949 resultados para Church plate
Resumo:
Labor Historian Marc Karson has singled out “labor priest” Peter E. Dietz as one of the strongest proponents for the active implementation of the Catholic Church’s 1890’s labor encyclical Rerum Novarum in the daily practice of American Catholics. Biographer Sister Mary Harrita Fox pointed out that in his work, Dietz “was particularly concerned over the role of the church in the copper strike in Upper Michigan.” This “particular concern” should be noted since the 1913 strike was one of the only disputes where Dietz went out of his way to visit and become actively involved. Why the keen interest? This presentation will review the impetus for the huge effort which brought Peter E. Dietz to the Copper Country and solely to that dispute alone, the resulting visit and report that he made concerning the strike, the important role he believed this visit and stance in the Copper Strike had in the future of the Church’s relationship to the US labor movement. The presentation will look at both what Dietz thought would occur as a result of his 1913 trip to the Keweenaw and what actually happened in this pivotal pre-World War One era event. The paper will put Father Peter E. Dietz and the Catholic Church into the larger frame of how religion has been viewed within the history of the Strike.
Resumo:
Noise and vibration has long been sought to be reduced in major industries: automotive, aerospace and marine to name a few. Products must be tested and pass certain levels of federally regulated standards before entering the market. Vibration measurements are commonly acquired using accelerometers; however limitations of this method create a need for alternative solutions. Two methods for non-contact vibration measurements are compared: Laser Vibrometry, which directly measures the surface velocity of the aluminum plate, and Nearfield Acoustic Holography (NAH), which measures sound pressure in the nearfield, and using Green’s Functions, reconstructs the surface velocity at the plate. The surface velocity from each method is then used in modal analysis to determine the comparability of frequency, damping and mode shapes. Frequency and mode shapes are also compared to an FEA model. Laser Vibrometry is a proven, direct method for determining surface velocity and subsequently calculating modal analysis results. NAH is an effective method in locating noise sources, especially those that are not well separated spatially. Little work has been done in incorporating NAH into modal analysis.
Resumo:
Thermally conductive resins are a class of material that show promise in many different applications. One growing field for their use is in the area of bipolar plate technology for fuel cell applications. In this work, a LCP was mixed with different types of carbon fillers to determine the effects of the individual carbon fillers on the thermal conductivity of the composite resin. In addition, mathematical modeling was performed on the thermal conductivity data with the goal of developing predictive models for the thermal conductivity of highly filled composite resins.
Resumo:
The use of conventional orifice-plate meter is typically restricted to measurements of steady flows. This study proposes a new and effective computational-experimental approach for measuring the time-varying (but steady-in-the-mean) nature of turbulent pulsatile gas flows. Low Mach number (effectively constant density) steady-in-the-mean gas flows with large amplitude fluctuations (whose highest significant frequency is characterized by the value fF) are termed pulsatile if the fluctuations have a direct correlation with the time-varying signature of the imposed dynamic pressure difference and, furthermore, they have fluctuation amplitudes that are significantly larger than those associated with turbulence or random acoustic wave signatures. The experimental aspect of the proposed calibration approach is based on use of Coriolis-meters (whose oscillating arm frequency fcoriolis >> fF) which are capable of effectively measuring the mean flow rate of the pulsatile flows. Together with the experimental measurements of the mean mass flow rate of these pulsatile flows, the computational approach presented here is shown to be effective in converting the dynamic pressure difference signal into the desired dynamic flow rate signal. The proposed approach is reliable because the time-varying flow rate predictions obtained for two different orifice-plate meters exhibit the approximately same qualitative, dominant features of the pulsatile flow.
Resumo:
Integrin alpha10beta1 is a collagen-binding integrin expressed on chondrocytes. In order to unravel the role of the alpha10 integrin during development, we generated mice carrying a constitutive deletion of the alpha10 integrin gene. The mutant mice had a normal lifespan and were fertile but developed a growth retardation of the long bones. Analysis of the skeleton revealed defects in the growth plate after birth characterized by a disturbed columnar arrangement of chondrocytes, abnormal chondrocyte shape and reduced chondrocyte proliferation. Electron microscopy of growth plates from newborn mice revealed an increased number of apoptotic chondrocytes and reduced density of the collagen fibrillar network compared to these structures in control mice. These results demonstrate that integrin alpha10beta1 plays a specific role in growth plate morphogenesis and function.
Resumo:
A tribute to the monumental influence of John Calvin in the 500 years since his birth. / What legacies, still enduring today, have John Calvin and Calvinism given to the church and society in Europe and North America? An international group of scholars tackles that question in this volume honoring Calvin's 500th birthday. These chapters together provide a comprehensive and accessible introduction to Calvin's life and thought, the history of the Reformation in Switzerland and worldwide, and his continuing relevance for ecclesial, social, and political questions today. / Contributors: Philip Benedict, James D. Bratt, Emidio Campi, Wulfert de Greef, Christopher Elwood, Eva-Maria Faber, Eric Fuchs, Ulrich H. J. Krtner, Christian Link, Christian Moser, Andrew Pettegree, Christoph Strohm, Mario Turchetti./ The essays in this book fit beautifully together to provide a solid, complete work that gives precise insight into the many different facets of Calvin and Calvinism. The high-level research found here clearly shows the great impact that Calvin has had on both church and society. It is a great pleasure to see Calvin here anew. Eberhard Busch / University of Gttingen / That John Calvin made a deep and lasting impact on many aspects of history is common knowledge but the character of the man and the nature of his influence are perhaps as controversial as any that can be named. It is thus a challenge to examine even a fraction of the many ways that Calvins life and thought have contributed to the shaping of later ages in both church and society. This volume offers essays on key points from an appropriately international group of authors appreciative but critical, drawing on a rich range of recent scholarship, presented in a pleasing and accessible form. It is a fine place for the new reader of Calvin to get a glimpse of his impact, while offering a fresh summary of some significant issues for more advanced students of the Reformer. Elsie Anne McKee / Princeton Theological Seminary / Hirzel and Sallmann have succeeded in gathering essays by an illustrious circle of experts both historians and theologians on important areas of Calvins thought and impact. Ranging from an insignificant city at the edge of the Swiss Confederation in the 1530s to the Accra Confession of 2004, these essays will serve to correct popular misconceptions. A fine introduction for a broader readership that wants more than mere armchair theology. Peter Opitz / University of Zurich
Resumo:
Plates used for fracture fixation produce vascular injury to the underlying cortical bone. During the recovery of the blood supply, temporary osteoporosis is observed as a result of Haversian remodeling of the necrotic bone. This process temporarily reduces the strength of the bone. We tackled the postulate that quantitative differences exist between animal species, and in different bones within the same species, due to variations in the relative importance of the endosteal and periosteal blood supplies. Using implants scaled to the size of the bone, we found comparable cortical vascular damage in the sheep and in the dog, and in the tibia and femur of each animal. We observed a significant reduction in cortical vascular damage using plates that had a smaller contact area with the underlying bone. No significant difference in cortical vascular damage was noted in animals of different ages.