995 resultados para Buried heat sources
Resumo:
This paper intends to evaluate the capacity of producing concrete with a pre-established performance (in terms of mechanical strength) incorporating recycled concrete aggregates (RCA) from different sources. To this purpose, rejected products from the precasting industry and concrete produced in laboratory were used. The appraisal of the self-replication capacity was made for three strength ranges: 15-25 MPa, 35-45 MPa and 65-75 MPa. The mixes produced tried to replicate the strength of the source concrete (SC) of the RA. Only total, (100%) replacement of coarse natural aggregates (CNA) by coarse recycled concrete aggregates (CRCA) was tested. The results show that, both in mechanical and durability terms, there were no significant differences between aggregates from controlled sources and those from precast rejects for the highest levels of the target strength. Furthermore, the performance losses resulting from the RA's incorporation are substantially reduced when used medium or high strength SC's. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, Perfil Gestão e Sistemas Ambientais
Resumo:
This paper presents a computational tool (PHEx) developed in Excel VBA for solving sizing and rating design problems involving Chevron type plate heat exchangers (PHE) with 1-pass-1-pass configuration. The rating methodology procedure used in the program is outlined, and a case study is presented with the purpose to show how the program can be used to develop sensitivity analysis to several dimensional parameters of PHE and to observe their effect on transferred heat and pressure drop.
Resumo:
The differentiation of non-integer order has its origin in the seventeenth century, but only in the last two decades appeared the first applications in the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated namely the fractional PID and the Smith predictor. Extensive simulations are presented assessing the performance of the proposed fractional-order algorithms.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
Até 2020, a Europa terá de reduzir 20% das suas emissões de gases com efeito de estufa, 20% da produção de energia terá de ser proveniente de fontes renováveis e a eficiência energética deverá aumentar 20%. Estas são as metas apresentadas pela União Europeia, que ficaram conhecidas por 20/20/20 [1]. A Refinaria de Matosinhosé um complexo industrial que opera no sector da refinação e que apresenta preocupações ao nível da eficiência energética e dos aspectos ambientais subjacentes. No âmbito da racionalização energética das refinarias, a Galp Energia tem vindo a implementar um conjunto de medidas, adoptando as melhores tecnologias disponíveis com o objectivo de diminuir os consumos de energia, promover a eficiência energética e reduzir as emissões de dióxido de carbono. Para ir de encontro a estas medidas foi elaborado um estudo comparativo que permitiu à empresa definir as medidas consideradas prioritárias. Uma solução encontrada visa a execução de projectos que não requerem investimento e que têm acções imediatas, tais como o aumento da eficiência energética das fornalhas [1]. Este trabalho realizado na Galp Energia S.A. teve como objectivo principal a optimização energética da Unidade de Desalfatação do Propano da Fábrica de Óleos Base. Esta optimização baseou-se no aproveitamento energético da corrente de fundo da coluna de rectificação T2003C com uma potência calorífica de 2,79 Gcal/h. Após levantamento de todas as variáveis do processo relativas a esta unidade, especialmente a potência calorífica das correntes envolvidas chegou-se á conclusão que a fornalha H2101 poderá ser substituída por dois permutadores, reduzindo desta forma os consumos energéticos. Pois a corrente de fundo da coluna T2003 com uma potência calorífica 2,79 Gcal/h poderá permutar calor com a corrente da mistura asfalto com propano, fazendo com que esta atinja temperatura superior à obtida com a fornalha em funcionamento. A análise económica ao consumo e respectivo custo do fuelóleo na fornalha para o período de um ano foi realizada, sendo o seu custo de combustível de 611.396,00 €. O valor da aquisição dos permutadores é 86.355,97€, sendo rentável a alteração proposta neste projecto.
Resumo:
Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.
Resumo:
The concept of differentiation and integration to non-integer order has its origins in the seventeen century. However, only in the second-half of the twenty century appeared the first applications related to the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated and compared. Simulations are presented assessing the performance of the proposed fractional-order algorithms.
Resumo:
Immune response against hepatitis B vaccine (CLB 3mg) was evaluated in 59 hemodialysis patients and 20 occupational risk personnel. Seroconversion was induced in 52.5% and 70.0% respectively. Twelve months after the first dose, 37.5% of patients and 60.0% of occupational risk personnel had detectable anti-HBs level. Antibody level was expressed in sample ratio units (SRU). Considering only the responders, in the patients group 38.7% had a low anti-HBs response (2.1-9.9 SRU) 32.3% a medium response (10-99.9 SRU) and 29.0% a high response (>100 SRU) while in occupational risk personnel these values were 14.3%, 64.3% and 21.4% respectively. The authors suggest the use of HBV vaccines with more elevated HBsAg concentration or a reinforced immunization schedule to improve the anti-HBs response not only for patients but also for healthy persons.
Resumo:
Pultrusion is an industrial process used to produce glass fibers reinforced polymers profiles. These materials are worldwide used when performing characteristics, such as great electrical and magnetic insulation, high strength to weight ratio, corrosion and weather resistance, long service life and minimal maintenance are required. In this study, we present the results of the modelling and simulation of heat flow through a pultrusion die by means of Finite Element Analysis (FEA). The numerical simulation was calibrated based on temperature profiles computed from thermographic measurements carried out during pultrusion manufacturing process. Obtained results have shown a maximum deviation of 7%, which is considered to be acceptable for this type of analysis, and is below to the 10% value, previously specified as maximum deviation. © 2011, Advanced Engineering Solutions.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Portugal é um país dependente da energia do exterior, devido à elevada percentagem de consumo de energia a partir de fontes primárias, como por exemplo o gasóleo. Para colmatar este cenário, têm vindo a criar-se incentivos para o uso de energias renováveis e para intensificação de medidas de eficiência energética, como os sistemas de cogeração, de forma a tornar os processos industriais nacionais mais autónomos e mais competitivos. O presente trabalho, centra-se na determinação do potencial térmico disponível na central de trigeração da empresa Monteiro, Ribas-Indústria, SA, com a finalidade de identificar a quantidade de energia não utilizada, com vista ao aproveitamento dessa mesma energia nos processos mais problemáticos da empresa. Verificou-se que a água líquida era a fonte de maior energia não aproveitada, representando cerca de 30%, relativamente à energia disponível na água de refrigeração que é de 1890 kW. Assim, perante este facto, fez-se um estudo em dois setores autónomos da empresa, o setor dos revestimentos e o setor dos componentes técnicos da borracha. Pretendeu-se propor medidas para melhorar os seus processos produtivos, aproveitando essa energia. Para o efeito foi projetado um permutador de calor de placas com necessidade energética de 131,4 MWh, no setor dos revestimentos e um permutador compacto no setor de produção de placas de borracha, necessitando de uma energia de 335,2 MWh. Face à energia disponível na central de trigeração, de 161,9 MWh, verifica-se que esta apenas poderá ser aproveitada no setor dos revestimentos. Para tornar este objetivo real, a empresa Monteiro, Ribas- Indústria, SA necessitaria de efetuar um investimento no total de 49.390€. Além disso, foi contabilizado o rendimento das caldeiras da central térmica e da cogeração, ambas pelo método direto, apresentando estas os valores de 72% e 42%, respectivamente.
Resumo:
In this article, we present the first study on probabilistic tsunami hazard assessment for the Northeast (NE) Atlantic region related to earthquake sources. The methodology combines the probabilistic seismic hazard assessment, tsunami numerical modeling, and statistical approaches. We consider three main tsunamigenic areas, namely the Southwest Iberian Margin, the Gloria, and the Caribbean. For each tsunamigenic zone, we derive the annual recurrence rate for each magnitude range, from Mw 8.0 up to Mw 9.0, with a regular interval, using the Bayesian method, which incorporates seismic information from historical and instrumental catalogs. A numerical code, solving the shallow water equations, is employed to simulate the tsunami propagation and compute near shore wave heights. The probability of exceeding a specific tsunami hazard level during a given time period is calculated using the Poisson distribution. The results are presented in terms of the probability of exceedance of a given tsunami amplitude for 100- and 500-year return periods. The hazard level varies along the NE Atlantic coast, being maximum along the northern segment of the Morocco Atlantic coast, the southern Portuguese coast, and the Spanish coast of the Gulf of Cadiz. We find that the probability that a maximum wave height exceeds 1 m somewhere in the NE Atlantic region reaches 60 and 100 % for 100- and 500-year return periods, respectively. These probability values decrease, respectively, to about 15 and 50 % when considering the exceedance threshold of 5 m for the same return periods of 100 and 500 years.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
Cryo-microtome sections of larvae of Strongyloides stercoralis and S. ratti respectively obtained from human and rat feces cultures, were used as antigens. Fluoresceinate conjugates against human IgG were employed at the ideal titer of 10 for S. stercoralis and 100 for S. ratti. The sensitivity of the indirect immunofluorescence reaction (IIF) was 94.4% and 92.5% and the specificity 94.2% and 97.1% for the two specific larval antigens, respectively. Sera from 123 persons (54 from carriers of S. stercoralis infections and 69 from controls) were submitted to the reaction. The titers of different sera varied from 20 to 2560. There was a significant linear correlation (r = 0.85 p £ 0.001) between the antibodies from the two species of larval antigens. We conclude that both antigens may be used in the IIF reaction for the diagnosis of human strongyloidiasis. Due to the feasibility of safe and low-cost mass production of S. ratti larvae in the laboratory with a considerable economy of conjugate, their utilization in the serum diagnosis of human strongyloidiasis is recommended