993 resultados para Composite resins - Dental leakage
Resumo:
The therapeutic management of tooth wear lesions does not require the removal of diseased tissue. Nevertheless, diverse etiological factors may be associated with the condition and they could be difficult to eliminate; this has to be considered when planning therapy. Interceptive procedures should be reserved for such situations while regular monitoring is recommended for other cases, in accordance with advice provided for using the Basic Erosive Wear Examination (BEWE). Direct and indirect adhesive procedures with composite resins allow treatment of most clinical situations, including even extensive restorations. The possibility of managing subsequent interventions should be considered when planning the initial therapeutic approach.
Resumo:
La odontología está inmersa en un nuevo paradigma: no se puede pensar en ninguna técnica restauradora sin que participen fenómenos de adhesión. El desarrollo de pernos de fibra de vidrio, sumado a los procedimientos de restauraciones adhesivas puede utilizarse como uno de los tantos recursos de la odontología de invasión mínima. Los pernos de fibra de vidrio ofrecen varias ventajas: comportamiento anisótropo, módulo de elasticidad bajo, buena resistencia mecánica, el lecho que aloja al perno de fibra requiere de una mínima preparación y se cementan con cementos adhesivos con carga, permitiendo de esta manera obtener una superficie homogénea que se interpone entre el perno de fibra y los tejidos dentales, conectándolo a los tejidos del conducto y sustituyendo mecánicamente la dentina. El caso clínico que se reporta se presentó para su resolución en la Clínica Integrada III F. O. UNCuyo durante el año lectivo 2009. El paciente presentaba una fractura amelodentinaria desde hacía cuatro años, con compromiso de la vitalidad y un proceso periapical. Durante los procedimientos endodónticos se realizó una perforación de la pared del conducto que se selló mediante la colocación de hidróxido de calcio y la obturación del mismo con conos de gutapercha. Se efectuó el seguimiento clínico y radiográfico del caso en donde se constató la reparación del proceso apical y luego se procedió a la restauración del elemento dentario con resinas compuestas con la ayuda de un poste de fibra de vidrio cementado con cemento resinoso. Dadas las características del tratamiento endodóntico realizado, se decidió dejar más porción del cono de gutapercha a pesar de lo aconsejado por numerosos autores, ya que de esta manera se aseguró el sellado de la perforación radicular para evitar de esta manera la nanofiltración hacia el interior del elemento dentario.
Resumo:
La operatoria dental actual cuenta con un conocimiento más profundo de las diferentes estructuras dentarias que sumado al gran adelanto tecnológico y científico en la ciencia de los biomateriales; fruto de innumerables investigaciones, nos permiten contar hoy, con una nueva generación de materiales restauradores, lo que hace más crítico y exigente el conocimiento y análisis por parte del profesional, de las técnicas a efectuar, la realización depurada de procedimientos y los biomateriales a utilizar, con el fin de realizar tratamientos que sean biocompatibles, eficientes y de importante longevidad.
Resumo:
Lesões dentais por erosão têm sido cada vez mais presentes na prática clínica. A restauração direta com resina composta é uma das opções de tratamento para lesões severas, em que há comprometimento estético/funcional. Com o aprimoramento da tecnologia, a utilização do laser para pré-tratamento da superfície dentinária, antes do condicionamento ácido, tem sido considerada como método alternativo para melhorar a adesão das resinas compostas às superfícies erodidas. Assim, o objetivo deste estudo in vitro foi avaliar a influência da irradiação com laser de Er:YAG (2,94 ?m), de pulso super-curto, na adesão da resina composta à superfície dentinária erodida. Quarenta e seis discos de dentina foram obtidos a partir de 46 dentes terceiros molares humanos. A dentina oclusal planificada de 40 molares humanos teve metade de sua face protegida com fita UPVC (dentina hígida), enquanto na outra metade foi produzida uma lesão de erosão através da ciclagem em ácido cítrico (0,05 M, pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Metade das amostras foi irradiada com o laser de Er:YAG (50 ?s, 2 Hz, 80 mJ, 12,6 J/cm2) e a outra não (grupo controle). Em cada grupo de tratamento (laser ou controle) (n=10), um sistema adesivo autocondicionante foi utilizado e, então, confeccionados 2 cilindros de resina composta, tanto do lado erodido como no hígido (total de 4 cilindros), os quais foram submetidos à avaliação da Resistência de União através do ensaio de microcisalhamento (1 mm/min), após armazenamento em saliva artificial por 24 h. A análise do padrão de fratura foi realizada em microscópio óptico (40x). Por meio da Microscopia Eletrônica de Varredura (MEV), a morfologia das superfícies dentinárias hígida e submetida ao desafio erosivo, antes e após o tratamento com laser de Er:YAG (n=3), foi avaliada. Os valores obtidos de resistência de união (MPa) foram submetidos ao teste ANOVA e de comparações múltiplas de Tukey (p<0,05) e as análises das eletromicrografias foram feitas de forma descritiva. A análise morfológica da superfície mostrou alterações significativas na dentina hígida irradiada e na submetida à ciclagem erosiva, irradiada ou não. Quanto à resistência de união, houve diferença entre os 4 substratos analisados, sendo: dentina hígida irradiada (12,77±5,09 A), dentina hígida não irradiada (9,76±3,39 B), dentina erodida irradiada (7,62±3,39 C) e dentina erodida não irradiada (5,12±1,72 D). Houve predominância de padrão de fratura do tipo adesiva. Com base nos resultados e nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que a erosão reduz a adesão em dentina e que o tratamento da superfície dentinária com laser de Er:YAG de largura de pulso super curta aumenta a adesão no substrato erodido ou hígido.
Resumo:
Aim: To assess in vitro the surface roughness (Ra), Vickers hardness (VHN) and surface morphology of resin and glass ionomer materials used for sealants after dynamic erosive challenge. Methods: Twenty specimens of each material were prepared and divided into experimental (erosive challenge) and control groups (n=10): Protect Riva (SDI), Opallis Flow (3M ESPE), Fluroshield (Dentsply), Filtek Z350 XT Flow (3M ESPE). The erosive challenge was performed 4 times per day (90 s) in cola drink and for 2 h in artificial saliva for 7 days. The control specimens were maintained in artificial saliva. Ra and VHN readings were performed before and after erosion. The percentage of hardness loss (%VHN) was obtained after erosion. The surface morphology was evaluated by scanning electron microscopy (SEM). The data were analyzed by ANOVA, Tukey and paired t tests (α=0.05). Results: After erosion and saliva immersion, there was an increase in Ra values for all groups and Riva group showed the highest Ra values. After erosive challenge, Riva and Filtek groups showed significant decrease in VHN values, but Filtek group showed the greatest %VHN. For all groups there was inorganic particle protrusion and matrix degradation after erosion visualized by SEM images. Conclusions: Erosive challenge affected the surface properties of all materials used as sealants, particularly in the Riva and Filtek groups.
Resumo:
Aim: To evaluate the clinical performance of a composite resin (CR) and a resin-modified glassionomer cement (RMGIC) for the treatment of abfraction lesions. Methods: Thirty patients with abfraction lesions in at least two premolar teeth were selected and invited to participate in this study. All restorations were made within the same clinical time frame. One tooth was restored with CR Z100TM (3M, St. Paul, MN, USA), and the other was restored with RMGIC VitremerTM (3M). The restorations were assessed immediately and 1, 6 and 12 months after the restoration, using modified US Public Health Service (USPHS) criteria: marginal integrity, marginal discoloration, wear, retention, secondary caries and hypersensitivity. The statistical analysis was based on Friedman ANOVA test and Mann-Whitney test, considering p<0.05 for statistical significance. Results: Both materials demonstrated satisfactory clinical performance after one year. In the individual analysis of each material, there was a significant difference (p<0.05) in the criteria marginal integrity and wear, for both CR and RMGIC. RMGIC exhibited more damage one year after the restoration. Comparing both materials, it was found a significant difference only for marginal discoloration, while the RMGIC restorations showed the worst prognosis after a year of evaluation. There was no significant difference in the number of retentions, caries or hypersensitivity between CR and RMGIC. Conclusions: It was concluded that CR exhibited the best clinical performance according to the cost-effectiveness and evaluation criteria used in this study.
Resumo:
To evaluate the surface roughness of acrylic resin submitted to chemical disinfection via 1% sodium hypochlorite (NaClO) or 1% peracetic acid (C2H4O3). The disc-shaped resin specimens (30 mm diameter ×4 mm height) were polymerized by heated water using two cycles (short cycle: 1 h at 74°C and 30 min at 100°C; conventional long cycle: 9 h at 74°C). The release of substances by these specimens in water solution was also quantified. Specimens were fabricated, divided into four groups (n = 10) depending on the polymerization time and disinfectant. After polishing, the specimens were stored in distilled deionized water. Specimens were immersed in 1% NaClO or 1% C2H4O3 for 30 min, and then were immersed in distilled deionized water for 20 min. The release of C2H4O3 and NaClO was measured via visual colorimetric analysis. Roughness was measured before and after disinfection. Roughness data were subjected to two-way ANOVA and Tukey's test. There was no interaction between polymerization time and disinfectant in influencing the average surface roughness (Ra, P = 0.957). Considering these factors independently, there were significant differences between short and conventional long cycles (P = 0.012), but no significant difference between the disinfectants hypochlorite and C2H4O3 (P = 0.366). Visual colorimetric analysis did not detect release of substances. It was concluded that there was the difference in surface roughness between short and conventional long cycles, and disinfection at acrylic resins polymerized by heated water using a short cycle modified the properties of roughness.
Correlation between margin fit and microleakage in complete crowns cemented with three luting agents
Resumo:
Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.
Resumo:
Owing to improvements in its mechanical properties and to the availability of shade and translucence resources, resin composite has become one of the most widely used restorative materials in present day Dentistry. The aim of this study was to assess the relation between the surface hardness of seven different commercial brands of resin composites (Charisma, Fill Magic, Master Fill, Natural Look, Opallis, Tetric Ceram, and Z250) and the different degrees of translucence (translucid, enamel and dentin). Vickers microhardness testing revealed significant differences among the groups. Z250 was the commercial brand that showed the best performance in the hardness test. When comparing the three groups assessed within the same brand, only Master Fill and Fill Magic presented statistically significant differences among all of the different translucencies. Natural Look was the only one that showed no significant difference among any of the three groups. Charisma, Opallis, Tetric Ceram and Z250 showed significant differences among some of the tested groups. Based on the results found in this study, it was not possible to establish a relation between translucence and the microhardness of the resin composites assessed. Depending on the material assessed, however, translucence variation did affect the microhardness values of the resin composites.
Resumo:
Objective: This study aimed to analyze in vitro inhibitory effects of restorative materials containing the antibacterial monomer 12-methacryloyloxydodecylpyridinium bromide (MDPB) on the formation of artificial secondary root caries lesions. Methods: Class V cavities (2 mm x 2 mm) were prepared in 75 human root fragments. Specimens were randomly divided into five groups (n = 15 fragments per group) and restored as follows: (I) MDPB-free adhesive system + MDPB-free composite (negative control); (II) resin modified glass ionomer (RM-GIC; positive control); (III) MDPB-free adhesive system + MDPB-containing composite (2.83% MDPB); (IV) MDPB-containing adhesive system + MDPB-free composite; M MDPB-containing adhesive system + MDPB-containing composite. Artificial secondary root caries lesions were produced by a biological artificial caries challenge. The restored specimens were immersed into a culture medium containing Streptococcus mutans and sucrose for 15 days. Histological slices (80 +/- 20 mu m) of the specimens were used for measuring the mean depths of the artificial lesions produced in both margins of the restorations using polarized light microscopy. Results were expressed in percentage related to the mean depth of the negative control, considered 100%. Data were compared by ANOVA followed by the Tukey`s test (p <= 0.05). Results: The depths of lesions adjacent to cavities filled with RM-GIC (GII; 85.17 +/- 15.2%) were significantly (p < 0.01) shallower than those adjacent to restorations with MDPB-free composite (GI; 100.00 +/- 10.04%), despite the presence of MDPB in the adhesive system (GIV; 101.95 +/- 21.32%). The depths of lesions adjacent to cavities restored with MDPB-containing composite (GIII; 82.68 +/- 12.81% and GV; 85.65 +/- 15.42%), despite the adhesive system used, were similar to those of RM-GIC (GII). Mean lesions depths in these groups decreased from 13% (GV) to 17% (GIII) in relation to the negative control (GI). Conclusions: MDPB-containing composite inhibits the progression of artificial secondary root caries lesions regardless of adhesive systems. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: This study analyzed the surface roughness and weight loss in Plex Glass specimens caused by dentifrices, one conventional (Sorriso) and three specific for dentures. Materials and Methods: Specimens (n = 6) of Plex Glass were divided into 5 groups including: negative control (water); positive control 1 (Sorriso) and 2 (Corega Brite); Experimental 1 (containing Chloramine T, antimicrobial agent); and Experimental 2 (containing Zonyl, detergent). Brushing was performed in a toothbrushing machine (Pepsodent) with a soft brush and a suspension of toothpaste and distilled water for 300 minutes, representing 6 years of brushing. Weight was measured initially and after the trial period; roughness was measured after the trial period only. The results of roughness and weight loss were analyzed using ANOVA and Tukey tests at 5%. Results: The negative control (2.82 +/- 4.41 mg) showed the lowest weight loss. Experimental 1 (13.62 +/- 4.29 mg) and Experimental 2 (15.4 +/- 5.80 mg) were equal statistically, and Sorriso (23.22 +/- 7.23 mg) and Corega (28.83 +/- 6.34 mg) produced the greatest weight loss. Concerning roughness, the negative control group (0.03 +/- 0.01 mu m) showed the lowest value. No significant differences were found between Corega (13.43 +/- 1.65 mu m), Experimental 1 (12.28 +/- 0.85 mu m), and Experimental 2 (10.68 +/- 2.56 mu m). The Sorriso toothpaste produced the greatest amount of surface roughness (19.15 +/- 2.36 mu m). Conclusion: Of the tested dentifrices, the experimental preparations proved to be the least abrasive and resulted in the lowest weight loss after brushing of the acrylic. Based on these findings, the use of these experimental dentifrices is advocated. Further evaluation based on the ability of these preparations to remove biofilms is required.
Resumo:
The neuronal monocarboxylate transporter, MCT2, is not only an energy substrate carrier but it is also purported to be a binding partner for the alpha-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) receptor GluR2 subunit. To unravel a putative role of MCT2 in the regulation of GluR2 subcellular distribution, Neuro2A cells and primary cultures of mouse cortical neurons were co-transfected with plasmids containing sequences to express the fluorescent proteins mStrawberry (mStb)-fused MCT2 and Venus-fused GluR2. Subsequently, their subcellular distribution was visualized by fluorescence microscopy. GluR2 was led to form perinuclear and dendritic clusters together with MCT2 when co-transfected in Neuro2A cells or in neurons, following the original distribution of MCT2. MCT2 co-transfection had no effect on the intracellular distribution of several other post-synaptic proteins, although it partially affected the intracellular distribution of GluR1 similarly to GluR2. Both cell surface and total protein expression levels of GluR2 were significantly reduced by co-expression with MCT2. Finally, partial perinuclear and dendritic co-localization between MCT2 and Rab8, a member of the small GTPase family involved in membrane trafficking of AMPA receptors, was also observed in co-transfected neurons. These results suggest that MCT2 could influence AMPA receptor trafficking within neurons by modulating GluR2 sorting between different subcellular compartments.
Resumo:
Nous avons fait un examen clinique de 30 cas de contention postorthodontique avec attelle rigide en résine, de canine à canine sur les deux maxillaires. On décrit la fabrication de l'attelle, sa mise en place, les incidents possibles ou les problèmes cliniques apparus (mauvaise adhérence, gingivite ...) et les aspects psychologiques ou subjectifs du patient
Resumo:
PURPOSE: To meta-analyze the literature on the clinical performance of Class V restorations to assess the factors that influence retention, marginal integrity, and marginal discoloration of cervical lesions restored with composite resins, glass-ionomer-cement-based materials [glass-ionomer cement (GIC) and resin-modified glass ionomers (RMGICs)], and polyacid-modified resin composites (PMRC). MATERIALS AND METHODS: The English literature was searched (MEDLINE and SCOPUS) for prospective clinical trials on cervical restorations with an observation period of at least 18 months. The studies had to report about retention, marginal discoloration, marginal integrity, and marginal caries and include a description of the operative technique (beveling of enamel, roughening of dentin, type of isolation). Eighty-one studies involving 185 experiments for 47 adhesives matched the inclusion criteria. The statistical analysis was carried out by using the following linear mixed model: log (-log (Y /100)) = β + α log(T ) + error with β = log(λ), where β is a summary measure of the non-linear deterioration occurring in each experiment, including a random study effect. RESULTS: On average, 12.3% of the cervical restorations were lost, 27.9% exhibited marginal discoloration, and 34.6% exhibited deterioration of marginal integrity after 5 years. The calculation of the clinical index was 17.4% of failures after 5 years and 32.3% after 8 years. A higher variability was found for retention loss and marginal discoloration. Hardly any secondary caries lesions were detected, even in the experiments with a follow-up time longer than 8 years. Restorations placed using rubber-dam in teeth whose dentin was roughened showed a statistically significantly higher retention rate than those placed in teeth with unprepared dentin or without rubber-dam (p < 0.05). However, enamel beveling had no influence on any of the examined variables. Significant differences were found between pairs of adhesive systems and also between pairs of classes of adhesive systems. One-step self-etching had a significantly worse clinically index than two-step self-etching and three-step etch-and-rinse (p = 0.026 and p = 0.002, respectively). CONCLUSION: The clinical performance is significantly influenced by the type of adhesive system and/or the adhesive class to which the system belongs. Whether the dentin/enamel is roughened or not and whether rubberdam isolation is used or not also significantly influenced the clinical performance. Composite resin restorations placed with two-step self-etching and three-step etch-and-rinse adhesive systems should be preferred over onestep self-etching adhesive systems, GIC-based materials, and PMRCs.
Resumo:
The aim of this study was to assess in vitro the influence of Er:YAG laser irradiation distance on the shear strength of the bond between an adhesive restorative system and primary dentin. A total of 60 crowns of primary molars were embedded in acrylic resin and mechanically ground to expose a flat dentin surface and were randomly assigned to six groups (n = 10). The control group was etched with 37% phosphoric acid. The remaining five groups were irradiated (80 mJ, 2 Hz) at different irradiation distances (11, 12, 16, 17 and 20 mm), followed by acid etching. An adhesive agent (Single Bond) was applied to the bonding sites, and resin cylinders (Filtek Z250) were prepared. The shear bond strength tests were performed in a universal testing machine (0.5 mm/min). Data were submitted to statistical analysis using one-way ANOVA and the Kruskal-Wallis test (p < 0.05). The mean shear bond strengths were: 7.32 +/- 3.83, 5.07 +/- 2.62, 6.49 +/- 1.64, 7.71 +/- 0.66, 7.33 +/- 0.02, and 9.65 +/- 2.41 MPa in the control group and the groups irradiated at 11, 12, 16, 17, and 20 mm, respectively. The differences between the bond strengths in groups II and IV and between the bond strengths in groups II and VI were statistically significant (p < 0.05). Increasing the laser irradiation distance resulted in increasing shear strength of the bond to primary dentin.