1000 resultados para Code validation
Resumo:
To further validate the doubly labeled water method for measurement of CO2 production and energy expenditure in humans, we compared it with near-continuous respiratory gas exchange in nine healthy young adult males. Subjects were housed in a respiratory chamber for 4 days. Each received 2H2(18)O at either a low (n = 6) or a moderate (n = 3) isotope dose. Low and moderate doses produced initial 2H enrichments of 5 and 10 X 10(-3) atom percent excess, respectively, and initial 18O enrichments of 2 and 2.5 X 10(-2) atom percent excess, respectively. Total body water was calculated from isotope dilution in saliva collected at 4 and 5 h after the dose. CO2 production was calculated by the two-point method using the isotopic enrichments of urines collected just before each subject entered and left the chamber. Isotope enrichments relative to predose samples were measured by isotope ratio mass spectrometry. At low isotope dose, doubly labeled water overestimated average daily energy expenditure by 8 +/- 9% (SD) (range -7 to 22%). At moderate dose the difference was reduced to +4 +/- 5% (range 0-9%). The isotope elimination curves for 2H and 18O from serial urines collected from one of the subjects showed expected diurnal variations but were otherwise quite smooth. The overestimate may be due to approximations in the corrections for isotope fractionation and isotope dilution. An alternative approach to the corrections is presented that reduces the overestimate to 1%.
Resumo:
Summary: Lipophilicity plays an important role in the determination and the comprehension of the pharmacokinetic behavior of drugs. It is usually expressed by the partition coefficient (log P) in the n-octanol/water system. The use of an additional solvent system (1,2-dichlorethane/water) is necessary to obtain complementary information, as the log Poct values alone are not sufficient to explain ail biological properties. The aim of this thesis is to develop tools allowing to predict lipophilicity of new drugs and to analyze the information yielded by those log P values. Part I presents the development of theoretical models used to predict lipophilicity. Chapter 2 shows the necessity to extend the existing solvatochromic analyses in order to predict correctly the lipophilicity of new and complex neutral compounds. In Chapter 3, solvatochromic analyses are used to develop a model for the prediction of the lipophilicity of ions. A global model was obtained allowing to estimate the lipophilicity of neutral, anionic and cationic solutes. Part II presents the detailed study of two physicochemical filters. Chapter 4 shows that the Discovery RP Amide C16 stationary phase allows to estimate lipophilicity of the neutral form of basic and acidic solutes, except of lipophilic acidic solutes. Those solutes present additional interactions with this particular stationary phase. In Chapter 5, 4 different IANI stationary phases are investigated. For neutral solutes, linear data are obtained whatever the IANI column used. For the ionized solutes, their retention is due to a balance of electrostatic and hydrophobie interactions. Thus no discrimination is observed between different series of solutes bearing the same charge, from one column to an other. Part III presents two examples illustrating the information obtained thanks to Structure-Properties Relationships (SPR). Comparing graphically lipophilicity values obtained in two different solvent systems allows to reveal the presence of intramolecular effects .such as internai H-bond (Chapter 6). SPR is used to study the partitioning of ionizable groups encountered in Medicinal Chemistry (Chapter7). Résumé La lipophilie joue un .rôle important dans la détermination et la compréhension du comportement pharmacocinétique des médicaments. Elle est généralement exprimée par le coefficient de partage (log P) d'un composé dans le système de solvants n-octanol/eau. L'utilisation d'un deuxième système de solvants (1,2-dichloroéthane/eau) s'est avérée nécessaire afin d'obtenir des informations complémentaires, les valeurs de log Poct seules n'étant pas suffisantes pour expliquer toutes les propriétés biologiques. Le but de cette thèse est de développer des outils permettant de prédire la lipophilie de nouveaux candidats médicaments et d'analyser l'information fournie par les valeurs de log P. La Partie I présente le développement de modèles théoriques utilisés pour prédire la lipophilie. Le chapitre 2 montre la nécessité de mettre à jour les analyses solvatochromiques existantes mais inadaptées à la prédiction de la lipophilie de nouveaux composés neutres. Dans le chapitre 3, la même méthodologie des analyses solvatochromiques est utilisée pour développer un modèle permettant de prédire la lipophilie des ions. Le modèle global obtenu permet la prédiction de la lipophilie de composés neutres, anioniques et cationiques. La Partie II présente l'étude approfondie de deux filtres physicochimiques. Le Chapitre 4 montre que la phase stationnaire Discovery RP Amide C16 permet la détermination de la lipophilie de la forme neutre de composés basiques et acides, à l'exception des acides très lipophiles. Ces derniers présentent des interactions supplémentaires avec cette phase stationnaire. Dans le Chapitre 5, 4 phases stationnaires IAM sont étudiées. Pour les composés neutres étudiés, des valeurs de rétention linéaires sont obtenues, quelque que soit la colonne IAM utilisée. Pour les composés ionisables, leur rétention est due à une balance entre des interactions électrostatiques et hydrophobes. Donc aucune discrimination n'est observée entre les différentes séries de composés portant la même charge d'une colonne à l'autre. La Partie III présente deux exemples illustrant les informations obtenues par l'utilisation des relations structures-propriétés. Comparer graphiquement la lipophilie mesurée dans deux différents systèmes de solvants permet de mettre en évidence la présence d'effets intramoléculaires tels que les liaisons hydrogène intramoléculaires (Chapitre 6). Cette approche des relations structures-propriétés est aussi appliquée à l'étude du partage de fonctions ionisables rencontrées en Chimie Thérapeutique (Chapitre 7) Résumé large public Pour exercer son effet thérapeutique, un médicament doit atteindre son site d'action en quantité suffisante. La quantité effective de médicament atteignant le site d'action dépend du nombre d'interactions entre le médicament et de nombreux constituants de l'organisme comme, par exemple, les enzymes du métabolisme ou les membranes biologiques. Le passage du médicament à travers ces membranes, appelé perméation, est un paramètre important à optimiser pour développer des médicaments plus puissants. La lipophilie joue un rôle clé dans la compréhension de la perméation passive des médicaments. La lipophilie est généralement exprimée par le coefficient de partage (log P) dans le système de solvants (non miscibles) n-octanol/eau. Les valeurs de log Poct seules se sont avérées insuffisantes pour expliquer la perméation à travers toutes les différentes membranes biologiques du corps humain. L'utilisation d'un système de solvants additionnel (le système 1,2-dichloroéthane/eau) a permis d'obtenir les informations complémentaires indispensables à une bonne compréhension du processus de perméation. Un grand nombre d'outils expérimentaux et théoriques sont à disposition pour étudier la lipophilie. Ce travail de thèse se focalise principalement sur le développement ou l'amélioration de certains de ces outils pour permettre leur application à un champ plus large de composés. Voici une brève description de deux de ces outils: 1)La factorisation de la lipophilie en fonction de certaines propriétés structurelles (telle que le volume) propres aux composés permet de développer des modèles théoriques utilisables pour la prédiction de la lipophilie de nouveaux composés ou médicaments. Cette approche est appliquée à l'analyse de la lipophilie de composés neutres ainsi qu'à la lipophilie de composés chargés. 2)La chromatographie liquide à haute pression sur phase inverse (RP-HPLC) est une méthode couramment utilisée pour la détermination expérimentale des valeurs de log Poct.
Resumo:
BACKGROUND: The only available score to assess the risk for fatal bleeding in patients with venous thromboembolism (VTE) has not been validated yet. METHODS: We used the RIETE database to validate the risk-score for fatal bleeding within the first 3 months of anticoagulation in a new cohort of patients recruited after the end of the former study. Accuracy was measured using the ROC curve analysis. RESULTS: As of December 2011, 39,284 patients were recruited in RIETE. Of these, 15,206 had not been included in the former study, and were considered to validate the score. Within the first 3 months of anticoagulation, 52 patients (0.34%; 95% CI: 0.27-0.45) died of bleeding. Patients with a risk score of <1.5 points (64.1% of the cohort) had a 0.10% rate of fatal bleeding, those with a score of 1.5-4.0 (33.6%) a rate of 0.72%, and those with a score of >4 points had a rate of 1.44%. The c-statistic for fatal bleeding was 0.775 (95% CI 0.720-0.830). The score performed better for predicting gastrointestinal (c-statistic, 0.869; 95% CI: 0.810-0.928) than intracranial (c-statistic, 0.687; 95% CI: 0.568-0.806) fatal bleeding. The score value with highest combined sensitivity and specificity was 1.75. The risk for fatal bleeding was significantly increased (odds ratio: 7.6; 95% CI 3.7-16.2) above this cut-off value. CONCLUSIONS: The accuracy of the score in this validation cohort was similar to the accuracy found in the index study. Interestingly, it performed better for predicting gastrointestinal than intracranial fatal bleeding.
Resumo:
Rapport de synthèse: Enjeux et contexte de recherche : la coarctation de l'aorte, rétrécissement de l'aorte thoracique descendante, est une des malformations cardiaques congénitales les plus fréquentes. Son diagnostic reste cependant difficile surtout lorsqu'elle est associée à la présence d'un canal artériel ou à une malformation cardiaque plus complexe. Dans ces contextes, les signes échographiques classiques qui posent habituellement le diagnostic (visualisation d'un rétrécissement juxtaductal et accélération au Doppler au niveau de l'isthme aortique) peuvent faire défaut ou être difficile à imager. La validation d'index basé sur des mesures anatomiques faciles à acquérir par échographie cardiaque, indépendantes de l'âge, de la situation hémodynamique et des malformations cardiaques associées représente une aide significative dans le diagnostic de la coarctation de l'aorte. Nous avons donc voulu valider par une étude rétrospective la fiabilité de deux index dans cette indication : l'index des artères carotido-sous-clavière (index CSA; rapport du diamètre de l'arc aortique transverse distal sur la distance entre les artères carotide et sous-clavière gauches) et l'index de l'aorte isthmique-descendante (index I/D; rapport des diamètres de l'aorte isthmique sur celui de l'aorte descendante). Notre article : nous avons rétrospectivement calculé la valeur des deux index (CSA et I/D) chez un groupe de 68 enfants avec coarctation et un groupe 24 cas contrôles apparenté pour l'âge et le sexe. Les enfants avec coarctation ont un index CSA et I/D significativement plus bas que le groupe contrôle (Index CSA : 0.84 ± 0.39 vs. 2.65 ± 0.82, p<0.0001 - Index I/D : 0.58 ± 0.18 vs. 0.98 ± 0.19, p<0.0001). Pour les deux index, ni la présence d'une autre malformation cardiaque, ni l'âge n'ont un impact sur la différence significative entre les deux groupes. Conclusions: notre recherche à permis de valider qu'un index CSA de moins de 1,5 est fortement suggestif d'une coarctation, indépendamment de l'âge du patient et de la présence d'une autre malformation cardiaque. L'index I/D (valeur limite 0,64) est moins spécifique que l'index CSA. L'association des deux index augmente la sensibilité et permet rétrospectivement le diagnostic de tous les cas de coarctation seulement sur la base d'une échographie cardiaque standard faite au lit du patient. Perspectives : cette étude rétrospective mérite d'être vérifiée par une étude prospective afin de confirmer la contribution de ces index à la prise en charge des patients suspects d'une coarctation de l'aorte. Cependant, la situation dans laquelle ces index pourraient avoir le plus grand impact reste encore à explorer. En effet, si le diagnostic postnatal de la coarctation est parfois difficile, son diagnostic prénatal l'est nettement plus. La présence obligatoire du canal artériel et l'existence d'une hypoplasie isthmique physiologique chez le foetus obligent le cardiologue foetale à observer des signes indirects, peu sensibles, d'une possible coarctation (prépondérance des cavités droites). La validation de l'index CSA et/ou de l'index I/D chez le foetus constituerait donc une avancée majeure dans le diagnostic prénatal de la coarctation de l'aorte.
Resumo:
OBJECTIVE: The aim of the study was to validate a French adaptation of the 5th version of the Addiction Severity Index (ASI) instrument in a Swiss sample of illicit drug users. PARTICIPANTS AND SETTING: The participants in the study were 54 French-speaking dependent patients, most of them with opiates as the drug of first choice. Procedure: Analyses of internal consistency (convergent and discriminant validity) and reliability, including measures of test-retest and inter-observer correlations, were conducted. RESULTS: Besides good applicability of the test, the results on composite scores (CSs) indicate comparable results to those obtained in a sample of American opiate-dependent patients. Across the seven dimensions of the ASI, Cronbach's alpha ranged from 0.42 to 0.76, test-retest correlations coefficients ranged from 0.48 to 0.98, while for CSs, inter-observer correlations ranged from 0.76 to 0.99. CONCLUSIONS: Despite several limitations, the French version of the ASI presents acceptable criteria of applicability, validity and reliability in a sample of drug-dependent patients.
Resumo:
Cloud computing has recently become very popular, and several bioinformatics applications exist already in that domain. The aim of this article is to analyse a current cloud system with respect to usability, benchmark its performance and compare its user friendliness with a conventional cluster job submission system. Given the current hype on the theme, user expectations are rather high, but current results show that neither the price/performance ratio nor the usage model is very satisfactory for large-scale embarrassingly parallel applications. However, for small to medium scale applications that require CPU time at certain peak times the cloud is a suitable alternative.
Resumo:
IPH responded to the Department of Justice, Equality and Defence review of the voluntary Code of Practice for the display and sale of alcohol in supermarkets, convenience stores and similar mixed trading outlets. The voluntary Code was introduced in 2008 as an alternative to the statutory rules for structural separation of alcohol products in mixed trading outlets which are set out in section 9 of the Intoxicating Liquor Act 2008. Interested bodies and individuals were invited to submit comments on the Compliance Report for 2011 and on the effectiveness of the voluntary approach to structural separation by 20th December 2011. The Minister said he intended to also seek the views of the Minister for Health and the Joint Oireachtas Committee on Justice, Defence and Equality before reaching any decision on whether to bring the statutory rules in the 2008 Act into operation.
Resumo:
The Broadcasting Authority of Ireland (BAI) is an independent statutory organisation responsible for certain aspects of television and radio services in Ireland, guided by the Broadcasting Act 2009. The BAI are undertaking a review of the Children’s Commercial Communications Code section 11 rules on Diet and Nutrition. This section sets down standards with which commercial communications for food and drink shown during children’s programmes and/or where these communications are for food and drink products or services that are of special interest to children.