945 resultados para Allergic asthma


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: There is promising but conflicting evidence to recommend the addition of probiotics to foods for prevention and treatment of allergy. Based on previous studies with fermented milk containing Lactobacillus paracasei NCC2461, we aimed to compare the effect of a powder form of the latter probiotic with the effect of a blend of Lactobacillus acidophilus ATCC SD5221 and Bifidobacterium lactis ATCC SD5219 in patients with allergic rhinitis. METHODS: A double-blind, randomized, cross-over study, involving 31 adults with allergic rhinitis to grass pollen, was performed outside the grass pollen season (registration number: NCT01233154). Subjects received each product for 4-weeks in two phases separated by a wash-out period of 6 to 8 weeks. A nasal provocation test was performed before and after each 4-week product intake period, and outcome parameters (objective and subjective clinical symptoms; immune parameters) were measured during and/or 24 hours after the test. RESULTS: Out of the 31 subject enrolled, 28 completed the study. While no effect was observed on nasal congestion (primary outcome), treatment with NCC2461 significantly decreased nasal pruritus (determined by VAS), and leukocytes in nasal fluid samples, enhanced IL-5, IL-13 and IL-10 production by peripheral blood mononuclear cells in an allergen specific manner and tended to decrease IL-5 secretion in nasal fluid, in contrast to treatment with the blend of L. acidophilus and B. lactis. CONCLUSIONS: Despite short-term consumption, NCC2461 was able to reduce subjective nasal pruritus while not affecting nasal congestion in adults suffering from grass pollen allergic rhinitis. The associated decrease in nasal fluid leukocytes and IL-5 secretion, and the enhanced IL-10 secretion in an allergen specific manner may partly explain the decrease in nasal pruritus. However, somewhat unexpected systemic immune changes were also noted. These data support the study of NCC2461 consumption in a seasonal clinical trial to further demonstrate its potentially beneficial effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent findings suggest an association between exposure to cleaning products and respiratory dysfunctions including asthma. However, little information is available about quantitative airborne exposures of professional cleaners to volatile organic compounds deriving from cleaning products. During the first phases of the study, a systematic review of cleaning products was performed. Safety data sheets were reviewed to assess the most frequently added volatile organic compounds. It was found that professional cleaning products are complex mixtures of different components (compounds in cleaning products: 3.5 ± 2.8), and more than 130 chemical substances listed in the safety data sheets were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%), skin (50%) and by ingestion (60%) were the most reported. Monoethanolamine, a strong irritant and known to be involved in sensitizing mechanisms as well as allergic reactions, is frequently added to cleaning products. Monoethanolamine determination in air has traditionally been difficult and air sampling and analysis methods available were little adapted for personal occupational air concentration assessments. A convenient method was developed with air sampling on impregnated glass fiber filters followed by one step desorption, gas chromatography and nitrogen phosphorous selective detection. An exposure assessment was conducted in the cleaning sector, to determine airborne concentrations of monoethanolamine, glycol ethers, and benzyl alcohol during different cleaning tasks performed by professional cleaning workers in different companies, and to determine background air concentrations of formaldehyde, a known indoor air contaminant. The occupational exposure study was carried out in 12 cleaning companies, and personal air samples were collected for monoethanolamine (n=68), glycol ethers (n=79), benzyl alcohol (n=15) and formaldehyde (n=45). All but ethylene glycol mono-n-butyl ether air concentrations measured were far below (<1/10) of the Swiss eight hours occupational exposure limits, except for butoxypropanol and benzyl alcohol, where no occupational exposure limits were available. Although only detected once, ethylene glycol mono-n-butyl ether air concentrations (n=4) were high (49.5 mg/m3 to 58.7 mg/m3), hovering at the Swiss occupational exposure limit (49 mg/m3). Background air concentrations showed no presence of monoethanolamine, while the glycol ethers were often present, and formaldehyde was universally detected. Exposures were influenced by the amount of monoethanolamine in the cleaning product, cross ventilation and spraying. The collected data was used to test an already existing exposure modeling tool during the last phases of the study. The exposure estimation of the so called Bayesian tool converged with the measured range of exposure the more air concentrations of measured exposure were added. This was best described by an inverse 2nd order equation. The results suggest that the Bayesian tool is not adapted to predict low exposures. The Bayesian tool should be tested also with other datasets describing higher exposures. Low exposures to different chemical sensitizers and irritants should be further investigated to better understand the development of respiratory disorders in cleaning workers. Prevention measures should especially focus on incorrect use of cleaning products, to avoid high air concentrations at the exposure limits. - De récentes études montrent l'existence d'un lien entre l'exposition aux produits de nettoyages et les maladies respiratoires telles que l'asthme. En revanche, encore peu d'informations sont disponibles concernant la quantité d'exposition des professionnels du secteur du nettoyage aux composants organiques volatiles provenant des produits qu'ils utilisent. Pendant la première phase de cette étude, un recueil systématique des produits professionnels utilisés dans le secteur du nettoyage a été effectué. Les fiches de données de sécurité de ces produits ont ensuite été analysées, afin de répertorier les composés organiques volatiles les plus souvent utilisés. Il a été mis en évidence que les produits de nettoyage professionnels sont des mélanges complexes de composants chimiques (composants chimiques dans les produits de nettoyage : 3.5 ± 2.8). Ainsi, plus de 130 substances listées dans les fiches de données de sécurité ont été retrouvées dans les 105 produits répertoriés. Les principales classes de substances chimiques identifiées étaient les parfums, les éthers de glycol, les agents de surface et les solvants; dans une moindre mesure, les phosphates, les sels, les détergents, les régulateurs de pH, les acides et les bases ont été identifiés. Plus de 75% des produits répertoriés contenaient des substances décrites comme irritantes (Xi), 64% nuisibles (Xn) et 28% corrosives (C). Les risques pour les yeux (59%), la peau (50%) et par ingestion (60%) était les plus mentionnés. La monoéthanolamine, un fort irritant connu pour être impliqué dans les mécanismes de sensibilisation tels que les réactions allergiques, est fréquemment ajouté aux produits de nettoyage. L'analyse de la monoéthanolamine dans l'air a été habituellement difficile et les échantillons d'air ainsi que les méthodes d'analyse déjà disponibles étaient peu adaptées à l'évaluation de la concentration individuelle d'air aux postes de travail. Une nouvelle méthode plus efficace a donc été développée en captant les échantillons d'air sur des filtres de fibre de verre imprégnés, suivi par une étape de désorption, puis une Chromatographie des gaz et enfin une détection sélective des composants d'azote. Une évaluation de l'exposition des professionnels a été réalisée dans le secteur du nettoyage afin de déterminer la concentration atmosphérique en monoéthanolamine, en éthers de glycol et en alcool benzylique au cours des différentes tâches de nettoyage effectuées par les professionnels du nettoyage dans différentes entreprises, ainsi que pour déterminer les concentrations atmosphériques de fond en formaldéhyde, un polluant de l'air intérieur bien connu. L'étude de l'exposition professionnelle a été effectuée dans 12 compagnies de nettoyage et les échantillons d'air individuels ont été collectés pour l'éthanolamine (n=68), les éthers de glycol (n=79), l'alcool benzylique (n=15) et le formaldéhyde (n=45). Toutes les substances mesurées dans l'air, excepté le 2-butoxyéthanol, étaient en-dessous (<1/10) de la valeur moyenne d'exposition aux postes de travail en Suisse (8 heures), excepté pour le butoxypropanol et l'alcool benzylique, pour lesquels aucune valeur limite d'exposition n'était disponible. Bien que détecté qu'une seule fois, les concentrations d'air de 2-butoxyéthanol (n=4) étaient élevées (49,5 mg/m3 à 58,7 mg/m3), se situant au-dessus de la frontière des valeurs limites d'exposition aux postes de travail en Suisse (49 mg/m3). Les concentrations d'air de fond n'ont montré aucune présence de monoéthanolamine, alors que les éthers de glycol étaient souvent présents et les formaldéhydes quasiment toujours détectés. L'exposition des professionnels a été influencée par la quantité de monoéthanolamine présente dans les produits de nettoyage utilisés, par la ventilation extérieure et par l'emploie de sprays. Durant la dernière phase de l'étude, les informations collectées ont été utilisées pour tester un outil de modélisation de l'exposition déjà existant, l'outil de Bayesian. L'estimation de l'exposition de cet outil convergeait avec l'exposition mesurée. Cela a été le mieux décrit par une équation du second degré inversée. Les résultats suggèrent que l'outil de Bayesian n'est pas adapté pour mettre en évidence les taux d'expositions faibles. Cet outil devrait également être testé avec d'autres ensembles de données décrivant des taux d'expositions plus élevés. L'exposition répétée à des substances chimiques ayant des propriétés irritatives et sensibilisantes devrait être investiguée d'avantage, afin de mieux comprendre l'apparition de maladies respiratoires chez les professionnels du nettoyage. Des mesures de prévention devraient tout particulièrement être orientées sur l'utilisation correcte des produits de nettoyage, afin d'éviter les concentrations d'air élevées se situant à la valeur limite d'exposition acceptée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endotoxin causes an inflammation at the bronchial and alveolar level. The inflammation-induced increase in permeability of the bronchoalveolar epithelial barrier is supposed to cause a leakage of pneumoproteins. Therefore, their concentrations are expected to increase in the bloodstream.This study aimed at examining the association between occupational exposure to endotoxin and a serum pneumoprotein, surfactant protein A, to look for nonoccupational factors capable of confounding this association, and examine the relation between surfactant protein A and spirometry. There were 369 control subjects, 325 wastewater workers, and 84 garbage collectors in the study. Exposure to endotoxin was assessed through personal sampling and the Limulus amebocytes lysate assay. Surfactant protein A was determined by an in house sandwich enzyme-linked immunosorbent assay (ELISA) in 697 subjects. Clinical and smoking history were ascertained and spirometry carried out according to American Thoracic Society criteria. Multiple linear regression was used for statistical analysis. Exposure was fairly high during some tasks in wastewater workers but did not influence surfactant protein A. Surfactant protein A was lower in asthmatics. Interindividual variability was large. No correlation with spirometry was found. Endotoxin has no effect on surfactant protein A at these endotoxin levels and serum surfactant protein A does not correlate with spirometry. The decreased surfactant protein A secretion in asthmatics requires further study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The international recommendations issued by GINA (Global Initiative for Asthma) have undergone considerable adaptations over the last years. This article proposes the local adaptation of those guidelines bearing on the practical aspects of the treatment for the general practitioner's use. One of the fundamental changes in these new guidelines on good practice relates to the permanent adaptation of the treatment on the basis of symptom control rather than on the severity of the asthma. Another change from the old recommendations concerns the manner in which the asthma is categorised into different phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Airborne microbial products have been reported to promote immune responses that suppress asthma, yet how these beneficial effects take place remains controversial and poorly understood. We have found that pulmonary exposure with the bacterium Escherichia coli leads to a suppression of allergic airway inflammation, characterized by reduced airway-hyperresponsiveness, eosinophilia and cytokine production by T cells in the lung. This immune modulation was neither mediated by the induction of a Th1 response nor regulatory T cells; was dependent on TLR-4 but did not involve TLR-desensitization. Dendritic cell migration to the draining lymph nodes and subsequent activation of T cells was unaffected by prior exposure to E.coli indicating that the immunomodulation was limited to the lung environment. In non-treated control mice ovalbumin was primarily presented by airway CD11b+ CD11c+ DCs expressing high levels of MHC class II molecules whilst the DCs in E.coli-treated mice displayed a less activated phenotype and had impaired antigen presentation capacity. Consequently, in situ Th2 cytokine production by ovalbuminspecific effector T cells recruited to the airways was significantly reduced. The suppression of airways hyper responsiveness was mediated through the recruitment of IL-17-producing gd-T cells; however, the suppression of dendritic cells and T cells was mediated through a distinct mechanism that could not be overcome by the local administration of activated dendritic cells, or by the in vivo administration of TNF-alpha. Taken together, these data reveal a novel multi-component immunoregulatory pathway that acts to protect the airways from allergic inflammation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metabolites from intestinal microbiota are key determinants of host-microbe mutualism and, consequently, the health or disease of the intestinal tract. However, whether such host-microbe crosstalk influences inflammation in peripheral tissues, such as the lung, is poorly understood. We found that dietary fermentable fiber content changed the composition of the gut and lung microbiota, in particular by altering the ratio of Firmicutes to Bacteroidetes. The gut microbiota metabolized the fiber, consequently increasing the concentration of circulating short-chain fatty acids (SCFAs). Mice fed a high-fiber diet had increased circulating levels of SCFAs and were protected against allergic inflammation in the lung, whereas a low-fiber diet decreased levels of SCFAs and increased allergic airway disease. Treatment of mice with the SCFA propionate led to alterations in bone marrow hematopoiesis that were characterized by enhanced generation of macrophage and dendritic cell (DC) precursors and subsequent seeding of the lungs by DCs with high phagocytic capacity but an impaired ability to promote T helper type 2 (TH2) cell effector function. The effects of propionate on allergic inflammation were dependent on G protein-coupled receptor 41 (GPR41, also called free fatty acid receptor 3 or FFAR3), but not GPR43 (also called free fatty acid receptor 2 or FFAR2). Our results show that dietary fermentable fiber and SCFAs can shape the immunological environment in the lung and influence the severity of allergic inflammation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Because of its high prevalence, early screening for occupational asthma (OA) is crucial. We aimed to evaluate the screening performance of the Occupational Asthma Screening Questionnaire-11 items (OASQ-11) in a clinical setting. METHODS: Between January 2009 and December 2011, 169 workers referred for potential OA to our hospital completed the OASQ-11 and underwent workups to determine the final diagnosis. The discriminative abilities of the OASQ-11 as a whole and in relation to demographic and exposure parameters were determined by the area under the receiving operator characteristic curve (AUC). RESULTS: Model 1, consisting of the OASQ's items, showed fair discrimination (AUC, 0.69; 95% confidence interval, 0.58 to 0.80). Addition of age and exposure duration to model 1 improved discrimination (AUC, 0.80; confidence interval, 0.72 to 0.88). CONCLUSION: A simple model consisting of the OASQ-11's items, age, and exposure duration could well discriminate subjects with OA in a clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pour connaître le devenir à long terme des patients intubés pour état de mal asthmatique, nous avons recontacté en 1990 les 34 patients qui avaient présenté, entre 1978 et 1988, quarante épisodes de détresse respiratoire aiguë. Deux patients sont vivants mais ont été perdus de vue, 3 sont morts dont un seul d'état de mal asthmatique 6 mois après l'épisode initial. Des 29 patients restants (7 hommes et 22 femmes, âge moyen de 48,5 ans) représentant un suivi moyen de 9,6 ans, quinze n'ont jamais été réhospitalisés; des 14 autres, seuls 5 ont requis une intubation et une ventilation mécanique lors d'un épiode ultérieur. La majorité des hospitalisations ultérieures (81%) sont survenues dans les 6 ans suivant l'épiode initial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, a locus centred on rs9273349 in the HLA-DQ region emerged from genome-wide association studies of adult-onset asthma. We aimed to further investigate the role of human leukocyte antigen (HLA) class II in adult-onset asthma and a possible interaction with occupational exposures. We imputed classical HLA-II alleles from 7579 single-nucleotide polymorphisms in 6025 subjects (1202 with adult-onset asthma) from European cohorts: ECRHS, SAPALDIA, EGEA and B58C, and from surveys of bakers and agricultural workers. Based on an asthma-specific job-exposure matrix, 2629 subjects had ever been exposed to high molecular weight (HMW) allergens. We explored associations between 23 common HLA-II alleles and adult-onset asthma, and tested for gene-environment interaction with occupational exposure to HMW allergens. Interaction was also tested for rs9273349. Marginal associations of classical HLA-II alleles and adult-onset asthma were not statistically significant. Interaction was detected between the DPB1*03:01 allele and exposure to HMW allergens (p = 0.009), in particular to latex (p = 0.01). In the unexposed group, the DPB1*03:01 allele was associated with adult-onset asthma (OR 0.67, 95%CI 0.53-0.86). HMW allergen exposures did not modify the association of rs9273349 with adult-onset asthma. Common classical HLA-II alleles were not marginally associated with adult-onset asthma. The association of latex exposure and adult-onset asthma may be modified by DPB1*03:01.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of allergic bronchopulmonary aspergillosis (ABPA) in cystic fibrosis patients remains challenging, mainly owing to overlapping symptoms of the underlying lung disease with clinical symptoms of ABPA. In addition, a varying mixture of diagnostic criteria, including clinical status, radiological findings and immunological measurements, has led to confusion and differing recommendations. In order to help simplify as well as standardize the diagnostic criteria for ABPA, different serological markers have been evaluated in the last 20 years and their usefulness has been assessed in many clinical studies. This review presents current diagnostic criteria of ABPA, with a special focus on serum markers supporting the diagnosis and explains why the hunt for a serological marker for ABPA is still ongoing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhaled therapies are preferred to systemic ones during pregnancy and breast feeding. A real paradox exists however between the necessity to ensure an optimal treatment for pregnant women with asthma, in order to prevent fetal hypoxia, and the precaution linked to any drug prescription during pregnancy. Thus, the use of topical corticosteroids remains the first choice for asthma as well as rhinitis. Inhaled beta2-agonists are also recommended. Systemic corticosteroids may however be prescribed without hesitation when their use is required for asthma treatment. It is also interesting to note that oral second-generation antihistamines are currently allowed during pregnancy and breast feeding. This type of antihistamines is indeed to be preferred to first-generation ones that generate more side-effects and generally are thus not to be prescribed during breast feeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Occupational diisocyanate-induced extrinsic allergic alveolitis (EAA) is a rare and probably underestimated diagnosis. Two acute occupational EAA cases have been described in this context, but neither of them concerned hexamethylene diisocyanate (HDI) exposure. AIMS: To investigate the cause of a life-threatening EAA arising at work in a healthy 30-year-old female paint quality controller. METHODS: Occupational medical assessment, workplace evaluation, airborne and biological monitoring and immunodermatological tests. RESULTS: Diagnosis of EAA relied on congruent clinical and radiological information, confirmed occupational HDI exposure and positive IgG antibodies and patch tests. The patient worked in a small laboratory for 7 years, only occasionally using HDI-containing hardeners. While working with HDI for 6 h, she developed breathlessness, rapidly progressing to severe respiratory failure. Workplace HDI airborne exposure values ranged from undetectable levels to 4.25 p.p.b. Biological monitoring of urinary hexamethylene diamine in co-workers ranged from <1.0 to 15.4 μg/g creatinine. Patch tests 8 months later showed delayed skin reaction to HDI at 48 h. Subsequent skin biopsy showed spongiotic dermatitis with infiltration of CD4(+) and CD8(+) T cells. CONCLUSIONS: We believe this is the first reported case of acute life-threatening EAA following exposure to HDI. Low concentrations of airborne HDI and relatively high urinary hexamethylene diamine suggest significant skin absorption of HDI could have significantly contributed to the development of this acute occupational EAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'asthme est une des maladies chroniques des plus fréquentes chez l'enfant qui touche 7,6 à 10,7 % de la population infantile française (ISAAC, 1998). Un des facteurs étiologiques impliqué dans cette pathologie est les moisissures présentes dans l'habitat. Néanmoins, il reste toujours à clarifier quelle est la fenêtre d'exposition la plus critique au cours de l'enfance et à comprendre le mécanisme de cette étiologie. En effet, des effets contradictoires ont été associés à l'exposition précoce des enfants aux moisissures. L'exposition à une espèce de moisissure dominante augmente l'incidence de l'asthme chez le jeune enfant, alors que l'exposition à des bioaérosols riches et diversifiés en micro-organismes, comme ceux présent dans les fermes, le diminue. Ces deux effets font l'objet des deux études choisies dans cette note. [Auteure]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Innate immune sensors control key cytokines that regulate T-cell priming and T-cell fate. This is particularly evident in allergic reactions, which represent ideal systems to study the interplay of innate and adaptive immunity. In patients with contact dermatitis, inflammasome-mediated IL-1 activation is responsible for a TH1 immune response. Surprisingly, the IL-1 signaling pathway was also proposed to control the activation of thymic stromal lymphopoietin (TSLP), a cytokine implicated in development of the TH2 response in patients with atopic dermatitis (AD) and asthma. OBJECTIVES: We sought to assess the effect of the inflammasome on TSLP expression levels and the development of AD. METHODS: We studied the effect of the inflammasome activator 2,4-dinitrofluorobenzene, and IL-1β on TSLP mRNA expression levels in mouse and human cell lines (in vitro assays), as well as in live mice and on human skin transplants. We also assessed the effect of 2,4-dinitrofluorobenzene on TSLP and the TH2 response in mice in which the inflammasome and IL-1 signaling pathways were blocked, either genetically or pharmacologically, in 2 models of AD. RESULTS: We provide in vitro and in vivo evidence that inflammasome activation has an inhibitory role on TSLP mRNA expression and TH2 cell fate in the skin. We also show that solvents influence the activation of TSLP and IL-1β and direct the T-cell fate to a given hapten. CONCLUSION: Our observations strongly suggest that the TH1 versus TH2 cell fate decision is regulated at multiple levels and starts with innate immune events occurring within peripheral epithelial tissues.