939 resultados para Carotid Atherosclerosis
Resumo:
PURPOSE: To report the authors' initial experience with carotid artery stent-grafts in a comparatively large patient series for the treatment of acute bleeding and impending rupture or the prevention of distal embolization. MATERIALS AND METHODS: This retrospective study was approved by the institutional review boards and performed according to HIPPA standards. Twenty-five patients were treated with 27 carotid artery stent-grafts (Gore Viabahn, n = 10; Bard Fluency, n = 9; polytetrafluoroethylene-covered Palmaz, n = 5; and Wallgraft, n = 3). Thirteen stent-grafts were placed in patients with carotid blow-out syndrome (including three patients with carotid-airway fistula), 12 in patients with either pseudoaneurysm (n = 9) or true aneurysm (n = 3), and two in patients with intractable high-grade bare stent restenosis. RESULTS: The technical success rate was 100% (27 of 27 cases). No acute procedural transient ischemic attacks or strokes occurred. Procedural dissections occurred in two of the 27 cases (7.4%). Short-term complications occurred in three of the 27 cases (11%) (repeat hemorrhage, n = 2; common carotid artery occlusion, n = 1). The overall patient mortality rate was 36% (nine of 25 patients, all with carotid blow-out syndrome). Six-month follow-up in 15 of the 16 living patients demonstrated widely patent stent-grafts. Two patients with pseudoaneurysm also demonstrated patent stents at 18- and 33-month follow-up. CONCLUSIONS: Stent-grafts may be useful in the treatment of carotid artery bleeding syndrome, aneurysm, and stenosis, with a high procedural success rate in selected cases. The results of mid-term follow-up are encouraging, but results of long-term follow-up must be evaluated in future studies.
Resumo:
OBJECTIVES: To determine the accuracy of automated vessel-segmentation software for vessel-diameter measurements based on three-dimensional contrast-enhanced magnetic resonance angiography (3D-MRA). METHOD: In 10 patients with high-grade carotid stenosis, automated measurements of both carotid arteries were obtained with 3D-MRA by two independent investigators and compared with manual measurements obtained by digital subtraction angiography (DSA) and 2D maximum-intensity projection (2D-MIP) based on MRA and duplex ultrasonography (US). In 42 patients undergoing carotid endarterectomy (CEA), intraoperative measurements (IOP) were compared with postoperative 3D-MRA and US. RESULTS: Mean interoperator variability was 8% for measurements by DSA and 11% by 2D-MIP, but there was no interoperator variability with the automated 3D-MRA analysis. Good correlations were found between DSA (standard of reference), manual 2D-MIP (rP=0.6) and automated 3D-MRA (rP=0.8). Excellent correlations were found between IOP, 3D-MRA (rP=0.93) and US (rP=0.83). CONCLUSION: Automated 3D-MRA-based vessel segmentation and quantification result in accurate measurements of extracerebral-vessel dimensions.
Resumo:
This article provides an overview on the actual state of the interventional neuroradiological management of carotid cavernous fistulas depending on their anatomy and pathophysiology. The results are based on our experience gained during the treatment of patients with complex CCF during the last 15 years. Indications, procedures, and results of transarterial, transvenous and combined arteriovenous approaches for balloon occlusion, embolization, coiling and stenting of these lesions are discussed. Progress in this field is constant so that new technical advances are expected to improve the safety and to expand the indications for these procedures in the future.
Resumo:
PURPOSE: To assess the effect of stent type on hypotension and bradycardia after carotid artery stent placement. MATERIALS AND METHODS: A retrospective analysis on a prospectively maintained database was conducted in 256 patients (126 men; mean age, 71.8 years +/- 8.6; 194 de novo lesions) undergoing carotid artery stent placement between January 1996 and January 2007 by using self-expanding stents. Braided Elgiloy stents (Wallstents) were used in 44 of the 256 patients (17.2%) and slotted-tube nitinol stents were deployed in 212 (82.8%). Bivariate and multivariable logistic regression models were used to determine the influence of stent design on procedural and 24-hour hypotension and bradycardia. RESULTS: Procedural hemodynamic depression (HD) was encountered in 73 of the 256 patients (28.5%) due to hypotension in 24 (9.4%), bradycardia in 12 (4.7%), or both in 37 (14.5%) patients. Rates of procedural hypotension were 11.3% with nitinol stents and 0% with braided Elgiloy stents (P = .0188). Persistent postprocedural HD occurred in 91 of the 256 patients (35.5%) due to hypotension in 40 patients (15.6%), bradycardia in 23 (9.0%), or both in 28 (10.9%). Within a multivariable analysis adjusted for clinically relevant factors affecting rates of HD, the use of braided Elgiloy stents was associated with a decreased rate of procedural hypotension (odds ratio: 0.165; 95% confidence interval: 0.038, 0.721; P = .017). Procedural hypotension and bradycardia were not correlated to incidence of major adverse events but were associated with an increased duration of hospital stay (P = .0059 and P = .0335, respectively). CONCLUSIONS: Nitinol stents are associated with a higher risk of hypotension as compared to braided Elgiloy stents during carotid artery stent placement.
Resumo:
OBJECTIVE: To prospectively evaluate outcomes of high-risk patients undergoing bilateral carotid artery stenting (CAS). METHODS: A total of 747 patients at increased risk for carotid endarterectomy (CEA) were enrolled in a prospective registry at 47 US sites of the Boston Scientific EPI: A Carotid Stenting Trial for Risk Surgical Patients (BEACH) trial. Among them, 78 (10.4%) patients underwent contralateral CAS > 30 days after the primary CAS procedure. Patients were followed at 1, 6, and 12 months, and annually thereafter for 3 years. The primary endpoint was the cumulative incidence of non Q-wave myocardial infarction within 24 hours, periprocedural (
Resumo:
OBJECTIVES: We investigated whether qualitative or quantitative alterations of the endothelial progenitor cell (EPC) pool predict age-related structural vessel wall changes. BACKGROUND: We have previously shown that age-related endothelial dysfunction is accompanied by qualitative rather than quantitative changes of EPCs. Animal studies suggest that impaired EPC functions lead to accelerated arterial intimal thickening. METHODS: Intima-media thickness (IMT) was measured in the common carotid artery in our previously published groups of younger (25 +/- 1 years, n = 20) and older (61 +/- 2 years, n = 20) healthy non-smoking volunteers without arterial hypertension, hypercholesterolemia, and diabetes mellitus. Endothelial progenitor cells (EPCs, KDR(+)/CD34(+) and KDR(+)/CD133(+)) were counted in peripheral blood using flow cytometry. In ex vivo expanded EPCs, the function was determined as chemotaxis to VEGF, proliferation, and survival. RESULTS: We observed thicker IMT in older as compared to younger subjects (0.68 +/- 0.03 mm Vs. 0.48 +/- 0.02 mm, P < 0.001). Importantly, there were significant inverse univariate correlations between IMT, EPC chemotaxis, and survival (r = -0.466 P < 0.05; r = -0.463, P < 0.01). No correlation was observed with numbers of circulating EPCs. Multivariate regression analysis revealed that age, mean arterial pressure and migration of EPCs were independent predictors of IMT (R (2 )= 0.58). CONCLUSION: Impaired EPC function may lead to accelerated vascular remodeling due to chronic impairment of endothelial maintenance.
Resumo:
PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.
Resumo:
BACKGROUND: Little is known on the performance of newly initiated carotid artery stenting (CAS) programs. The safety of the procedure is being questioned following the publication of the EVA-3S trial, a study criticized for the limited interventional experience required to enroll patients. METHODS: Within a newly started academic CAS program, patient data and outcomes were collected prospectively. The outcomes of the first 100 consecutive patients treated are reported. A CAS-fellowship-trained interventionalist was involved in all procedures. All patients underwent clinical assessment by a neurologist before and after the procedure, and serial ECG and cardiac enzymes were routinely obtained. Primary outcome measures included 30-day major adverse events (MAE), defined as death, stroke, or myocardial infarction, while on follow-up deaths and ipsilateral strokes were added. RESULTS: Between July 2003 and November 2006, 92 patients had a single internal carotid artery treated, while 7 underwent staged bilateral CAS. In one patient, the procedure was aborted prior to lesion treatment. The 30-day MAE rate per procedure was 1.9% (one major and one minor stroke). By a mean follow-up of 16 months (range 2-42 months), one patient had died of refractory heart failure, while one patient had a minor ipsilateral stroke and three had minor contralateral strokes, corresponding to total MAE per patient of 4%. The rate of any stroke or death was 7%. The rate of restenosis >or=50% per lesion by ultrasound was 3.8%. CONCLUSION: This single center experience suggests that it is safe to start a CAS program following dedicated fellowship.
Resumo:
The authors describe the use of the Cardica C-Port xA Distal Anastomosis System to perform an automated, high-flow extracranial-intracranial bypass. The C-Port system has been developed and tested in coronary artery bypass surgery for rapid distal coronary artery anastomoses. Air-powered, it performs an automated end-to-side anastomosis within seconds by nearly simultaneously making an arteriotomy and inserting 13 microclips into the graft and recipient vessel. Intracranial use of the device was first simulated in a cadaver prepared for microsurgical anatomical dissection. The authors used this system in a 43-year-old man who sustained a subarachnoid hemorrhage after being assaulted and was found to have a traumatic pseudoaneurysm of the proximal intracranial internal carotid artery. The aneurysm appeared to be enlarging on serial imaging studies and it was anticipated that a bypass would probably be needed to treat the lesion. An end-to-side bypass was performed with the C-Port system using a saphenous vein conduit extending from the common carotid artery to the middle cerebral artery. The bypass was demonstrated to be patent on intraoperative and postoperative arteriography. The patient had a temporary hyperperfusion syndrome and subsequently made a good neurological recovery. The C-Port system facilitates the performance of a high-flow extracranial-intracranial bypass with short periods of temporary arterial occlusion. Because of the size and configuration of the device, its use is not feasible in all anatomical situations that require a high-flow bypass; however it is a useful addition to the armamentarium of the neurovascular surgeon.
Resumo:
TNFalpha (TNF) critically regulates inflammation-driven atherosclerosis. Because the transmembrane (tmTNF) and soluble (sTNF) forms of TNF possess distinct immuno-modulatory properties, we hypothesized that they might differentially regulate atherosclerosis progression. Three groups of male ApoE(-/-) mice were studied: one expressing wild-type TNF (WT-TNF); one expressing exclusively a mutated non-cleavable form of TNF (KI-TNF); and one deficient in TNF (KO-TNF). Mice aged 5 weeks were fed the high-fat diet for 5 (T5) and 15 weeks (T15) or a standard chow diet for 15 weeks. At T5, in mice fed the high-fat diet, no significant differences in lesion area were observed among the three groups, either in valves or in aortas. At T15, lesion areas in valves were significantly lower in KO-TNF mice compared with those in WT-TNF mice, whereas in KI-TNF mice, they were intermediate between KO- and WT-TNF mice but not significantly different from these two groups. In aortas, lesions in KI-TNF were comparable to those of KO-TNF, both being significantly lower than those in WT-TNF. Theses differences were not linked to circulating lipids, or to macrophage, actin, and collagen contents of lesions. At T15, in mice fed the chow diet, lesion areas in valves and the aortic arch were not significantly different between the three groups. Levels of IL-6, IFNgamma, IL-10, and Foxp3 mRNAs in spleens and production of IL-6, IL-10, MCP-1, RANTES, and TNFR-2 by peritoneal macrophages at T15 of the high-fat diet showed a decrease in pro-inflammatory status, more marked in KO-TNF than in KI-TNF mice. Apoptosis was reduced only in KO-TNF mice. In conclusion, these data show that TNF effects on atherosclerosis development are detectable at stages succeeding fatty streaks and that wild-type TNF is superior to tmTNF alone in promoting atherosclerosis. TNF-dependent progression of atherosclerosis is probably linked to the differential production of pro-inflammatory mediators whether tmTNF is preponderant or essentially cleaved. Copyright (c) 2008 Pathological Society of Great Britain and Ireland. Published by John Wiley ; Sons, Ltd.
Resumo:
BACKGROUND AND PURPOSE: We set out to investigate the predictors and time course for recanalization of spontaneous dissection of the cervical internal carotid artery (SICAD). METHODS: We prospectively included 249 consecutive patients (mean age, 45+/-11 years) with 268 SICAD. Ultrasound examinations were performed at presentation, during the first month, and then at 3, 6, and 12 months, and clinical follow-ups after 3, 6, and 12 months. RESULTS: Of 268 SICADs, 20 (7.5%) presented with