467 resultados para COAXIAL CABLES
Resumo:
In the last decades it has been observed a substantial developing of the electrical energy demand in the societies all over the World. In consequence the electrical energy distribution companies are increasing the quantity of electrical energy through the electrical energy conductor cables, which had grown the sag in the towers of energy transmission. Furthermore, the construction of more transmission towers brings a lot of troubles due environmental protection laws. In this way, looking forward to increase the quantity of electrical energy transmitted through electrical cables conductors, reduce the need of constructing new transmission towers and the sag in them, we suggest in this work the replace of the traditional core of the conductors cables commonly used, made of steel, by a core made by a composite material, which one is made by carbon fibers pultruded with polymeric resins as matrix. In a order to evaluate if the resins more commonly used in structural composites can be applied as matrix to make possible to use the composite material as a core, we made carbon fibers systems pultruded with epoxy, phenolic and polyester resins as matrix and a mechanic and physic-chemistry characterization was done on the systems by Tensile and Poisson tests, differential sprobe calorimetry (DSC), thermogravimetric analysis (TGA) and Fourier transformed infrared spectroscopy (FTIR), following their correspondents standards
Resumo:
Therebar of aluminum 1350 AA produced by CBA are used inthe manufacture of wires and cables for electric power transmission, which marketshows increasingly favorableto aluminum due to itslow densityand high electrical conductivity, but to ensure that this materialmeets all specifications of projectsfor electricity transmission, it must have homogeneity in the chemicaland mechanicalproperties.One of the points of improvement in the process of rod production isreducing the high variation of the limitof tensile strengthalong the coils, therefore, this work seeks a better understanding of the factors that significantly influence the mechanical properties of rebar, specifically assessing the influence oftemperatureat the output of the coils, which can cause a recovery effect on the material andif thereare relevantdifferences between the two modes of rebar production: auto and manual.Samples of six coils have been specifically produced forthis study, which weresubsequently subjected to different annealing temperatures for one hour and ten minutes, similar to what occurs in the output of the coil from the machine. The tensile tests showed that aluminum 1350 AA is significantly influenced by temperature, whose behavior was very similar to that presented in the literature. It was found that the phenomenon of recovery occurred more significantly at high temperatures. Through the optical electron microscope Zeiss, 18 surface maps were made with 100x magnification for each sample in different conditions and the images were analyzed using entropy and fractal dimension, aiming to relate the condition of surface hardening on mechanical property of the samples in that condition. The results showed that these methods can be applied, provided they do not have any kind of imperfection on the surface, once they can influence the results. The study concluded that a more efficient cooling is required in ... (Complete abstract click electronic access below)
Resumo:
The most usual method to fix supports that hold the vast majority of electrical cables on an aircraft is accomplished by using, for this purpose, rivets. However, this procedure may some cause some inconveniences such as the need of effecting holes in the structure that is intended to fix these supports, thus decreasing resistance of the structure. In order to have an alternative to seek an increase in the performance of structured materials, the aircraft industry, like other industries, have been studying the use of collage as a method of replacing this usual forms. Against this backdrop, this paper aims to assess the strength and durability of a joint bonded using the adhesive EA9394, manufactured by company Henkel Corporation, and perform a careful survey of the mechanical performance of riveted structures, taking into account different types of conditioning environment and thus create a database that can be used by the aerospace industry
Resumo:
The present work aims to prepare a study of selectivity and coordination in an isolated electrical system with the aid of computer software PTW (Power Tools for Windows). Based on appropriate protection standards, on equipment data and the survey of the curves of “time versus current” (Time Current Curve – TCC), may be defined protection settings to leave the system selective, coordinated and properly protected. Definitions of adjustments are made taking into account the data of, so called, thermal curves of the equipment, which take into account the rated current and the supportability of short-circuit current of the equipment and cables involved in the installation in question. For that we use the tools provided by the PTW in which an industrial electrical circuit is simulated, presenting and discussing the results. With that validates the software PTW, taking it as a great tool helper implementation the coordination and selectivity study
Resumo:
Distribution networks are formed by long lines that carry electricity substations to homes and industries. These lines have associated impedance and depending on operating conditions of the network these impedances may vary. This paper provides a detailed analysis of the effects observed in studies of voltage drop, short circuit and electrical losses, when considered the drivers sequence impedances used in primary distribution network at different temperatures. Therefore, it is initially presented a calculation methodology and details the factors that influence the final values. The methodology presented tackles in a practical way the main factors that directly or indirectly influence the values of the impedances as an emblematic example and will be properly dealt with throughout the paper is the effect of temperature on the values of the sequence impedances. More specifically is dealt with the case of XLPE cables protected, by having a higher maximum operating temperature than the operating temperature of the network. The effects observed in the power flow generated when considering the impedance values at both temperatures were analyzed. The impedance drivers tend to increase with increasing temperature. Thus the impedance of the conductor XLPE protected will tend to be greater for the maximum operating temperature for which the operating temperature of the network, resulting in greater voltage drop and higher electrical losses
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The trapezius muscle (superior, middle and inferior portions) was analyzed in 20 volunteers. The electromyographic tests were carried out using a four-channel TECA TE 2-7 electromyograph with surface- and single coaxial needle electrodes. In abduction, adduction and flexion-extension, the 3 portions show increasing and decreasing activity, respectively, from the beginning until the end of these movements. In hyperextension, the 3 portions show increasing activity from the beginning until the end of the movement, with greater participation of the middle portion. Significant differences were not observed in the electromyographic profile of the trapezius, using surface and needle electrodes.
Resumo:
The objective of this study is to analyze the simultaneity of the actions of the three portions of the trapezius (superior portion = TS; middle portion = TM and inferior portion = TI) in elevation, lowering, retraction and protraction of the shoulders. The electromyographic tests were carried out in 20 volunteers using a 4-channel TECA TE 2-7 electromyograph and surface and single coaxial needle electrodes. The electromyographs, obtained with the two types of electrodes, show that in elevation and lowering of the shoulders, TS and TM present increasing and decreasing activity, respectively, from the beginning until the end of these movements. In retraction of the shoulders, TM and TI present increasing activity from the beginning to the end of the movement. In protraction, TS, TM and TI do not show any activity.
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
The rapid industrial development and disorganized population growth in huge cities bring about various urban problems due to intense use of physical space on and below the surface. Subsurface problems in metropolitan areas are caused by subway line construction, which often follows the routes of utility networks, such as electric and telephone cables, water and gas pipes, storm sewers, etc. Usually, the main problems are related to damage or destruction of preexisting utilities, often putting human lives at risk. With the purpose of minimizing risks. GPR-profiling with 200 MHz antennae was done at two sites, both located in downtown Sao Paulo, Brazil. The objectives of this work were to map utilities or existing infrastructure in the subsurface in order to orient the construction of the Line 4 (yellow) subway tunnel in Sao Paulo. GPR profiles can detect water pipes, utility networks in the subsurface, and concrete foundation columns or pilings in subsoil up to 2 m depth. In addition. the GPR profiles also provided details of the target shapes in the subsurface. GPR interpretations combined with lithological information from boreholes and trenches opened in the study areas were extremely important in mapping of the correct spatial distribution of buried utilities at these two sites in Sao Paulo. This information improves and updates maps of utility placement, serves as a basis for planning of the geotechnical excavation of the Line 4 (yellow) subway tunnel in Sao Paulo, helps minimize problems related to destruction of preexisting utilities in the subsoil, and avoids risk of dangerous accidents. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The need for increasing the loading capacity of transmission lines in a traditional way, by replacing or reinforcement of the structures and foundations on routes crossing areas considered of permanent environmental preservation, may require additional works that alter the environment. The present rigorous environmental legislation turns these changes and substitution unfeasible. One way to increase the capacity of these lines is the use of new conductor technology. The aim of this paper is to discuss the needs for upgrading a transmission line and minimize or eliminate the damage to the environment by using special conductors. Because the aluminum conductor composite reinforced technology is relatively new and considering the lack of information related to its effective performance in practical system, there is a need to verify the behavior of these conductors through monitoring procedures.