer (on the order of GPa), which is improbable under natural conditions. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To demonstrate the impact on perinatal mortality of inadequate treatment for maternal syphilis despite adequate screening. METHOD In 12 clinics providing antenatal care in Hlabisa, South Africa 1783 pregnant women were screened for syphilis at their first antenatal visit between June and October 1998. Pregnancy outcome was determined among those with syphilis. RESULTS A total of 158 women were diagnosed with syphilis: prevalence 9% (95% CI 8-10%). Mean gestation at first antenatal visit was 24 weeks. Thirty women (19%) received no treatment and 96 (61%) received all three recommended doses of penicillin. Among those receiving at least one dose, mean delay to the first dose was 20 days. Among those fully treated mean delay to treatment completion was 34 days. Pregnancy outcome was known for 142 women (90%) and there were 17 perinatal deaths among 15 women (11%). Eleven of 43 women (26%) who received one or fewer doses of penicillin experienced ii perinatal death whilst only four of 99 women (4%) who received two or more doses of penicillin did so (P = 0.0001). Protection from perinatal death increased with the number of doses of penicillin: linear modelling suggests that one dose reduced the risk by 41%, two doses by 65% and three doses by 79%, compared with no doses. A dose-specific, categorical model confirmed reduction in risk by 79% for all three doses. CONCLUSION Despite effective screening, many pregnant women with syphilis remain inadequately treated, resulting in avoidable perinatal mortality. Delays in starting and finishing treatment, as well as incomplete treatment occur. Near-patient syphilis testing in the antenatal clinic with early treatment could improve treatment of syphilis and reduce perinatal mortality, and a randomized trial to test this is underway.