907 resultados para CLINICAL TRIALS


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Globalisation in coronary stent research calls for harmonization of clinical endpoint definitions and event adjudication. Little has been published about the various processes used for event adjudication or their impact on outcome reporting.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Oncological liver surgery and interventions aim for removal of tumor tissue while preserving a sufficient amount of functional tissue to ensure organ regeneration. This requires detailed understanding of the patient-specific internal organ anatomy (blood vessel system, bile ducts, tumor location). The introduction of computer support in the surgical process enhances anatomical orientation through patient-specific 3D visualization and enables precise reproduction of planned surgical strategies though stereotactic navigation technology. This article provides clinical background information on indications and techniques for the treatment of liver tumors, reviews the technological contributions addressing the problem of organ motion during navigated surgery on a deforming organ, and finally presents an overview of the clinical experience in computer-assisted liver surgery and interventions. The review concludes that several clinically applicable solutions for computer aided liver surgery are available and small-scale clinical trials have been performed. Further developments will be required more accurate and faster handling of organ deformation and large clinical studies will be required for demonstrating the benefits of computer aided liver surgery.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: We sought to determine whether a high-risk group could be defined among patients with operable breast cancer in whom a search of occult central nervous system (CNS) metastases was justified. PATIENTS AND METHODS: We evaluated data from 9524 women with early breast cancer (42% node-negative) who were randomized in International Breast Cancer Study Group clinical trials between 1978 and 1999, and treated without anthracyclines, taxanes, or trastuzumab. We identified patients whose site of first event was CNS and those who had a CNS event at any time. RESULTS: Median follow-up was 13 years. The 10-year incidence (10-yr) of CNS relapse was 5.2% (1.3% as first recurrence). Factors predictive of CNS as first recurrence included: node-positive disease (10-yr = 2.2% for > 3 N+), estrogen receptor-negative (2.3%), tumor size > 2 cm (1.7%), tumor grade 3 (2.0%), < 35 years old (2.2%), HER2-positive (2.7%), and estrogen receptor-negative and node-positive (2.6%). The risk of subsequent CNS recurrence was elevated in patients experiencing lung metastases (10-yr = 16.4%). CONCLUSION: Based on this large cohort we were able to define risk factors for CNS metastases, but could not define a group at sufficient risk to justify routine screening for occult CNS metastases.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Others have reported ocular toxicity after adjuvant chemoendocrine therapy, but this study looked at ocular toxicity in similarly treated patients from large randomized clinical trials. METHODS: Information was retrieved on incidence and timing of ocular toxicity from the International Breast Cancer Study Group (IBCSG) database of 4948 eligible patients randomized to receive tamoxifen or toremifene alone or in combination with chemotherapy (either concurrently or sequentially). Case reports of patients with ocular toxicity were evaluated to determine whether ocular toxicity occurred during chemotherapy and/or hormonal therapy. Additional information was obtained from participating institutions for patients in whom ocular toxicity occurred after chemotherapy but during administration of tamoxifen or toremifene. RESULTS: Ocular toxicity was reported in 538 of 4948 (10.9%) patients during adjuvant treatment, mainly during chemotherapy. Forty-five of 4948 (0.9%) patients had ocular toxicity during hormone therapy alone, but only 30 (0.6%) patients had ocular toxicity reported either without receiving any chemotherapy or beyond 3 months after completing chemotherapy and, thus, possibly related to tamoxifen or toremifene. In 3 cases, retinal alterations, without typical aspects of tamoxifen toxicity, were reported; 4 patients had cataract (2 bilateral), 12 impaired visual acuity, 10 ocular irritation, 1 optical neuritis, and the rest had other symptoms. CONCLUSION: Ocular toxicity during adjuvant therapy is a common side effect mainly represented by irritative symptoms due to chemotherapy. By contrast, ocular toxicity during hormonal therapy is rare and does not appear to justify a regular program of ocular examination. However, patients should be informed of this rare side effect so that they may seek prompt ophthalmic evaluation for ocular complaints.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Short-acting agents for neuromuscular block (NMB) require frequent dosing adjustments for individual patient's needs. In this study, we verified a new closed-loop controller for mivacurium dosing in clinical trials. METHODS: Fifteen patients were studied. T1% measured with electromyography was used as input signal for the model-based controller. After induction of propofol/opiate anaesthesia, stabilization of baseline electromyography signal was awaited and a bolus of 0.3 mg kg-1 mivacurium was then administered to facilitate endotracheal intubation. Closed-loop infusion was started thereafter, targeting a neuromuscular block of 90%. Setpoint deviation, the number of manual interventions and surgeon's complaints were recorded. Drug use and its variability between and within patients were evaluated. RESULTS: Median time of closed-loop control for the 11 patients included in the data processing was 135 [89-336] min (median [range]). Four patients had to be excluded because of sensor problems. Mean absolute deviation from setpoint was 1.8 +/- 0.9 T1%. Neither manual interventions nor complaints from the surgeons were recorded. Mean necessary mivacurium infusion rate was 7.0 +/- 2.2 microg kg-1 min-1. Intrapatient variability of mean infusion rates over 30-min interval showed high differences up to a factor of 1.8 between highest and lowest requirement in the same patient. CONCLUSIONS: Neuromuscular block can precisely be controlled with mivacurium using our model-based controller. The amount of mivacurium needed to maintain T1% at defined constant levels differed largely between and within patients. Closed-loop control seems therefore advantageous to automatically maintain neuromuscular block at constant levels.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

STUDY DESIGN: Systematic literature review. OBJECTIVE: To evaluate the safety and efficacy of vertebroplasty and kyphoplasty using the data presented in published clinical studies, with respect to patient pain relief, restoration of mobility and vertebral body height, complication rate, and incidence of new adjacent vertebral fractures. SUMMARY OF BACKGROUND DATA: Vertebroplasty and kyphoplasty have been gaining popularity for treating vertebral fractures. Current reviews provide an overview of the procedures but are not comprehensive and tend to rely heavily on personal experience. This article aimed to compile all available data and evaluate the clinical outcome of the 2 procedures. METHODS: This is a systematic review of all the available data presented in peer-reviewed published clinical trials. The methodological quality of included studies was evaluated, and data were collected targeting specific standard measurements. Where possible, a quantitative aggregation of the data was performed. RESULTS: A large proportion of subjects had some pain relief, including 87% with vertebroplasty and 92% with kyphoplasty. Vertebral height restoration was possible using kyphoplasty (average 6.6 degrees ) and for a subset of patients using vertebroplasty (average 6.6 degrees ). Cement leaks occurred for 41% and 9% of treated vertebrae for vertebroplasty and kyphoplasty, respectively. New fractures of adjacent vertebrae occurred for both procedures at rates that are higher than the general osteoporotic population but approximately equivalent to the general osteoporotic population that had a previous vertebral fracture. CONCLUSIONS: The problem with stating definitely that vertebroplasty and kyphoplasty are safe and effective procedures is the lack of comparative, blinded, randomized clinical trials. Standardized evaluative methods should be adopted.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: The aim of this paper was to review the clinical literature on the Resonance frequency analysis (RFA) and Periotest techniques in order to assess the validity and prognostic value of each technique to detect implants at risk for failure. Material and methods: A search was made using the PubMed database to find clinical studies using the RFA and/or Periotest techniques. Results: A limited number of clinical reports were found. No randomized-controlled clinical trials or prospective cohort studies could be found for validity testing of the techniques. Consequently, only a narrative review was prepared to cover general aspects of the techniques, factors influencing measurements and the clinical relevance of the techniques. Conclusions: Factors such as bone density, upper or lower jaw, abutment length and supracrestal implant length seem to influence both RFA and Periotest measurements. Data suggest that high RFA and low Periotest values indicate successfully integrated implants and that low/decreasing RFA and high/increasing Periotest values may be signs of ongoing disintegration and/or marginal bone loss. However, single readings using any of the techniques are of limited clinical value. The prognostic value of the RFA and Periotest techniques in predicting loss of implant stability has yet to be established in prospective clinical studies. To cite this article: Aparicio C, Lang N P, Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin. Oral Imp. Res., 17 (Suppl. 2), 2006; 2-7.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Bioequivalence trials are abbreviated clinical trials whereby a generic drug or new formulation is evaluated to determine if it is "equivalent" to a corresponding previously approved brand-name drug or formulation. In this manuscript, we survey the process of testing bioequivalence and advocate the likelihood paradigm for representing the resulting data as evidence. We emphasize the unique conflicts between hypothesis testing and confidence intervals in this area - which we believe are indicative of the existence of the systemic defects in the frequentist approach - that the likelihood paradigm avoids. We suggest the direct use of profile likelihoods for evaluating bioequivalence and examine the main properties of profile likelihoods and estimated likelihoods under simulation. This simulation study shows that profile likelihoods are a reasonable alternative to the (unknown) true likelihood for a range of parameters commensurate with bioequivalence research. Our study also shows that the standard methods in the current practice of bioequivalence trials offers only weak evidence from the evidential point of view.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Chinese herbal medicine (CHM) is increasingly used in the West, but the evidence on its effectiveness is a matter of debate. We compared the characteristics, study quality and results of clinical trials of CHM and conventional medicine. METHODS: Comparative study of placebo-controlled trials of CHM and conventional medicine. Eleven bibliographic databases and searches by hand of 48 Chinese-language journals. Conventional medicine trials matched for condition and type of outcome were randomly selected from the Cochrane Controlled Trials Register (issue 1, 2003). Trials described as double-blind, with adequate generation of allocation sequence and adequate concealment of allocation, were assumed to be of high quality. Data were analysed using funnel plots and multivariable meta-regression models. RESULTS: 136 CHM trials (119 published in Chinese, 17 published in English) and 136 matched conventional medicine trials (125 published in English) were analysed. The quality of Chinese-language CHM trials tended to be lower than that of English-language CHM trials and conventional medicine trials. Three (2%) CHM trials and 10 (7%) conventional medicine trials were of high quality. In all groups, smaller trials showed more beneficial treatment effects than larger trials. CHM trials published in Chinese showed considerably larger effects than CHM trials published in English (adjusted ratio of ORs 0.29, 95% confidence intervals 0.17-0.52). CONCLUSIONS: Biases are present both in placebo-controlled trials of CHM and conventional medicine, but may be most pronounced in CHM trials published in Chinese-language journals. Only few CHM trials of adequate methodology exist and the effectiveness of CHM therefore remains poorly documented.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

GOALS OF WORK: The aim of this study was to evaluate pain intensity and the application of the WHO guidelines for cancer pain treatment in patients with prostate cancer treated at Swiss cancer centers. MATERIALS AND METHODS: We analyzed a series of five multicenter phase II clinical trials which examined the palliative effect of different chemotherapies in patients with advanced hormone-refractory prostate carcinoma. Of 170 patients, 1,018 visits were evaluable for our purpose, including ratings of pain intensity by patients and prescribed analgesics. MAIN RESULTS: No or mild pain was indicated by patients in 36 to 55% of the visits, more than mild pain in 30 to 46%. In 21% of the visits, the WHO pain treatment criteria (treatment according to one of the three steps; oral, rectal or transdermal application of the main dose; administration on a regular schedule) were fulfilled, and the Cleeland index was positive according to all recommendations. In 6% of the visits, neither the WHO criteria were fulfilled nor was the Cleeland index positive. This indicates insufficient pain treatment not following the WHO guidelines and that the prescribed analgesics were not sufficiently potent for the rated pain intensity. CONCLUSIONS: In this selective Swiss sample, the standard of analgesic treatment is high. However, there is still scope for improvement. This cannot solely be solved by improving the knowledge of the physicians. Programs to change the patients' attitude towards cancer pain, training to improve the physicians' communication skills, and institutional changes may be promising strategies.