969 resultados para Air turbine power take-off


Relevância:

40.00% 40.00%

Publicador:

Resumo:

"February 1996."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The basis of this work was to investigate the relative environmental impacts of various power generators knowing that all plants are located in totally different environments and that different receptors will experience different impacts. Based on IChemE sustainability metrics paradigm, we calculated potential environmental indicators (P-EI) that represent the environmental burden of masses of potential pollutants discharged into different receiving media. However, a P-EI may not be of significance, as it may not be expressed at all in different conditions, so to try and include some receiver significance we developed a methodology to take into account some specific environmental indicators (S-EI) that refer to the environmental attributes of a specific site. In this context, we acquired site specific environmental data related to the airsheds and water catchment areas in different locations for a limited number of environmental indicators such as human health (carcinogenic) effects, atmospheric acidification, photochemical (ozone) smog and eutrophication. The S-EI results from this particular analysis show that atmospheric acidification has highest impact value while health risks due to fly ash emissions are considered not to be as significant. This is due to the fact that many coal power plants in Australia are located in low population density air sheds. The contribution of coal power plants to photochemical (ozone) smog and eutrophication were not significant. In this study, we have considered emission related data trends to reflect technology performance (e.g., P-EI indicators) while a real sustainability metric can be associated only with the specific environmental conditions of the relevant sites (e.g., S-EI indicators).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this article, the authors analyze participants' accounts of why they took part in a repeat-interview study exploring newly diagnosed patients' perceptions of diabetes service provision in Lothian, Scotland. The study involved three semistructured in-depth interviews with each patient (N = 40), which spanned a year. The authors provide a thematic discursive analysis of responses to the question, Can I ask you what made you decide to part in the study and why you've stayed involved over the past year? The main themes are (a) recruitment within health contexts ("the nurse said it would help"), (b) altruism ("if it can help somebody"), (c) qualitative research being seen as inherently innocuous ("nothing to lose"), and (d) therapeutic aspects of interviewing ("getting it off my chest"). The analysis contributes both to the qualitative literature about generic research participation and to a germinal literature exploring qualitative health research participation. © 2006 Sage Publications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Various micro-radial compressor configurations were investigated using one-dimensional meanline and computational fluid dynamics (CFD) techniques for use in a micro gas turbine (MGT) domestic combined heat and power (DCHP) application. Blade backsweep, shaft speed, and blade height were varied at a constant pressure ratio. Shaft speeds were limited to 220 000 r/min, to enable the use of a turbocharger bearing platform. Off-design compressor performance was established and used to determine the MGT performance envelope; this in turn was used to assess potential cost and environmental savings in a heat-led DCHP operating scenario within the target market of a detached family home. A low target-stage pressure ratio provided an opportunity to reduce diffusion within the impeller. Critically for DCHP, this produced very regular flow, which improved impeller performance for a wider operating envelope. The best performing impeller was a low-speed, 170 000 r/min, low-backsweep, 15° configuration producing 71.76 per cent stage efficiency at a pressure ratio of 2.20. This produced an MGT design point system efficiency of 14.85 per cent at 993 W, matching prime movers in the latest commercial DCHP units. Cost and CO2 savings were 10.7 per cent and 6.3 per cent, respectively, for annual power demands of 17.4 MWht and 6.1 MWhe compared to a standard condensing boiler (with grid) installation. The maximum cost saving (on design point) was 14.2 per cent for annual power demands of 22.62 MWht and 6.1 MWhe corresponding to an 8.1 per cent CO2 saving. When sizing, maximum savings were found with larger heat demands. When sized, maximum savings could be made by encouraging more electricity export either by reducing household electricity consumption or by increasing machine efficiency.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A study on heat pump thermodynamic characteristics has been made in the laboratory on a specially designed and instrumented air to water heat pump system. The design, using refrigerant R12, was based on the requirement to produce domestic hot water at a temperature of about 50 °C and was assembled in the laboratory. All the experimental data were fed to a microcomputer and stored on disk automatically from appropriate transducers via amplifier and 16 channel analogue to digital converters. The measurements taken were R12 pressures and temperatures, water and R12 mass flow rates, air speed, fan and compressor input powers, water and air inlet and outlet temperatures, wet and dry bulb temperatures. The time interval between the observations could be varied. The results showed, as expected, that the COP was higher at higher air inlet temperatures and at lower hot water output temperatures. The optimum air speed was found to be at a speed when the fan input power was about 4% of the condenser heat output. It was also found that the hot water can be produced at a temperature higher than the appropriate R12 condensing temperature corresponding to condensing pressure. This was achieved by condenser design to take advantage of discharge superheat and by further heating the water using heat recovery from the compressor. Of the input power to the compressor, typically about 85% was transferred to the refrigerant, 50 % by the compression work and 35% due to the heating of the refrigerant by the cylinder wall, and the remaining 15% (of the input power) was rejected to the cooling medium. The evaporator effectiveness was found to be about 75% and sensitive to the air speed. Using the data collected, a steady state computer model was developed. For given input conditions s air inlet temperature, air speed, the degree of suction superheat , water inlet and outlet temperatures; the model is capable of predicting the refrigerant cycle, compressor efficiency, evaporator effectiveness, condenser water flow rate and system Cop.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The paper describes the use of the system created for Digital off-air radio events archive EventsBNR in the Bulgarian National Radio. The system provides efficient application of modern information technologies in radio archiving.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ACM Computing Classification System (1998): H.2.1, H.2.4, H.2.8, H.3.7, J.5.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For micro gas turbines (MGT) of around 1 kW or less, a commercially suitable recuperator must be used to produce a thermal efficiency suitable for use in UK Domestic Combined Heat and Power (DCHP). This paper uses computational fluid dynamics (CFD) to investigate a recuperator design based on a helically coiled pipe-in-pipe heat exchanger which utilises industry standard stock materials and manufacturing techniques. A suitable mesh strategy was established by geometrically modelling separate boundary layer volumes to satisfy y + near wall conditions. A higher mesh density was then used to resolve the core flow. A coiled pipe-in-pipe recuperator solution for a 1 kW MGT DCHP unit was established within the volume envelope suitable for a domestic wall-hung boiler. Using a low MGT pressure ratio (necessitated by using a turbocharger oil cooled journal bearing platform) meant unit size was larger than anticipated. Raising MGT pressure ratio from 2.15 to 2.5 could significantly reduce recuperator volume. Dimensional reasoning confirmed the existence of optimum pipe diameter combinations for minimum pressure drop. Maximum heat exchanger effectiveness was achieved using an optimum or minimum pressure drop pipe combination with large pipe length as opposed to a large pressure drop pipe combination with shorter pipe length. © 2011 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

World War II profoundly impacted Florida. The military geography of the State is essential to an understanding the war. The geostrategic concerns of place and space determined that Florida would become a statewide military base. Florida's attributes of place such as climate and topography determined its use as a military academy hosting over two million soldiers, nearly 15 percent of the GI Army, the largest force the US ever raised. One-in-eight Floridians went into uniform. Equally, Florida's space on the planet made it central for both defensive and offensive strategies. The Second World War was a war of movement, and Florida was a major jump off point for US force projection world-wide, especially of air power. Florida's demography facilitated its use as a base camp for the assembly and engagement of this military power. In 1940, less than two percent of the US population lived in Florida, a quiet, barely populated backwater of the United States. But owing to its critical place and space, over the next few years it became a 65,000 square mile training ground, supply dump, and embarkation site vital to the US war effort. Because of its place astride some of the most important sea lanes in the Atlantic World, Florida was the scene of one of the few Western Hemisphere battles of the war. The militarization of Florida began long before Pearl Harbor. The pre-war buildup conformed to the US strategy of the war. The strategy of theUS was then (and remains today) one of forward defense: harden the frontier, then take the battle to the enemy, rather than fight them in North America. The policy of "Europe First," focused the main US war effort on the defeat of Hitler's Germany, evaluated to be the most dangerous enemy. In Florida were established the military forces requiring the longest time to develop, and most needed to defeat the Axis. Those were a naval aviation force for sea-borne hostilities, a heavy bombing force for reducing enemy industrial states, and an aerial logistics train for overseas supply of expeditionary campaigns. The unique Florida coastline made possible the seaborne invasion training demanded for US victory. The civilian population was employed assembling mass-produced first-generation container ships, while Floridahosted casualties, Prisoners-of-War, and transient personnel moving between the Atlantic and Pacific. By the end of hostilities and the lifting of Unlimited Emergency, officially on December 31, 1946, Floridahad become a transportation nexus. Florida accommodated a return of demobilized soldiers, a migration of displaced persons, and evolved into a modern veterans' colonia. It was instrumental in fashioning the modern US military, while remaining a center of the active National Defense establishment. Those are the themes of this work.